• Title/Summary/Keyword: high-frequency components

검색결과 986건 처리시간 0.026초

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

기술 준비도와 소비자 준비도가 Self Service Technology 사용동기와 태도 및 사용의도에 미치는 영향 (Effects of TR and Consumer Readiness on SST Usage Motivation, Attitude and Intention)

  • 심현숙;한상린
    • Asia Marketing Journal
    • /
    • 제14권1호
    • /
    • pp.25-51
    • /
    • 2012
  • 정보기술의 활용이 마케팅 전략의 중요한 부분으로 부각되는 시장 환경에서 본 논문에서는 패스트푸드 레스토랑에서 주문시 Self Service Technology(SST)를 사용 할 때 기술준비도와 소비자 준비도에 따른 사용동기, 태도, 사용의도의 차이를 검증하고자 하였다. Parasuraman이 TRI를 개발한 이후 SST와 TRI를 접목한 연구가 이루어져 왔지만 여전히 부족한 실정이다. 소비자 준비도 역시 SST사용에 대한 소비자의 동기와 태도 및 의도와 직접적인 영향을 미칠 수 있지만 이에 대한 연구는 이루어지지 않았다. 이에 본 연구에서는 패스트푸드 레스토랑에서 터치스크린 SST를 도입함에 있어 소비자의 기술준비도와 소비자 준비도가 Dabholkar & Bagozzi(1994)가 제안한 SST 핵심태도모델에 미치는 영향을 고찰하였다. 이때 모든 소비자와 상황적 요인에 따른 차이를 파악하고자 자아의식, 상호작용욕구, 기술에 대한 두려움 등의 소비자특성과 지각된 대기시간, 지각된 과밀 등의 상황적 요인에 따른 조절 효과를 검증하였다. AMOS 18.0프로그램을 사용하여 구조방정식 모델로 분석하였고 연구 결과 기술준비도 중 낙관성은 사용용이성과 재미 동기에 유의한 영향을 미치는 것으로 나타났다. 혁신성은 사용용이성과 성과에 유의한 영향을 미치는 것으로 나타났다. 역할의 명확성, 능력 및 자아 효능감으로 구성된 소비자준비도는 사용용이성, 성과와 재미 등 모든 SST사용동기 요소에 기술준비도보다 강하고 유의한 영향을 미치는 것으로 나타났다. 마지막으로 SST 핵심태도모델 내의 SST 사용 동기, 사용 태도 및 사용의도 간의 관계에서 소비자 특성과 상황적 요인의 조절효과를 검증한 결과 지각된 과밀을 제외한 모든 변수들이 조절효과를 지니는 것으로 나타났다. 이러한 연구 결과를 바탕으로 터치스크린 SST를 도입하려는 기업에 실무적 제언을 하였다.

  • PDF

간찰(簡札)의 안부인사(安否人事)에 대한 유형(類型) 연구(硏究) (A study on the Greeting's Types of Ganchal in Joseon Dynasty)

