• 제목/요약/키워드: hot air heating

검색결과 331건 처리시간 0.027초

CVD 다이아몬드가 코팅된 알루미늄 방열판의 방열 특성 (Heat Spreading Properties of CVD Diamond Coated Al Heat Sink)

  • 윤민영;임종환;강찬형
    • 한국표면공학회지
    • /
    • 제48권6호
    • /
    • pp.297-302
    • /
    • 2015
  • Nanocrystalline diamond(NCD) coated aluminium plates were prepared and applied as heat sinks for LED modules. NCD films were deposited on 1 mm thick Al plates for times of 2 - 10 h in a microwave plasma chemical vapor deposition reactor. Deposition parameters were the microwave power of 1.2 kW, the working pressure of 90 Torr, the $CH_4/Ar$ gas ratio of 2/200 sccm. In order to enhance diamond nucleation, DC bias voltage of -90 V was applied to the substrate during deposition without external heating. NCD film was identified by X-ray diffraction and Raman spectroscopy. The Al plates with about 300 nm thick NCD film were attached to LED modules and thermal analysis was carried out using Thermal Transient Tester (T3ster) in a still air box. Thermal resistance of the module with NCD/Al plate was 3.88 K/W while that with Al plate was 5.55 K/W. The smaller the thermal resistance, the better the heat emission. From structure function analysis, the differences between junction and ambient temperatures were $12.1^{\circ}C$ for NCD/Al plate and $15.5^{\circ}C$ for Al plate. The hot spot size of infrared images was larger on NCD/Al than Al plate for a given period of LED operation. In conclusion, NCD coated Al plate exhibited better thermal spreading performance than conventional Al heat sink.

제주 시설온실 냉난방을 위한 발전소 온배수 활용 열펌프 시스템 구축 및 냉방성능 평가 (Construction of the Heat Pump System Using Thermal Effluents for Greenhouse Facilities in Jeju and Evaluation of Cooling Performance)

  • 이연건;허재혁;이동원;현명택
    • 에너지공학
    • /
    • 제27권4호
    • /
    • pp.70-79
    • /
    • 2018
  • 한국중부발전 제주화력본부에서 방류되는 온배수로부터 열원을 회수하여 약 3 km의 원거리에 위치하고 있는 신촌백합영농조합법인의 시설온실에 냉온수를 공급하기 위한 300 RT 용량의 열펌프 시스템을 구축하였다. 원거리 시설로 온배수열을 공급하기 위한 최적화 방안을 도출하였고, 수송관로의 온도와 누수여부를 모니터링하기 위한 설비들이 설치되었다. 본 논문에서는 제주 시설온실 냉난방을 위한 발전소 온배수 활용 열펌프 시스템의 구성과 주요기기에 대해 기술하였다. 2018년 하절기에 열펌프 시스템의 냉방성능을 평가하기 위한 실증운전을 수행하였다. 냉방운전 시 열펌프 시스템의 주요 위치에서 측정된 유체의 온도와 유량, 그리고 냉방 성능계수를 분석하여, 구축된 열펌프 시스템의 안정성과 냉방성능을 검증하였다.

Water Sorption/Desorption Characteristics of Eutectic LiCl-KCl Salt-Occluded Zeolites

