• 제목/요약/키워드: horizontal arm

검색결과 105건 처리시간 0.025초

배구 레프트 스파이크와 라이트 스파이크 동작에 대한 운동역학적 변인 비교 분석 (Analysis of Sports Biomechanical Variable on the Motions of Left and Right Spikes of Volleyball)

  • 조주행;주명덕
    • 한국운동역학회지
    • /
    • 제16권4호
    • /
    • pp.125-134
    • /
    • 2006
  • The purpose of this study was to analyze the Biomechanical elements by looking at the differences on the motions of the right and left spikes of right-handed offense volleyball players, using 3D image analysis and force platform. For that purpose, spike motions of six male university volleyball players were recorded three times each using two 16mm high speed cameras and the speed of recording was set at 60 frames/sec. The coordinated raw data was leveled as 6Hz using low pass filtering method and the calculation of 3D coordinates was done by using a DLT (Direct Linear Transformation) method. Also KWON 3D program was used to analyze the variables. Through the experiments and research, the following results were found: That is, in case of the right spike, the required time from the toss to the impact, which affected the success rate of offense showed as longer and on the take-off, the exact timing to touch the ball was longer because the pace between right and left feet was wider, and also after the jump, the distance between the feet indicated shorter, than the left. In addition, the degree of somersault and horizontal adduction of shoulder joint was smaller and the degree of medial rotation of shoulder joint showed bigger than the left, so it indicated that it was not centered on the body, but by the arm with an axis of shoulder using a swing motion. After the impact, the speed of the ball indicated slower compared to the left spike.

인체측정(人體測定) 방법(方法)에 관(關)한 비교(比較) 연구(硏究) - 인체측정(人體測定) 기준점(基準點), 기준선(基準線)을 중심(中心)으로 - (A Comparative Study on the Anthropometric Method - Anthropometric Point and Line -)

  • 권영자;심부자
    • 패션비즈니스
    • /
    • 제5권4호
    • /
    • pp.89-100
    • /
    • 2001
  • The major purpose of this study is to show exact and convenient devices and minimize error in body measurement. This study was referred to 13 records and compared 6 items that the investigator's opinion has been differed about anthropometric point and line and suggested convenient and radical device, and measured by if need be. The 30 students from 20 to 25 ages were measured and data was analyzed by mean, std. deviation and paired t-test. The results are as follows. 1. Side neck point has been suggested many devices, but was suggested in this study to decide by M. trapezius, cervicale point and fossa jugularis point. 2. Shoulder point was suggested to decide by point of 1/2 armhole depth, upper arm depth and shoulder depth except acromion point. 3. Waist circumference line has been differed between horizontal line and natural line. The result of measurements was no significant difference between two methods and natural line was convenience. Waist circumference line must considered two methods together for garment construction and somato type. 4. The standard of hip circumference line has been differed between buttock point and trochanterion point. The result of measurements was significant difference between two methods, but two point must considered together because of body type. 5. Chest circumference line at scye has been differed between horizontal line and natural line. The result of measurements was significant difference between two methods and natural line was convenience. Chest circumference line at scye must studied to decide method the line for garment construction.

  • PDF

노년기 여성의 상지동작별 형태변화에 관한 연구 -석고법에 의한 피복인공공학적 접근- (A Study on the Sleeve Form Variation According to Arm Movements for Elderly Women - Approach to Clothing Ergonomics by Plaster Gypsum Experiments -)

  • 민현자;김혜경
    • 한국의류학회지
    • /
    • 제13권2호
    • /
    • pp.155-165
    • /
    • 1989
  • The purpose of this study was to investigate on the sleeve form variation according to arm movements for elderly women. This study was experimented using the Plaster gypsum. The subjects who were elderly women were divided into three groups according to Rorher Index. Arm movements were five type ($0^{\circ},\;45^{\circ},\;90^{\circ},\;135^{\circ},\;180^{\circ}$) to each the vertical motion in front and in side. The statistical analyses used in this study were Mean, Standard Deviation, Spearman's correlation coefficients, paired T-test, Kruskal-wallis one-way ANOVA and Duncan's multiple range test. The results were as follows: 1) Increasing the movements, the width of the sleeve increased and the height of the sleeve cap decreased but girth of the sleeve cap was not consistant. 2) When varied the rates of the three aspects of the sleeve, the height of the sleeve cap showed the largest variation rate. 3) There was a negative correlation between the height and the width of the sleeve. On the other hand, there was a positive correlation between the sleeve width and the sleeve girth. 4) There were the vertical motion differences between in front and in side on the three aspects of sleeve. 5) The sleeve width and the sleeve girth were different according to somatotypes but the height of the sleeve cap was not different. 6) According to the variation rates of the body surfaces in length of standard lines, the form of sleeve was changed more in the front than in the back. Maximum variation rate showed in the areas of $D_1-D_3,\;E_1-E_3$ in the horizontal lines and $A-E_2$ in vertical lines. 7) According to the comparative drawing of the heights of sleeve cap and sleeve girth, the sleeve basic pattern $S_1(A.H/4)$ was more suitable for the direction $0^{\circ}\;and\;45^{\circ}$. And the basic pattern S_6(A.H/5)$ was more suitable for the direction $90^{\circ}$, the pattern $S_7(A.H/6)$ suitable for the direction $135^{\circ}$, and the pattern $S_8(A.H/8)$ was more suitable for the direction $180^{\circ}$.

