• Title/Summary/Keyword: high waves

Search Result 1,499, Processing Time 0.035 seconds

Extraction of Muscle Areas from Ultrasonographic Images using Information of Fascia (근막 정보를 이용한 초음파 영상에서의 근육 영역 추출)

  • Kim, Kwang-Baek
    • Journal of Korea Multimedia Society
    • /
    • v.11 no.9
    • /
    • pp.1296-1301
    • /
    • 2008
  • Ultrasonography constructs pictures of areas inside the body needs in diagnosis by bouncing high-enorgy sound waves(ultrasound) off internal tissues or organs. In constructing an ultrasonographic image, the weakness of bounding signals induces noises and detailed differences of brightness, so that having a difficulty in detecting and diagnosing with the naked eyes in the analysis of ultrasonogram. Especially, the difficulty is extended when diagnosing muscle areas by using ultrasonographic images in the musculoskeletal test. In this paper, we propose a novel image processing method that computationally extracts a muscle area from an ultrasonographic image to assist in diagnosis. An ultrasonographic image consists of areas corresponding to various tissues and internal organs. The proposed method, based on features of intensity distribution, morphology and size of each area, extracts areas of the fascia, the subcutaneous fat and other internal organs, and then extracts a muscle area enclosed by areas of the fascia. In the extraction of areas of the fascia, a series of image processing methods such as histogram stretching, multiple operation, binarization and area connection by labeling is applied. A muscle area is extracted by using features on relative position and morphology of areas for the fascia and muscle areas. The performance evaluation using real ultrasonographic images and specialists' analysis show that the proposed method is able to extract target areas being approximate to real muscle areas.

  • PDF

Adhesion Characteristics of Polymers and Ceramic Surface Coated on Metal by Plasma Spray (플라즈마 용사법에 의한 금속면에 세라믹 코팅된 표면과 범용고분자와의 접착특성)

  • Lee, Gyeong-Hui;Gwon, Sun-Hun;Jo, Won-Je;Ha, Chang-Sik
    • Korean Journal of Materials Research
    • /
    • v.9 no.7
    • /
    • pp.724-734
    • /
    • 1999
  • The adhesion characteristics of the thermoplastic resins such as PE, PP PVC, PET and PS were investigated on the surfaces of conventional steel (SS41), steel (SS41P) treated with ultrasonic waves and the SS41P coated with several ceramic powders (SS41PC) by the plasma spray. Alumina (Al$_2$O$_3$), alumina titania (Al$_2$O$_3$95%, TiO$_2$ 5%) and zirconia yttria (ZrO$_2$ 95%, $Y_2$O$_3$5% ) were used for the materials plasma spray The morphologies, surface hardness, surface roughness, and contact angles on SS41, SS41P, and SS41PC were examined. The tensile shear strength and peel strength of the polymers which were attached to the surfaces of ceramics coated on SS41P also were measured. The tensile shear strength and peel strength of polymers adhered to ceramic surface coated on steel were found to be stronger than those of conventional steel. The tensile shear strength and peel strength of the polymers adhered on the surfaces of ceramics coated steel increased in the following order PE > PET > PP > PS > PVC. The high adhesion strength of PE may be attributed to the surface roughness and its anchor effect on the ceramic surface.

  • PDF

Basic Research on Lighting Design for Learning Effect (학습효과 증진을 위한 조명설계에 대한 기초연구)

  • Lee, Boong-Joo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.4
    • /
    • pp.518-524
    • /
    • 2020
  • This study conducted basic research on an LED lighting design to improve the learning effect from brain wave analysis. The ideal environments of mathematics, language, and creative region can be different. Inside the space where the lighting environment can be experienced directly, the test subject consisted of common elements. Other lighting was blocked completely in controlled lighting conditions. The brain waves were analyzed according to the change in color temperature and illumination. The analyzer used was fabricated by EMOTIV Company. In the variable RGB LED light, the color of the light was measured, and the brain wave of each subject was determined. LED lights have variable color temperature (3000 [K], 4500 [K]. 250 [lux], 70% -350 [lux], 100% -500 [lux]). As research results, the highest concentration in a mathematics study was in the general condition of a high color temperature, in which the optimal condition was a 6000[K] color temperature and 350[lux] illumination. The optimal condition for a language study was a 4500[K] color temperature and 500[lux] illumination, and that of the creative study was 3000[K] color temperature and 500[lux] illumination. Overall, the possibility of emotional ability and concentrated learning efficiency can be improved by the LED lighting design with the color temperature and illumination.

