• 제목/요약/키워드: horizontal angles

검색결과 343건 처리시간 0.029초

팔 외전 시 몸통의 피부 변화량 분석과 이를 활용한 3D 컴프레션 상의 설계 (Design of 3D compression upper wear based on skin deformation during arm abduction)

  • 김남임;오염군;홍경희
    • 한국생활과학회지
    • /
    • 제24권5호
    • /
    • pp.687-700
    • /
    • 2015
  • Lines of non-extension (LoNEs) on torso surface during arm abduction were investigated to provide appropriate location for inserting less-extensible yarns which can be used as seams for design and or clothing pressure variation. As experimental methods, reference points about 3 cm apart were marked on the skin and scanned at 30, $90^{\circ}$ and $135^{\circ}$ arm abduction. Skin deformation was measured by connecting reference points in horizontal, vertical and various angles of diagonal directions. Observation of skin deformation was made within the separated sections of the torso as well as integrated ones to cover the various occasions of design application. LoNEs of front and back torso were provided as mapping lines. Actual compression wear of three types was constructed with different pattern reduction rate at each separated section using LoNEs as boundary cutting lines. Clothing pressure and subjective evaluations of those three compression wear were evaluated by six subjects. LoNEs found in this study were useful as seam lines to differentiate clothing pressure at each part of the body, providing positive wear sensation. It is also expected that LoNEs can be paths for less strechable conductive yarns of IT-integrated upper garments.

지진하중에 대한 복층 배럴볼트 시스템의 동적거동에 대한 연구 (Research on Dynamic Behavior of Double-Layer Barrelvault Arch Systems Subjected to Earthquake Loadings)

  • 신지욱;이기학;정찬우;강주원
    • 한국공간구조학회논문집
    • /
    • 제9권1호
    • /
    • pp.87-94
    • /
    • 2009
  • 본 논문은 지진하중에 대한 복층 배럴볼트 시스템의 동적거동을 조사한 것이다. 시간이력해석에 따른 지진에 대한 거동을 조사하기 위하여 6개의 다른 개각과 각 개각에 대하여 0.5초 간격으로 4개의 추가적인 고유 진동수가 고려되었다. 전체 24개의 해석모델들이 컴퓨터 해석 프로그램인 MIDAS Gen.에 의해 설계되었고 5%의 감쇠비가 고려된 3개의 지진에 대하여 시간이력해석이 수행되었다. 지진이 적용될 때 수평방향에 대한 응답반응만 고려하는 라멘 구조물과는 달리 대공간 구조물의 경우 수평방향 뿐만 아니라 상하 방향의 동적거동을 고려하는 것이 중요하다. 따라서 본 연구에서는 수평방향 지진(H)과 수직방향 지진(V)에 대하여 X-, Y- 그리고 Z- 방향에 대한 동적거동 특성에 대하여 평가하였다. 개각과 진동수에 따른 동적거동 특성을 파악하기 위하여 최대 응답이 나타나는 시간에서 배럴볼트 시스템의 특정 절점들에 대한 가속도 응답비를 살펴보았다. 본 논문에서 동적거동을 조사한 가장 중요한 목적은 본 연구의 최종 목적인 배럴볼트시스템에 대한 등가정적지진력을 구하는 식을 제안하기 위함이다.

  • PDF

측모두부방사선사진을 이용한 상악 중첩 방법의 비교연구 (ARATIVE STUDY OF MAXILLARY SUPERIMPOSITION METHODS ON A LATERAL R NTGENOGRAPHIC CEPHALOMETRY)

