• 제목/요약/키워드: hospital-based

검색결과 10,034건 처리시간 0.04초

일본 '고증파(考證派)' 의학에 관한 연구 (A Study on The 'Kao Zheng Pai'(考證派) of The Traditional Medicine of Japan)

  • 박현국;김기욱
    • 동국한의학연구소논문집
    • /
    • 제10권
    • /
    • pp.1-40
    • /
    • 2008
  • 1.The 'Kao Zheng Pai'(考證派) comes from the 'Zhe Zhong Pai(折衷派)' and is a school that is influenced by the confucianism of the Qing dynasty. In Japan Inoue Kinga(井上金峨), Yoshida Koton(古田篁墩 $1745{\sim}1798$) became central members, and the rise of the methodology of historical research(考證學) influenced the members of the 'Zhe Zhong Pai', and the trend of historical research changed from confucianism to medicine, making a school of medicine based on the study of texts and proving that the classics were right. 2. Based on the function of 'Nei Qu Li'(內驅力) the 'Kao Zheng Pai', in the spirit of 'use confucianism as the base', researched letters, meanings and historical origins. Because they were influenced by the methodology of historical research(考證學) of the Qing era, they valued the evidential research of classic texts, and there was even one branch that did only historical research, the 'Rue Xue Kao Zheng Pai'(儒學考證派). Also, the 'Yi Xue Kao Zheng Pai'(醫學考證派) appeared by the influence of Yoshida Kouton and Kariya Ekisai(狩谷掖齋). 3. In the 'Kao Zheng Pai(考證派)'s theories and views the 'Yi Xue Kao Zheng Pai' did not look at medical scriptures like the "Huang Di Nei Jing"("黃帝內經") and did not do research on 'medical' related areas like acupuncture, the meridian and medicinal herbs. Since they were doctors that used medicine, they naturally were based on 'formulas'(方劑) and since their thoughts were based on the historical ideologies, they valued the "Shang Han Ja Bing Lun" which was revered as the 'ancestor of all formulas'(衆方之祖). 4. The lives of the important doctors of the 'Kao Zheng Pai' Meguro Dotaku(目黑道琢) Yamada Seichin(山田正珍), Yamada Kyoko(山田業廣), Mori Ritsi(森立之) Kitamura Naohara(喜多村直寬) are as follows. 1) Meguro Dotaku(目黑道琢 $1739{\sim}1798$) was born of lowly descent but, using his intelligence and knowledge, became a professor as a Shi Jing Yi(市井醫) and as a professor for 34 years at Ji Shou Guan(躋壽館) mastered the "Huang Di Nei Jing" after giving over 300 lectures. Since his pupil, Isawara Ken(伊澤蘭軒) taught the Lan Men Wu Zhe(蘭門五哲) and Shibue Chusai(澀江抽齋), Mori Ritsi(森立之), Okanishi Gentei(岡西玄亭), Kiyokawa Gendoh(淸川玄道) and Yamada Kyoko(山田業廣), Meguro Dotaku is considered the founder of the 'Yi Xue Kao Zheng Pai'. 2) The family of Yamada Seichin(山田正珍 $1749{\sim}1787$) had been medical officials in the Makufu(幕府) and the many books that his ancestors had left were the base of his art. Seichin learned from Shan Ben Bei Shan(山本北山), a 'Zhe Zhong Pai' scholar, and put his efforts into learning, teaching and researching the "Shang Han Lun"("傷寒論"). Living in a time between 'Gu Fang Pai'(古方派) member Nakanishi Goretada(中西惟忠) and 'Kao Zheng Pai' member Taki Motohiro(多紀元簡), he wrote 11 books, 2 of which express his thoughts and research clearly, the "Shang Han Lun Ji Cheng"("傷寒論集成") and "Shang Han Kao"("傷寒考"). His comparison of the 'six meridians'(3 yin, 3 yang) between the "Shang Han Lun" and the "Su Wen Re Lun"("素問 熱論") and his acknowledgement of the need and rationality of the concept of Yin-Yang and Deficient-Replete distinguishes him from the other 'Gu Fang Pai'. Also, his dissertation of the need for the concept doesn't use the theories of latter schools but uses the theory of the "Shang Han Lun" itself. He even researched the historical parts, such as terms like 'Shen Nong Chang Bai Cao'(神農嘗百草) and 'Cheng Qi Tang'(承氣湯). 3) The ancestor of Yamada Kyoko(山田業廣) was a court physician, and learned confucianism from Kao Zheng Pai's Ashikawa Genan(朝川善庵) and medicine from Isawa Ranken(伊澤蘭軒) and Taki Motokata(多紀元堅), and the secret to smallpox from Ikeda Keisui(池田京水). He later became a lecturer at the Edo Yi Xue Guan(醫學館) and was invited as the director to the Ji Zhong(濟衆) hospital. He also became the first owner of the Wen Zhi She(溫知社), whose main purpose was the revival of kampo, and launched the monthly magazine Wen Zi Yi Tan(溫知醫談). He also diagnosed and prescribed for the prince Ming Gong(明宮). His works include the "Jing Fang Bian"("經方辨"), "Shang Han Lun Si Ci"("傷寒論釋詞"), "Huang Zhao Zhu Jia Zhi Yan Ji Yao"("皇朝諸家治驗集要") and "Shang Han Ja Bing Lun Lei Juan"("傷寒雜病論類纂"). of these, the "Jing Fang Bian"("經方辨") states that the Shi Gao(石膏) used in the "Shang Han Lun" had three meanings-Fa Biao(發表), Qing Re(淸熱), Zi Yin(滋陰)-which were from 'symptoms', and first deducted the effects and then told of the reason. Another book, the "Jiu Zhe Tang Du Shu Ji"("九折堂讀書記") researched and translated the difficult parts of the "Shang Han Lun", "Jin Qui Yao Lue"("金匱要略"), "Qian Jin Fang"("千金方"), and "Wai Tai Mi Yao"("外臺秘要"). He usually analyzed the 'symptoms' of diseases but the composition, measurement, processing and application of medicine were all in the spectrum of 'analystic research' and 'researching analysis'. 