• Title/Summary/Keyword: hollow-tube

Search Result 186, Processing Time 0.024 seconds

Experimental investigation on the room temperature active magnetic regenerator with permanent magnet array (영구자석 배열을 이용한 능동형 자기재생 냉동기에 대한 실험적 연구)

  • Kim, Young-Kwon;Jeong, Sang-Kwon
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.186-191
    • /
    • 2008
  • In this study, a room temperature AMRR (Active magnetic regenerative refrigerator) was fabricated, and experimentally investigated. Gadolinium (Gd) was selected as a magnetic refrigerant with Curie temperature of 293 K. Permanent magnet was utilized to magnetize and demagnetize the AMR. To produce large magnetic field above 1 T in the magnetic refrigeration space, a special arrangement of permanent magnets, so called Halbach array, is employed. Sixteen segments of the permanent magnets magnetized different direction, constitute a hollow cylindrical shaped permanent magnet. The AMR is reciprocated along the bore of the magnet array and produces cooling power. Helium is selected as the working fluid and a helium compressor is utilized to supply helium flow to the regenerator. The fabricated AMRR has different structure and compared to a convectional AMRR since it has an additional volume after the regenerator. Therefore, the cooling ability is generated not only by magnetocaloric effect of magnetic refrigerant but also by the pulse tube effect. It is verified that the cooling ability of AMR is increased due to the magnetocalric effect by the fact that the temperature span becomes $16^{\circ}C$ while the temperature span is only $8^{\circ}C$ when the magnetic field is not applied to the regenerator.

  • PDF

Eccentric Axial Load Test for Concrete-Filled Tubular Columns Encased with Precast Concrete (프리캐스트 콘크리트에 의해 피복된 콘크리트충전 강관기둥의 편심압축실험)

  • Lee, Ho Jun;Park, Hong Gun;Kim, Sung Bae;Park, Sung Soon
    • Journal of Korean Society of Steel Construction
    • /
    • v.26 no.1
    • /
    • pp.31-42
    • /
    • 2014
  • In this paper, concrete-filled steel tubular columns encased with precast reinforced concrete were studied. Four eccentrically loaded columns and a concentrically loaded column were tested to investigate the axial load-carrying capacity. The test parameters were the use of fiber reinforcement for cover concrete, eccentricity, column length, and lateral reinforcement. The maximum axial loads of the specimens agreed with the nominal strengths predicted by KBC 2009. However, in some specimens, the load carrying capacity quickly decreased after the peak strength due to spalling of the cover concrete.

Study on the Fluid Dynamics Modeling in Artificial Lung Assist Device (인공 폐 보조장치 내에서의 유체 유동 모델링에 대한 연구)

  • Kim, Gi-Beum;Park, Young-Ran;Kim, Shang-Jin;Hong, Chul-Un;Kang, Hyung-Sub;Kim, Jin-Shang;Kim, Seong-Jong;Kim, Min-Ho
    • Korean Chemical Engineering Research
    • /
    • v.49 no.2
    • /
    • pp.230-237
    • /
    • 2011
  • In this study, the characteristic of fluid flow in the new type lung assist devices has been established using computational fluid dynamics(CFD). For the modeling, the hollow fiber was ignored, and vertical types and tangential types were used for the model. Which was to analyze the flow characteristics of the fluid flow model when there exists 1 and 2 input/output ports, and when the input/output ports is located at the center of the cylinder and at the tangential direction with the cylinder wall. The modeling results showed that it was possible to eliminate no-flow region(stagnant layer) as shown in the vertical type when an inlet and an outlet were installed on the tangential direction of the cylinder as shown in the tangential type. Also, in the tangential type, vortex-type flow appeared as dominant, and it showed a complicated flow not deviated to one side. When the number of input/output was two, there was no deviated flow, and complicated flows were generated all across the tube. From the test result, it was found that input/output of flow was tangential type and complicated flows with no stagnant layer would be generated when there are two inputs/outputs, respectively.

Study on High Degree of Efficiency Chemical Reactor for Air Purification Using the Glow Discharge (글로우 방전을 이용한 고효율 공기 정화용 화학 반응기의 특성관찰에 관한 연구)

  • Kim, Gi-Ho;Bu, Min-Ho;Lee, Sang-Cheon
    • Journal of the Korean Chemical Society
    • /
    • v.50 no.1
    • /
    • pp.14-22
    • /
    • 2006
  • the basic model of chemical reactor using glow discharge, we used cathode discharge cell with vacant cavity in the middle. Currently glow discharge is widely studied as a radiation source or atomization device in atomic spectroscopy and remarkable technological achievements are made through the graft with other analysis devices such as microanalysis and steel analysis.1 Additionally, as the characteristics of basic glow discharge and radiation have been reviewed many times, those results could be used in this experiment.2-3 In 1993, an article regarding the treatment of poisonous gas in the air using low temperature plasma was published. According to this article, if DC Glow Discharge is used under continuous atmospheric flow, poisonous gases such as SO2 and NO can be removed.4 Based on those findings, we designed highly efficient reactor where stable air plasma is composed and all air flow pass the negative glow area passing through the tube. It was observed that the cathode tube type glow discharge developed in this study would be economical, easy to use and could be used as radiation source as well.

