• Title/Summary/Keyword: higher order accuracy

Search Result 791, Processing Time 0.031 seconds

Case Report on Improvement of Reproduction Rate in Hanwoo Farms (한우 농장별 번식기록 분석을 통한 번식률 제고 사례 연구)

  • Kim, Ui Hyung;Chung, Ki Yong;Lee, Seung Hwan;Ryu, Il Sun;Kang, Hee Seol
    • Journal of Embryo Transfer
    • /
    • v.29 no.1
    • /
    • pp.7-12
    • /
    • 2014
  • This work was conducted to study the improvement of reproduction rate from the breeding data collected from four farms from January 2007 to October 2010. The average numbers of service per conception were 1) A farm $1.7{\pm}0.1$ times, 2) B farm $1.5{\pm}0.1$ times, 3) C farm $1.5{\pm}0.1$ times, 4) D farm $1.4{\pm}0.1$ times. The average days from calving to conception was $77.4{\pm}4.8$ days in A farm, $150.8{\pm}11.2$ days in B farm, $90.4{\pm}4.5$ days in C farm, and $71.4{\pm}2.5$ days in D farm. Number of artificial insemination (AI) service per conception was higher at the 30 days before first AI ($2.1{\pm}0.2$ times) than at the 31 days after first AI, and the days from calving to conception were shorter at the 90 days before first AI than at the 91 days after first AI. After timed AI (TAI) treatment, the pregnancy rate was 60.3% for the 58 cows with reproductive disorder. In order to improvement of reproduction rates, the farms has to improve the accuracy of estrus detection, pregnancy diagnosis, check-up for reproductive health, and control of day for first AI periods after calving. The result suggests that farmers need the careful management and reproductive examination of farm animals to improve of reproductive efficiency.

Extraction of Sternocleidomastoid Muscle for Ultrasound Images of Cervical Vertebrae (경추 초음파 영상에서 흉쇄유돌근 추출)

  • Kim, Kwang-Baek
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.11
    • /
    • pp.2321-2326
    • /
    • 2011
  • Cervical vertebrae are a complex structure and an important part of human body connecting the head and the trunk. In this paper, we propose a method to extract sternocleidomastoid muscle from ultrasonography images of cervical vertabrae automatically. In our method, Region of Interests(ROI) is extracted first from an ultrasonography image after removing unnecessary auxiliary information such as metrics. Then we apply Ends-in search stretching algorithm in order to enhance the contrast of brightness. Average binarization is then applied to those pixels which its brightness is sufficiently large. The noise part is removed by image processing algorithms. After extracting fascia encloses sternocleidomastoid muscle, target muscle object is extracted using the location information of fascia according to the number of objects in the fascia. When only one object is to be extracted, we search downward first to extract the target muscle area and then search from right to left to extract the area and merge them. If there are two target objects, we extract first from the upper-bound of higher object to the lower-bound of lower object and then remove the fascia of the target object area. Smearing technique is used to restore possible loss of the fat area in the process. The thickness of sternocleidomastoid muscle is then calculated as the maximum thickness of those extracted objects. In this experiment with 30 real world ultrasonography images, the proposed method verified its efficacy and accuracy by health professionals.

AC-DC Transfer Characteristics of a Bi-Sb Multijunction Thermal Converter (Bi-Sb 다중접합 열전변환기의 교류-직류 변환 특성)

  • 김진섭;이현철;함성호;이종현;이정희;박세일;권성원
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.35D no.11
    • /
    • pp.46-54
    • /
    • 1998
  • A planar Bi-Sb multijunction thermal converter, which is consisted of a linear or bifilar thin film NiCr-heater and a thin film Bi-Sb thermopile, has been fabricated, and its ac-dc transfer characteristics were examined in a frequency range from 10 Hz to 10 KHz. In order to increase the thermal sensitivity and to decrease the ac-dc transfer error of a thermal converter, the heater and the hot junctions of a thermopile were prepared on a Si$_3$N$_4$/SiO$_2$/Si$_3$N$_4$-diaphragm which acts as a thermal isolation layer, and the cold junctions on the Si$_3$N$_4$/SiO$_2$/Si$_3$N$_4$-thin film supported with the silicon rim which functions as a heat sink. The respective thermal sensitivities in air and in a vacuum of the converter with a built-in bifilar heater were about 14.0 ㎷/㎽ and 54.0 ㎷/㎽, and the ac-dc voltage and the current transfer difference ranges in air were about $\pm$0.60 ppm and $\pm$0.11 ppm, respectively, indicating that the ac-dc transfer accuracy of the converter are much higher than that of a commercial 3-dimensional multijunction thermal converter. However, the output thermoelectric voltage fluctuation of the converter was rather high.