4) The ancestors of Mori Ritsi(森立之 $1807{\sim}1885$) were warriors but he became a doctor by the will of his mother, and he learned from Shibue Chosai(澁江抽齋) and Isawaran Ken(伊澤蘭軒) and later became a pupil of Shou Gu Yi Zhai(狩谷掖齋), a historical research scholar. He then became a lecturer of medical herbs at the Yi Xue Guan, and later participated in the proofreading of "Yi Xin Fang"("醫心方") and with Chosai compiled the "Jing Ji Fang Gu Zhi"("經籍訪古志"). He visited the Chinese scholar Yang Shou Jing(楊守敬) in 1881 and exchanged books and ideas. Of his works, there are the collections(輯複本) of "Shen Nong Ben Cao Jing"("神農本草經") and "You Xiang Yi Hwa"("遊相醫話") and the records, notes, poems, and diaries such as "Zhi Yuan Man Lu"("枳園漫錄") and "Zhi Yuan Sui Bi"(枳園隨筆) that were not published. His thoughts were that in restoring the "Shen Nong Ben Cao Jing", "the herb to the doctor is like the "Shuo Wen Jie Zi"(說文解字) to the scholar", and he tried to restore the ancient herbal text using knowledge of medicine and investigation(考據), Also with Chosai he compiled the "Jing Ji Fang Gu Zhi"("經籍訪古志") using knowledge of ancient text. Ritzi left works on pure investigation, paid much attention to social problems, and through 12 years of poverty treated all people and animals in all branches of medicine, so he is called a 'half confucianist half doctor'(半儒半醫). 5) Kitamurana Ohira(喜多村直寬, $1804{\sim}1876$) learned scriptures and ancient texts from confucian scholar Asaka Gonsai(安積艮齋), and learned medicine from his father Huai Yaun(槐園), He became a teacher in the Yi Xue Guan in his middle ages, and to repay his country, he printed 266 volumes of "Yi Fang Lei Ju"("醫方類聚") and 1000 volumes of "Tai Ping Yu Lan"("太平禦覽") and devoted it to his country to be spread. His works are about 40 volumes including "Jin Qui Yao Lue Shu Yi"("金匱要略疏義") and "Lao Yi Zhi Yan"(老醫巵言) but most of them are researches on the "Shang Han Za Bing Lun". In his "Shang Han Lun Shu Yi"("傷寒論疏義") he shows the concept of the six meridians through the Yin-Yang, Superficial or internal, cold or hot, deficient or replete state of diseases, but did not match the names with the six meridians of the meridian theory, and this has something in common with the research based on the confucianism of Song(宋儒). In clinical treatment he was positive toward old and new methods and also the experience of civilians, but was negative toward western medicine. 6) The ancestor of the Taki family Tanbano Yasuyori(丹波康賴 $912{\sim}955$) became a Yi Bo Shi(醫博士) by his medical skills and compiled the "Yi Xin Fang"("醫心方"). His first son Tanbano Shigeaki(丹波重明) inherited the Shi Yao Yuan(施藥院) and the third son Tanbano Masatada(丹波雅忠) inherited the Dian You Tou(典藥頭). Masatada's descendents succeeded him for 25 generations until the family name was changed to Jin Bao(金保) and five generations later it was changed again to Duo Ji(多紀). The research scholar Taki Motohiro was in the third generation after the last name was changed to Taki, and his family kept an important part in the line of medical officers in Japan. Taki Motohiro(多紀元簡 $1755{\sim}1810$) was a teacher in the Yi Xue Guan where his father was residing, and became the physician for the general Jia Qi(家齊). He had a short temper and was not good at getting on in the world, and went against the will of the king and was banished from Ao Yi Shi(奧醫師). His most famous works, the "Shang Han Lun Ji Yi"("傷寒論輯義") and "Jin Qui Yao Lue Ji Yi"("金匱要略輯義") are the work of 20 years of collecting the theories of many schools and discussing, and is one of the most famous books on the "Shang Han Lun" in Japan. "Yi Sheng"("醫勝") is a collection of essays on research. Also there are the "Su Wen Shi"(素問識), "Ling Shu Shi"("靈樞識"), and the "Guan Ju Fang Yao Bu"("觀聚方要補"). Taki Motohiro(多紀元簡)'s position was succeeded by his third son Yuan Yin(元胤 $1789{\sim}1827$), and his works include works of research such as "Nan Jing Shu Jeng"(難經疏證), "Ti Ya"("體雅"), "Yao Ya"("藥雅"), "Ji Ya"(疾雅), "Ming Yi Gong An"(名醫公案), and "Yi Ji Kao"(醫籍考). The "Yi Ji Kao" is 80 volumes in length and lists about 3000 books on medicine in China before the Qing Dao Guang(道光), and under each title are the origin, number of volumes, state of existence, and, if possible, the preface, Ba Yu(跋語) and biography of the author. The younger sibling of Yuan Yin(元胤 $1789{\sim}1827$), Yuan Jian(元堅 $1795{\sim}1857$) expounded ancient writings at the Yi Xue Guan only after he reached middle age, was chosen for the Ao Yi Shi(奧醫師) and later became a Fa Yan(法眼), Fa Yin(法印) and Yu Chi(禦匙). He left about 15 texts, including "Su Wen Shao Shi"("素問紹識"), "Yi Xin Fang"("醫心方"), published in school, "Za Bing Guang Yao"("雜病廣要"), "Shang Han Guang Yao"("傷寒廣要"), and "Zhen Fu Yao Jue"("診腹要訣"). On the Taki family's founding and working of the Yi Xue Guan Yasuka Doumei(矢數道明) said they were "the people who took the initiative in Edo era kampo medicine" and evaluated their deeds in the fields of 'research of ancient text', the founding of Ji Shou Guan(躋壽館) and medical education', 'publication business', 'writing of medical text'. 5. The doctors of the 'Kao Zheng Pai' based their operations on the Edo Yi Xue Guan, and made groups with people with similar ideas to them, making a relationship 'net'. For example the three families of Duo Ji(多紀), Tang Chuan(湯川) and Xi Duo Cun(喜多村) married and adopted with and from each other and made prefaces and epitaphs for each other. Thus, the Taki family, the state science of the Makufu, the tendency of thinking, one's own interests and glory, one's own knowledge, the need of the society all played a role in the development of kampo medicine in the 18th and 19th century.