  • Harward, Allison;Gardner, Levi;Oldham, Claire M. Decker;Carlson, Krista;Yoo, Tae-Sic;Fredrickson, Guy;Patterson, Michael;Simpson, Michael F.
    • 방사성폐기물학회지
    • /
    • 제20권3호
    • /
    • pp.259-268
    • /
    • 2022
  • Molten salt consisting primarily of eutectic LiCl-KCl is currently being used in electrorefiners in the Fuel Conditioning Facility at Idaho National Laboratory. Options are currently being evaluated for storing this salt outside of the argon atmosphere hot cell. The hygroscopic nature of eutectic LiCl-KCl makes is susceptible to deliquescence in air followed by extreme corrosion of metallic cannisters. In this study, the effect of occluding the salt into a zeolite on water sorption/desorption was tested. Two zeolites were investigated: Na-Y and zeolite 4A. Na-Y was ineffective at occluding a high percentage of the salt at either 10 or 20wt% loading. Zeolite-4A was effective at occluding the salt with high efficiency at both loading levels. Weight gain in salt occluded zeolite-4A (SOZ) from water sorption at 20% relative humidity and 40℃ was 17wt% for 10% SOZ and 10wt% for 20% SOZ. In both cases, neither deliquescence nor corrosion occurred over a period of 31 days. After hydration, most of the water could be driven off by heating the hydrated salt occluded zeolite to 530℃. However, some HCl forms during dehydration due to salt hydrolysis. Over a wide range of temperatures (320-700℃) and ramp rates (5, 10, and 20℃ min-1), HCl formation was no more than 0.6% of the Cl- in the original salt.

태양열 집열관 과열방지를 위한 지중열교환기 연구 (A study of geothermal heat dump for solar collectors overheat protection)

  • 황현창;;이계복;이석호
    • 한국산학기술학회논문지
    • /
    • 제17권7호
    • /
    • pp.616-622
    • /
    • 2016
  • 하절기 줄어드는 온수부하는 태양열 집열기 과열의 주된 원인이다. 과열방지목적으로 공냉 또는 차단막이 사용되는데 이는 추가적인 기계적요소를 필요하게 되고 장기 운용 시 파손 등의 우려에 따라 그 신뢰도도 크게 저하된다. 지중열교환기는 지열을 열원으로 방열 또는 흡열을 진행하는데, 지열을 고 열원으로 하여 흡열을 목적으로 하는 연구가 대다수이며 지열원이 저열원으로 이용하는 방열에 대한 연구는 부족한 편이다. 그리하여 본 연구에서는 태양열집열판의 과열방지를 목적으로 하는 지중열교환기의 가능성 및 그 성능에 대한 연구를 진행하였다. 여름철 최대 $150^{\circ}C$이상의 고온을 유지하는 태양열집열판의 열을 방출하기 위하여 1.2m의 하부 깊이를 갖는 50m 나선형 지중열교환기를 설치하였고 이를 통해 순간 냉각이 가능한 것으로 확인되었으며, 태양열집열판의 여름철 과열에 의한 파손을 방지할 수 있었다. 그리고 다양한 변수에 대한 이론적인 계산을 통하여 0.33kg/s의 최저 순환유량만 유지해주면 지열 열교환기의 길이에 따른 방열효과에 큰 영향을 미치지 않음을 판단할 수 있다. 또한 축열조와의 공동 사용시 냉각효과는 여름철 과열시 충분한 과열방지 제어가 가능한 것으로 조사되었다.

일반시장에서 튀김식품에 사용된 기름의 화학적 변화 (Chemical Changes of the Deep Fat Frying Oils Used Commercially)

