• 제목/요약/키워드: holography method

검색결과 203건 처리시간 0.023초

진폭 마스크와 2D 카오스 함수를 이용한 다중 이미지 광학 암호화 (Optical encryption of multiple images using amplitude mask and 2D chaos function)

  • 김활;전성빈;김도형;박노철;박영필
    • 정보저장시스템학회논문집
    • /
    • 제10권2호
    • /
    • pp.50-54
    • /
    • 2014
  • Object image using DRPE(Double Random Phase Encryption) in 4f system is encrypted by space-division method using amplitude mask. However, this method has the weakness for the case of having partial data of amplitude mask which can access the original image. To improve the security, we propose the method using the 2-dimension logistic chaos function which shuffles the encrypted data. It is shown in simulation results that the proposed method is highly sensitive to chaos function parameters. To properly decrypt from shuffled encryption data, below 1e-5 % errors of each parameter should be required. Thus compared with conventional method the proposed shows the higher security level.

주행 중 철도 차량의 결함 위치 추정 방법 (Fault localization method of a train in cruise)

  • 전종훈;김양한
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 추계학술대회 논문집
    • /
    • pp.903-912
    • /
    • 2007
  • Faults of rotating parts of a train normally generate unexpected frequency band or impulsive sound[1] which has a period when it moves with a constant speed. The former can be detected by the moving frame acoustic holography method, which visualizes sound field that is generated by a moving and emitting pure tone or band limited noise source. We have attempted to apply the method to the latter case: the periodic impulsive sound which generate different signal compared with what can be measured by the band limited noise. The signal to noise ratio which determines the success of early fault detection must also be studied with the impulsive and moving signal. This research shows how the problems related with these issues can be resolved. The main idea is that periodic impulsive signal can be expressed by infinite set of discrete pure tones. This enables us to obtain lots of holograms that visualize periodic impulsive sound field including noise by using the moving frame acoustic holography method. Therefore holograms can be averaged to improve the signal to noise ratio until having reliable information that exhibits where the impulsive sources are. Theory and experiment by using the miniature vehicle are described [Work supported by BK21 & KRRI].

  • PDF

반사형 디지털 홀로그래피를 이용한 Molybdenum 박막의 손상 측정 (Damage Measurement for Molybdenum Thin Film Using Reflection-Type Digital Holography)

  • 김경석;정현일;신주엽;마혜준;권익환;양승필;홍정기;정현철
    • 비파괴검사학회지
    • /
    • 제35권2호
    • /
    • pp.141-149
    • /
    • 2015
  • 전자제품에 필수적으로 사용되는 전자회로의 제작 시, 반도체 위에 증착하는 박막의 산화를 방지하기 위하여 molybdenum을 증착한다. Molybdenum 박막 증착 시 표면의 particle 또는 dust의 존재는 밀착력 감소 및 성능 저하, 수명 단축, 안전도 저하를 유발한다. 본 논문에서는 particle의 유무에 따른 molybdenum 박막 증착부의 변화를 보기 위하여, 두 가지 glass substrate를 대상으로 손상 측정 실험을 하였다. Sputtering 증착 기법으로 molybdenum이 glass substrate에 직접 코팅이 되는 clean과 dirty 두 종류의 molybdenum 박막을 제작하고, 손상 측정을 위해 반사형 디지털 홀로그래피를 구성하였다. 반사형 디지털 홀로그래피는 간섭계의 구성이 손쉽고 다양한 배율렌즈를 적용하여 측정영역에 다양성을 줄 수 있으며, 측정시간이 타 기법에 비해 짧다는 장점을 가진다. 실험 결과로부터 반사형 디지털 홀로그래피가 박막의 손상 및 결함 측정에 유용한 기술임을 확인하였다.

디지털 홀로그래피에서 퓨리어 변환을 이용한 0차 회절광의 제거와 위상홀로그램의 생성에 대한 전산 모사 (Computer simulation of the removal of the 0-th order diffraction by using fourier transform in digital holography)

  • 김성규;박민철;이석;김재순;손정영
    • 한국광학회지
    • /
    • 제15권1호
    • /
    • pp.39-45
    • /
    • 2004
  • CCD의 입력면에서의 물체광과 참조광의 간섭을 수치적 방법으로 생성한 광 강도 분포 홀로그램을 대상으로 퓨리어 변환방법을 이용한 0차 회절광의 제거를 전산 모사 방법으로 구현하였고, 0차 회절광 성분이 제거된 광 강도 분포와 위상을 갖는 홀로그램을 생성하였다. 그리고 그 결과를 수치적 재생 방법을 사용하여 0차 회절광 성분의 제거를 확인하였다. 그리고 퓨리어 변환 방법에 의한 0차 회절광 성분이 제거된 위상홀로그램의 생성이 가능하다. 0차 회절광을 제거하기 위한 제거 함수를 도입하였고 제거 영역에 따른 0차 회절광의 제거와 재생되는 실상의 정보 손실 정도를 비교하였고, 기존의 방법에 비하여 효과적임을 증명하였다.

