• 제목/요약/키워드: high-strength concrete high-rise building

Search Result 159, Processing Time 0.023 seconds

방화문 내부 심재로 적용하기 위한 경량기포콘크리트의 물리적 성능 검토 (A Review of the Physical Performance of Lightweight Aerated Concrete for Use as an Interior Core Material in Fire Doors )

  • 홍상훈;김봉주;정의인;김해나;박준서
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 봄 학술논문 발표대회
    • /
    • pp.111-112
    • /
    • 2023
  • With the development of cities, the density of the population is continuously increasing as buildings become larger and more high-rise, but since the Haeundae residential complex fire in Busan in 2010, there has been a growing need to meet the fire protection performance of buildings as large-scale fires continue to occur every year. On the other hand, fire doors, which are one of the fire protection performance of buildings, have been judged unqualified in 82% of cases when fire doors constructed on the actual site were inspected after completion. The reason for this is that paper honeycomb and glasswool, which are used as core materials for fire doors, absorb moisture, reducing thermal insulation performance, and sagging due to increased weight, leading to performance degradation due to warping in empty spaces. To overcome these problems, research is underway to apply lightweight aerated concrete, an inorganic material, as a core material. Therefore, in order to select a blowing agent that produces stable bubbles prior to the production of lightweight bubble concrete for application as a fire door inner core, this study examined the physical performance according to the type of blowing agent and dilution concentration, and the following conclusions were drawn. Compared to vegetable bubbles and independent bubbles, synthetic bubbles have 3~8% higher thermal conductivity than independent bubbles, but 3~6% lower slurry density than vegetable bubbles, and 2~13% higher compressive strength, which is thought to be an improvement of synthetic bubbles.

  • PDF

반복하중을 받는 콘크리트충전 각형강관 보-기둥의 거동 (Behavior of Concrete-Filled Square Tubular Beam-Column under Cyclic Load)

  • 강창훈;문태섭
    • 한국강구조학회 논문집
    • /
    • 제12권4호통권47호
    • /
    • pp.387-395
    • /
    • 2000
  • 본 연구는 콘크리트충전 각형강관(CFT) 기둥의 강도와 변형능력의 평가 및 내진성능에 대한 기초 자료의 제시를 목적으로 한다. 실험체는 초고층 건물의 최하단기둥의 응력분포를 가정하여 켄틸레버형 기둥으로 하고, 총 18개의 실험체가 일정 축력과 반복 횡하중 하에서 실험되었다. 본 실험에 적용된 주요변수는 강관의 폭/두께 비, 세장비 (LO/D), 그리고 축력비이다. 각 변수가 기둥의 강도, 변형능력, 그리고 에너지 흡수능력에 미치는 영향이 기술되었고, 각국 규준식과 실험결과를 비교하였다. 분석결과, 피복형 한국강구조학회 규준은 합성 단면적과 탄성계수를 AIJ와 AISC-LRFD 수준으로 수정한다면, 충전형에도 적용가능 할 것으로 판단된다. 마지막으로, 구속효과를 고려하여 단면의 소성해석을 통하여 구한 B. Kato의 CFT 기둥의 휨내력 제안식은 실험결과와 좋은 대응을 나타내고 있다.

  • PDF

내진 보강용 철근 사용 시 비용 절감 효과 분석을 위한 실증적 연구 (An Empirical Study for Cost Saving Effect Analysis When Using Seismic Reinforcing Bar)