  • PDF

고립성 폐결절에 대한 진단적 접근 : 악성결절과 양성결절의 감별 지표에 대한 재검토 (Diagnostic Approach to the Solitary Pulmonary Nodule : Reappraisal of the Traditional Clinical Parameters for Differentiating Malignant Nodule from Benign Nodule)

  • 고원중;김철현;장승훈;이재호;유철규;정희순;김영환;한성구;심영수
    • Tuberculosis and Respiratory Diseases
    • /
    • 제43권4호
    • /
    • pp.500-518
    • /
    • 1996
  • 연구배경 : 고립성 폐결절에서 연령, 흡연력, 과거 암 발생력 등의 임상적 특징과 크기, 석회화, 성장속도, 전산화단층촬영 소견 등의 방사선학적 특징이 악성결절과 양성결절의 감별점으로 제시되고 있다. 하지만 알려진 대부분의 감별점은 전산화단층촬영이 광범위하게 보급되기 이전의 자료 그리고 폐암이 현재와 같이 높은 발생률을 보이기 이전의 자료를 토대로 한 것이다. 또한 이를 토대로 한 진단적 접근이 결핵종이 상대적으로 많은 국내에서도 마찬가지로 적용될 수 있을 지에 대해서는 잘 알려져 있지 않다. 악성결절과 양성결절의 감별점으로 제시되는 여러 임상적, 방사선학적 특징과 경피적 흡인세침검사, 외과적 절제술 등 여러 진단방법의 임상적 의의를 재평가하고자 하였다. 방법 : 1994년 1월부터 1995년 2월까지 서울대학교병원에 입원한 고립성 폐결절 환자 113명중 결절의 원인이 확인된 94명을 대상으로 후향적 연구를 시행하였다. 결과 : (1) 113례중 94례에서 원인질환이 확인되었다. 악성결절이 60례였고 이중 기관지암종이 49례였으며 선암이 30례로 기관지암종의 대부분을 차지하였다. (2) 악성결절을 가진 환자의 평균연령($58.1{\pm}10.0$세)이 양성결절을 가진 환자($49.7{\pm}12.0$세)에 비해 높았으며(p=0.0004), 연령증가에 따라 악성결절이 차지하는 비율이 직선적으로 증가하였다. (3) 흡연력은 양성결절을 가진 환자($13.0{\pm}17.6$갑년)과 악성결절을 가진 환자($18.5{\pm}25.1$갑년)에서 유의한 차이가 없었다(p=0.2108). (4) 과거력상 암발생력이 있었던 10례중 9례가 악성결절이었으며, 이중 5례는 이전의 암과는 무관하게 새로이 발생한 원발성 폐암이었다. (5)결절의 평균크기는 양성결절($3.01{\pm}1.20cm$)과 악성결절($2.98{\pm}0.97cm$)에서 유의한 차이가 없었다(p=0.8937). (6) 용적배가시간을 구할 수 있었던 22례중 용적배가시간이 400일이상인 결절 9례중 악성결절이 6례였다. (7) 흉부 전산화단층촬영상 분엽성 또는 침상형 변연, 공기기관지음영, 결절과 흉막사이의 선상음영, 림프절 증대 등을 보이는 경우 악성결절을 보다 더 시사할 수 있었다. 결절 내부의 석회화, 내부 저음영, 결절내부 공동의 벽두께가 균일한 경우, 경계가 잘 지어진 변연, 결절주위 폐실질의 위성병소 등은 양성결절을 시사할 수 있었다. (8) 경피적 흡인세침검사를 통하여 양성결절의 57.6%(19/33)와 악성결절의 81.0%(47/58)를 진단하였다. 양성결절 2례와 악성결절 1례에서 풍요한 진단적 뒤바뀜이 있었다. (9) 수술전 진단이 되지 않은 상태에서 외과적 절제술을 시행한 26례중 11례(42.3%)가 악성결절이었다. 외과적 절제술을 시행한 전체 61례중 악성결절은 46례(75.4%)였다. 결론: 연령이 높을수록, 과거력상 암발생력이 있는 경우, 흉부전산화단층촬영상 분엽성 또는 침상형 변인, 공기기관지음영, 결절과 흉막사이의 선상음영, 림프절 증대 등을 보이는 경우 악성결절을 보다 더 시사할 수 있을 것으로 보인다. 하지만 현재까지 고립성 폐결절에서 악성결절과 양성결절을 감별할 수 있는 지표로 여겨졌던 흡연여부나 흡연량, 결절의 크기, 용적배가시간 등은 악성결절과 양성결절의 감별에 도움이 되지 않았다. 국내에서도 원발성 폐암의 빈도가 급속히 증가하고 있는 현실을 고려할 때 원발성 폐암의 치유 가능한 병기를 반영하는 고립성 폐결절이 발견된 환자에서 외과적 절제술을 포함한 보다 적극적인 진단적 접근이 필요할 것으로 보인다.