공간 포락을 적용한 시간 영역 음장 가시화 (Sound Visualization in Time Domain by Using Spatial Envelope)

  • 박춘수;김양한
    • 한국소음진동공학회논문집
    • /
    • 제18권1호
    • /
    • pp.20-25
    • /
    • 2008
  • 음향홀로그래피는 시간 영역 혹은 주파수 영역에서 음압의 공간 분포를 가시화하는 방법이다. 그러나, 재구성된 음압은 종종 실제적으로 우리가 원하는 음장의 정보보다 훨씬 많은 정보를 가지고 있다. 예를 들어, 우리가 소음 제어를 위해 필요로 하는 정보는 소음원의 위치와 전체적인 방사형태의 정보만으로 충분하다. 따라서, 이렇게 필요로 하는 정보만을 보여줄 수 있는 방법이 필요하다 볼 수 있다. 이를 위한 한 가지 방법으로 공간에서의 포락을 생각할 수 있다. 공간복소포락은 소음원의 위치와 느리게 변하는 전체적인 변화에 대한 정보를 가지고 있는 포락 신호를 의미한다. 공간복소포락을 이용함으로써, 우리는 음장에서 불필요한 정보를 제거하여 필요한 정보를 얻을 수 있을 뿐만 아니라, 가시화 과정에서의 연산 시간도 줄일 수 있다. 이 공간포락을 얻기 위한 공간변조 방법을 이론적으로 유도하고 제안한다. 그리고, 여러 개의 단극음원에 의해 형성되는 복잡한 음장을 제안하는 방법을 이용해 단순화시킨 결과를 통해 제안하는 방법에 대한 타당성을 검증한다.

Research on the Effects of Boundary Element Characteristics on Reconstruction Accuracy by BEM-based NAH

  • Zhang, Hai-Bin;Kim, Yang-Hann;Jiang, Wei-Kang
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 추계학술대회 논문집
    • /
    • pp.630-635
    • /
    • 2012
  • Nearfield acoustic holography method predicts an unmeasured sound field, therefore it depends on its prediction methods. In particular, if one has radiators or scatters, which cannot be expressed by simple geometry, then inverse boundary element method (BEM) is normally employed to reconstruct the sound field induced by sound sources with irregular profiles. The characteristics of boundary element, including the element shape, characteristic length, order of shape function and others, affect the reconstruction error. Investigating the errors by means of changing these factors will provide a guide line for selecting appropriate factors, associated with the elements of BEM. These factors are investigated by numerical simulations, and the accuracies with respect to the variant factors are compared. Novel suggestions for selecting appropriate boundary element factors are described based on the simulation results.

  • PDF

Improving the quality of light-field data extracted from a hologram using deep learning

  • Dae-youl Park;Joongki Park
    • ETRI Journal
    • /
    • 제46권2호
    • /
    • pp.165-174
    • /
    • 2024
  • We propose a method to suppress the speckle noise and blur effects of the light field extracted from a hologram using a deep-learning technique. The light field can be extracted by bandpass filtering in the hologram's frequency domain. The extracted light field has reduced spatial resolution owing to the limited passband size of the bandpass filter and the blurring that occurs when the object is far from the hologram plane and also contains speckle noise caused by the random phase distribution of the three-dimensional object surface. These limitations degrade the reconstruction quality of the hologram resynthesized using the extracted light field. In the proposed method, a deep-learning model based on a generative adversarial network is designed to suppress speckle noise and blurring, resulting in improved quality of the light field extracted from the hologram. The model is trained using pairs of original two-dimensional images and their corresponding light-field data extracted from the complex field generated by the images. Validation of the proposed method is performed using light-field data extracted from holograms of objects with single and multiple depths and mesh-based computer-generated holograms.

바이어스와 공액영상이 제거된 인코히어런트 삼각 홀로그래피에 대한 이론적 연구 (Theoretical study on incoherent triangular holography without bias and conjugate image)

  • 김수길;김은수;이혁;이병호
    • 전자공학회논문지A
    • /
    • 제33A권10호
    • /
    • pp.144-151
    • /
    • 1996
  • In this paper, the theoretical analysis and the computer simulation of a new modified cochran's triangular interferometer as an incoherent holography, which can eliminate bias and conjugate image problems of the conventional cochran's triangular interferometer, are spresented. In other words, it is theoretically derived by using jones matrix operation that bias and conjugate image can be removed by adding simple optical components including a polarizing beam splitter, wave plates, and linear polarizers to the conventional with a point source, we demonstrated the validity of the suggested method by comparing the modified cocharan's triangular interferometer with the conventional one.

  • PDF

Laser holography를 이용한 상악 headgear견인에 따른 안면두개골의 초기반응에 관한 연구 (A STUDY ON THE INITIAL REACTION OF CRANIOFACIAL COMPLEX TO MAXILLARY HEADGEAR TRACTION BY LASER HOLOGRAPHY)

  • 김충배;양원식
    • 대한치과교정학회지
    • /
    • 제16권2호
    • /
    • pp.31-41
    • /
    • 1986
  • The purpose of this study is to examine the initial reaction of craniofacial complex to the traction of headgears which are frequent used in dinical practice by using holographic interference method. Changes in the fringe pattern according to the traction conditions (outer bow length, load amount, direction) were compared. Human dry skull was used as experimental material, the results were as follows. 1. The density of fringes increased with an increase in load. 2. Maxillary headgear affected circummaxillary bones-temporal bone, zygomatic bone, nasal bone, frontal bone, sphenoid bone as well as maxilla. 3. The most upward-backward displacement was observed in a high pull head gear $(30^{\circ})$, this is though to be a optimal direction for supressing the growth of the maxilla.

  • PDF

이미지 분리를 이용한 입자 속도 측정을 위한 홀로그래피 시스템의 개발 (Development of New Holography System for Measurments of Particle Velocities Using Separation of Images)

  • 강보선
    • 한국분무공학회지
    • /
    • 제2권2호
    • /
    • pp.16-23
    • /
    • 1997
  • In this research a novel two-reference-beam double pulse holographic technique for the measurments of particle sizes and velocities was developed. This holographic method features the capability of separation of the first and second particle images by using two reference beams instead of one and the change of the polarization direction of laser light. The developed holographic system was tested through the measurements of droplet sizes and velocities in the spray created by two high speed impinging jets. The overall spray pattern clearly revealed the inherent wave nature. Smaller and faster droplets were generated with larger impingement angle, higher jet velocity. and smaller orifice diameter.

  • PDF