ECG Signal Compression based on Adaptive Multi-level Code (적응적 멀티 레벨 코드 기반의 심전도 신호 압축)

  • Kim, Jungjoon
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.23 no.6
    • /
    • pp.519-526
    • /
    • 2013
  • ECG signal has the feature that is repeated in a cycle of P, Q, R, S, and T waves and is sampled at a high sampling frequency in general. By using the feature of periodic ECG signals, maximizing compression efficiency while minimizing the loss of important information for diagnosis is required. However, the periodic characteristics of such amplitude and period is not constant by measuring time and patients. Even though measured at the same time, the patient's characteristics display different periodic intervals. In this paper, an adaptive multi-level coding is provided by coding adaptively the dominant and non-dominant signal interval of the ECG signal. The proposed method can maximize the compression efficiency by using a multi-level code that applies different compression ratios considering information loss associated with the dominant signal intervals and non-dominant signal intervals. For the case of long time measurement, this method has a merit of maximizing compression ratio compared with existing compression methods that do not use the periodicity of the ECG signal and for the lossless compression coding of non-dominant signal intervals, the method has an advantage that can be stored without loss of information. The effectiveness of the ECG signal compression is proved throughout the experiment on ECG signal of MIT-BIH arrhythmia database.

Dispersion Characteristics of Wave Forces on Interlocking Caisson Breakwaters by Cross Cables (크로스 케이블로 결속된 인터로킹 케이슨 방파제의 파력분산특성)

  • Seo, Ji Hye;Yi, Jin Hak;Park, Woo Sun;Won, Deck Hee
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.27 no.5
    • /
    • pp.315-323
    • /
    • 2015
  • Damage level of coastal structures has been scaled up according to increase of wave height and duration of the storm due to the abnormal global climate change. So, the design criteria for new breakwaters is being intensified and structural strengthening is also conducted for the existing breakwaters. Recently, interlocking concept has been much attention to enhance the structural stability of the conventional caisson structure designed individually to resist waves. The interlocking caisson breakwater may be survival even if unusual high wave occurs because the maximum wave force may be reduced by phase lags among the wave forces acting on each caisson. In this study, the dispersion characteristics of wave forces using interlocking system that connect the upper part of caisson with cable in the normal direction of breakwater was investigated. A simplified linear model was developed for computational efficiency, in which the foundation and connection cables were modelled as linear springs, and caisson structures were assumed to be rigid. From numerical experiments, it can be found that the higher wave forces are transmitted through the cable as the angle of incident wave is larger, and the larger the stiffness of the interlocking cable makes larger wave dispersion effect.

A Simulation of Wave Induced Current Around the Jeju New Harbor (제주외항 건설에 따른 주변 해역의 해빈류 변화 예측)

  • Kwak, Moon-Su;Pyun, Chong-Kun
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.4 no.3 s.14
    • /
    • pp.1-8
    • /
    • 2004
  • In this study, the change of the current in the coastal zone before and after the construction of Jeju new harbor was predicted by using the numerical model, which uses Hardy-Cross method. The numerical model was carried out for the present state, before the construction, and the state after the construction, and for the wave direction the NNW direction for winter and NE direction for summer were tested so that the seasonal change may be considered. The computation result shows that a large amount of the wave induced current was occurred when there were high waves coming in from NNW direction before and after the construction. Also, before the construction a longshore current occurred moving from the west to the east at the new harbor construction site so that it formed a rip current in the Hwabuk-dong front sea. And also, after the construction, the tip current produced changed into nearshore circulating current and a small circulating current appeared at the harbor entrance. On the other hand, at Samyang 4each, which is 3.0km away from the new harbor in the NE direction, shows that there was a longshore current occurred from the west to the east, which is in the opposite direction the new harbor, and the effect on the new harbor by sediment transport at Samyang beach is thought to be very small.