  • 주광지;하계숙
    • 한국식품영양과학회지
    • /
    • 제18권3호
    • /
    • pp.247-254
    • /
    • 1989
  • 튀김 식품에 사용되는 기름들은 반복적으로 높은 온도에서 계속하여 사용되므로 튀김기름이 산패 중합되어서 인체에 해를 끼칠 수가 있다. 그러나 현재 사용하던 기름에 대한 폐기처분이나 어떤 법적인 규제가 없다. 이 연구보고서는 일반시장에서 반복하여 사용된 기름에 새 기름을 첨가하여 사용한 기름과 가정용 기름을 시료로 하여 유지의 일반성 상과 가열시간에 따르는 유지의 변화를 조사하여 다음과 같은 결과를 얻었다. 일반시장에서 몇가지 튀김식품에 사용되는 기름은 가정용 튀김기름보다 그 품질면에서 열등하였다. 또한 가열하기전 신선한 기름 그 자체가 정제식용유의 규격기준에 미달되었다. 튀김기름은 튀김횟수가 증가하고 가열시간이 증가함에따라 유리지방산가, 과산화물가와 요오드가의 증가 또는 감소등으로 유지 산패의 전형적인 특징을 나타내다가 신선한 기름의 첨가로 가열전 기름의 수준으로 환원되어졌다. 튀김기름속에 잔존하는 비휘발성 극성성분의 함량은 가열시간이 증가함에 따라 신선한 기름의 첨가에 관계없이 증가하였으며 가열 22시간 후에는 극성성분의 함량이 산패된 기름의 수준까지 이르렀다. 튀김기름의 지방산 조성은 가열시간이 경과함에 따라 팔미친산, 스테아린산 함량의 비율은 증가하였고 리놀레인산, 리놀레닌산은 그 함량이 각각 감소하였다. 채종유중 고에루신산 채종유는 다량의 에루신산을 함유하고 있으므로 식용에 부적합하다고 할 수 있다.

  • PDF

박형 태양 전지 모듈화를 위한 레이져 태빙 자동화 공정(장비) 개발 (Development on New Laser Tabbing Process for Modulation of Thin Solar Cell)

  • 노동훈;최철준;조헌영;유재민;김정근
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.58.1-58.1
    • /
    • 2010
  • In solar cell module manufacturing, single solar cells has to be joined electrically to strings. Copper stripes coated with tin-silver-copper alloy are joined on screen printed silver of solar cells which is called busbar. The bus bar collects the electrons generated in solar cell and it is connected to the next cell in the conventional module manufacturing by a metal stringer using conventional hot air or infrared lamp soldering systems. For thin solar cells, both soldering methods have disadvantages, which heats up the whole cell to high temperatures. Because of the different thermal expansion coefficient, mechanical stresses are induced in the solar cell. Recently, the trend of solar cell is toward thinner thickness below 180um and thus the risk of breakage of solar cells is increasing. This has led to the demand for new joining processes with high productivity and reduced error rates. In our project, we have developed a new method to solder solar cells with a laser heating source. The soldering process using diode laser with wavelength of 980nm was examined. The diode laser used has a maximum power of 60W and a scanner system is used to solder dimension of 6" solar cell and the beam travel speed is optimized. For clamping copper stripe to solar cell, zirconia(ZrO)coated iron pin-spring system is used to clamp both joining parts during a scanner system is traveled. The hot plate temperature that solar cell is positioned during lasersoldering process is optimized. Also, conventional solder joints after $180^{\circ}C$ peel tests are compared to the laser soldering methods. Microstructures in welded zone shows that the diffusion zone between solar cell and metal stripes is better formed than inIR soldering method. It is analyzed that the laser solder joints show no damages to the silicon wafer and no cracks beneath the contact. Peel strength between 4N and 5N are measured, with much shorter joining time than IR solder joints and it is shown that the use of laser soldering reduced the degree of bending of solar cell much less than IR soldering.

  • PDF

불활성 가스하 열건조에 따른 금속시험편의 수소잔류물 거동 분석 (Variation of Hydrogen Residue on Metallic Samples by Thermal Soaking in an Inert Gas Environment)