  • 전병용
    • 동양고전연구
    • /
    • 제57호
    • /
    • pp.467-505
    • /
    • 2014
  • 필자(筆者)는 여러 해째 간찰(簡札)를 대상으로 일련(一連)의 국어학적(國語學的) 연구(硏究)를 진행하고 있으며 이 연구(硏究)는 그 일환(一環)으로서 [안부인사(안부인사(安否人事))]의 유형화(類型化)를 위한 것이다. 이를 위하여 근대국어(近代國語) 시기(時期)(16세기(世紀)-19세기(世紀))의 한문간찰(漢文簡札)와 한글간찰(簡札)를 대상으로 [안부인사(安否人事)]를 형식적(形式的) 유형(유형(類型))와 의미적(意味的) 유형(類型)로 나누어 분석(分析)하였다. [안부인사(安否人事)]의 형식적(形式的) 유형(類型)는 정치여부(定置與否), 생략여부(省略與否), 기상여부(寄狀與否), 존비여부(尊卑與否)를 기준으로 나눌 수 있다. 정치여부(定置與否)를 제1기준으로, 생략여부(省略與否)를 제2기준으로 삼아 다섯 가지로 유형화하였다. [안부인사(安否人事)]의 전형성(典型性)이 가장 잘 드러난 정치형(定置型)이면서 완성형(完成型)을 제(第)1유형(類型)로 삼았다. 정치형(定置型)이면서 자기안부생략형(自己安否省略型)을 제(第)2유형(類型)으로, 정치형(定置型)이면서 상대안부생략형(相對安否省略型)을 제(第)3유형(類型)으로, 정치형(定置型)이면서 안부인사생략형(安否人事省略型)을 제(第)4유형(類型)로 삼았다. [안부인사(安否人事)]에서 破格이 가장 심한 도치형(倒置型)을 제(第)5유형(類型)로 삼았다. 第1유형(類型)은 [상대안부(相對安否)]가 [자기안부(自己安否)]에 선행(先行)하는 정치형(定置型)이면서 의미요소(意味要素)가 온전한 완성형(完成型)을 가리킨다. 이 유형은 [안부인사(安否人事)]의 모든 구성요소(構成要素)를 갖췄다는 점에서 가장 전형적(典型的)이며 규범적(規範的)이라 할 수 있다. 제(第)2유형(類型)은 [안부인사(安否人事)]가 [상대안부(相對安否)]로만 이루어진 것이다. 정형성(定型性)에서는 제(第)1유형(類型)보다 덜하지만 출현빈도(出現頻度)에서는 큰 차이가 없는 유형이다. [상대안부(相對安否)]를 충실히 묻되, [자기안부(自己安否)]는 생략하는 것이 예의에 크게 어긋나지 않으면서 간찰을 쉽게 쓸 수 있기 때문에 활용된다. 제(第)3유형(類型)은 [상대안부(相對安否)+자기안부(自己安否)]의 구성을 보이는 정치형(定置型)이지만 [상대안부(相對安否)]가 생략된 유형을 가리킨다. 제(第)4유형(類型)은 [상대안부(相對安否)+자기안부(自己安否)]의 구성을 보이는 정치형(定置型)이지만 [안부인사(安否人事)] 전체가 생략된 유형이다. 이 유형은 [안부인사(安否人事)]자체를 완전히 생략한 경우와 '제번(除煩)'과 같은 상투적인 표현이 [안부인사(安否人事)]를 대신하는 경우로 나뉜다. 제(第)5유형(類型)은 정치형(定置型)과 달리 [자기안부(自己安否)+상대안부(相對安否)]의 구성을 보이는 도치형(倒置型)이다. 이 유형은 정형성(定型性)에서 파격(破格)이 가장 심한 유형으로 실예(實例)도 아주 드물다. [자기안부(自己安否)]를 앞세우고 나중에 체면치레로 [상대안부(相對安否)]를 묻는 것은 예의에 어긋나기 때문이다. 이 외에 [안부인사(安否人事)] 유형을 [상대안부(相對安否)]와 [자기안부(自己安否)]가 직접 연결된 직접형(直接型)과 [事緣]으로 분리된 간접형(間接型)으로 대별(大別)하여 세분할 수도 있다. [안부인사(安否人事)]의 의미적(意味的) 유형(類型)은 기상여부(寄狀與否), 완급여부(緩急與否), 친밀여부(親密與否), 격조여부(隔阻與否)를 기준으로 나눌 수 있다. 기상(寄狀)의 경우 [안부인사(安否人事)]는 [상대안부(相對安否)(시후(時候)+문안(問安)+심경(心境))+자기안부(自己安否)(상황(狀況)+안부(安否)+심경(心境))]의 구성을 보인다. [상대안부(相對安否)]에서 [시후(時候)]는 [계절(季節)] 정보와 [기상(氣象)(날씨)] 정보로 세분(細分)할 수 있고, [심경(心境)] 또한 수신자(受信者)의 [가족안부([家族安否) 심경(心境)]과 [개인안부(個人安否) 심경(心境)]으로 나뉜다. [자기안부(自己安否)]에서 [상황(狀況)]은 수신자(受信者)의 종래 상황인 [근황(近況)]과 수신자(受信者)의 현재 상황인 [현황(現況)]으로 나뉘며 [문안(問安)] 또한 수신자(受信者)의 [가족문안(家族問安)]와 [개인문안(個人問安)]으로, [안부(安否)]는 [가족안부(家族安否)]와 [개인안부(個人安否)]로 세분(細分)할 수 있다. 이처럼 [문안(問安)]이나 [안부(安否)]가 [가족(家族)]과 [개인(個人)] 차원에서 짝을 이루어 쓰일때가 많은데 부모(父母)나 조부모(祖父母)를 모시고 사는 층층시하(層層侍下)의 대가족제도(大家族制度)에서 비롯한 현상이라 할 수 있다. 답상(答狀)의 경우 [안부인사(安否人事)]는 [상대안부(相對安否)(수신(受信)+안부(安否)+심경(心境))+자기안부(自己安否)(상황(狀況)+안부(安否)+심경(心境))]의 구성을 보며 [상대안부(相對安否)]에서만 의미구성이 기상(寄狀)과 차이가 있다. [상대안부(相對安否)]에서 [수신(受信)]은 직접 간찰을 받는 [서신(書信)]과 사람들 통해 소식을 전해 듣는 [전언(傳言)]으로 나뉘며 [안부(安否)]는 [가족안부(家族安否)]와 [개인안부(個人安否)]로, [심경(心境)] 역시 [가족안부(家族安否) 심경(心境)]과 [개인안부(個人安否) 심경(心境)]으로 나뉜다.