  • PDF

A Study on the Prediction of Buried Rebar Thickness Using CNN Based on GPR Heatmap Image Data (GPR 히트맵 이미지 데이터 기반 CNN을 이용한 철근 두께 예측에 관한 연구)

  • Park, Sehwan;Kim, Juwon;Kim, Wonkyu;Kim, Hansun;Park, Seunghee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.7
    • /
    • pp.66-71
    • /
    • 2019
  • In this paper, a study was conducted on the method of using GPR data to predict rebar thickness inside a facility. As shown in the cases of poor construction, such as the use of rebars below the domestic standard and the construction of reinforcement, information on rebar thickness can be found to be essential for precision safety diagnosis of structures. For this purpose, the B-scan data of GPR was obtained by gradually increasing the diameter of rebars by making specimen. Because the B-scan data of GPR is less visible, the data was converted into the heatmap image data through migration to increase the intuition of the data. In order to compare the results of application of commonly used B-scan data and heatmap data to CNN, this study extracted areas for rebars from B-scan and heatmap data respectively to build training and validation data, and applied CNN to the deployed data. As a result, better results were obtained for the heatmap data when compared with the B-scan data. This confirms that if GPR heatmap data are used, rebar thickness can be predicted with higher accuracy than when B-scan data is used, and the possibility of predicting rebar thickness inside a facility is verified.

Comparison of Quantitative Interfacial Adhesion Energy Measurement Method between Copper RDL and WPR Dielectric Interface for FOWLP Applications (FOWLP 적용을 위한 Cu 재배선과 WPR 절연층 계면의 정량적 계면접착에너지 측정방법 비교 평가)

  • Kim, Gahui;Lee, Jina;Park, Se-hoon;Kang, Sumin;Kim, Taek-Soo;Park, Young-Bae
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.25 no.2
    • /
    • pp.41-48
    • /
    • 2018
  • The quantitative interfacial adhesion energy measurement method of copper redistribution layer and WPR dielectric interface were investigated using $90^{\circ}$ peel test, 4-point bending test, double cantilever beam (DCB) measurement for FOWLP Applications. Measured interfacial adhesion energy values of all three methods were higher than $5J/m^2$, which is considered as a minimum criterion for reliable Cu/low-k integration with CMP processes without delamination. Measured energy values increase with increasing phase angle, that is, in order of DCB, 4-point bending test, and $90^{\circ}$ peel test due to increasing roughness-related shielding and plastic energy dissipation effects, which match well interfacial fracture mechanics theory. Considering adhesion specimen preparation process, phase angle, measurement accuracy and bonding energy levels, both DCB and 4-point bending test methods are recommended for quantitative adhesion energy measurement of RDL interface depending on the real application situations.

A STUDY ON THE PHYSICAL PROPERTIES AND VOLUMETRIC STABILITY OF SR-IVOCAP RESIN SYSTEM (SR-Ivocap resin system의 물리적 특성과 체적 안정성에 관한 연구)

  • Eun, Sung-Sik;Kweon, Hyeog-Sin;Chung, Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.3
    • /
    • pp.453-467
    • /
    • 1998
  • This study helps to clarify conflicting reports by comparing the physical properties and accuracy of complete denture processed by the pack and press technique, continuous- pressure injection technique(SR-Ivocap system) and Mark press technique. The 6 different specimens have been evaluated using the SEM, Impact test, DSC (Differential Scanning Calorimetry) and DMTA (Dynamic Mechanical Thermal Analysis). Each sample was made of SR-Ivocap resin and QC-20 resin by different processing methods. The results were as follows ; 1. As the result of the observation on the fracture surface of resin by use of SEM, sample SR-Ivocap resin cured by continuous pressure injection method showed the most homogeneous structure. This is why molecules in SR-Ivocap resin have no orientation. 2. As the result of the Impact test in order to measure the deformity, fracture energy and impact resistance of resin, the samples with QC-20 acrylic resin and SR-Ivocap resin cured by continuous pressure injection method were exellent. 3. In consequence of measuring ${\alpha}$-glass transition temperature by use of DSC on the basis of temperature change, the glass transition temperatures of sample QC-20 resin cured by pack and press method and sample SR-Ivocap resin cured by continuous pressure injection method were very similar. Thus volumetric stability could not be evaluated only by glass transition temperature. 4. In comparing volumetric stability data by DMTA, the glass transition temperature(Tg) showed $137.88^{\circ}C$ at sample QC-20 resin cured by pack and press method and $139.78^{\circ}C$ at sample SR-Ivocap resin cured by continuous pressure injection method. Therefore sample SR-Ivocap resin cured by continuous pressure injection method seems to be superior to sample QC-20 resin cured by pack and press method in the dimensional stability at high temperature. 5. In comparing storage modulus data by DMTA, the storage modulus of sample SR-Ivocap resin cured by continuous pressure injection method was higher than that of sample QC-20 resin cured by pack and press method. So. sample SR-Ivocap resin cured by continuous pressure injection method seems to be superior to sample QC-20 resin cured by pack and press method in impact strength.