Evidence for Adenosine Triphosphate (ATP) as an Excitatory Neurotransmitter in Guinea-Pig Gastric Antrum

  • Kang, Tong-Mook;Xu, Wenxie;Kim, Sung-Joon;Ahn, Seung-Cheol;Kim, Young-Chul;So, In-Suk;Park, Myoung-Kyu;Uhm, Dae-Yong;Kim, Ki-Whan
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.3 no.2
    • /
    • pp.165-174
    • /
    • 1999
  • We explore the question of whether adenosine 5'-triphosphate (ATP) acts as an excitatory neurotransmitter in guinea-pig gastric smooth muscle. In an organ bath system, isometric force of the circular smooth muscle of guinea-pig gastric antrum was measured in the presence of atropine and guanethidine. Under electrical field stimulation (EFS) at high frequencies (>20 Hz), NO-mediated relaxation during EFS was followed by a strong contraction after the cessation of EFS (a 'rebound-contraction'). Exogenous ATP mimicked the rebound-contraction. A known $P_{2Y}-purinoceptor$ antagonist, reactive blue 2 (RB-2), blocked the rebound-contraction while selective desensitization of $P_{2Y}-purinoceptor$ with ${\alpha},{\beta}-MeATP$ did not affect it. ATP and 2-MeSATP induced smooth muscle contraction, which was effectively blocked by RB-2 and suramin, a nonselective $P_2-purinoceptor$ antagonist. Particularly, in the presence of RB-2, exogenous ATP and 2-MeSATP inhibited spontaneous phasic contractions, suggesting the existence of different populations of purinoceptors. Both the rebound-contraction and the agonist-induced contraction were not inhibited by indomethacin. The rank orders of agonists' potency were 2-MeSATP > ATP ${ge}$ UTP for contraction and ${\alpha},{\beta}-MeATP\;{\ge}\;{\beta},{\gamma}-MeATP$ for inhibition of the phasic contraction, that accord with the commonly accepted rank order of the classical $P_{2Y}-purinoceptor$ subtypes. Electrical activities of smooth muscles were only slightly influenced by ATP and 2-MeSATP, whereas ${\alpha},{\beta}-MeATP$ attenuated slow waves with membrane hyperpolarization. From the above results, it is suggested that ATP acts as an excitatory neurotransmitter, which mediates the rebound-contraction via $P_{2Y}-purinoceptor$ in guinea-pig gastric antrum.

  • PDF

Study on Reliability of Interpretation and Reproducibility of a Pulse Analyser (맥진기 판독의 신뢰도 및 파형의 재현성 연구)

  • Park, Seung-Chan;Lee, Ji-Hye;Lee, Hye-Yoon;Cho, Min-Kyoung;Kim, Do-Hyung;Kim, So-Yeon;Choi, Jun-Yong;Han, Chang-Woo;Park, Seong-Ha;Hong, Jin-Woo;Lee, In;Kwon, Jung-Nam
    • The Journal of Internal Korean Medicine
    • /
    • v.34 no.3
    • /
    • pp.231-239
    • /
    • 2013
  • Objectives : This study was performed to evaluate inter-rater and intra-rater reliability of interpretation and reproducibility of a pulse analyser (MAXMAC27-Plus). Methods : 38 of 40 volunteers completed the pulse analysis consecutively. Three Korean medical doctors who had at least 2 years of clinical experience interpreted the pulse waves for 3 aspects of size, depth and shape, then inter-rater reliability and crude agreement was obtained. Reinterpretation was done 2 weeks later and intra-rater reliability and crude agreement was obtained. Intra-rater reliability and crude agreement between 1st and 2nd measurement was calculated. Cohen's weighted kappa for size, Cohen's kappa for depth and shape were used as statistical analysis. Results : Inter-rater reliability of size, depth and shape among 3 raters was 0.598, 0.604, and 0.312, respectively, showing moderate to substantial agreement. Average intra-rater reliability between 1st and 2nd interpretation of size, depth and shape was 0.806, 0.705, and 0.638, respectively, showing substantial to almost perfect agreement. However, intra-rater reliability between consecutive measurements of size, depth and shape was 0.221, 0.121, and 0.194, respectively, which showed only poor to fair agreement. Conclusions : Intra-rater and inter-rater reliability of one pulse wave showed relatively high concordance. Training by a clinical expert may effect better concordance among raters. Test-retest reliability showed poor agreement. Improvement of measurement technique and device performance will be needed.