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

허혈성 심장 질환의 One-stop Evaluation Protocol: Myocardial Fusion PET Study (One-stop Evaluation Protocol of Ischemic Heart Disease: Myocardial Fusion PET Study)

  • 김경목;이병욱;이동욱;김정수;장영도;방찬석;백종훈;이인수
    • 핵의학기술
    • /
    • 제14권2호
    • /
    • pp.33-37
    • /
    • 2010
  • 관상동맥질환의 진단 및 평가에 있어서 myocardial perfusion SPECT검사와 FDG를 이용한 myocardial PET검사 그리고 PET/CT에 장착된 64-slice CT를 이용한 coronary CT angiography를 동시에 실행함으로 검사의 신뢰도와 편의성을 한층 더 높이고자 한다. 먼저 약물부하 myocardial perfusion SPECT검사를 먼저 시행한다. 환자의 피폭경감을 위해서 $^{99m}Tc$-MIBI 10 mCi 로 주사하며 myocardial PET검사를 위해서 지방식을 먹지 않고 ursodeoxcholic acid 100 mg을 생수와 함께 복용하게 하여 1시간 후에 SPECT 영상을 얻는다. 이어서 myocardial FDG PET검사를 시행한다. 혈중의 지방산 농도를 낮추고 심장의 FDG섭취율을 증가시키기 위해 혈중 포도당 농도치에 따라 insulin과 Acipimox를 함께 사용하는 독창적인 경구 당 부하법을 사용하였으며, 환자의 피폭 경감을 위해서 $^{18}F$-FDG 5 mCi를 주사하고 1시간 후에 10분간 gated 영상을 얻으며 필요시 delay 영상을 얻는다. PET검사가 끝남과 동시에 환자는 동일한 position을 하고 연속해서 coronary CTA를 시행한다. 이 검사에서 가장 중요한 것은 심박동수 조절과 환자의 호흡협조이다. 심박동수를 65회 이하로 낮추기 위해 beta blocker 50 mg~200 mg을 의사와 상의하여 복용케 하고 호흡법을 충분히 연습을 시키다. 검사 직전에 isosorbide dinitrate를 3~5회 분무하여 혈관벽의 긴장을 낮추고 혈관을 확장시켜서 coronary artery의 해부학적 형태를 더욱 잘 나타낼 수 있게 한다. 촬영 시 CT 조영제를 4.0~5.0 mL/sec의 압력으로 주입하며 촬영을 한다. Coronary CTA를 이용하면 coronary artery stenosis가 잘 보이며, 약물부하 myocardial perfusion SPECT로 coronary CTA에서 보인 stenosis와 perfusion저하의 상관관계를 검토(culprit vessel 확인)할 수 있으며, FDG PET으로 hibernating myocardium 또는 infarction site의 viability를 확인할 수 있다. 한 가지 검사로 lesion site와 severity 및 치료에 대한 반응 예측이 가능함으로 약물치료, PCI, CABG 등 치료방향을 설정할 수 있다. 또한 모든 검사 과정들이 연속적으로 동시에 이루어지기 때문에 짧은 시간(3시간) 내에 one-stop으로 검사를 종료할 수 있는 큰 장점을 가지게 된다. 그러므로 이 검사법은 ischemic heart disease의 one-stop evaluation에 있어서 유용한 protocol로 보여진다.

  • PDF

일차성 야뇨증 아동에서 야간 수분 제한의 치료 효과 (Therapeutic Effect of Nocturnal Water Restriction in Children with Primary Nocturnal Enuresis)

