HEAT PIPE TYPE EXHAUST HEAT RECOVERY SYSTEM FOR HOT AIR HEATER

  • Kang, G.C.;Kim, Y.J.;Ryou, Y.S.;Rhee, K.J.
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 2000년도 THE THIRD INTERNATIONAL CONFERENCE ON AGRICULTURAL MACHINERY ENGINEERING. V.III
    • /
    • pp.654-661
    • /
    • 2000
  • Area of greenhouse increases rapidly up to 45,265ha by the year of 1998 in Korea. Hot air heater with light oil combustion is the most common heater for greenhouse heating in the winter season. However, exhaust gas heat discharged to atmosphere through chimney reaches up to 10~20% of total heat of the oil combusted in the furnace. In order to recapture the heat of this exhaust gas and to recycle for greenhouse heating, the heat pipe type exhaust heat recovery system was manufactured and tested in this experiment. The exhaust heat recovery system was made for space heating in the greenhouse. The system consisted of a heat exchanger made of heat pipes, ${\emptyset}15.88{\times}600mm$ located in the rectangular box of $600{\times}550{\times}330mm$, a blower and air ducts. The rectangular box was divided by two compartments where hot chamber exposed to exhaust gas in which heat pipes could pick up the heat of exhaust gas, and by evaporation of the heat transfer medium in the pipes it carries the heat to the cold compartment, then the blower moves the heat to greenhouse. The number of heat pipe was 60, calculated considering the heat exchange amount between flue gas and heat transfer capacity of heat pipe. The working fluid of heat pipe was acetone because acetone is known for its excellent heat transfer capacity. The system was attached to the exhaust gas path. According to the performance test it could recover 53,809 to 74,613kJ/hr depending on the inlet air temperature of 12 to $-12^{circ}C$ respectively when air flow rate $1,100\textrm{m}^3/hr$. The exhaust gas temperature left the heat exchanger dropped to $100^{circ}C$ from $270^{circ}C$ by the heat exchange between the air and the flue gas, the temperature difference was collected by the air and the warm air temperature was about $60^{circ}C$ at the air flow rate of $1,100\textrm{m}^3/hr$. This heat pipe type exhaust heat recovery system can reduce fuel cost by 10% annually according to the economic analysis.

  • PDF

온돌 난방분배기의 개도조정 (Adjustment of Valve Opening in Ondol Hot Water Distributor)

  • 홍희기;김시환
    • 설비공학논문집
    • /
    • 제22권7호
    • /
    • pp.460-467
    • /
    • 2010
  • In housing units constructed recently in Korea, the length of ondol coil is different in each room, so the flow rate of hot water is adjusted by setting valve opening. If the flow rate is not appropriate for heating load, the room temperature seriously deviates from the set temperature range for comfort. In particular, too small valve opening can induce a noise by cavitation. In order to adjust the valve opening, two methods by zone area and a new method by return temperature rise were modelled and simulated using TRNSYS and EES. As a result, heating energy consumption during one week was the same on three methods, but the room temperature of the new method minimally deviated from the range of set temperature with a low possibility of noise.

태양열이용 Baffle식 축열조를 갖는 급탕난방시스템의 열성능 해석 (Analysis of Thermal Performance of Solar Hot-Water and Heating System with Baffle Storage Tank)

  • 서정세;이중섭;윤지훈
    • 설비공학논문집
    • /
    • 제22권11호
    • /
    • pp.805-811
    • /
    • 2010
  • A numerical study has been performed to investigate the thermal performance of solar heating system with baffle type of storage tank by using the commercial code TRNSYS. As a result, the solar fraction depends strongly on the efficiency and heat loss coefficient of solar collector as well as the heating capacity of house and the water temperature supplied to the shower. In addition, the solar fraction has been basically ranked to higher level in baffle type of storage tank than typical type of single storage tank for the range of operation condition.

태양열 콤비시스템의 축열조에 적용되는 분배기의 효과 (The Effect of a Manifold in a Storage Tank Applied to a Solar Combisystem)

  • 손효석;홍희기
    • 설비공학논문집
    • /
    • 제26권7호
    • /
    • pp.322-328
    • /
    • 2014
  • Return piping is used in a solar combi-system for heating and hot water supply. When the temperature of the lower side of a storage tank is low due to hot water usage, the returned hot water after heating is mixed with the lower side cold water of the tank, and the useful energy is reduced. We studied the degree of thermal stratification in the tank, using either a diffuser or a manifold to prevent mixing. Using the diffuser, mixing starts from the bottom of the storage tank. On the other hand, the manifold has the marked effect of preventing mixing. As a result of experiments with changing the diameter and number of holes in the manifold, the optimum condition is 8.5 mm diameter and 96 holes, under the condition of 0.3 lpm.

