• 제목/요약/키워드: hourly variation

검색결과 138건 처리시간 0.026초

오존농도의 動態 및 影響因子에 關한 硏究 (Studies on the Behaviour of Ozone Concentration and the Influencing Factors)

  • 金旻永;姜熙坤;李完宗;李相七;張鳳勳;朴聖培
    • 한국대기환경학회지
    • /
    • 제5권2호
    • /
    • pp.55-71
    • /
    • 1989
  • This study was carried out to determine the ozone concentration to behaviour and the factors to be influenced the variation of its concentration in the ambient air in Seoul. Measurements of ozone concentrations were made at 10 monitoring station to take care of SIHE (Seoul Institute of Health & Environment) during December 1987 to November 1988, also measured the hourly average concentration of sulfur dioxide, total suspended particulate, nitrogen oxide $(NO & NO_2)$, carbon monoxide, hydro carbon $(n-CH_4 & THC)$ and meteorological factors, that is, temperature, humidity, wind velocity wind direction and ultraviolet intensity etc, for the same period at same place. The basis of the data obtained were analyzed statistically along with the various data. The results were as follows; 1. The annually arithmetic mean concentration of ozone for the 10 sites during one years was 10.0 ppb and ranged from 3.1 $\pm$ 4.5ppb at the Kuro industrial complex to 17.2 $\pm$ 18.7 ppb at the Ssangmun site. 2. The frequency of hours on which oxidant concentrations exceeded the present short term standard of ozone (100 ppb) were 78 times. 3. The diurnal patterns of hourly ozone concentrations in Seoul area was a typical bi-modal variation which have 4 to 5 a.m. peak and 3. to 4 p.m peak. 4. The time ozone of highest ozone concentration in a whole day and hight was 1 to 5 p.m and 90.9 percent of appearence rate. 5. The diurnal patterns of hourly ozone concentrations in Seoul were on the whole the order of daytime from 5.8ppb to 28.7 ppb evening from 1.7 to 18.7 ppb night time from 1.9 to 9.3 ppb daybreak from 1.4ppb according to measuring sites, and the highest that observed at the Ssangmun area while the lowest was the Kuro industrial complex monitor sites. 6. The weekly variation of ozone concentration was the higher level ozone concentration in the day of the week occured sunday-monday and weekend but the decrease were observed from wednesday to thursday.

  • PDF

기상레이더 자료를 이용한 시우량곡면 예측 (Hourly Rainfall Surface Prediction with Meteorological Radar Data)

  • 정재성;이재형
    • 물과 미래
    • /
    • 제29권3호
    • /
    • pp.187-195
    • /
    • 1996
  • 남한강 상류 평창강 유역을 대상으로 기상레이더 자료와 지상강우량 자료를 이용한 시우량 곡면 예측 방법을 연구하였다. 레이더 자료의 이용시에 필요한 비정상 에코와 지형에코의 제거, 강우에 의한 감쇄 효과의 보정 방법, 레이더 반사도 Z와 강우강도 R의 관계, 등을 검토분석하였다. 보정된 레이더 반사도 자료를 레이더 우량곡면으로 변환하고, 그 결과와 지상강우량 자료를 이용하여 시우량곡면을 합성하였다. 시우량곡면 예측을 위하여 상호상관 계수법을 이용한 강우장의 이동성과 유역 평균 레이더 강우강도의 시변성을 고려하였다. 이 예측방법을 합성된 시우량곡면 자료에 적용하여 3시간까지의 시우량곡면을 예측하고, 예측된 결과를 지상우량 및 합성우량 곡면과 비교하였다. 본 연구의 단시간 강우예측 방법은 보다 많은 자료를 이용한 검증과 강우장의 물리적 특성 및 지형을 고려한 방법으로의 보완이 필요한 것으로 사료되었다.

  • PDF

기온감률의 일중 경시변화 예측 가능성 (Feasibility of the Lapse Rate Prediction at an Hourly Time Interval)

  • 김수옥;윤진일
    • 한국농림기상학회지
    • /
    • 제18권1호
    • /
    • pp.55-63
    • /
    • 2016
  • 경계층 내에서는 일중 시간대에 따라 기온감률의 변이가 크므로, 복잡지형의 기온분포 추정에 흔히 사용되는 표준기온감률보다 현실성 있는 매시 기온감률 추정 방법을 고안하였다. 이 방법에서는 기온 경시변동의 장기간 평균을 기준으로 하되, 표준등압면 1000-925hPa 층위의 기온감률을 이용하여 기온감률 표준곡선을 작성하고, 여기에 매시 운량에 따라 보정된 기온감률이 모의된다. 신뢰성 검증을 위해 대관령 지역에 적용하여 10개월 간 매시 기온감률을 추정하고 그 결과를 초음파 기온프로파일러로부터 얻은 지상 500-600m 층위 실측 기온감률과 비교한 결과, ME $-0.0001^{\circ}C/m$, RMSE $0.0024^{\circ}C/m$였다. 이 방법을 지상 1.5m에서 측정되는 산사면의 고도별 기온감률 추정에 적용할 수 있는지 확인하기 위해 복잡지형인 '하동2수위표' 표준유역의 313-401m 고도구간 매시 기온감률을 계산하였다. 해당 유역 산사면 여러 지점으로부터 실측기온을 얻어 기온감률을 구한 다음 추정값과 비교한 결과 대관령의 연직 프로파일에 비해 오차가 컸지만 하늘상태에 따른 일중 기온감률의 변동경향은 이 방법에 의해 모의할 수 있었다.