  • 이수진;양재영;김혜순;이승주
    • Childhood Kidney Diseases
    • /
    • 제5권1호
    • /
    • pp.51-58
    • /
    • 2001
  • 목 적 : 일차성 야뇨증의 치료는 민간 요법과 다양한 병인론에 근거한 각종 치료 방법이 개발 되어 있으나 가장 기본 치료인 야간 수분 제한의 치료 효과는 간과되어 왔다. 이에 저자들은 야뇨증의 일차적인 치료의 철저한 야간 수분 제한 효과만을 평가하고 성공 요인을 분석해 보고자 하였다. 대상 및 방법 : 1998년 10월부터 1999년 6월까지 이대목동병원 소아과 외래를 방문한 일차성 야뇨증 아동(주 3회 이상의 아뇨)중 2개월간의 야간 수분 제한에 순응도가 높은 41명(7.9${\pm}$2.3세)을 대상으로 하였다. 야간 수분 제한 전과 2개월 치료 후 매 2주마다 24시간 수분 섭취량과 요량을 (매주 1일이상) 기록하도록 하여 순응도를 평가하였다. 치료후 야뇨 횟수가 90$\%$이상 감소된 완전반응군, 50$\%$이상 9$\%$미만 감소된 부분반응군, 50$\%$이하로 감소된 무반응군으로 구분하여 치료율을 조사하였고, 치료에 대한 성공 요인으로 성별, 연령, 주간 배뇨 이상, 수분 섭취량, 요량, 최대 요량, 요농축능 등을 분석하였다. 치료 2개월 후 야간 요량, 최대 요량, 농축요삼투질 농도의 변화를 비교하였다. 결 과 : 야간 수분 제한 2개월 후의 반응률은 39.0$\%$ (l6/41)에서 완전반응, 43.9$\%$ (18/41)에서 부분반응, 17.1$\%$(7/41)에서 무반응을 보여 전체적으로 82.9$\%$ (34/41)에서 호전되었다. 야간 수분 제한의 치료 효과에 대한 예견 요인은 주간 배뇨 이상, 야간 수분 섭취량, 야간 요량, 방광 요인 등으로, 단증상 야뇨증 아동에서는 완전반응 50$\%$(13/26), 부분반응 46.2$\%$ (12/26)로 다증상 야뇨증 아동의 20$\%$ (3/15), 40$\%$ (6/15)에 비하여 유의하게 치료율이 높았다(P<0.05). 야간 수분 섭취량은 완전반응군 385${\pm}$109mL, 부분반응군 335${\pm}$105mL, 무반응군 233${\pm}$45 mL, 야간 다음은 각각 48.5$\%$(16/33), 42.4$\%$(14/33), 9.1$\%$(3/33)로 야간 수분 섭취량이 많을수록 유의하게 치료율이 높았다 (P<0.05). 야간 요량은 완전반응군 390${\pm}$62mL, 부분반응군 330${\pm}$136mL, 무반응군 140${\pm}$43mL, 야간 다뇨는 각각 59.3$\%$(16/27), 40.7$\%$(11/27), 0$\%$(0/27)로 야간 요량이 많을수록 유의하게 치료 효과가 좋았다(P<0.05). 일회 최대 요량은 완전반응군 236${\pm}$42 mL, 부분반응군 209${\pm}$56 mL, 무반응군 107${\pm}$36mL로 최대 요량이 많을수록 유의하게 치료 효과가 좋았다 (p<0.05). 연령, 성별, 일일 수분 섭취량, 다음, 일일 요량과 다뇨은 세 군간에 유의한 차이가 없었다. 야간 수분 섭취 제한 후 야간 요량의 감소 정도는 완전반응군 173${\pm}$56mL, 부분반응군 135${\pm}$83mL로 무반응군 28${\pm}$15mL에 비하여 유의하게 컸다 (P<0.05). 최대 요량의 증가도 완전반응군 88${\pm}$27mL, 부분반응군 79${\pm}$38mL로 무반응군 17${\pm}$13mL에 비하여 유의하게 컸다 (p<0.05). 농축요삼투질 농도의 증가 역시 완전반응군 190${\pm}$42mO느/kg, 부분반응군 254${\pm}$115mOsm/kg으로 무반응군 25${\pm}$32 mOsm/kg에 비하여 유의하게 컸다(p<0.05). 결 론 : 일차성 야뇨증은 야간 수분 섭취 제한만으로도 치료율이 높았고, 주간 배뇨 이상이 없고, 야간 다음, 야간 다뇨, 및 최대 방광용적이 높은 아동에서 치료 효과가 좋았다.

  • PDF

심혈관계 질환 환아에서 동반된 기도 압박 및 기도 기형의 임상적 특성 (Airway Compression or Airway Anomaly Causing Respiratory Symptoms in Infants and Children with Cardiovascular Diseases)

