• 제목/요약/키워드: high-rise reinforced concrete structure

검색결과 84건 처리시간 0.023초

압축강도 1800kg/$\textrm{cm}^2$의 초고강도콘크리트 개발에 관한 실험적 연구 (제1보 실험계획 및 예비실험) (An Experimental Study on the Manufacture Ultra-High Strength Concrete of 1800kg/$\textrm{cm}^2$ Compressive Strength (Part I The Experimental Program and Preliminary Experiment))

  • 김규용;김진만;이상수;남상일;김무한
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1994년도 가을 학술발표회 논문집
    • /
    • pp.167-170
    • /
    • 1994
  • To reduce the size of structural members, high strength concrete has recently been utilized for structure such as ultra-high-rise buildings and prestressed concrete bridges in North America, and its compressive strength has gone up to 1300kg/$\textrm{cm}^2$. In Japan, research on high-strength concrete has been undertaken on a large scale by the national enterprise so-called New RC Project. And high-strength concrete with a design compressive strength over 450kg/$\textrm{cm}^2$ has recently been employed for high rised reinforced concrete building. As a result of the serious land availability situation of metropolitan areas in the world, buildings will become taller, and even higher strengths will be required. In the future, the utilization of high-strength concrete will spread widely through the development of new structural concepts, application of steels of a higher yield stress, silica fume, and other new materials. Considering these circumstance, the aim of this experimental study is to develop ultra-high-strength concrete with compressive strength over 1800kg/$\textrm{cm}^2$ with domestic current materials. There are so many factors which influence the manufacturing of ultra-high-strength concrete. The experimental factors selected in this study are mixing methods, curing methods, water-binder ratio, maximum size of coarse by silica fume. The results of this experimental study show that it is possible to develop the ultra-high-strength concrete with compressive strength over 1700kg/$\textrm{cm}^2$ at 28days, 1800kg/$\textrm{cm}^2$ at 56 days.

  • PDF

Structural Shear Wall Systems with Metal Energy Dissipation Mechanism

  • Li, Guoqiang;Sun, Feifei;Pang, Mengde;Liu, Wenyang;Wang, Haijiang
    • 국제초고층학회논문집
    • /
    • 제5권3호
    • /
    • pp.195-203
    • /
    • 2016
  • Shear wall structures have been widely used in high-rise buildings during the past decades, mainly due to their good overall performance, large lateral stiffness, and high load-carrying capacity. However, traditional reinforced concrete wall structures are prone to brittle failure under seismic actions. In order to improve the seismic behavior of traditional shear walls, this paper presents three different metal energy-dissipation shear wall systems, including coupled shear wall with energy-dissipating steel link beams, frame with buckling-restrained steel plate shear wall structure, and coupled shear wall with buckling-restrained steel plate shear wall. Constructional details, experimental studies, and calculation analyses are also introduced in this paper.

Multi-Beams modelling for high-rise buildings subjected to static horizontal loads

  • Sgambi, Luca
    • Structural Engineering and Mechanics
    • /
    • 제75권3호
    • /
    • pp.283-294
    • /
    • 2020
  • In general, the study of a high-rise building's behaviour when subjected to a horizontal load (wind or earthquake) is carried out through numerical modelling with finite elements method. This paper proposes a new, original approach based on the use of a multi-beams model. By redistributing bending and axial stiffness of horizontal elements (beams and slabs) along vertical elements, it becomes possible to produce a system of differential equations able to represent the structural behaviour of the whole building. In this paper this approach is applied to the study of bending behaviour in a 37-storey building (Torre Pontina, Latina, Italy) with a regular reinforced concrete structure. The load considered is the wind, estimated in accordance with Italian national technical rules and regulations. To simplify the explanation of the approach, the wind load was considered uniform on the height of building with a value equal to the average value of the wind load distribution. The system of differential equations' is assessed numerically, using Matlab, and compared with the obtainable solution from a finite elements model along with the obtainable solutions via classical Euler-Bernoulli beam theory. The comparison carried out demonstrates, in the case study examined, an excellent approximation of structural behaviour.

