• Title/Summary/Keyword: horn

Search Result 923, Processing Time 0.026 seconds

An Influence on the City Noise of Colonial Joseon by the Motor Vehicle Horn (자동차 경음 기술이 식민지 조선의 도시소음에 미친 영향)

  • Shin, Myung-Ho;Sohn, Jeong-Hyun;Chae, Young-Hee
    • Journal of Power System Engineering
    • /
    • v.17 no.3
    • /
    • pp.111-122
    • /
    • 2013
  • After the port opening in 1876, the western people made joseon image as the land of morning calm. there was a conception that joseon was a uncultivated country in the meaning of the land of morning calm. famous modernists such as gil-jun yu, kwang-su lee also had same conception. but such conception began to change in 1930's. the number of motor vehicle began to increase rapidly in 1930's. and also many of motor vehicle were equipped with air horn or electronic horn instead of bulb horn. bulb horn made thick and low rubber sound. but air horn or electronic horn made sharp and high metallic sound. city people of colonial joseon began to recognize air horn or electronic horn as city noise. so they tried to control the use of air horn or electronic horn. finally, in late 1930's, the use of air horn and electronic horn were prohibited.

Design of Ultrasonic Vibration Tool Horn for Micromachining Using FEM (유한요소법을 이용한 초음파 진동 공구혼 설계에 관한 연구)

  • Lee, Bong-Gu;Kim, Kwang-Lae;Kim, Kang-Eun
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.17 no.6
    • /
    • pp.63-70
    • /
    • 2008
  • Conical horn is used in many high frequency ultrasonic horns, to achieve a longitudinal vibration mode across a wide ultrasonic tool horn output surface. Modal analysis is method for designing tuned ultrasonic tool horn and for the prediction natural frequency of ultrasonic tool horn vibration mode. The design of ultrasonic horn is based on prototype estimate obtained by FEM analysis. The FEM simulated ultrasonic tool horn is built and characterized experimentally through laser vibrometer and electrical impedance analysis. In this paper, FEM analysis is developed to predict the natural frequency of ultrasonic tool horn and use of in the optimal design of ultrasonic horn shape.

Study on the Development of High Quality Horn Sound based on Psychoacoustics (심리 음향을 기반으로 한 고급 Dual Shell Horn 개발)

  • Jeong, Ki Woong;Park, Dong Chul;Lee, Sang Kwon;Kang, Hee Su;Oh, Youn Suk
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2013.10a
    • /
    • pp.513-518
    • /
    • 2013
  • The purpose of vehicle horn sound is for warning to pedestrians. In the past, the main development factor is to match the regulation level. But nowadays perceived quality is more important than level itself. In this study, we measure variety horn sound and evaluate its signals through the jury evaluation aimed at making horn sound quality index. Each contribution of the noise path for sound quality is identified and the target values and methods for implementing the luxurious horn sound are suggested. Finally, we developed, horn component and improve horn mounting condition for luxurious horn sound.

  • PDF

Design of Dual Mode Conical Horn Antennas (복 모드 원추 혼 안테나의 설계)

  • 최학근;박종호;박정희
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.25 no.12
    • /
    • pp.1573-1581
    • /
    • 1988
  • In this paper, the analysis on the dual mode conical horn antennas is made to realize the optimum horn as the primary feed of the offset parabolic antenna for the domestic broadcasting satellite. Such analysis can give rise to the approximate equations and graphs on the beam width, which makes it possible to design the desired conical horn. It has been shown that the radiation charateristics of designed horn antenna built with the dielectric band inside the horn. The designed dual mode horn antenna may provide the useful basis to practical usage of the antenna in the domestic satellite broadcasting communication systems.

  • PDF

Design Improvement and Performance Evaluation of 20kHz Horn for Ultrasonic Cutting (20kHz 초음파 커팅용 혼의 설계 개선과 성능평가)

  • Seo, Jeong Seok;Lee, Yoon Jeong;Kim, Jin Wook;Park, Dong Sam
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.12 no.5
    • /
    • pp.135-140
    • /
    • 2013
  • Ultrasonic cutting is a kind of eco-technique and cost-effective technique to be used for cutting of various materials such as baked product, fresh/frozen food, rubber, textile, wood, bone, etc. The performance of ultrasonic cutting is affected by design of cutting horn and cutting conditions. Specially the design of horn to resonate at the longitudinal direction is most important. To analyze the problems from which cracking and noise are often generated with conventional cutting horn, FEA is carried out, and then improved cutting horn which can reduce maximum stress and stress concentration is designed. Vibration characteristics, resonant frequency, gain, and amplitude uniformity of the cutting horn designed optimally are evaluated through FFT analysis and compared with those of conventional cutting horn.

Design of Cylinder Horn for Ultrasonic Welding (초음파 용접용 실린더 혼의 설계)

  • Kim, Sun-Rak;Lee, Jae-Hak;Yoo, Choong-D.
    • Journal of Welding and Joining
    • /
    • v.27 no.4
    • /
    • pp.60-66
    • /
    • 2009
  • The cylinder horn is designed to increase uniformity of the displacement on the output face through simulation and experiments for the simple cylinder, spool and step horns. The modal analysis is conducted numerically to calculate the vibration mode and stress distribution of the cylinder horn, and the design of experiment (DOE) technique is employed to determine the optimum configuration of the spool horn. Displacement of the cylinder horn was measured using the Laser Doppler Vibrometer (LDV), and experimental results show good agreements with the predicted results. It appears that uniformity higher than 95% can be achieved with the spool horn when the proper dimension of the groove is used.