  • 김자형;이소연;김효빈;구소은;박성종;김영휘;박인숙;고재곤;서동만;홍수종
    • Clinical and Experimental Pediatrics
    • /
    • 제48권7호
    • /
    • pp.737-744
    • /
    • 2005
  • 목 적 : 심혈관계 질환을 가진 영아 및 소아는 흔히 호흡기 증상을 동반하는데 그 원인은 외부적인 기도 압박에서부터 기도 자체의 기형에 이르기까지 다양하다. 그러나, 수술 전후로 원인에 대한 정확한 평가가 시행되지 않아 진단이 늦어지거나 사망률을 증가시키는 요인이 되기도 한다. 이에 저자들은 심혈관계 질환 환아 중에서 기도 압박 및 기도 기형이 확진되었던 환아들을 대상으로 그 임상적인 특징을 분석함으로써 조기에 기도 이상을 발견하고 자연 경과 및 수술 후 예후에 도움이 되고자 본 연구를 시행하였다. 방 법 : 1997년 1월부터 2004년 6월까지 서울아산병원 소아과에서 심혈관계 질환으로 진단 받은 환아 중 수술 전후 기도 압박이나 기도 기형이 확진된 64명(평균 연령; $6.3{\pm}7.5$개월, 남녀 각각 33명, 31명)을 대상으로 심혈관계 질환의 종류, 호흡기 증상의 진단 시기 및 종류, 흉부 전산화 단층촬영, 굴곡성 기관지경 검사 소견, 동반 기형 유무, 기계적 환기 유지 기간, 수술 후 경과 관찰 등을 후향적 방법으로 분석하였다. 대상 환아는 기계적 환기(mechanical ventilation)가 필요했던 기간을 기준으로 1군(${\leq}7$ days)과 2군(>7 days)으로 분류하여 비교 검토하였다. 결 과 : 환기 기간이 7일 이상 필요했던 2군의 환아들의 경우 1군보다 수술 후에 호흡기 증상이 더 많이 발견되었고(P<0.001), 통계학적으로 유의한 차이는 없었으나 외부 압박과 기도 자체의 기형, 혹은 두 가지 모두 동반된 경우도 더 많이 관찰되었다. 기저 심혈관계 질환의 종류는 1군의 경우 혈관 기형과 대동맥궁 압박이 각각 6명(26.2%), 2군은 심실중격결손이 있는 폐동맥 폐쇄증이 9명(22.4%)으로 가장 많았고 이중 2명은 대동맥-폐동맥간 측부 동맥을 동반하였다. 외부 구조물에 의한 기도 압박은 심실중격결손이 있는 폐동맥 폐쇄증과 대동맥궁 압박에서 흔히 관찰되었고, 가장 흔한 기도 압박 부위는 좌측 주기관지로 주로 대동맥과 폐동맥 사이에서 압박된 경우가 24명으로 가장 많았다(63.2%). 기도 기형은 기관연화증과 기관 협착이 각각 4명(18.2%)으로 가장 많았고, 이외에도 다양한 기도 기형들이 관찰되었다. 지속적인 호흡기 증상에 대한 수술적 교정을 시행한 환아는 총 19명으로 이중 대동맥 고정술을 시행한 6명(6/11; 54.5%)과 혈관 기형으로 교정술을 시행한 7명(7/8; 87.5%)이 경과가 양호하였다. 그러나 2명은 교정술 후에도 기계적 환기 이탈에 실패하였고, 4명은 감염이나 폐고혈압으로 사망하였다. 결 론 : 심혈관계 질환을 가진 영아 및 소아에서는 호흡기 합병증을 병발할 수 있는 고위험군 환자, 특히 6개월 미만의 영아나 심실중격결손이 있는 폐동맥 폐쇄증이나 대동맥 기형이 기저질환인 경우 기도 압박이 동반될 수 있으므로 조기에 삼차원 재구성 흉부 전산화 단층촬영이나 굴곡성 기관지내시경과 같은 적극적인 검사로 기도 이상에 대한 진단을 미리 시행하고 이를 바탕으로 계획된 치료를 하는 것이 기저 심장질환의 자연 경과뿐만 아니라 수술 후 예후를 호전시킬 수 있을 것으로 생각한다.

구강악안면 수술을 받은 환자들에서의 전신영양평가 (EVALUATION OF SERUM LEVELS OF SYSTEMIC STATUS IN ORAL AND MAXILLOFACIAL SURGERY PATIENTS)