  • 이종식
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제20권4호
    • /
    • pp.120-127
    • /
    • 2016
  • 철근콘크리트 구조물의 대형화, 고층화로 인해 고기능 재료의 적용이 요구되고 있다. 하지만 고장력 철근은 국내에 도입된 지 얼마되지 않고, 고장력 철근의 사용 시 철근 물량의 주상 복합 정량적으로 판단하기 위한 자료가 부족하다. 이에 본 연구는 건축 프로젝트 계획 과정에서 고장력 철근 적용 시 비용 측면의 의사 결정에서 활용할 수 있는 데이터를 제공하기 위하여, 주상 복합 건축물을 대상으로 일반 철근만 사용한 경우, 고장력 철근만을 사용한 경우, 일반 철근과 고장력 철근을 혼용한 경우 등 6가지 조건을 설정하고, 철근의 직경에 관계없이 SD400 철근만을 적용한 연구모델 1을 기준으로, 다른 연구모델의 주상 복합 주상 복합 및 공사비 변화를 분석한 결과, 연구모델 I의 주상 복합과 공사비 100%로 하였을 때, 연구모델 II는 각각 88.3%와 90.5%, 연구모델 III는 각각 80.2%와 83.4%, 연구모델 IV는 각각 91.9%와 93.5%, 연구모델 V는 각각 88.9%와 87.7%, 연구모델 VI는 각각 82.4%와 85.5%의 값을 보였다. 따라서 주상 복합과 공사비의 모두 SD600을 적용한 연구모델 III가 가장 우수한 것으로 평가되었다.

좌굴전 항복유도 장치(FLD) 개발에 관한 연구 (A Study on the Development of Force Limiting Devices(FLD) which Induce Yielding before Elastic Buckling)

  • 김철환;채원탁;오영석;김채영
    • 한국강구조학회 논문집
    • /
    • 제25권3호
    • /
    • pp.279-287
    • /
    • 2013
  • 세장한 부재에 압축력이 작용할 때, 부재는 탄성좌굴이 발생하게 되어 급격히 내하력을 상실하고 파괴에 도달하게 된다. 이러한 현상으로 인한 부재의 파괴는 종국적으로 구조체에 위해를 가하게 되어 붕괴원인이 되기도 한다. 본 연구에서는 세장한 부재에 압축력이 작용할 경우 부재가 탄성좌굴이 발생하기 이전에 항복하도록 유도하는 장치(응력제한장치)를 개발하는 것을 목적으로 하고 있다. 특히, 본 논문에서는 응력제한장치로서 면외저항판 방식을 제안하고 실험과 유한요소 해석을 수행하였다. 실험의 변수는 면외저항판의 두께 및 저항판의 경사도이다. 실험 및 해석결과 면외저항판 실험체는 항복후 소성영역에서 내력의 큰 저하없이 안정적인 거동을 나타내고 있어 응력제한방식으로서 유효성이 확인되었다.

재하시험을 통한 초고강도 선단확장 PHC말뚝의 적용성 연구 (Study on Bearing Capacity of Ultra High Strengh End Extended PHC Pile by Loading Test)

  • 황의성
    • 한국산학기술학회논문지
    • /
    • 제20권3호
    • /
    • pp.269-275
    • /
    • 2019
  • 경제 규모의 확장으로 국가 산업이 점차 발전해 나갈수록 사회 인프라를 구축하기 위한 대형 초고층 구조물의 건설이 증가함에 따라 상부의 큰하중을 하부의 암반지지층까지 안전하게 전달할 수 있는 연구가 활발히 이루어지고 있다. 본 연구에서는 우리나라의 단단한 암반층을 활용하여 지지력을 극대화 할 수 있도록 PHC의 콘크리트 압축강도를 기존 80 MPa에서 110 MPa로 높인 초고강도PHC에, 말뚝의 선단을 확장시킨 선단확장PHC를 항타공법과 매입공법으로 시공한 후 재하시험을 통해 지지력의 경향성을 확인해 보았다. 항타공법을 사용하여 선단확장PHC의 지지력을 측정해 본 결과 주면마찰력이 일반 PHC에 비해 작게 나타났으며, Stet-up 효과도 미미하게 나타나 지지력 측면에서 우위를 가질 수 없었다. 그러나 매입공법 적용시 주면마찰력의 발휘 효과는 주면부와 지반의 간격이 넓어 시멘트페이스트가 밀실히 채워질 경우 지지력 증가효과가 기대된다. 또한 초고강도PHC가 일반PHC에 비해 높은 지지력이 나타났으며, 허용항타응력도 60% 이내로 나타나 좀 더 견고한 지반까지 안전한 시공이 가능하였다. 따라서 초고강도PHC의 높아진 강도를 활용하기 위해서는 말뚝의 선단부를 연암의 강도를 지닌 지반에 설계하는 것이 말뚝 본수를 크게 절감 할 수 있으며, 시공비 절감과 공기단축의 효과도 얻을 수 있을 것이다.