학교 건물용 지열 히트펌프 시스템 설계와 지중 순환수 온도 변화 분석 (Design of Ground-Coupled Heat Pump (GCHP) System and Analysis of Ground Source Temperature Variation for School Building)

  • 손병후
    • 한국지열·수열에너지학회논문집
    • /
    • 제16권1호
    • /
    • pp.17-25
    • /
    • 2020
  • Ground-coupled heat pump (GCHP) systems have become an efficient alternative to conventional cooling and heating methods due to their higher energy using efficiency. Although some experimental and simulation works related to performance analysis of GCHP systems for commercial buildings have been done, relatively little has been reported on the performance evaluation of GCHP systems for school buildings. The purpose of this simulation study is to evaluate the performance of a hypothetical GCHP system for a school building in Seoul. We collected various data of building specifications and construction materials for the building and then modeled to calculate hourly building loads with SketchuUp and TRNSYS V17. In addition, we used GLD (Ground Loop Design) V2016, a GCHP system design and simulation software, to design the GCHP system for the building and to simulate temperature of circulating water in ground heat exchanger. The variation of entering source temperature (EST) into the system was calculated with different prediction time and then each result was compared. For 20 years of prediction time, EST for baseline design (Case A) based on the hourly simulation results were outranged from the design criteria.

Long-Term Wind Resource Mapping of Korean West-South Offshore for the 2.5 GW Offshore Wind Power Project

  • Kim, Hyun-Goo;Jang, Moon-Seok;Ko, Suk-Hwan
    • 한국환경과학회지
    • /
    • 제22권10호
    • /
    • pp.1305-1316
    • /
    • 2013
  • A long-term wind resource map was made to provide the key design data for the 2.5 GW Korean West-South Offshore Wind Project, and its reliability was validated. A one-way dynamic downscaling of the MERRA reanalysis meteorological data of the Yeongwang-Gochang offshore was carried out using WindSim, a Computational Fluid Dynamics based wind resource mapping software, to establish a 33-year time series wind resource map of 100 m x 100 m spatial resolution and 1-hour interval temporal resolution from 1979 to 2012. The simulated wind resource map was validated by comparison with wind measurement data from the HeMOSU offshore meteorological tower, the Wangdeungdo Island meteorological tower, and the Gochang transmission tower on the nearby coastline, and the uncertainty due to long-term variability was analyzed. The long-term variability of the wind power was investigated in inter-annual, monthly, and daily units while the short-term variability was examined as the pattern of the coefficient of variation in hourly units. The results showed that the inter-annual variability had a maximum wind index variance of 22.3% while the short-term variability, i.e., the annual standard deviation of the hourly average wind power, was $0.041{\pm}0.001$, indicating steady variability.

낙동강 수질변동에 대한 추계학적 연구 (A study on Stochastic Properties of Water Quality Variation in the Nack-Dong River.)

  • 김미숙
    • 한국환경보건학회지
    • /
    • 제9권1호
    • /
    • pp.15-30
    • /
    • 1983
  • The stochastic analysis was carried out to the hourly time series observed at Dae-gu, Wha-Myung and Ku-Mee in order to see water quality variation of the Nack-Dong River during Three months (July, Aug. and Sept.) in each year of 1979 and 1981. As a result of this study, it was found that 1. The simple correlation coefficients between some of the variables were fairly high. For example, the coefficients between Do and WT. were -0.824 (Dae-gu), -0.547 (Wha-myung), and -0.911(Ku-mee). The coefficients between COND and DO. were -0.263(Dae-gu), -0.347(Wha-myung) and -0.881 (Ku-mee). The coefficients between COND and WT. were 0.531 (Dae-gu), 0.361 (Wha-myung) and 0.800 (Ku-mee). 2. Hourly water quality time series of WT and DO existed as dominant 24 hours Periodicity For example, the Aut correlation coefficients about WT were 0.960 (K=1), 0.846(K=24), 0.691(K=48), 0.596(K=72), and 0.453(K=96). The auto-correlation coefficients of Do were 0.968 (K=1), 0.591 (K=24), 0.393 (K=48), 0.349 (K=72) and 0.250 (K=96). 3. Weekly water quality time series of WT and Do varied with the dominant 24 hours periodicity.