  • 김욱규;김용덕;변준호;신상훈;정인교
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제29권5호
    • /
    • pp.301-314
    • /
    • 2003
  • 본연구는 1998년 9월부터 2001년 9월까지 부산대학교 병원 구강악안면외과에 입원하여 구강암수술을 받았던 환자들중 무작위로 10명을 추출하여 실험1군으로, 심한 악안면감염증으로 인한 농양으로 절개 및 배농을 시행받았던 환자중 무작위로 10명을 추출하여 실험2군으로, 다발성 악안면골 골절상을 수상하여 골정복술을 시행받은 환자중 무작위로 10명을 추출하여 실험3군으로 선정하였다. 후향적 조사연구로서 이학적 임상평가자료 및 혈중의 여러 임상병리지표들을 비교하여 각군에서의 수술전, 수술직후, 수술후 1주째 또는 추가적으로 수술후 3주째 혈액검사상의 수치들에 대해 평균과 표준편차를 추출하였고 시기에 따른 유의성 있는 변화량을 나타내는 수치를 통계적으로 검정하였다. 또한 임상생징후 소견과와 관련하여 검사수치와의 연관성을 살펴보았다. 또 각 수치들 간의 상관관계가 유의성있게 나타난 경우를 통계적으로 검정하였다. 최종적으로 병리학적 수치변화로서 환자의 임상예후를 짐작할수 있는 유용한 혈액학적 지표를 확정하고자 하였다. 이상의 연구결과 다음의 결과를 얻었다. 1. 종양환자에서는 Hb, MCV, Albumin, Cholesterol, LDH, AST, ALT, Neutrophil, Platelet, Leukocyte, Na, K, Cl, BUN, Creatinine으로 환자의 전신영양평가를 조사 하였다. 이 중 Hb, Albumin, AST, Neutrophil, Leukocyte, Cl 만이 시기별에 따라 유의성있는 변화치를 나타내었다. 그중 시기별 평균치가 정상범주와 큰 차를 보인 항목은 Cl 이었고 술전, 술후 1주째 유의 수준차는 P=0.004로 나타났다.임상 생징후인 체온, 호흡수, 혈압모두에서 혈액학적 수치과 관련된 유의성 있는 변화가 관찰되지 않았다. 2. 농양환자에서는 CRP, ESR, Leukocyte, Body temperature, Neutrophil로서 감염정도에 따른 변화를 조사하였다. 이중 ESR 수치를 제외한 CRP, Leukocyte, BT, Neutrphil은 시기별에 따라 모두 유의성있는 변화치를 나타내었다. 시기별 평균치가 정상범주와 큰 차를 보인 항목은 CRP로서 술전, 술후 1주째 유의 수준차는 P=0.001로 나타났다. 기대되 었던 체온변화와 다른 혈액지표와 관계는 유의성을 띠지 못하였다. 3. 골절환자에서는 Hb, MCV, Albumin, Cholesterol, LDH, AST, ALT, Neutrophil, Platelet, Leukocyte, Na, K, Cl, BUN, Creatinine으로서 종양환자에서의 항목과 동일하게 하였다. 골절치료전, 치료후 퇴원시의 변화를 통계처리한 결과 Na와 Platelet 수치를 제외하고는 유의성있는 변화치는 관찰되지 않았다. 시기별 평균치가 정상범주와 큰 차를 보인 항목은 Platelet로서 술전과 술후의 유의수준차는 P=0.009로 나타났다. 임상생징후 변화는 유의성이 없었다. 4. 종양환자의 검사치간의 시기별에 따른 상관관계를 조사한 결과 유의확률이 0.05 이하인 수치들은 Hb과 Albumin, K, Na간, Neutrophil과 Leukocyte간이었고 상관계 수치는 $0.370{\sim}0.442$ 사이로 나타났다. 유의확률 0.01이하로 조사된 수치는 Cholesterol과 ALT간, LDH와 Platelet, Creatinine간, Platelet와 BUN간, Na와 K수치간 이었으며 상관계수는 $0.531{\sim}0.866$사이로 나타났다. 5. 농양환자에서의 검사치간 상관관계를 조사한 결과 유의확률이 0.05이하인 수치들은 CRP와 Neutrophil간 이었고 상관계수는 0.422이었고 유의확률은 0.020으로 나타났다. 6. 골절환자에서의 검사치간 상관관계를 조사한 결과 유의확률 0.05이하인 수치들은 MCV와 K 간, Albumin과 LDH 간, AST와 Creatinine, Na, Cl간, K와 Neutrophil간, Neutrophil과 Leukocyte, BUN, K간에서 유의성을 나타내었고 $0.421{\sim}0.511$ 사이의 상관 계수치의 분포를 보였다. 유의확률 0.01이하로 유의수준이 부여된 수치들은 LDH와 AST간, ALT와 AST, Creatinine간이었고 $0.528{\sim}0.535$의 상관 계수치를 보였다. 7. 농양환자에서 CRP의 변화량이 감염양상에 따라 유의한 변화를 보인것외 통상의 병리학적 혈액수치만으로 구강악안면 외과환자의 전신상태를 판정할수 있는 특징적인 양상을 띤 혈액학적 지표는 도출되지 않았다.

RDC/TMD Axis I 진단에 따른 측두하악장애 환자의 측두 두부방사선적 특징에 관한 연구 (Cephalometric Characteristics of TMD Patients based on RDC/TMD Axis I Diagnosis)

  • 안지연;김용우;김영구;이정윤
    • Journal of Oral Medicine and Pain
    • /
    • 제36권1호
    • /
    • pp.39-51
    • /
    • 2011
  • 본 연구는 측두하악장애의 연구 진단 기준(Research Diagnostic Criteria for Temporomandibular Disorder; RDC/TMD)을 이용하여 구분된 측두하악장애(Temporomandibular Disorder; TMD) 환자를 대상으로 안면의 골격적 양상과 TMD 사이의 연관성을 규명하고 교정 환자의 진단과 치료에 있어 RDC/TMD의 활용 가능성을 제시하고자 하였다. 서울대학교 치과병원 구강내과에 측두하악장애의 진단과 치료를 위해 내원한 여성 환자들의 의무 기록 및 방사선사진을 검토하였으며 환자의 연령이 18세 미만이거나 전신 질환, 골격적 기형 또는 측두하악관절 부위의 외상 병력이 있는 경우는 제외되었다. 총 96명의 여성 환자로부터 얻은 RDC/TMD Axis I 을 포함한 임상 검사 결과와 측방 두부규격방사선사진 (lateral cephalogram), 파노라마 방사선사진(panoramic radiograph) 및 횡두개 방사선사진(transcranial radiograph)을 이용한 방사선적 검사 결과를 분석하였다. RDC/TMD를 이용하여 집단을 분류한 후 측방 두부규격방사선사진의 각도 및 길이 요소들을 계측하여 안면의 골격 관계, 상하악 관계 및 치열 관계를 분석하였다. 통계적 분석법으로는 독립표본 t-검정(independent t-test), 일원분산분석(one-way Analysis of Variance; one-way ANOVA) 및 카이제곱 검정(chi-square test)을 이용하였고 다음과 같은 결과를 얻었다. 1. 근육 문제를 진단하는 RDC/TMD Axis I 의 제 1 군 측두 두부방사선적 특징에서 통계적 유의성이 인정되지 않았다. 2. 관절원판 변위를 임상적으로 진단하는 제 2 군에서는 개구 장애를 동반하지 않는 비정복성 관절원판 변위가 있는 경우 관절원판 변위가 없는 정상 집단에 비하여 articular angle이 큰 것으로 나타났다. 3. 관절통, 관절염 및 관절증을 진단하는 제 3 군에서는 articular angle, FMA, Bjork sum, posterior facial height 및 facial height ratio에서 유의한 차이가 있는 것으로 분석되었다. 4. TMD 진단군과 골격적 양상 사이의 관계를 단순화하기 위하여 RDC/TMD Axis I 각 군을 양분법적으로 분류한 뒤 동일 한 방식으로 분석을 시행하였다. 그 결과 제 1 군에서는 overjet, 제 2 군에서는 articular angle, facial height ratio 및 IMPA, 마지막으로 제 3 군에서는 articular angle, gonial angle, facial convexity, FMA, Bjork sum, posterior facial height, facial height ratio 및 ANB angle에서 유의한 차이를 보였다. 이상의 RDC/TMD Axis I 을 이용하여 진단된 측두하악장애 환자를 대상으로 안면의 골격적 양상과 TMD 사이의 연관성 을 분석한 결과로부터 RDC/TMD Axis I 임상 진단에 따라 진단한 측두하악장애 환자 중 제 2 군과 제 3 군의 환자들에서 측두하악장애와 관련된 것으로 알려진 하악골의 후하방 회전으로 인한 골격적 차이가 존재함을 확인하였다. RDC/TMD Axis I은 교정 전 혹은 교정 치료 진행 중에 임상 검사 및 일반 방사선사진으로부터의 제한된 정보를 바탕으로 교정 치료 중 고려하여야 할 TMD 환자를 감별하는데 유용한 정보를 제공할 수 있을 것이다.