솔잎혹파리 피해적송림(被害赤松林)의 생태학적(生態学的) 연구(研究) (I) (Ecological Changes of Insect-damaged Pinus densiflora Stands in the Southern Temperate Forest Zone of Korea (I))

  • 임경빈;이경재;김용식
    • 한국산림과학회지
    • /
    • 제52권1호
    • /
    • pp.58-71
    • /
    • 1981
  • 충남(忠南) 전북지방(全北地方) 적송림(赤松林)의 천이과정(遷移過程)을 연구(研究)하기 위하여 솔잎혹파리의 피해지속기간(被害持續期間)에 따라 피해극기지(被害極基地) (5년전(年前)에 피해발생(被害発生))인 공주(公州)(A), 피해지속지(被害持續地)(10년전(年前)에 피해발생(被害発生))인 부여(扶餘)(B), 피해회복지(被害回復地)(20년전(年前)에 피해발생(被害発生))로서 고창지역(高敞地域)(C)을 조사지역(調査地域)으로 설정(設定)하고, 각(各) 조사지역별(調査地域別)로 환경요인(環境要因)과 식생상태(植生狀態)를 調査하여, 환경요인(環境要因)과 식생상태(植生狀態), 삼림군집(森林群集)의 비교(比較), 식물상(植物相)의 변화(変化) 등(等)을 분석(分析)한 결과(結果)를 요약(要約)하면 다음과 같다 1. 임분(林分)이 솔잎혹파리피해(被害)로 부터 회복(回復)되어 감에 따라 식생구성(植生構成)에 변화(変化)가 오고 대상수종(代償樹種)으로 발달(発達)된 참나무류(類)의 상대우점치(相対優点値)가 감소(減小)되었다. 그러나 본(本) 조사지역내(調査地域內)에서는 상수리나무의 상대우점치(相対優点値)가 다른 참나무류(類) 보다 높았다. 2. 솔잎혹파리피해(被害)가 지속(持續)됨에 따라 삼림군집(森林群集)의 종구성상태(種構成狀態)가 점차 다양(多樣)하여진다. 그후 피해(被害)가 회복(回復)됨에 따라 임분(林分)의 종구성상태(種構成狀態)는 단순화(单純化)되는 것으로 나타났다. 3. 상대밀도(相対密度) 및 상대우점치(相対優点値)의 상대치(相対値)에 의(依)한 식생천이(植生遷移)를 종합분석(綜合分析)한 결과(結果) 솔잎혹파리피해(被害)의 극심(極甚)에서 우점종(優点種)을 이루던 참나무류(類)가 피해(被害)로부터 회복(回復)되어감에 따라 그 값이 감소(減少)되고, 싸리류(類), 진달래류(類) 등(等)이 하층식생(下層植生)을 형성(形成)하는 삼림군집(森林群集)으로 변화(変化)하여 갔다. 4. 식생(植生)에 미친 토심(土深), 토양함수량(土壤含水量), 유기물함량(有機物含量), 그리고 유기물층(有機物層)의 두께는 본(本) 조사대상지(調査対象地)의 범위내에 있어서는 거의 같은 것으로 사료(思料)되었고 연평균강수량(年平均降水量)과 온도(温度)도 유사(類似)하였다고 본다.