  • PDF

대형증발계 증발량의 일 변화 (Short-term Variation in Class A Pan Evaporation)

  • 이부용
    • 한국농림기상학회지
    • /
    • 제4권4호
    • /
    • pp.197-202
    • /
    • 2002
  • A new method is used to estimate the amount of water evaporation from Class A Pan with higher precision and accuracy. The principle of method is to detect the weight change of a buoyant sinker resulting from a change in water level of Class A Pan. A strain-gauge load cell is used to measure the weight change. Field observation of evaporation was done at Pohang Meteorological Station from June 24 to August 4, 2002. By using this new method, it is possible to measure hourly evaporation accurately even under a strong solar radiation and wind disturbance, enabling a direct comparison of evaporation with other meteorological elements. At night, under low humidity and high wind speed conditions, more evaporation was recorded than during daytime. Maximum evaporation rates observed during this period exceed 1.0 mm/hour under the sunny and windy conditions with low humidity. To understand relationships between meteorological elements and latent heat flux at ground level, we suggest intensive held experiments using high accuracy evaporation recording instruments with hourly time interval.

철도방재시스템과 강우에 인한 철도기상사고 (Railroad Disaster Prevention System and Railroad Weather-Related Accidents and incidents according to Precipitation)

  • 박종길;정우식;김희만;김은별;이재수
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2010년도 춘계학술대회 논문집
    • /
    • pp.2014-2020
    • /
    • 2010
  • This paper aims to find out characteristics of railroad weather-related accidents and incidents and to proposes the plan of railroad disaster prevention according to the precipitation. For this, we make the database about the railroad weather-related accidents and incidents and analysis the relationship between the hourly and cumulative precipitation and railroad accidents. The results are as follows; The weather events that have the most occurrence frequency of railroad weather-related accidents and incidents is a rainfall of the precipitation and then the cause of that was the falling rocks and the collapsed roadbed. The rainfall patterns of collapsed roadbed were classified into 4 groups. When the variation of hourly rainfall is 10/15 mm/hr over, we need to consider the caution/stop of train operation and a speed limit, respectively.

  • PDF

국내 호텔 건물의 에너지 부하 모델 (Building Load Models for Hotels in Korea)

  • 박화춘;정모
    • 한국태양에너지학회 논문집
    • /
    • 제29권4호
    • /
    • pp.48-57
    • /
    • 2009
  • Energy demands for hotels in Korea are surveyed and statistically analyzed to develop calculation models for a simulation. Daily energy loads of 16 hotels located in Seoul, Busan, Daegu, Inchon, and Daejon are analyzed based on energy log sheets. Detailed hourly loads are field measured for 3 hotels that are carefully selected among the surveyed. One of the salient features for energy consumption by hotels is their weekly periodicity. Relatively large values of deviations are observed for both heat and electricity loads through the country. The mains factors are: location, hotel grade (luxuriousness) and insulation. Detailed quantitative information such are annual average, daily variation, and hourly patterns are provided.

동북아 오염물질 장거리이동 분석을 위한 서울시 대기 중 라돈농도의 시계열적 특성에 관한 연구 (Time Series Observations of Atmospheric Radon Concentration in Seoul, Korea for an Analysis of Long-Range Transportation of Air Pollutants in the North-East Asia)

  • 김윤신;이철민;김기연;전형진;김종철
    • 한국환경보건학회지
    • /
    • 제33권4호
    • /
    • pp.283-292
    • /
    • 2007
  • Atmospheric concentrations of radon had been continuously observed in Seoul, Korea since December 1999, as a tracer for long-range transport of air pollutants from China continent to Korea. In order to study radon as a tracer of long-range transport, it is important to know information about the atmospheric distribution and variation of radon concentration and its time variation. Atmospheric radon concentration are measured with electrostatic radon monitor(ERM) at Hanyang University located in Eastern area of Seoul. Air sample is taken into a vessel of ERM, and alpha particles emitted by radon daughters $Po^{218}$ are detected with ZnS(Ag) scintillation counter. Hourly mean concentrations and hourly alpha counts are recorded automatically. The major results obtained from time series observation of atmospheric radon were as follows : (1) The mean of airborne radon concentration in Seoul was found to be $7.62{\pm}4.11\;Bq/m^3$ during December $1999{\sim}January$ 2002. (2) The hourly variation of radon concentrations showed the highest in 8:00AM ($8.66{\pm}4.22\;Bq/m^3$) and the lowest in 3:00AM ($6.62{\pm}3.70\;Bq/m^3$) and 5:00AM ($6.62{\pm}3.39\;Bq/m^3$). (3) the seasonal variation of radon concentrations showed higher during winter-to-fall and lower during summer-to-spring. (4) Correlation between airborne radon concentration and the meteorological factors were -0.21 for temperature, 0.09 for humidity, -0.20 for wind speed, and 0.04 for pressure. (5) The mean difference of airborne radon concentration between Asian dust ($5.36{\pm}1.28\;Bq/m^3$) and non-Asian dust ($4.95{\pm}1.49\;Bq/m^3$) phenomenon was significant (p=0.08). We could identify time series distribution of radon concentration related meteorological factors. In addition, radon can be considered a good natural tracer of vertical dispersion and long-range transport.