  • PDF

신체측정치수를 적용하여 다중회귀 분석을 통한 위팔두갈래근 등장성 운동의 근지구력시간 예측모델 연구 (Prediction Model of Endurance Time to Isotonic Contraction Exercise for Biceps Brachii using Multiple Regression Analysis with Personal Factors and Anthropometric Data)

  • 정주영;이상식
    • 한국정보전자통신기술학회논문지
    • /
    • 제8권2호
    • /
    • pp.178-186
    • /
    • 2015
  • 근지구력시간은 근피로를 평가하는 매우 중요한 지시자이다. 근지구력 시간을 직접 측정할 경우 근골격계 손상의 위험이 있다. 따라서 본 연구에서는 근지구력시간을 개인요소와 신체측정치수의 간접측정으로 예측할 수 있는 모델을 제시하려고 한다. 초기에는 개인요소인 성칭과 연령이 근지구력시간의 예측에 상관없다는 결과가 있었지만, 최근에는 팔의 중력토크(GTA, gravitational torque of the horizon arm, stretched arm)와 최대자율수축강도(MVC, maximum voluntary contraction) 등을 독립변수 또는 예측변수로 적용하여 근지구력시간을 예측하였다. 본 연구에서는 등장성 운동 시 개인요소와 신체측정치수를 이용하여 근지구력시간을 예측할 수 있는 변인들에 관하여 연구하였다. 총 25명의 피검자가 자원하여 10%,20%,30%,40% 그리고 50%MVC 강도의 등장성 운동을 수행하였다. 그 후 회귀분석을 통해 산출된 상관계수를 비교하였으며, 그 결과 다중회귀모델에서 유의성 있는 상관계수가 있었으며 근지구력시간을 예측하는 변인으로써 유용함을 알 수 있었다.

시분할 방식을 이용한 3차원 초음파 풍향풍속계 측정기술 개발 (Development of 3 - Dimensional Ultrasonic Wind Direction Anemometer Measurement Technique Using Time Division Method)

  • 이우진;최재영;김경원;임재홍
    • 센서학회지
    • /
    • 제26권1호
    • /
    • pp.66-72
    • /
    • 2017
  • The three dimensional ultrasonic anemometer was constructed to reduce the disadvantages of the two-dimensional anemometer and to be free from the use environment. Three pairs of transmitting and receiving ultrasonic sensors were designed to face each other at an angle of $45^{\circ}$ to the upper and lower surfaces at intervals of $120^{\circ}$. 200 kHz ultrasonic sensor Oscillation, transmission and reception, level detection, power supply circuit were designed and U, V, W wind speed vector components were obtained by measuring the time of first received ultrasonic pulse by transmitting pulse ultrasound. It is implemented as firmware in ARM Coretex-M3 processor so that horizontal and vertical wind direction and wind speed can be converted into digital signal by vector calculation. In this study, The three-dimensional ultrasonic anemometer can complement the disadvantages of the two-dimensional anemometer (mechanical and ultrasonic), and it is expected to gradually replace the two-dimensional anemometer due to its high utilization rate by collecting additional information such as vertical wind.

Analytical method for the out-of-plane buckling of the jib system with middle strut

  • Wang, T.F.;Lu, N.L.;Lan, P.
    • Steel and Composite Structures
    • /
    • 제21권5호
    • /
    • pp.963-980
    • /
    • 2016
  • The jib system with middle strut is widely used to achieve the large arm length in the large scale tower crane and the deployability in the mobile construction crane. In this paper, an analytical solution for the out-of-plane buckling of the jib system with middle strut is proposed. To obtain the analytical expression of the buckling characteristic equation, the method of differential equation was adopted by establishing the bending and torsional differential equation of the jib system under the instability critical state. Compared with the numerical solutions of the finite element software ANSYS, the analytical results in this work agree well with them. Therefore, the correctness of the results in this work can be confirmed. Then the influences of the lateral stiffness of the cable fixed joint, the dip angle of the strut, the inertia moment of the strut, and the horizontal position of the cable fixed joint on the out-of-plane buckling behavior of the jib system were investigated.