Seismic experiment and analysis of rectangular bottom strengthened steel-concrete composite columns

  • Hui, Cun;Zhu, Yanzhi;Cao, Wanlin;Wang, Yuanqing
    • Steel and Composite Structures
    • /
    • 제20권3호
    • /
    • pp.599-621
    • /
    • 2016
  • In order to study the working mechanism of rectangular steel-concrete composite columns subjected to compression-bending load and further determine the seismic performance index, a bottom strengthened rectangular steel reinforced concrete (SRC) column with concealed steel plates and a bottom strengthened rectangular concrete filled steel tube (CFST) columns were proposed. Six column models with different configurations were tested under horizontal low cyclic loading. Based on the experiments, the load-bearing capacity, stiffness and degradation process, ductility, hysteretic energy dissipation capacity, and failure characteristics of the models were analyzed. The load-bearing capacity calculation formulas for a normal section and an oblique section of bottom strengthened rectangular steel-concrete composite columns were pesented and a finite element (FE) numerical simulation of the classical specimens was performed. The study shows that the load-bearing capacity, ductility, and seismic energy dissipation capacity of the bottom strengthened rectangular steel-concrete composite columns are significantly improved compared to the conventional rectangular steel-concrete composite columns and the results obtained from the calculation and the FE numerical simulation are in good agreement with those from the experiments. The rectangular steel-concrete composite column with bottom strengthened shows better seismic behavior and higher energy dissipation capacity under suitable constructional requirements and it can be applied to the structure design of high-rise buildings.

Evaluation of Progressive Collapse Resisting Capacity of Tall Buildings

  • Kwon, Kwangho;Park, Seromi;Kim, Jinkoo
    • 국제초고층학회논문집
    • /
    • 제1권3호
    • /
    • pp.229-235
    • /
    • 2012
  • In this paper the progressive collapse potential of building structures designed for real construction projects were evaluated based on arbitrary column removal scenario using various alternate path methods specified in the GSA guidelines. The analysis model structures are a 22-story reinforced concrete moment frames with core wall building and a 44-story interior concrete core and exterior steel diagrid structure. The progressive collapse resisting capacities of the model structures were evaluated using the linear static, nonlinear static, and nonlinear dynamic analyses. The linear static analysis results showed that progressive collapse occurred in the 22-story model structure when an interior column was removed. However the structure turned out to be safe according to the nonlinear static and dynamic analyses. Similar results were observed in the 44-story diagrid structure. Based on the analysis results, it was concluded that, compared with nonlinear analysis procedures, the linear static method is conservative in the prediction of progressive collapse resisting capacity of building structure based on arbitrary column removal scenario.

철근콘크리트 초고층 주상복합 건물의 시공 중 구조성능 분석 (Analyses of Structural Performances for RC High-Rise Residential Complex Building under Construction)

  • 황영진;김재요
    • 한국전산구조공학회논문집
    • /
    • 제28권1호
    • /
    • pp.19-27
    • /
    • 2015
  • 근래 국내 초고층 주상복합 건물에는 철근콘크리트구조가 보편적으로 적용되는데, 이러한 철근콘크리트 초고층 주상복합 건물은 시공 시점에 따라 구조적인 문제가 발생할 수 있다. 따라서, 시공 중인 철근콘크리트 초고층 주상복합 건물에 대하여, 시공 시점별 구조 안전성 및 횡력저항성능을 검토하고자 한다. 이를 위해, 예제 모델로 탑상형의 초고층 주상복합 60층 건물을 선정했고, 기존의 범용구조해석 프로그램을 사용하여 구조해석을 수행하였다. 각 시공 시점별 10층, 20층, 30층, 40층, 50층, 60층 완료모델과 60층 완공단계 모델의 구조성능을 비교하였다. 구조성능 비교를 위해 이 모델들의 고유치해석을 수행하였으며, 횡력저항성능과 부재별 단면성능을 검토하였다. 횡력저항성능 검토를 위해 횡변위비와 층간변위비를 검토했고, 부재별 단면성능 검토는 완공단계에 대한 설계강도비와 시공단계의 설계강도비를 비교하여 부재안전성을 검토하였다. 이 연구를 통해, 시공 중인 철근콘크리트 초고층 건물의 구조 안전성을 검토하고 시공단계에 적합한 구조해석 및 설계하중의 가이드라인을 제시하고자 한다.