Performance-based and damage assessment of SFRP retrofitted multi-storey timber buildings

  • Vahedian, Abbas;Mahini, Seyed Saeed;Glencross-Grant, Rex
    • Structural Monitoring and Maintenance
    • /
    • 제2권3호
    • /
    • pp.269-282
    • /
    • 2015
  • Civil structures should be designed with the lowest cost and longest lifetime possible and without service failure. The efficient and sustainable use of materials in building design and construction has always been at the forefront for civil engineers and environmentalists. Timber is one of the best contenders for these purposes particularly in terms of aesthetics; fire protection; strength-to-weight ratio; acoustic properties and seismic resistance. In recent years, timber has been used in commercial and taller buildings due to these significant advantages. It should be noted that, since the launch of the modern building standards and codes, a number of different structural systems have been developed to stabilise steel or concrete multistorey buildings, however, structural analysis of high-rise and multi-storey timber frame buildings subjected to lateral loads has not yet been fully understood. Additionally, timber degradation can occur as a result of biological decay of the elements and overloading that can result in structural damage. In such structures, the deficient members and joints require strengthening in order to satisfy new code requirements; determine acceptable level of safety; and avoid brittle failure following earthquake actions. This paper investigates performance assessment and damage assessment of older multi-storey timber buildings. One approach is to retrofit the beams in order to increase the ductility of the frame. Experimental studies indicate that Sprayed Fibre Reinforced Polymer (SFRP) repairing/retrofitting not only updates the integrity of the joint, but also increases its strength; stiffness; and ductility in such a way that the joint remains elastic. Non-linear finite element analysis ('pushover') is carried out to study the behaviour of the structure subjected to simulated gravity and lateral loads. A new global index is re-assessed for damage assessment of the plain and SFRP-retrofitted frames using capacity curves obtained from pushover analysis. This study shows that the proposed method is suitable for structural damage assessment of aged timber buildings. Also SFRP retrofitting can potentially improve the performance and load carrying capacity of the structure.

잠열성 결합재를 활용한 콘크리트의 특성에 관한 실험적 연구 (An Experimental Study on Properties of Concrete Using Latent Heat Binder)

  • 김용로;김도수;길배수;김욱종;이도범
    • 콘크리트학회논문집
    • /
    • 제20권5호
    • /
    • pp.661-668
    • /
    • 2008
  • 콘크리트구조물의 초고층화, 대형화 및 장대화에 따라 초고층 건축물의 매트 기초, 장대형 교량의 교각 기초, LNG 저장시설 등과 같은 수화열 관리가 반드시 필요한 대형 매스콘크리트의 적용 사례가 증가함에 따라 콘크리트의 온도균열을 효과적으로 제어할 수 있는 보다 성능 향상되고 실용적인 기술의 개발이 건설현장에서 요구되고 있다. 이에 본 연구에서는 대형 매스콘크리트의 수화열 저감을 위한 새로운 기술로서 일정 온도에서 상변화를 일으키는 잠열재를 활용하여 콘크리트 수화열 제어를 위한 잠열성 결합재를 개발하고, 이를 사용한 콘크리트의 기초물성, 내구성 및 수화발열 특성 등을 평가하였다. 연구결과 잠열성 결합재는 콘크리트의 기초물성 및 내구성에 영향을 미치지 않고, 콘크리트의 수화열 저감 및 온도균열 제어에 우수한 성능을 나타내는 것을 확인할 수 있었으며, 대형 매스콘크리트 구조물의 수화열 저감을 위한 유효한 기술로서 실용화될 수 있을 것으로 판단된다.