  • 진영임
    • 대한소아치과학회지
    • /
    • 제25권1호
    • /
    • pp.197-208
    • /
    • 1998
  • This study was carried out to compare the amount of the maxillary bone remodeling and tooth displacement in each three maxillary superimposition methods, Ricketts, Best-fit, Structural method. Forty cases of the lateral cephalometric radiographs from 27 boys and 13 girls who had been treated to correct anterior cross-bite were selected for the study. The initial radiographs were taken at about 8-year-old and the second radiographs were taken in about 3.3 years later. Followings were the results: 1. With the Structural method, backward movement was shown in PNS, while forward movement was observed in ANS and point A. With the Ricketts method, however, all structures were shown significant backward movement comparing with Structural method(P<0.05). With the Best-fit method, the amount of horizontal movement was similar to that of the Structural method(P>0.05). 2. The palate seemed to be moved downward with Structural method, but there was no measured downward remodeling on nasal floor with Ricketts and Best-fit method(P<0.05). 3. Comparing with Structural method, Ricketts and Best-fit method significantly underestimated the eruption of the teeth by 20% to 30% (P<0.05). 4. The Structural method showed the anteroinferior rotation (43%) and posteroinferior rotation(57%) of the palatal plane, while the Best-fit method showed mostly anterosuperior rotation(87%), but no change was found in the Ricketts method. 5. With the Structural method, there was a statistically significant correlation between the amount of the rotation of the palatal plane and that of N-S line(r=0.86). 6. The measured angles of the long axis of the incisors and molars showed no significant difference in each 3 methods(P>0.05).

  • PDF

Seismic behavior of steel reinforced concrete (SRC) T-shaped column-beam planar and 3D hybrid joints under cyclic loads

  • Chen, Zongping;Xu, Jinjun;Chen, Yuliang;Xue, Jianyang
    • Earthquakes and Structures
    • /
    • 제8권3호
    • /
    • pp.555-572
    • /
    • 2015
  • This paper presents an experimental study of three two-dimensional (2D/planar) steel reinforced concrete (SRC) T-shaped column-RC beam hybrid joints and six 3D SRC T-shaped column-steel beam hybrid joints under low cyclic reversed loads. Considering different categories of steel configuration types in column cross section and horizontal loading angles for the specimens were selected, and a reliable structural testing system for the spatial loading was employed in the tests. The load-displacement curves, carrying capacity, energy dissipation capacity, ductility and deformation characteristics of the test subassemblies were analyzed. Especially, the seismic performance discrepancies between planar hybrid joints and 3D hybrid joints were intensively compared. The failure modes for planar loading and spatial loading observed in the tests showed that the shear-diagonal compressive failure was the dominating failure mode for all the specimens. In addition, the 3D hybrid joints illustrated plumper hysteretic loops for the columns configured with solid-web steel, but a little more pinched hysteretic loops for the columns configured with T-shaped steel or channel-shaped steel, better energy dissipation capacity & ductility, and larger interlayer deformation capacity than those of the planar hybrid joints. Furthermore, it was revealed that the hysteretic loops for the specimens under $45^{\circ}$ loading angle are generally plumper than those for the specimens under $30^{\circ}$ loading angle. Finally, the effects of steel configuration type and loading angle on the seismic damage for the specimens were analyzed by means of the Park-Ang model.

Seismic performance of R/C structures under vertical ground motion

  • Bas, Selcuk;Lee, Jong-Han;Sevinc, Mukadder;Kalkan, Ilker
    • Computers and Concrete
    • /
    • 제20권4호
    • /
    • pp.369-380
    • /
    • 2017
  • The effects of the vertical component of a ground motion on the earthquake performances of semi-ductile high-rise R/C structures were investigated in the present study. Linear and non-linear time-history analyses were conducted on an existing in-service R/C building for the loading scenarios including and excluding the vertical component of the ground motion. The ratio of the vertical peak acceleration to the horizontal peak acceleration (V/H) of the ground motion was adopted as the main parameter of the study. Three different near-source earthquake records with varying V/H ratio were used in the analyses. The linear time-history analyses indicated that the incorporation of the vertical component of a ground motion into analyses greatly influences the vertical deflections of a structure and the overturning moments at its base. The lateral deflections, the angles of rotation and the base shear forces were influenced to a lesser extent. Considering the key indicators of vertical deflection and overturning moments determined from the linear time-history analysis, the non-linear analyses revealed that the changes in the forces and deformations of the structure with the inclusion of the vertical ground motion are resisted by the shear-walls. The performances and damage states of the beams were not affected by the vertical ground motion. The vertical ground motion component of earthquakes is markedly concluded to be considered for design and damage estimation of the vertical load-bearing elements of the shear-walls and columns.