초기 유방암의 유방 보존수술 후 방사선 치료 결과 (Clinical Outcome after Breast Conserving Surgery and Radiation Therapy for Early Breast Cancer)

  • 조흥래;김철진;박성광;오민경;이진용;안기정
    • Radiation Oncology Journal
    • /
    • 제26권4호
    • /
    • pp.204-212
    • /
    • 2008
  • 목 적: 유방 보존수술 후 방사선 치료를 받은 환자에서 치료의 성적과 무병 생존율 및 재발에 영향을 주는 위험인자에 대해 알아보고자 하였다. 대상 및 방법: 1997년 3월부터 2003년 12월 까지 유방 보존수술 시행 후 방사선 치료를 받은 환자 77명을 대상으로 후향적으로 분석하였다. 추적 관찰 기간의 중앙값은 58.4개월($43.8{\sim}129.4$개월)이었다. 전체 환자의 평균 연령은 41세, 중앙 연령은 40세이었다. 수술 후 조직학적 T 병기는 Tis가 7명, T1 38명(49.3%), T2 28명(36.3%), T3 3명, 미확인이 1명이었다. 액와 림프절 전이가 없는 경우가 52명(67.5%), $1{\sim}3$개 전이가 14명(18.1%), 4개 이상이 3명(0.03%)이었다. 절제연이 음성인 환자는 59명이었고, 2 mm 이내로 근접한 경우는 15명, 양성인 경우는 2명이었다. 방사선치료는 전체 유방에 접사면으로 조사한 후 원발 병소 부위에 전자선으로 추가조사 하여 총 59.4 Gy에서 66.4 Gy를 시행하였다. 액와 림프절의 개수가 4개 이상인 경우에는 액와 림프절과 쇄골 상 림프절을 포함하여 $41.4{\sim}60.4$ Gy를 조사하였다. 항암화학요법은 59명에서 시행되었고, 호르몬 치료로는 tamoxifen 또는 fareston을 사용하였으며 29명에서 시행하였다. 결 과: 5년 생존율은 98.1%이었으며, 5년 무병 생존율은 93.5%이었다. 총 77명의 환자 중 4명(5.2%)의 환자가 재발을 하였다. 1명은 쇄골 상 림프절 재발, 1명은 쇄골 상 림프절과 동시에 다발성 원격전이, 다른 2명은 원격전이가 발견되었다. 원발 병소 주위의 국소 재발은 추적 관찰 기간 중 발견되지 않았다. 림프절 전이 유무나 숫자는 재발이나(p=0.195)무병 생존율(p=0.30)에 영향을 미치지 않았다. 절제연이 양성인 2명 중 1명이 7개월 만에 재발을 하였고, 재발 기간까지 걸린 기간인 무병 생존기간이 통계적으로 의미 있게 짧은 것으로 나타났으며(p<0.0001), 재발 빈도도 절제연이 음성이거나 가까운 경우에 비해서 통계적으로 의미가 있는 것으로 나타났다(p=0.0507). 그러나 절제연이 근접한 경우에는 절제연 음성인 경우와 비교하여 통계적으로 재발 빈도에 차이가 없었다(p=1.000). 재발된 4명은 모두 40세 이하로 9.2%의 재발률을 보인 반면, 40세 이상에서는 재발이 없었으나 두 그룹 간에 통계적으로 유의한 차이는 없었다(p=0.1255). 수술 후 조직학적 T 병기는 T2의 경우 4명(14%)이 재발한 반면, T1에서는 재발이 발견되지 않았으며 통계적으로 유의한 차이를 보였다(p=0.0284). 무병 생존율도 T2 환자의 경우에 통계적으로 의미 있게 낮은 것으로 나타났다(p=0.0379). 무병 생존율에 영향을 미치는 단변량 분석에서 수술 후 조직학적 T 병기, 절제연의 상태, p53 수용체 변이가 통계적으로 의미 있게 나왔다. 결 론: 초기 유방암에서 유방 보존수술 후 방사선치료는 높은 국소제어율과 무병 생존율을 보이는 안전한 치료이다. 절제연 양성, 수술 후 조직학적 T병기, p53 수용체 변이 등은 통계적으로 유의하게 재발 위험이 높은 군에 속하였으며, 무병 생존율에 영향을 미치는 것으로 밝혀졌다.