개구부가 있는 고층 벽식 구조물의 효율적인 3차원 해석 (Efficient Three Dimensional Analysis of High-Rise Shear Wall Building with Openings)

  • 김현수;남궁계홍;이동근
    • 한국전산구조공학회논문집
    • /
    • 제15권2호
    • /
    • pp.351-365
    • /
    • 2002
  • 현재 국내에서는 벽체와 바닥판으로만 구성된 벽식 구조형식의 아파트 건물이 많이 사용되고 있다. 또한 청력에 대한 저항이 뛰어나기 때문에 전단벽 코어를 갖는 입체골조구조물이 고층 빌딩의 구조시스템으로 자주 이용된다. 기능적인 이유로 인해 이러한 구조물들의 전단벽에는 하나 또는 여러 개의 개구부가 발생하게 된다. 개구부가 있는 전단벽을 정확하게 해석하기 위해서는 여러 개의 유한요소를 사용하여 구조물을 세분모형화하는 것이 필요하다. 그러나, 전체 구조물을 유한요소로 세분하여 모형화하는 것은 막대한 해석시간과 컴퓨터 메모리를 소요하게 된다. 개구부의 수, 크기, 위치에 상관없이 적용할 수 있는 효율적인 해석기법이 본 논문에서 제안되었다. 제안된 해석기법에서는 슈퍼요소와 부분구조, 행렬응축, 가상보 등을 이용하였고 제안된 해석기법의 효율성을 검증하기 위해 벽식구조물과 전단벽 코어를 갖는 입체골조구조물의 3차원 해석이 수행되었다. 예제구조물의 해석을 통해 제안된 해석기법이 해석시간과 컴퓨터메모리를 크게 감소시키고, 정확한 해석결과를 얻을 수 있음이 확인되었다.

전단키를 갖는 프리캐스트 콘크리트 패널 수직접합부의 전단강도 (Shear Strength of Vertical Joints in Precast Concrete Panel with Shear Key)

  • 이상섭;박금성;배규웅
    • 대한건축학회논문집:구조계
    • /
    • 제35권9호
    • /
    • pp.151-158
    • /
    • 2019
  • A concrete core is used widely as lateral stability systems in high-rise modular buildings. As an alternative to traditional cast in-situ core, the precast concrete(PC) method can accelerate the construction of reinforced concrete cores. A core composed of precast elements differs from a in-situ core in having connections between the precast elements. The typical vertical connection between PC panels is consisted of shear keys, loop bars, lacer bars and grout. In this study, the effect of vertical connection components on shear strength is investigated experimentally. The test results show that the contribution to the shear strength is greater in order of grout strength, shear keys, lacer bars and loop bars. In addition, the numerical models to estimate the shear strength according to two crack patterns in the vertical joint of the PC panels are derived. The feasibility of the numerical models is evaluated by comparing the estimated shear strength and the test results.

강합성코어벽을 활용한 코너지지형 거푸집시스템 개발 (Development of Corner-Supported Auto Climbing Formwork System)

  • 홍건호;심우경
    • 대한건축학회논문집:구조계
    • /
    • 제35권7호
    • /
    • pp.171-178
    • /
    • 2019
  • Auto Climbing Formwork System (ACS) for construction of high-rise building is a construction method for automatically lifting the formwork system supported by the anchor on the pre-constructed concrete wall. It has excellent construction speed and quality, but it has the possibility of structural failure depending on the quality of concrete and also has low economical efficiency due to the use of foreign technology. In order to overcome these problems, this study conducted an optimum design for the development of a new concept of Corner Supported Auto Climbing System (CS-ACS) in conjunction with the development of corner steel-reinforced concrete core wall system. For the design the formwork system, the basic module and structural member compositions were planned, and the structural analysis program was used to analyze the optimum member's cross section and spacing. As a result, the horizontal displacement and the stress of the horizontal members were influenced by the spacing more than the cross-section of the member. On the other hand, vertical members did not affect the displacement and stress of the formwork system. The form tie was very effective in controlling the displacement when adjusting the spacing of the horizontal members, but when the spacing of the form tie is more than 1,500mm, it is analyzed that form tie is yielding in basic module. When the span of the formwork system is more than 30m, it is analyzed that the basic module needs to be changed because of the increase of overall displacement.

제진재가 삽입된 바닥 구조의 진동특성에 대한 실험연구 (Vibration Characteristics of the Floor Structures Inserted with Damping Materials)

  • 전진용;정영
    • 한국소음진동공학회논문집
    • /
    • 제16권10호
    • /
    • pp.1036-1043
    • /
    • 2006
  • Damping materials for reducing heavy-weight floor impact noise in reinforced concrete structures were tested in apartment buildings. The effect of damping materials and an impact isolator were compared with an on-site experiment conducted in a high-rise apartment building. The loss factor of damping material analyzed more than 2 times than rubber to $1.5{\sim}2.3$, could know that Damping layer has excellent attenuation performance in side of vibration reduction. The results showed that the resonance frequency increased but vibration acceleration level decreased when the damping materials were used. The heavy-weight impact sound levels of the structure decreased substantially at 63 Hz, whereas the sound levels of the structure with the impact isolator increased.