저층·고층 아파트가 혼합배치된 단지에서 공기단축이 건설사업비에 미치는 영향 분석 (Effects of Time Shortening on Project Cost in Housing Complex with Different Number of Layers)

  • 방종대;천영수;전명훈;김사랑;이도헌
    • 토지주택연구
    • /
    • 제3권4호
    • /
    • pp.415-421
    • /
    • 2012
  • 최근 도시 미관이 중요시 되면서 동일 아파트 건설단지 내에서 저층과 고층 아파트가 혼합배치되는 경우가 많아지고 있다. A공사에서 발주한 아파트 사업지구 중 고층 동들과 저층 동들 간의 층수 차가 4층 이상인 지구가 약 33%인 것으로 조사되었다. 일반적으로 아파트 공사의 공기는 단지 내최고층 동을 기준으로 산정한다. 이로 인해 전체 사업지구의 공사기간이 길어지고, 길어진 공기는 해당사업의 사업성에 나쁜 영향을 미친다. 그러므로 동일 단지 내 저층 고층 아파트 동들이 혼합 배치된 사업지구(이하 "혼합사업지구"라 한다)의 사업성 제고를 위해 일부 고층동 아파트의 골조공기를 단축해야 할 것이다. 그러나 혼합사업지구의 다양한 유형으로 인해 어떤 경우에는 공기단축이 사업성을 더 나쁘게 만들 수 있다. 따라서 본 연구에서는 다양한 유형을 갖고 있는 혼합사업지구의 골조공기 단축 여부를 판단할 수 있는 자료제공을 위해 혼합사업지구의 일부 고층동에 대한 골조공기 단축이 건설사업비에 미치는 영향을 분석하여 그 결과를 제시하였다.

굽힌 후 편 철근의 겹침 이음 및 기계적 이음을 갖는 벽-슬래브 접합부의 반복하중에 대한 거동 (Cyclic Behavior of Wall-Slab Joints with Lap Splices of Coldly Straightened Re-bars and with Mechanical Splices)

  • 천성철;이진곤;하태훈
    • 콘크리트학회논문집
    • /
    • 제24권3호
    • /
    • pp.275-283
    • /
    • 2012
  • 초고층 건축물의 선행 코어 후행 슬래브 접합부, 지하 연속벽과 바닥구조의 접합부, 임시 개구부 등 신구 콘크리트 접합부의 철근 이음을 위하여, 다수의 커플러를 전단키가 있는 얇은 강판에 설치한 철근 이음용 매립 강판이 최근 개발되었다. 이 공법을 사용한 접합부의 구조 성능을 검증하기 위하여, 벽체-슬래브 접합부에 대한 반복하중 실험을 실시하였다. 비교를 위해 기존에 사용되는 굽힌 철근 박스를 이용한 접합부와 이음이 없는 접합부도 함께 실험하였다. 실험 결과 철근 이음용 매립 강판을 사용한 접합부는 이음이 없는 접합부와 동일하게 [인장철근 항복]-[충분한 휨변형]-[압축 콘크리트 압괴] 후 압축 철근의 좌굴로 파괴되었다. 따라서 설계에서 가정한 충분한 연성 거동을 확인할 수 있었다. 반면, 굽힌 철근 박스를 사용한 접합부의 경우, 탄성구간에서는 철근 이음용 매립 강판과 유사하게 거동하였으나, 측면 피복 콘크리트가 빨리 탈락되었으며, 슬래브 상하부면의 겹침이음 구간에 부착 균열이 다수 발생하였다. 최종적으로 이음 없는 실험체 및 철근 이음용 매립 강판을 사용한 실험체에 비해 강도와 변형능력이 저하되었다. 또한 굽힌 후편 철근을 겹침이음한 실험체가 철근 이음용 매립 강판을 적용한 경우에 비해 강성 저하가 빠르게 진행되었다. 굽힌 후편 철근의 탄성계수는 직선 철근에 비해 낮고, 완전한 직선으로 펼 수 없기 때문에 인장력을 받으면서 일부 구간이 펴지므로 접합부의 강성을 저하시킨 것으로 판단된다. 2종류의 철근 지름(D13, D16)과 강종(SD300, SD400)에 대해, 철근이음용 매립 강판을 적용한 접합부는 공칭 강도를 충분히 상회하였다. 그러나 굽힌 후 편 철근을 사용하면 강종이 높을수록 그리고 지름이 굵을수록 휨강도가 저하되었다. 따라서 굽힌 후 편 철근의 사용에 주의가 필요하다.