  • PDF

재상업복무교역중적매매관계중상호신임대관계적효적영향(在商业服务交易中的买卖关系中相互信任对关系绩效的影响) (The Effect of Mutual Trust on Relational Performance in Supplier-Buyer Relationships for Business Services Transactions)

  • Noh, Jeon-Pyo
    • 마케팅과학연구
    • /
    • 제19권4호
    • /
    • pp.32-43
    • /
    • 2009
  • 信任在心理学, 经济学, 社会学中已被广泛研究, 其重要性不仅在市场营销中被强调, 在一般商业原则中也被强调. 供应商和买家之间的关系与过去不同, 过去的关系需要相当大的私人网络优势, 并可能涉及不道德的商业行为. 而在以工业营销成功的为核心的二十一世纪激烈的全球竞争中, 供应商和买家之间的关系是伙伴关系. 在相互合作的高级别信任的基础上, 通过交换的关系, 这会给买家和供应商带来长期的利益, 竞争力增强和交易成本的降低以及其他福利. 尽管现有的研究有信任的重要性, 但是在购买与供应关系中却忽视了信任的作用, 也没有系统地分析信任对关系的影响. 因此, 深入研究, 确定买家和商业服务供应商之间信任和关系绩效之间的联系是绝对需要的. 本研究中的商业服务, 包括那些支持制造业, 正作为下一代经济增长的引擎而吸引着人们的注意. 韩国政府已选择其作为制造业发展的战略领域. 由于商业服务开放市场的需求日趋激烈, 商业服务业的竞争力应该比以往得到更多的提倡. 本研究的目的是探索相互信任对买家和供应商之间的关系绩效的影响. 具体来说, 本研究在商业服务交易中提出了一个关于信任-关系绩效的理论模型, 并实证检验根据模型而提出的假设. 这项研究表明, 研究结果有战略意义. 本研究通过多种方法收集经验数据. 这些方法包括通过电话, 邮件和面试. 作为样本的公司是在韩国供应和购买商业服务的以知识为本的公司. 本研究收集的是二进的基础数据. 每个样本公司对包括购买公司及其相应的供应公司. 并跟踪调查每个公司对的相互信任. 本研究为商业服务的买卖双方提出了信任-关系绩效的模型. 该模型由信任和它的前因和后果. 买家的信任分为对供应公司的信任和对销售人员的信任. 根据Doney 和Cannon (1997)的研究我们在个人水平和组织水平上观察信任. 通常情况下, 买方是信任的受体, 但这项研究我们建议以供应商为观察受体. 因此, 它独特的关注了双边角度的知觉风险. 换言之, 供应商和买家一样, 是信任的主体, 因为交易通常是双边的. 从这个角度来看, 供应商对买家信任和买方对供货商的信赖一样重要. 供应商的信任从某种程度上受它信任的买方公司和买家的影响. 这种使用个人水平和组织水平的信任分类是根据Doney 和Cannon (1997)的研究. 信任影响供应商的选择, 这是一项双向放的工作. 供应商们积极参与供应商选择过程中, 和买家密切的一起工作. 此外, 该过程从某种程度上受每一方信任的合作伙伴的影响. 挑选过程包括一些步骤: 识别, 信息检索, 供应商选择和绩效评价. 作为这一进程的结果, 买家和供应商都进行绩效评估, 并就这些结果为基础, 采取有形或无形的纠正行动. 本研究中使用的关于信任的测量问项是根据Mayer, Davis 和 Schoorman (1995) 以及Mayer和Davis (1999)的研究发展起来的. 根据他们的建议, 有关信任的三个方面的研究包括有能力, 善和完整. 根据商业服务这个背景我们调整了原来的问题. 例如, 如 "他/她的专业能力" 已被改为 "当我们讨论我们的产品时销售人员表现出专业能力. "这项研究使用的测量问项不同于在以往的研究中使用的问项(Rotter 1967; Sullivan和Peterson 1982; Dwyer和Oh 1987. 本研究中有关信任的前因后果的测量问项是根据Doney和Cannon (1997)的研究为基础制定的. 根据商业服务这个背景我们调整了原来的问题. 特别是, 问题被设计为对买家和供应商以解决下列因素: 信誉 (诚信, 客户服务, 良好意愿), 市场地位 (公司规模, 市场份额, 在行业中的地位), 愿意定制(产品, 过程, 交付), 信息共享(专有信息, 个人信息), 愿意保持良好关系, 认为专业, 权威授权, 买方与卖方的相似性, 以及接触频率. 