  • 이윤희;박종서;백운봉;남승훈
    • 한국수소및신에너지학회논문집
    • /
    • 제24권1호
    • /
    • pp.44-49
    • /
    • 2013
  • Hydrogen penetration into a metal leads to damages and mechanical degradations and its content measurement is of importance. For a precise measurement, a sample preparation procedure must be optimized through a series of studies on sample washing and drying. In this study, two-step washing with organic solvents and thermal soaking in inert gas were tried with a rod-shaped, API X65 steel sample. The samples were machined from a steel plate and then washed in acetone and etyl-alcohol for 5 minute each and dried with compressed air. After then, the samples were thermally soaked in a home-made nitrogen gas chamber during 10 minute at different heat gun temperatures from 100 to $400^{\circ}C$ and corresponding temperature range in the soaking chamber was from 77 to $266^{\circ}C$ according to the temperature calibration. Hydrogen residue in the samples was measured with a hot extraction system after each soaking step; hydrogen residue of $0.70{\pm}0.12$ wppm after the thermal soaking at $77^{\circ}C$ decayed with increase of the soaking temperature. By adopting the heat transfer model, decay behavior of the hydrogen residue was fitted into an exponential decay function of the soaking temperature. Saturated value or lower bound of the hydrogen residue was 0.36 wppm and chamber temperature required to lower the hydrogen residue about 95% of the lower bound was $360^{\circ}C$. Furthermore, a thermal desorption spectroscopy was done for the fully soaked samples at $360^{\circ}C$. Weak hydrogen peak was observed for whole temperature range and it means that hydrogen-related contaminants of the sample surface are steadily removed by heating. In addition, a broad peak found around $400^{\circ}C$ means that parts of the hydrogen residue are irreversibly trapped in the steel microstructure.

전남 지방에 있어서의 양송이 재배에 최적한 환경조건 조절법 분석에 관한 연구 (Study on the Controlling Mechaniques of the Environmental Factors in the Mushroom Growing House in Chonnam Province)