공동주택 공기열 멀티 히트펌프의 바닥난방 성능 평가 (Performance Evaluation of Air Source Multi Heat Pump Floor Heating System in Apartment)

  • 이철희;나환선;정훈;김강식
    • 한국기계기술학회지
    • /
    • 제13권3호
    • /
    • pp.93-98
    • /
    • 2011
  • To analyze and evaluate the performance of developing air to water multi heat pump, the heat pump was installed and tested at low energy house in Daejeon, korea. Heating capacity of heat pump is 16.5KW and cooling capacity is 14.0KW. Space heating/cooling, floor heating and hot water is available. The results performance evaluation of heat pump in lab test showed that the coefficient of performance (cop) was 3.75, and heating capacity was 16.0KW in ambient temperature $7^{\circ}C$. Also at ambient temperature $-15^{\circ}C$, the COP was 1.69. At a low energy house, floor heating is controled by a floor heating water temperature and a room temperature. The COP of heat pump is decreased with frequent on/off operation for controlling of floor heating water temperature.

토마토 재배 온실의 환경조절에 따른 온습도 균일도 분석 (Analysis on the Uniformity of Temperature and Humidity According to Environment Control in Tomato Greenhouses)

  • 남상운;김영식
    • 생물환경조절학회지
    • /
    • 제18권3호
    • /
    • pp.215-224
    • /
    • 2009
  • 공기유동 제어기술의 개발을 위한 기초자료를 제공 할 목적으로 토마토 재배 온실의 냉난방과 환기 및 공기유동 관련 실태를 조사하고, 온실유형과 난방방식별 온습도 분포를 실측하여 균일도를 분석하였다. 충남 부여 세도지역의 토마토 재배 온실 136농가를 대상으로 조사한 결과 대부분을 차지하는 단동 플라스틱 온실의 천창 설치 비율이 낮고 환기팬과 유동팬 설치비율도 매우 낮을 뿐만 아니라 설치제원도 편차가 매우 큰 것으로 나타났다. 아치형 단동 플라스틱온실의 천창 환기 구조의 개발보급과 연동곡부의 천창도 지붕상부로 이동시킬 필요가 있으며, 개별 천창구조 및 환기팬과 유동팬에 대한 설치 가이드라인의 제정이 요구된다. 냉방설비를 설치한 농가는 하나도 없었으며 난방방식의 대부분을 차지하는 온풍난방에서 덕트의 설치제원 역시 편차가 큰 것으로 나타났고, 온풍덕트의 배기풍속 및 배기온도 또한 거리에 따른 편차가 매우 큰 것으로 관측되었다. 수출경쟁력 화보를 위한 고품질의 생산물을 연중 안정적으로 생산하기 위해서는 온실냉방기술의 보급이 절실하며 난방방식이나 덕트설치 방식의 개선이 필요한 것으로 판단된다. 온실내 온습도 분포가 균일한지 여부를 판단하는 지표로 사용되고 있는 최대 편차와 실제 균등한 정도를 나타낼 수 있는 균일도와의 관계를 분석해 본 결과 높은 상관관계를 보였으나 주간에는 직선식으로 야간에는 2차 곡선식으로 다르게 표현되었다. 온습도 분포의 균일한 정도를 판정할 수 있는 객관적인 기준이 마련된다면 최대편차 대신 균일도를 지표로 사용하는 것이 더 합리적일 것으로 판단된다. 온실유형과 난방방식에 따라 온 습도분포의 균일도가 상당히 다른 것을 확인할 수 있었으며 야간에는 온수난방의 경우 이랑배관으로, 온풍난방의 경우 온풍덕트의 적절한 배치를 통하여, 주간에는 환기와 공기유동을 통하여 균일도를 개선할 수 있을 것으로 판단되었다.