作为信任相应的变量, 我们对关系绩效进行了测试. 关系绩效分为有形的影响, 无形影响, 和副作用. 有形的影响包括财务业绩;无形的影响, 包括关系的改善, 网络开发, 以及内部员工的满意度;副作用包括既不是有形影响也不是无形影响的影响. 我们联系了350对公司, 105对公司答复了我们. 由于不完整我们删除了5对公司, 105对公司被用于数据分析. 用于数据分析的回应率为30%(三百五十零分之一百零五), 高于工业营销的平均回复比率. 至于回复的公司的特点, 大多数的公司运作的商业服务既为买方(85.4%)也为供应商(81.8%). 大部分买家是做消费品贸易(76%), 而供应商的大部分(70%)是做工业品贸易. 这可能意味着买家的过程是购入材料, 部件和组件从而生产消费品成品. 正如他们对他们与合作伙伴关系的长度的报告表示, 供应商比买家有更长的商业关系. 假设1测试买方-供应方特点对信任的影响. 销售人员的专业度(t=2.070, p<0.05)和权威授权(t=2.328, p<0.05)积极影响买方对供应方的信任. 另一方面, 权威授权(t=2.192, p<0.05)积极影响供应方对买方的信任. 对买方和供应方来说, 权威授权的程度对保持对彼此的信任有关键作用. 假设2测试买卖双方关系特点对信任的影响. 买家倾向于信任供应方, 因为供应方总是尽全力联系买方(t=2.212, p<0.05)这种倾向性在供应方方面也表现得很强(t=2.591, p<0.01). 另一方面, 供应商对买方的信任是由于供应商感知买家与自己的相似性(t=2.702, p<0.01). 这一发现证实了Crosby, Evans, 和Cowles(1990)的研究结果. 他们的结果表明供应方和买方通过商务或私务的定期会议来建立彼此的联系. 假设3测试信任对感知风险的影响. 结果表明无论对买方还是供应方, 信任越低, 感知风险就越大(买方: t =-6.621, p<0.01; 供应方: t=-2.437, p<0.05). 有趣的是, 这一趋势已被证明对买方更强. 这种较高水平的感知风险的一个可能的解释是在商业服务交易中买方通常比供应方感知到更大的风险. 为此, 有必要对供应商对买方实施减少风险的战略. 假设4测试信任对信息搜集. 根据结果, 对供应方和买方, 与预期相反, 信任取决于他们合作伙伴的名誉(买方t=2.929, p<0.01; 供应方t=2.711, p<0.05). 这一发现表明, 具有良好信誉的供应商往往是可信的. 以往的经验并没有显示出任何与买家或供应商信任的重要关系. 假设5测试信任对供应方/买方选择的影响. 与买方不同, 当供应方认为以往与买方的交易重要时, 供应方倾向信任买方(t=2.913 p<0.01). 但是, 本研究并没有现实资源忠诚和买方对供应方的信任之间有显著关系. 假设6测试的是信任对关系绩效的影响. 对买方和供应方, 当财务表现被报告提高时, 他们比较信任他们的合作伙伴(买方: t=2.301, p<0.05;供应方: t=3.692, p<0.01). 有趣的是, 这种趋势在供应方比较明显. 类似的, 当竞争力被报告提高时, 买卖双方比较信任他们的合作伙伴(买方t=3.563, p<0.01 ; 供应方t=3.042, p<0.01). 对供应方来说, 当对买方信任时效率和生产力会提高(t=2.673, p<0.01). 其他绩效指标与信任没有显著关系. 这项研究结果有一定的战略意义. 首先和最重要的是, 以信任为基础的交易对供应商和买家而言都是有益的. 根据研究证实, 通过努力建立和保持相互信任可以使财务表现提高. 同样, 可以通过同样的努力提高竞争力. 第二, 以信任为基础的交易能够减少购买情况中的感知风险. 这对供应商和买家都有启示. 人们普遍认为, 在一个高度参与的采购情况中买家感知到更高的风险. 为了减少风险, 以往的研究已建议供应商制定降低风险的策略. 而本研究的特点是从双边角度关注知觉风险. 换言之, 供应商也容易存在风险, 特别是当他们提供的服务, 需要非常先进的技术, 操作和维护. 因此, 购买者和供应商必须一起密切合作解决问题. 因此, 相互信任在问题解决过程中起着关键作用. 第三, 在这项研究中发现, 销售人员有更多的授权, 他或她越被信任. 这一发现从战术角度看是非常重要的. 建立信任是一个长期的任务, 然而, 当互信尚未开发, 供应商能够通过授权销售人员做出某些决定来克服遇到的问题, 这一结论也适用于供应商.

  • PDF