Fatigue Damage Detection and Vibration Sensing Using Intensity-Based Optical Fiber Sensors (광강도형 광섬유센서를 이용한 피로손상 및 진동감지)

  • 양유창;전호찬;한경섭
    • Composites Research
    • /
    • v.13 no.1
    • /
    • pp.89-97
    • /
    • 2000
  • Fatigue damage detection and vibration sensing for a laminated composites and impact location detection for a steel beam have been carried out using optical fiber sensor. Intensity based optical fiber sensor is constructed by placing two cleaved fiber end in a hollow glass tube, and multiple reflection within the cavity is considered. Fatigue signals are measured by embedded optical fiber, surface mounted optical fiber sensor and strain gage simultaneously. For vibration sensing, optical fiber sensor is mounted on the carbon fiber composite beam and its response to free vibration and forced vibration is investigated. In impact location detection, two optical fiber sensors are used and the information obtained from two sensors is arrival time delay of vibration caused by impact. Impact location can be calculated from this time delay. The obtained results show that the intensity based optical fiber sensor provide reliable data during long-term fatigue loading, unlike strain gage which deteriorate during the early part of the fatigue test. Optical fiber sensor signals coincide with gap sensor in vibration sensing. The precise locations of impact can be detected within 4.1% error limit.

  • PDF

Adsorption of Heavy Metal Ions onto Chemically Oxidized Ceiba pentandra (L.) Gaertn. (Kapok) Fibers

  • Chung, Byung-Yeoup;Cho, Jae-Young;Lee, Min-Hee;Wi, Seung-Gon;Kim, Jin-Hong;Kim, Jae-Sung;Kang, Phil-Hyun;Nho, Young-Chang
    • Journal of Applied Biological Chemistry
    • /
    • v.51 no.1
    • /
    • pp.28-35
    • /
    • 2008
  • The physico-chemical properties of kapok fibers were altered via the combination processes of chlorite-periodate oxidation, in order to assess their efficacy as a heavy metal adsorbent. The chemically-oxidized kapok fibers were found to harbor a certain amount of polysaccharides, together with lowered lignin content. This alteration in lignin characteristics was clearly confirmed via FTIR and NBO yield. Moreover, chemically oxidized kapok fibers retained their hollow tube shape, although some changes were noted. The chemically oxidized kapok fibers evidenced elevated ability to adsorb heavy metal ions with the best fit for the Langmuir adsorption isotherm model. Three cycles of adsorption-desorption were conducted with in-between regeneration steps. Our experimental results indicated that chemically oxidized kapok fibers possessed excellent adsorption characteristics, and the modified kapok fibers could be completely regenerated with almost equimolar diluted sodium hydroxide. Pb, Cu, Cd and Zn ions evidenced adsorption rates of 93.55%, 91.83%, 89.75%, and 92.85% on the chemically oxidized kapok fibers. The regeneration efficiency showed 73.58% of Pb, 71.55% of Cu, 66.87% of Cd, and 75.00% of Zn for 3rd cycle with 0.0125N NaOH.

Experimental Study on the Behavior of Circular Steel Tube Columns using HSB600 Steel (HSB600 원형강관 기둥의 거동에 대한 실험적 연구)

  • Kim, Sun Hee;Choi, Young Hwan;Choi, Sung Mo
    • Journal of Korean Society of Steel Construction
    • /
    • v.24 no.6
    • /
    • pp.743-751
    • /
    • 2012
  • This paper investigates an experimental behavior of circular columns and beam-columns made of HSB600 high strength steel as a fundamental study to enhance the applicability of HSB steel. The applicability of the current Standard such as KBC and Eurocode 3 is also evaluated. A total of six specimens are fabricated and tested. The main parameters are slenderness ratio(KLe/r = 12, 14, 40, 65), diameter-to-thickness ratio(D/t = 25, 40), and eccentricity ratio(e/D = 0, 0.5). It is drawn from the experiment that both the KBC and Eurocode 3 can be used to predict the strength of circular columns and beam-columns made of HSB600 high strength steel.