  • 정병재;이은철
    • Journal of the Korean Wood Science and Technology
    • /
    • 제2권2호
    • /
    • pp.32-34
    • /
    • 1974
  • 본 논문은 1968년 과학기술처 Trust Fund에 의하여 실시된 연구로서 전남 지방에 있어서 최적합한 양송이 재배사를 구명하기 위하여 이미 구미에서 연구된 결과를 토대로 하여 우리나라의 기후적 조건과 경제적 조건을 고찰한 자연공기 순환법을 적용, 양송이 재배에 최적한 환경 조건과 이의 조절법을 구명코저 시상식재배사와 지하실에 구축한 태양열을 이용하는 태양열식 재배사를 본실험용으로 구축하고 전자에 대하여서는 외가의 온도의 영향을 받지 아니하는 측벽구조와 천정의 구조, 환기구의 위치 및 그 환기량등에 관하여 검토하였으며 후자에 관하여는 태양열 이용 효과에 대하여 검토하였다. 또한 동기에 있어서의 계속적 재배를 가능케 하기 위하여 양송이 재배사의 보온에 적합한 가열 장치에 대하여서도 검토하였다. 1. 실험용 지상식 양송이 재배사의 효과에 관하여는 이미 실험결과 및 그 분석에서 지적된 바 있거니와 그 측벽 및 천정의 구조는 재배사를 외계의 기상조건에서 격리하는데 충부한 효과가 있는 것으로 고려된다. 2. 반지하실에 구축한 실험용 태양식 양송이 재배사의 효과에 관하여는 실험결과 및 그 분석에 지적한 바와 같거니와 태양열을 이용하는데 있어 충분한 효과가 있는 것으로 고려된다. 그러나 이것을 농가에 적용하기 위하여는 다음과 같은 제점이 개선되어야 할 것으로 고려된다. 즉 (1) 태양식의 지붕과 천정은 실험용 지상식재배사의 그것과 동일히 하고, (2) 태양열 수열 장치는 적당히 제고되어야 할 것으로 고려된다. 3. 본 실험 연구에서 실시한 각조의 환기법중 GE-CV 및 VS-CV 환기법이 가장 효과적인 것으로 본다. 4. 측벽수치 및 지중 환기장치는 이미 지적한 바와 같이 농가용 양송이재배사의 자연환기법으로 실용적 가치가 충분하다. 그것은 이들 환기장치는 그 환기로를 통하여 사내에 유입되는 외기의 온도를 인공적으로 가열이나 또는 냉각하지 않고 사내 온도에 접근하지 않도록 조절하는 효과가 있기 때문이다. 지금 외온을 $X^{\circ}C$로 할때 각종 환기로에 의하여 흡수되는 온도 $Y^{\circ}C$를 X의 함수로 하는 실험식은 다음과 같이 회귀직선으로 표시된다. GP$\cdots$Y=0.9X-12.8 GE$\cdots$Y=0.96X-15.11 VS$\cdots$Y=0.94X-17.57 5. 재배사내에 유입되는 공기 및 사외로 배출되는 공기에 관한 실험식은 다음과 같이 회귀직선 및 지수곡선으로 표시된다. 5.1 배출속도 Ycm/sec.를 유입속도 Xcm/sec.의 함수로 하는 회귀직선식 GE-CV(50%)법$\cdots$Y=1.0X-1.65 GE-CV(100%)법$\cdots$Y=0.42X+2.03 VS-CV(100%)법$\cdots$Y=0.85X+0.96 5.2 배출량 $Ym^3$/hr.를 유출량${\times}m^3$/hr.의 함수로 하는 회귀직선식 GE-CV(50%)법$\cdots$Y=2.59X-10.88 GE-CV(100%)법$\cdots$Y=2.16X+26.53 5.3 상면 공기이동 속도 Ym/sec.를 배출공기 속도${\times}m$/sec.의 함수로 하는 회귀직선식 GE-CV(50%)법$\cdots$Y=0.5X+0.84 5.4 $CO_2$ 축적량 Y(%)를 상면공기이동속도 cm/sec.의 함수로 하는 회귀직선식 GE-CV(50%)$\cdots$Y=114.53-6.42X 5.5 $CO_2$ 축적량Y(%)를 배출공기량 $m^3$/hr.의 함수로 하는 지수곡선식 GE-CV(50%)$\cdots$Y=$127.18{\times}1.0093^{-x}$ 5.6 Natural ventilation system에 있어서 양송이 생육에 적합한 환경적조건을 마련하기 위한 환기구의 단면적은 재배사 전용적에 대하여 다음과 같은 비율로할 수 있다. GE(지중유입 환기구 단면적)$\cdots$0.3-0.5%(요조절) CV(천정배출 환기구 단면적)$\cdots$0.8-1.0% (요조절) 6. 본 연구에서 실험한 각종의 가열장치중 무압증기수 보이라도 사요할 수 있는 온수 보이라가 농가용 양송이재배사 가열장치로서, 그 효과면에 있어서나 또는 그 가격면에 있어서 최적합다하는 것이 확인되고 있다.

  • PDF

제주지역 직장어린이집 보육실의 겨울철 실내온열환경 실태 (Winter Indoor Thermal Environment Status of Nursery Rooms in Workplace Daycare Centers in Jeju Island)