마이크로파를 이용한 비극성 고무컴파운드의 가황 효율 (Vulcanization Efficiency of Non-polar Rubber Compounds by Microwave)

  • 정우선;이원기;임권택
    • 폴리머
    • /
    • 제35권3호
    • /
    • pp.228-231
    • /
    • 2011
  • 열원으로 열풍과 마이크로파를 이용하여 비극성 ethylene-propylene-diene terpolymer(EPDM)/카본블랙 컴파운드 제조에 있어서 시편의 두께 및 첨가제 함량에 따른 가황속도의 영향을 비교 조사하였다. 열풍가황의 경우, 컴파운드의 두께가 가장 중요한 인자로서 EPDM의 나쁜 열전도도 특성으로 인하여 컴파운드의 두께가 증가할수록 가황속도는 느려졌으며 두께 3 mm 컴파운드의 완전 가황은 $250^{\circ}C$에서 7분 이상이 소요되었다. 반면에 마이크로파 가황에서는 컴파운드의 두께에 의한 영향은 없었으나 극성첨가제인 카본블랙 함량에 큰 영향을 받았다. 카본블랙이 80 phr 이상인 컴파운드는 30초간 마이크로파 노출에 의해 거의 100% 가황이 일어남을 확인하였다. 이러한 결과는 극성물질을 포함하는 컴파운드의 가황열원으로서 마이크로파가 효과적임을 알 수 있었다.

전기발열체 난방기 및 유류온풍 난방기의 단동온실 난방 특성 비교 (Comparison of Heating Characteristics of Electric Heating Element Heater and Oil Hot Air Heater in Single Span Greenhouses)

  • 권진경;김승희;신영안;이재한;박경섭;강연구
    • 생물환경조절학회지
    • /
    • 제26권4호
    • /
    • pp.324-332
    • /
    • 2017
  • 본 연구에서는 서로 다른 열전달 특성을 가진 탄소섬유 전기발열체와 경유온풍난방기가 온실 내부의 온습도, 에너지소비, 작물생육 등에 미치는 영향을 분석하기 위해 오이 재배 단동온실에 대한 난방 비교시험을 수행하였다. 전기발열체 온실에서 난방용량이 온실 환경과 난방기 운전에 미치는 영향을 분석하기 위해 온실에 6, 9, 16kW의 전력을 각각 공급한 결과 전기발열체 ON-OFF 주기는 각각 9, 11, 15회로 비례하여 증가하였으며 온실내부 평균온도는 각각 15.2, 15.3, $15.6^{\circ}C$, 평균상대습도는 84, 81, 76%로 나타나 난방 용량이 클수록 온실내부 온도는 높고, 상대습도는 낮게 나타났다. 또한 6, 9kW 가동 시 하부온도가 상부보다 $0.1^{\circ}C$ 높았으며 16kW 가동 시는 상부 평균온도가 하부보다 $0.2^{\circ}C$ 높았다. 전기발열체와 경유온풍난방기의 비교 시험에서는 난방 시 온실상부와 하부의 온도차가 전기발열체 온실이 $0.1{\sim}0.2^{\circ}C$로 경유온풍난방기 온실의 $0.5{\sim}0.6^{\circ}C$보다 작았으며, 온실 상류와 하류의 온도차는 전기발열체 온실이 $0{\sim}0.1^{\circ}C$로 경유온풍난방기 온실의 $1.3{\sim}1.4^{\circ}C$보다 작아 정밀한 온도관리가 가능하였다. 난방기간 동안 사용한 에너지사용량은 경유온풍난방기 온실이 경유 867L를, 전기발열체 온실이 전력량 8,959kWh를 사용하였으며, 난방비용은 각각 607천원과 403천원이 소요되어 전기발열체 온실에서 약 34%의 비용절감 효과가 있었다. 전기발열체 온실의 경우 상대적으로 군락 상하부의 환경관리가 균일하여 초장을 비롯한 전반적 생육상황이 경유온풍난방기 온실보다 좋았으나 통계적으로 유의한 차이는 없었으며, 수확량 역시 전기발열체 온실의 작물군락 하부 온도가 경유온풍난방기 온실보다 $1.3^{\circ}C$ 더 높게 관리되어 4.3% 증수효과가 있었으나 통계적으로 유의한 차이는 없었다. 원예시설의 최적 난방 관리를 위해서는 각 난방기의 열전달 특성에 기초하여 난방기 용량, 배치, 열분배 방법에 대한 설계가 요구되며, 전열선 형태의 난방기 역시 작물형상 및 재배방법을 고려하여 전열선의 개수, 위치, 방열온도 등에 대한 설계가 필요한 것으로 판단되었다.