  • PDF

Chemical Weathering Index of Clastic Sedimentary Rocks in Korea (국내 쇄설성 퇴적암의 화학적 풍화지수 고찰)

  • Kim, Sung-Wook;Choi, Eun-Kyoung;Kim, Jong-Woo;Kim, Tae-Hyung;Lee, Kyu-Hwan
    • The Journal of Engineering Geology
    • /
    • v.27 no.1
    • /
    • pp.67-79
    • /
    • 2017
  • Evaluation of the weathering index using the quantitative element composition of rocks is very effective in predicting the degree of weathering of rocks and the secondary weathering residuals. While the process of weathering varies according to the types of rocks, the study of weathering in Korea is concentrated on acidic igneous rocks. This study calculated the weathering indices using whole rock analysis (X-ray fluorescence analysis) of sandstone, mudstone, and shale belonging to clastic sedimentary rocks. The statistical significance of the indices was examined based on the correlation of the calculated weathering indices. Clastic sedimentary rocks showed higher significance of Wp, CIA, CIW and PIA weathering index indicating weathering of feldspar. Chemical Index of alteration (CIA) has the advantage of predicting weathering pathway and clay mineral production, but it is effective to consider chemical index of weathering index (CIW) simultaneously to improve accuracy. In order to reduce uncertainties due to carbonate rocks and to estimate the accurate weathering index, rock samples with high CaO content should be excluded from the evaluation of weathering index.

Development of a Pulse Wave Velocity Measurement System and Assessment of the System Reproducibility for the Diagnosis of Arteriosclerosis (동맥경화 진단을 위한 맥파전달속도 측정시스템 개발 및 재현성 평가)

  • Lee, Nak-B.;Im, Jae-J.;Park, Young-B.;Jeon, Young-J.
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.9 no.1
    • /
    • pp.112-124
    • /
    • 2005
  • Background: PWV is determined by dividing the distance by the time taken for the pulses traveling between two measuring sites, used as a marker of arterial stiffness and an important indicator for cardiovascular disease. Methods: A PWV measurement system, which offers a non-invasive, simple method of measurement, and simultaneous recording of six signlas(ECG, PCG and four pulse waves from carotid, femoral, radial and dorsalis pedis arteries) was developed. Seventeen healthy subjects with a mean age of 33 years(22 to 52) without any cardiovascular disease were participated for the experiment. Two observers(A and B) performed two consecutive measurements from the same subject in a random order. For the evaluation of stability and accuracy of the PWV measurement system, reproducibility of PWV from between-observer were also evaluated. Results: PWV $values(Mean{\pm}SD)$ measured by A were $7.07{\pm}1.48m/s$, $8.43{\pm}1.14m/s$ , $8.09{\pm}0.98m/s$ for aorta, arm, and leg, respectively. The values obtained from B were $6.76{\pm}1.00m/s$, $7.97{\pm}0.80m/s$, and $7.97{\pm}0.72m/s$ for aorta, arm, and leg, respectively. Between-observer $differences(mean{\pm}SEM)$ from the aorta, arm and leg were $0.14{\pm}0.15m/s$, $0.18{\pm}0.10m/s$ and $0.07{\pm}0.10m/s$. Reproducibility coefficients(2SD) from the aorta, arm, and leg were 0.62m/s, 0.84m/s and 0.86m/s. Correlation coefficients were significantly higher in aortic PWV, 0.93, compared to the coefficients for arm and leg. Coefficient of variance which reflects the reproducibility of the system ranged from $4.4{\sim}5.8%$ in all regional PWV. , Conclusion: Reproducibility of PWV in the study shows that the developed system has reliable and reproducible characteristics. The PWV measurement system used for the study offers comfortable and simple operation and provides accurate analysis and results with high reproducibility. Results of the PWV measurement system could contribute to various clinical applications in the future.