Detection of a Surface-Breaking Crack Using the Surface Wave of a Laser Ultrasound (레이저 초음파의 표면파를 이용한 표면결함 측정)

  • Park, Seung-Kyu;Jung, Hyun-Kyu;Baik, Sung-Hoon;Lim, Chang-Hwan;Joo, Young-Sang;Kang, Young-June
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.26 no.2
    • /
    • pp.84-89
    • /
    • 2006
  • A laser ultrasonic inspection system is a non-contact inspection device which generates and measures ultrasounds by using laser beams. A laser ultrasonic inspection system provides a high measurement resolution because the ultrasonic signal generated by a pulse laser beam has a wide-band spectrum and the ultrasonic signal is measured from a small focused spot of a measuring laser beam. In this paper, we have investigated the detection techniques of a surface-breaking crack by using the laser ultrasonic surface waves. A crack acts as a low pass filter whose cut-off frequency is lowered in proportion to the depth of a crack. And, the center frequency value of a spectrum is decreased in proportion to the depth of a crack. In this paper, we extracted the crack information by using the frequency attenuation from the normalized transfer function spectrum of a surface-breaking crack. Also, we effectively measured the crack depth by using the decreasing value of the center frequency from a crack passed ultrasonic signal. The proposed measuring techniques of crack depths provided more precise information than the amplitude measuring technique.

A Novel Approach for Controlling Process Uniformity with a Large Area VHF Source for Solar Applications

  • Tanaka, T.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.146-147
    • /
    • 2011
  • Processing a large area substrate for liquid crystal display (LCD) or solar panel applications in a capacitively coupled plasma (CCP) reactor is becoming increasingly challenging because of the size of the substrate size is no longer negligible compared to the wavelength of the applied radio frequency (RF) power. The situation is even worse when the driving frequency is increased to the Very High Frequency (VHF) range. When the substrate size is still smaller than 1/8 of the wavelength, one can obtain reasonably uniform process results by utilizing with methods such as tailoring the precursor gas distribution by adjustingthrough shower head hole distribution or hole size modification, locally adjusting the distance between the substrate and the electrode, and shaping shower head holes to modulate the hollow cathode effect modifying theand plasma density distribution by shaping shower head holes to adjust the follow cathode effect. At higher frequencies, such as 40 MHz for Gen 8.5 (2.2 m${\times}$2.6 m substrate), these methods are not effective, because the substrate is large enough that first node of the standing wave appears within the substrate. In such a case, the plasma discharge cannot be sustained at the node and results in an extremely non-uniform process. At Applied Materials, we have studied several methods of modifying the standing wave pattern to adjusting improve process non-uniformity for a Gen 8.5 size CCP reactor operating in the VHF range. First, we used magnetic materials (ferrite) to modify wave propagation. We placed ferrite blocks along two opposing edges of the powered electrode. This changes the boundary condition for electro-magnetic waves, and as a result, the standing wave pattern is significantly stretched towards the ferrite lined edges. In conjunction with a phase modulation technique, we have seen improvement in process uniformity. Another method involves feeding 40 MHz from four feed points near the four corners of the electrode. The phase between each feed points are dynamically adjusted to modify the resulting interference pattern, which in turn modulate the plasma distribution in time and affect the process uniformity. We achieved process uniformity of <20% with this method. A third method involves using two frequencies. In this case 40 MHz is used in a supplementary manner to improve the performance of 13 MHz process. Even at 13 MHz, the RF electric field falls off around the corners and edges on a Gen 8.5 substrate. Although, the conventional methods mentioned above improve the uniformity, they have limitations, and they cannot compensate especially as the applied power is increased, which causes the wavelength becomes shorter. 40 MHz is used to overcome such limitations. 13 MHz is applied at the center, and 40 MHz at the four corners. By modulating the interference between the signals from the four feed points, we found that 40 MHz power is preferentially channeled towards the edges and corners. We will discuss an innovative method of controlling 40 MHz to achieve this effect.

  • PDF