  • 김봉애;고연숙
    • 대한건축학회논문집:구조계
    • /
    • 제33권12호
    • /
    • pp.81-90
    • /
    • 2017
  • This study was conducted to investigate the thermal environment status of nursery rooms in workplace daycare centers in Jeju and propose measures to improve their indoor physical thermal environment. For this purpose, measurements were performed in the winter indoor physical environment of 51 nursery rooms in 11 workplace daycare centers and a psychological evaluation survey on the thermal environment of nursery rooms was conducted for 70 nursery teachers. The investigation was carried out over 11 days in January 2017. The results are as follow. The average indoor temperature of the nursery rooms was $21.3^{\circ}C$($18.7-23.8^{\circ}C$) and the indoor temperatures of 47 nursery rooms (92.9%) were higher than the environmental hygiene management standard for domestic school facilities ($18-20^{\circ}C$). The average relative humidity was 33.9% (16.4-56.0%), and 37 nursery rooms (86.3%) showed a lower average relative humidity than the standard (40-70%). The average absolute humidity was $9.1g/m^3$ ($4.7-13.6g/m^3$), which was lower than the standard for preventing influenza ($10g/m^3$). When the indoor temperature and humidity of the nursery rooms were compared with international standards, it was found that 85% or more of the 51 nursery rooms maintained appropriate indoor temperatures, but 40-50% of the nursery rooms maintained a low humidity condition. Therefore, they need to pay attention to maintaining the appropriate humidity of the nursery room to keep the children healthy. The average indoor temperature of the nursery rooms showed a weak negative correlation with the average relative humidity. The indoor temperature had a significant effect on the relative humidity: a higher indoor temperature resulted in lower relative humidity. Regarding the fluctuations in the average indoor temperature of the nursery rooms during the day, in daycare centers that used floor heating, the indoor temperature gradually increased form the morning to the afternoon and tended to decrease during lunch time and the morning and afternoon snack times, due to ventilation. The daycare centers that used both floor heating and ceiling-type air conditioners showed a higher indoor temperature and greater fluctuations in temperature compared to the daycare centers that used floor heating only. In the survey results, the average value of the whole body thermal sensation was 3.0 (neutral): 32 respondents (62.7%) answered, "Neutral", Which was the largest number, followed by 21 respondents (30%) who answered, "Slightly hot" and 17 respondents (24.2%) who answered, "Slightly cold." Twenty-nine respondents answered, "Slightly dry," which was the largest number, followed by 28 respondents (54.9%) who answered, "Neutral" and 10 respondents (19.6%) who answered, "Dry." The total number of respondents who answered, "Slightly dry" or "Dry" was large at 39 (56.4%), which suggests the need for indoor environment management to prevent a low-humidity environment. To summarize the above results about the thermal environment of nursery rooms, as the indoor temperature increased, the relative humidity decreased. This suggests the effect of room temperature on the indoor relative humidity; however, frequent ventilations also greatly decrease the relative humidity. Therefore, the ventilation method and the usage of air conditioning systems need to be re-examined.

곡물냉각기의 개발 (Development of a New Commercial Grain Cooler)

  • 김동철;김의웅;금동혁;한종규
    • 한국식품저장유통학회지
    • /
    • 제11권2호
    • /
    • pp.250-256
    • /
    • 2004
  • 국내의 기상조건 및 벼의 수확후 처리여건에 적합한 곡물냉각기를 개발하고, 냉각능력, 재열능력, 가열능력, 소요전력 및 성능계수 등의 성능을 측정하여 설계조건에 적합한지를 분석하였다. 그 결과를 요약하면 다음과 같다. 압축기 무부하전자변과, 재열기 및 증발기에 고온고압의 냉매가스를 공급하여 냉각능력을 0∼100%까지 제어할 수 있고, 온도 5$^{\circ}C$이상, 상대습도 54∼95%의 정온정습 공기를 발생할 수 있는 1일 최대 벼 200톤을 냉각할 수 있는 곡물냉각기를 개발하였다. 이 곡물냉각기의 최대냉각능력은 35,284㎉/hr, 송풍량 및 정압은 각각 120㎥/min, 279mmAq이었으며, 재열기를 통한 냉각공기의 최대 온도상승 및 상대습도의 저하범위는 각각 7.6∼8.6$^{\circ}C$, 34.5∼41.0%이었으며, 최대가열능력은 5.6$^{\circ}C$이었다. 또한, 최대 소요동력은 22.8㎾이었으나, 압축기의 무부하 전자변이 작동될 때는 총소요동력의 33.3%, 압축기 소요축동력의 44.7%가 절약되는 것으로 나타났으며, 제어조건에 따라 전체소요동력의 26.7~33.3%정도가 절약되는 것으로 나타났으며, 냉동시스템의 성능계수는 과냉각으로 인해 표준냉동사이클하에서의 4.0보다 높은 4.71이었으며, 전성능계수는 1.8로 나타났다.