LED 광원을 이용한 디지털 혀 영상 촬영장치의 기구설계와 개발 (Mechanical Design and Development of a Digital Tongue Imaging System Equipped with LEDs)

  • 남동현;김지혜;이상석
    • 대한한의진단학회지
    • /
    • 제16권3호
    • /
    • pp.41-48
    • /
    • 2012
  • Objectives: The aims of this study are to design a optimized mechanical structure of digital tongue imaging system (DTIS) equipped with LEDs in aspects of object distance and camera angle of coverage. Methods and Results: We tried to find optimized object distance while recording a rectangular object of common tongue size. In case object distance is 22 cm or less, edge of the rectangle was not taken beyond the shooting range. In contrast, if object distance is 40 cm or more, the rectangle image was too small. Therefore when considering the variation of subjects, we selected distance of 35-40 cm as appropriate object distance for the DTIS. We also tried to find optimized angle between camera view axis and horizontal line. We photographed from the side of the face of 7 adults with exposed tongue. We drew an exposed tongue lines to connect the tongue tip points and the tongue root points by using the photos acquired from the side faces. And then we calculated the tongue exposure angles between the vertical line and the exposed tongue lines. Mean tongue exposure angle was $28.3^{\circ}$ when tongue was lightly exposed and $13.3^{\circ}$ when maximally. So we determined $73^{\circ}$ as appropriate slope angle of part in contact with face of the DTIS and by considering that the standard variation was great, we designed control gears to adjust the slope of the camera view axis and to regulate the object distance. Conclusions: We designed a optimized mechanical structure in object distance and slope angle of part in contact with face of the DTIS.

Combination rules and critical seismic response of steel buildings modeled as complex MDOF systems

  • Reyes-Salazar, Alfredo;Valenzuela-Beltran, Federico;de Leon-Escobedo, David;Bojorquez-Mora, Eden;Barraza, Arturo Lopez
    • Earthquakes and Structures
    • /
    • 제10권1호
    • /
    • pp.211-238
    • /
    • 2016
  • The Maximum seismic responses of steel buildings with perimeter moment resisting frames (MRF), modeled as complex MDOF systems, are estimated for several incidence angles of the horizontal components and the critical one is identified. The accuracy of the existing rules to combine the effects of the individual components is also studied. Two and three components are considered. The critical response does not occur for principal components and the corresponding incidence angle varies from one earthquake to another. The critical response can be estimated as 1.40 and 1.10 times that of the principal components, for axial load and interstory shears, respectively. The rules underestimate the axial load but reasonably overestimate the shears. The rules are not always inaccurate in the estimation of the combined response for correlated components. On the other hand, totally uncorrelated (principal) components are not always related to an accurate estimation. The correlation of the individual effects (${\rho}$) may be significant, even for principal components. The rules are not always associated to an inaccurate estimation for large values of ${\rho}$, and small values of ${\rho}$ are not always related to an accurate estimation. Only for perfectly uncorrelated harmonic excitations and elastic analysis of SDOF systems, the individual effects of the components are uncorrelated and the rules accurately estimate the combined response. The degree of correlation of the components, the type of structural system, the response parameter under consideration, the location of the structural member and the level of structural deformation must be considered while estimating the level of underestimation or overestimation.

Objective photographic assessments and comparisons of immediate bilateral breast reconstruction using deep inferior epigastric perforator flaps and implants

  • Han, Hyun Ho;Choi, Jin Mi;Eom, Jin Sup
    • Archives of Plastic Surgery
    • /
    • 제48권5호
    • /
    • pp.473-482
    • /
    • 2021
  • Background The increasing number of bilateral breast cancer patients has been accompanied by a growing need for bilateral mastectomy with immediate reconstruction. However, little research has investigated the complications and aesthetic outcomes related to bilateral reconstruction. Therefore, we analyzed retrospective data comparing the outcomes of bilateral reconstruction using deep inferior epigastric perforator (DIEP) flaps or implants. Methods This study included 52 patients (24 DIEP group and 28 implant group) who underwent bilateral mastectomy with immediate reconstruction between 2010 and 2020. Patient demographics, surgical characteristics, and complications were recorded. The difference between the left and right position of the nipple-areolar complex with respect to the sternal notch point at the clavicle was measured, and breast symmetry was evaluated. Results The average weight of breasts reconstructed with DIEP flaps (417.43±152.50 g) was higher than that of breasts with implants. The hospitalization period and operation time were significantly longer in the DIEP group. Early complications were significantly more common in the implant group (36.53%) than in the DIEP group. The angles between the nipples and the horizontal line were 1.09°±0.71° and 1.75°±1.45° in the DIEP and implant groups, respectively. Conclusions Although the surgical burden is lower, breast reconstruction using implants requires greater attention with respect to implant positioning, asymmetry, and complications than DIEP flap reconstruction. DIEP flap reconstruction has a prolonged operation time and a high risk of flap failure, but yields excellent cosmetic results and does not require intensive follow-up. Patients should be consulted to determine the most suitable option for them.