Giant Cutaneous Horn Associated with Squamous Cell Carcinoma: A Case Report (편평상피암과 연관된 거대피각 1례)

  • Lee, Jung Hoon
    • Archives of Plastic Surgery
    • /
    • v.32 no.5
    • /
    • pp.645-648
    • /
    • 2005
  • Cutaneous horn is a morphologic designation for a projectile, conical, dense hyperkeratotic nodule that resembles the horn of an animal. The lesion varies in size from only a few millimeters to several centimeters, in color(white or yellowish) and in form (straight, curved, or twisted). It arises from a wide range of epidermal lesions, which include benign lesions, premalignant lesions and malignant lesions. An 83-year-old women came to our clinic with a giant cutaneous horn on the right chin and a small horn on the left upper eyelid. The patient had no palpable cervical lymph node. A wide elliptical skin incision was made and the horn was totally excised. In pathology, the giant cutaneous horn on the right chin revealed a moderately differentiated squamous cell carcinoma with subcutis invasion at its base. "Giant cutaneous horns" have often been associated with invasive squamous cell carcinoma. Cutaneous horns are common lesions usually found on the face, rarely larger than 2 cm. As large cutaneous horns are often associated with underlying malignancy, histopathologic examination of the base of the lesion is necessary to rule out carcinoma and full excision is recommended.

A Study on the Acoustic Modeling of Horn - Analysis and Design of Acoustic Horn - (Horn의 음향 모델링 연구 - 음향 혼의 해석 및 설계 -)

  • Sa, Jong Sung;Park, Seok-Tae
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.7
    • /
    • pp.537-548
    • /
    • 2014
  • In this paper, horn loudspeaker modeling was suggested, investigated and verified through comparison of test results and simulation ones based on input electrical impedance curves and acoustic sensitivity ones. First, Thiele Small parameters of horn driver were identified by using pseudo loudspeaker model concept and verified in case of both closed and open horndriver. Second, cone-shaped horn models were investigated and compared with input acoustic impedance curves for real horn(cone angle $6.6^{\circ}$) and short horn(cone angle $27.9^{\circ}$). It showed that Leach model for cone horn was well described to test results, which were electrical impedance and acoustic sensitivity, compared to Lemaitre one. To represent horn system model good approximation in wide frequency range, mass correction filter and lowpass filter were adopted and consequently showed good fitted to test results.

An Efficient Execution of Non-Horn Logic Programs (비혼 논리 프로그램의 효율적 수행)

  • Shin, Dong-Ha;Baek, Ynn-Cheol
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.9 no.4
    • /
    • pp.816-823
    • /
    • 2005
  • Non-Horn logic programs are extended from Horn logic programs to the level of 1st order predicate logic. Even though they are more expressive than Horn logic programs, They are not practically used because we do not have efficient implementations. Currently to execute non-Horn logic programs, we translate them to equivalent Horn logic programs using the proof procedure InH-Prolog and compile the Horn logic programs to WAM(Warren Abstract Machine) instructions. In this paper, we propose EWAM(Extended Warren Machine) that executes non-Horn logic programs more efficiently and a compilation scheme that compiles non-Horn logic programs to the EWAM instruction. We implement an EWAM emulator and a compiler and measured the performance of the EWAM emulator and the compiler and found that they are very efficient.

Differential Actions of Intracerebroventricular Opioid Receptor Agonists on the Activity of Dorsal Horn Neurons in the Cat Spinal Cord (Opioid 수용체 효능제의 뇌실 내 주입이 고양이 척수후각세포의 활성에 미치는 영향)

  • 문태상;오우택
    • YAKHAK HOEJI
    • /
    • v.43 no.4
    • /
    • pp.411-418
    • /
    • 1999
  • Intracerebroventricular (ICV) infusion of morphine (MOR) produces strong analgesia in man and animals. The analgesic effect is thought to be mediated by the centrifugal inhibitory control. But neural mechanisms of the analgesic effect of ICV morphine are not well understood. In the present study, we found that ICV MOR had dual actions on the activity of dorsal horn heurons: it produced both inhibition and excitation of dorsal horn neurons. Since MOR exerts its action via three different types of opioid receptors, we further sought to investigate if there are differential effects of opioid receptor agonists on dorsal horn neurons when administered intracerebroventricularly. Effects of ICV MOR were tested in 28 dorsal horn neurons of the spinal cord in the cat. ICV MOR inhibited, excited and did not affect the heat responses of dorsal horn neurons. ICV DAMGO and DADLE, $\mu$- and $\delta$-opioid agonist, respectively, exhibited the excitation of dorsal horn neurons. In contract, U-50488, a k-opioid agonist, exhibited both the inhibition and excitation of dorsal horn neurons. These results suggest that opioid receptors have different actions on activity of dorsal horn neuron and that the inhibitory action of k-opioid agonist may subserve the analgesia often produced by ICV MOR.

  • PDF