이단 평행봉 차오르기 동작의 운동학적 분석 (A Kinematic Analysis of Glide Kip Motion on the Uneven Bars)

  • 김승권;김성은;장대순
    • 한국운동역학회지
    • /
    • 제23권4호
    • /
    • pp.307-318
    • /
    • 2013
  • The purpose of this study was to analyze the kinematic variables of glide kip motion on the uneven bars through a two-dimensional cinematography. Three expert female gymnastics players were involved in the data gathering process. The followings were concluded according to the results. The arm, trunk and leg segments were fully extended throughout the kip movement. The whole body center of gravity showed the biggest changes during 66 to 87% of the kip motion. During the kip phase, the horizontal displacement of the leg was greater than the vertical displacement the leg. Glide kip motion should be done in orders of upward movement of leg, forward movement of leg, upward movement of trunk and forward movement of trunk segment. It was found that trunk segment and hip joint movements showed bigger changes than those of leg segment and shoulder joint in the glide kip motion. The largest angular velocity of hip joint was shown in the middle of the kip Phase. In conclusion, effective kip movement could be resulted when the trunk was displaced posterior-upward direction with fast hip joint extension after the leg segment was elevated upward and thrusted forward in advance.

선형 레이저 광 영상기반 다면 3 차원 스캐너 (Multi-facet 3D Scanner Based on Stripe Laser Light Image)

  • 고영준;이수영
    • 제어로봇시스템학회논문지
    • /
    • 제22권10호
    • /
    • pp.811-816
    • /
    • 2016
  • In light of recently developed 3D printers for rapid prototyping, there is increasing attention on the 3D scanner as a 3D data acquisition system for an existing object. This paper presents a prototypical 3D scanner based on a striped laser light image. In order to solve the problem of shadowy areas, the proposed 3D scanner has two cameras with one laser light source. By using a horizontal rotation table and a rotational arm rotating about the latitudinal axis, the scanner is able to scan in all directions. To remove an additional optical filter for laser light pixel extraction of an image, we have adopted a differential image method with laser light modulation. Experimental results show that the scanner's 3D data acquisition performance exhibited less than 0.2 mm of measurement error. Therefore, this scanner has proven that it is possible to reconstruct an object's 3D surface from point cloud data using a 3D scanner, enabling reproduction of the object using a commercially available 3D printer.

시설화훼용 견인형 방제기의 작업자세 및 성능 분석 (Ergonomic and Performance Analyses of a Pull-type Prayer for Floriculture in Greenhouse)

  • 이승기;김웅
    • Journal of Biosystems Engineering
    • /
    • 제35권6호
    • /
    • pp.426-433
    • /
    • 2010
  • This study was conducted to develop a pull-type sprayer which performs the safe spraying with improved ergonomic postures while pesticide spraying of roses in floricultural facilities. The performance of the ergonomically designed sprayer was analyzed with a comparison of a conventional spray method. The pull-type sprayer, consisting of power pump, hose and nozzle parts was designed to manually pull and spray to upward and horizontal directions. From the analysis of postures with the RULA method, the labor load to arm and wrist using the pull-type sprayer was less than that with conventional power sprayer, so that the intensity of labor reduces. Working capacity with pull-type sprayer was two-fold greater than the conventional power sprayer. After performing pesticide spraying with the pull-type sprayer, the operating cost was reduced to \585,000/yr, which is 79% less than that of cost (\2,197,500/yr) for using conventional power sprayer.

Treatment of a naso-orbito-ethmoid fracture using open reduction and suspension sutures: a case report

  • Youngsu, Na;Chaneol, Seo;Yongseok, Kwon;Jeenam, Kim;Hyungon, Choi;Donghyeok, Shin;Myungchul, Lee
    • 대한두개안면성형외과학회지
    • /
    • 제23권6호
    • /
    • pp.269-273
    • /
    • 2022
  • Naso-orbito-ethmoidal (NOE) fractures are complicated fractures of the mid-face. The treatment of NOE fractures is challenging and a comprehensive treatment strategy is required. We introduce a case of NOE fracture treated with open reduction and suspension sutures. A 28-year-old woman presented with a unilateral NOE fracture. To reduce the frontal process of the maxilla, a suspension suture was made by pulling the fragment using a double arm suture via a transcaruncular incision. The suture thread was placed in the horizontal plane. Another suspension suture on the inferior orbital rim assisted reduction procedure, and they passed through the overlying skin. The reduction alignment could be finely adjusted by tightening the transcutaneous suture threads while checking the degree of bone alignment through the subciliary incision. The two suture threads were suspended using a thermoplastic nasal splint. An additional skin incision on the medial canthal area, which would have resulted in a scar, could be avoided. Four months postoperatively, computed tomography showed an accurate and stable reduction. The patient was satisfied with her aesthetic appearance, and functional deficits were not present.