Seismic behavior of stiffened concrete-filled double-skin tubular columns

  • Shekastehband, B.;Mohammadbagheri, S.;Taromi, A.
    • Steel and Composite Structures
    • /
    • v.27 no.5
    • /
    • pp.577-598
    • /
    • 2018
  • The imperfect steel-concrete interface bonding is an important deficiency of the concrete-filled double skin tubular (CFDST) columns that led to separating concrete and steel surfaces under lateral loads and triggering buckling failure of the columns. To improve this issue, it is proposed in this study to use longitudinal and transverse steel stiffeners in CFDST columns. CFDST columns with different patterns of stiffeners embedded in the interior or exterior surfaces of the inner or outer tubes were analyzed under constant axial force and reversed cyclic loading. In the finite element modeling, the confinement effects of both inner and outer tubes on the compressive strength of concrete as well as the effect of discrete crack for concrete fracture were incorporated which give a realistic prediction of the seismic behavior of CFDST columns. Lateral strength, stiffness, ductility and energy absorption are evaluated based on the hysteresis loops. The results indicated that the stiffeners had determinant role on improving pinching behavior resulting from the outer tube's local buckling and opening/closing of the major tensile crack of concrete. The lateral strength, initial stiffness and energy absorption capacity of longitudinally stiffened columns with fixed-free end condition were increased by as much as 17%, 20% and 70%, respectively. The energy dissipation was accentuated up to 107% for fixed-guided end condition. The use of transverse stiffeners at the base of columns increased energy dissipation up to 35%. Axial load ratio, hollow ratio and concrete strength affecting the initial stiffness and lateral strength, had negligible effect of the energy dissipation of the columns. It was also found that the longitudinal stiffeners and transverse stiffeners have, respectively, negative and positive effects on ductility of CFDST columns. The conclusions, drawn from this study, can in turn, lead to the suggestion of some guidelines for the design of CFDST columns.

Vibration Sensing and Impact Location Measurement Using Intensity-Based Optical Fiber Vibration Sensor (광강도형 광섬유 진동센서를 이용한 진동감지 및 충격위치 측정)

  • 양유창;황운봉;박현철;한경섭
    • Composites Research
    • /
    • v.13 no.5
    • /
    • pp.1-9
    • /
    • 2000
  • An intensity-based optical fiber vibration sensor is applied to monitor the structural vibration and detect impact locations on a plate. Optical fiber vibration sensor is constructed by placing two cleaved fiber end, one of which is cantilevered in a hollow glass tube. The movement of the cantilevered section lags behind the rest of the sensor in response to an applied vibration and the amount of light coupled between the two fibers is thereby modulated. For vibration sensing, optical fiber vibration sensor is mounted on the carbon fiber composite beam and its response is investigated to free and forced vibration. In impact location detection, four optical fiber vibration sensors whose location is predetermined are placed at chosen positions and the different arrival times of impact-generated vibration signal are recorded by an FFT analyzer. Impact location can be calculated from these time delays. Experimental results show that optical fiber vibration sensor signals coincide with gap sensor in vibration sensing. The precise location of impact can be detected on an acrylate plate.

  • PDF

Study on Critical Impact Point for a SB2 Class Flexible Barrier (SB2등급 연성베리어의 충돌지점(CIP)에 대한 연구)

  • Heo, Yeon Hee;Kim, Yong Guk;Ko, Man Gi;Kim, Kee Dong
    • International Journal of Highway Engineering
    • /
    • v.15 no.4
    • /
    • pp.127-133
    • /
    • 2013
  • PURPOSES : The impact performance of flexible barrier system such as structural response, vehicular motion and occupant safety vary depending on the impact point. Thus, to properly evaluate the performance of a flexible barrier system, impact should be made to a point which will lead to the worst possible results. This point is called the Critical Impact Point (CIP). This paper presents the way to determine the CIP for a SB2 class flexible barrier system which is consisted of Thrie-Beam rail and circular hollow tube post of 2m span. METHODS: Barrier VII simulations were made for impact points; Case 1 at a post, Case 2 at 1/3 span downstream from a post, Case 3 at middle of the span, Case 4 at 2/3 span downstream from a post. For the structural performance (deflections), impact simulation of 8000kg-65km/h-15degree was used, and for vehicle motion and occupant safety, simulation of 1300kg-80km/h-20degree impact was made and analysed. RESULTS: Case 1 gave the largest dynamic deflection of 75.72cm and also gave the largest snag value of 44.3cm. Occupant safety and exit angle of the vehicle after the impact were not sensitive to the impact point and were all below the allowable limit. CONCLUSIONS : For the SB2 class flexible barrier system's CIP can be regarded as a post which is sufficiently away from the end of Length of Need in order to avoid the end-effect of the barrier system. It can be more economic in the long run because the normal concrete pavement material is likely to cost more due to higher probability of maintenance and repair and higher social cost due to traffic accident, etc.