  • PDF

A Study on Clinical Findings about Vertebral Disease Diagnosed with MRI (MRI로 진단된 척추질환의 임상적 소견)

  • Kim, Ham-Gyum
    • Journal of radiological science and technology
    • /
    • v.29 no.3
    • /
    • pp.157-165
    • /
    • 2006
  • In order to analyze clinical characteristics like sex- and age-based onset frequency and onset region from vertebral disease cases, this study investigated total 1,291 cases of vertebral disease that were diagnosed via magnetic resonance imaging(MRI) from January to December 2004 at B University Hospital in metropolitan area. For higher diagnostic accuracy in cases of spinal disorder diagnosed, this study analyzed findings from data reading conducted by veteran specialists in diagnostic radiology. But this study excluded uncertain lesion cases, the cases requiring differential diagnosis from other disorders and so on from subjects under analysis. This study employed superconductive 1.5 Tesla SIGNA MR/i for MRI test and basically received resulting images via FSE(fast spin echo). In particular, this study obtained T1 and T2 myelogram with regard to regional characteristics(such as cervical vertebrae, thoracic vertebrae and lumbar vertebra) and imaging characteristics for sagittal and transverse section. As a result, this study came to the following conclusions : 1. In terms of general characteristics of subjects under analysis, male group comprised 53.5% and female 46.5% out of total 1,291 subjects. 2. The regional onset frequency of spinal disorders was converged primarily on lumbar vertebra(65.5%), which was followed by cervical vertebrae(27.3%) and thoracic vertebrae(7.0%) respectively. 3. Top 10 cases with high onset frequency of spinal disorders can be listed as follows : 1) posterior bulging disc 65.8% 2) narrowing of neural foramen 23.8% 3) herniated intervertebral disc (HIVD) 22.4% 4) spinal stenosis 16.7% 5) osteochondrosis 6.4% 6) compression fracture 6.4% 7) facet joint arthropathy 6.2% 8) spondylolisthesis 6.0% 9) spinal cord tumor 3.5% 10) inter body fusion 2.6%

  • PDF

Dietary Problems among Middle-Aged Japanese Men

  • Yoshita, Katsushi;Miura, Katsuyuki;Nishijo, Muneko;Morikawa, Yuko;Yoshiike, Nobuo;Nakagawa, Hideaki
    • Journal of Community Nutrition
    • /
    • v.5 no.2
    • /
    • pp.105-111
    • /
    • 2003
  • Balanced intake of appropriate nutrients is the key to sustaining and promoting health as well as preventing and treating diseases. It is not always easy, however, to take balanced nutrition and various related factors must be taken into consideration. This report provides a summary of studies that have examined the nutrient intakes of Japanese middle-aged men and the relationship of this intake to drinking, job-related separation from families, and health practices. The alcohol consumption of Japanese middle-aged men has more than tripled in the last forty years. When nutrient intake was examined in relation to alcohol consumption, it was discovered that the maximum acceptable alcohol consumption was approximately 23 grams (about two drinks) of pure alcohol, provided the level of nutrient intake for drinkers was equal to that of non-drinkers. The alcohol energy ratio was approximately 5%. It was also discovered that middle-aged men's eating habits deteriorate when they relocate to new posts without their families and live by themselves. Compared to those living with their families, a higher proportion of those living alone have unfavorable eating habits including skipping breakfast or lunch, having a late lunch, and eating and drinking after dinner until bedtime. When Breslow's seven health practices, nutrient intake, and consumption weight by food group were examined, it was discovered that the group that had many beneficial eating and living habits consumed plenty of legume, pulses, fruit, green yellow vegetables and milk products. Their intake of vitamins and minerals was high and the results of a physical examination proved to be excellent. According to nutrition surveys conducted in Japan, China, the United Kingdom and the United States using a 24-hour recall method with common protocols and strict controls to ensure high levels of accuracy and cross-study validity, the Japanese had the highest cholesterol intake and the lowest dietary fiber intake among the four countries. Also, the alcohol energy ratio of the Japanese exceeded 8%, the highest among the four countries, while their intake of magnesium and iron was the lowest These results indicate that it is necessary to enhance nutritional education for middle-aged men and to reinforce the social environments in which they live and work in order to promote proper diet and nutrition in Japan. (J Community Nutrition 5(2) : 105-111, 2003)