몬테칼로 방법을 이용한 방사성 불소에 대한 L-블럭형 방호장비의 차폐율 및 공간의 선량분포 계산 (Calculation of Shielding Rate and Dose Distribution of Space of L-Block-Type Protective Equipment for Radioactive Fluorine using the Monte Carlo Method)

  • 한동현
    • 한국방사선학회논문지
    • /
    • 제15권6호
    • /
    • pp.813-819
    • /
    • 2021
  • 본 연구에서는 방사성 불소의 인체 내 주입 시 방사선 방호목적으로 사용되는 L-블럭형 방호장비의 차폐율과 주변공간의 선량분포를 몬테칼로 방법을 이용해 계산하였다. L-블럭형 차폐장치의 몸체 및 윈도우 부위의 차폐율은 99.99 %였다. 1 m거리에서 계산한 선량분포는 XZ평면의 135°, 45°, 225°, 315°, 180°에서 상대적으로 높게 나타났고, 0°, 90°, 270°에서는 매우 낮게 계산되었다. YZ평면에서는 135°, 180°, 225°에서 상대적으로 높게 나타났고, 나머지 각도에서는 매우 낮게 계산되었다. AZ와 BZ 평면에서도 YZ평면과 유사한 결과를 나타냈다. 또한 선원의 수평방향과 선원의 상방 45°방향의 선량분포를 통해 225°~315°범위에서 차폐율이 가장 우수함을 확인하였다. 이와 같은 결과가 방사선 작업 종사자들의 방사선 방호에 필요한 기초자료로 활용되기를 기대한다.

치위생과 학생의 치과방사선 팬텀활용 촬영실습 분석 (Analysis of dental radiography phantom practice of dental hygiene students)

  • 원복연;황미영;장계원;허남숙;윤미숙;박성숙
    • 한국치위생학회지
    • /
    • 제18권6호
    • /
    • pp.1013-1023
    • /
    • 2018
  • Objectives: The purpose of this study is to evaluate dental hygiene students' recognition of safety management and phantom practice in dental radiology. Methods: The study subjects were 409 students in six regions who completed a dental radiology practice course and had on-job experience more than once. After understanding the study purpose and contents, they answered a questionnaire. The main jobs in dental radiology were analyzed. Results: As a result, regarding the most difficult aspects of dental radiology practice, "it is impossible to irradiate the mouth directly with X-rays" was the most common response (29.1%). Regarding the question "what is the main role of students in dental radiology practice?", the answer "it is shooting simulations using phantoms" accounted for 59.7% of responses. The most difficult regions in bisecting and paralleling radiography with a phantom were found to be the maxillary & mandibular molars and premolars. The most difficult technique was reported to be locating XCP maintenance to fit inside the mouth for both molars and premolars. The most difficult region to perform bitewing radiography using the phantom was the molar region (2.87), and the most difficult to perform occlusal radiography approaches were maxillary anterior general occlusal radiography (2.92) and mandibular cross-sectional occlusal radiography (3.00). Conclusions: The most technically difficult point in bitewing and occlusal radiography was the correct positioning of the vertical and horizontal angles. Radiography practice was considered to be more effective than previous mutual practice in terms of analysis of anatomical structures and patient treatment methods. Therefore, it will be necessary to improve policy regarding dental radiography practice at the department of dental hygienics and revise the necessary laws and regulations.