• 제목/요약/키워드: high voltage cable

검색결과 339건 처리시간 0.029초

초전도 케이블의 퀜치 특성에 대한 계통안전성 제어방식 (Power System Security Control Method for Quench Characteristic of High-Temperature Superconducting Cable)

  • 이근준;황시돌;이정필;김창현;박희철
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 학술대회 논문집
    • /
    • pp.375-380
    • /
    • 2004
  • This paper presents the basic quench protection idea for the HTS(High-Temperature Superconducting) cable. In Korea power system, the transfer capability of transmission line is limited by the voltage stability, and HTS cable could be one of the countermeasure to solve the transfer limit as its higher current capacity and lower impedance[1]. However, the quench characteristic of HTS cable makes HTS cable to loss its superconductivity, and therefore change the impedance of the line and power system operating condition dramatically. This pheonominum threats not only HTS cable safety but also power system security, therefore a proper protection scheme and security control counterplan have to be established before HTS cable implementation. In this paper, the quench characteristics of HTS cable for the fault current based on heat balance equation was established and a proper protection method by FCL(Fault Current Limiter) was suggested.

  • PDF

초고압 CABLE 감시시스템 연구 (Surveillance System For Extra High Voltage Cable)

  • 한기만;이광철;전승익;김충식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 B
    • /
    • pp.789-793
    • /
    • 1992
  • For improving the power supply reliability and minimizing maintenance work of E.H.V. underground transmission line, new surveillance systems are strongly desired for use in the field of electric power transmission. For underground installation, high system reliability is required because E.H.V. cables, if an accident happen, can have a serious impact on social activities and human life. In answer to this requirement, applications of optical fiber transmission system have been widely developed in a variety of field. The main function of this system are cable fault location, oil leak detection, and surveillance of the cable circuit and tunnel condition.

  • PDF

Mini-model 초전도 케이블의 유전손실 특성 (The Dielectric loss Properties of Mini-model Superconducting Cable)

  • 김영석;곽동순;한철수;김해종;김동욱;김상현
    • 한국전기전자재료학회논문지
    • /
    • 제16권10호
    • /
    • pp.946-951
    • /
    • 2003
  • A high-Tc superconducting cable(HTS cable) is expected as an underground power line supplying the electrical power the densely populated city in future. The electrical insulation is very important for develop HTS cable system because it is operated a high voltage and in cryogenic temperature. We manufactured a mini-model cable and measured a tan$\delta$ of cable using schering bridge. The tan$\delta$ of PPLP was lower than that of Tyvek and Kraft at a given temperature, the tan$\delta$ of PPLP was 1.16${\times}$10-3. According to the increase of electric stress the tan$\delta$ increased because partial discharge occurred inside butt gap of mini-model cable. However, the tan$\delta$ decreased by increase of liquid nitrogen pressure. This reason is thought by decrease of part discharge between butt gap by increase of liquid nitrogen pressure.

축소형 초전도 직류 케이블 시스템의 제작 및 시험 (Fabrication and test of a miniaturized superconducting DC cable system)

  • 김진근;김성규;박민원;유인근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.794-795
    • /
    • 2011
  • The DC side voltage and current of a HVDC transmission system are directly affected by non-linear switching devices such as the thyristor valve which causes real power losses, even under the superconducting conditions of a high temperature superconducting (HTS) power cable. This paper deals with the development of miniaturized superconducting DC cable system. The authors designed and fabricated two thyristor converters for DC transmission system. One is operated as a rectifier and the other is an inverter. The HTS model cable was connected between the DC side of the rectifier and inverter. Real DC transport current and voltage were applied to the miniaturized HTS DC cable. Experimental results are discussed in detail.

  • PDF

Epoxy 절연물의 내크랙성 향상에 관한 연구 (Study on Crack Resistance Improvement of Epoxy Insulation)

  • 하영길;김수연;이상진;김영성;박완기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 D
    • /
    • pp.1581-1583
    • /
    • 1999
  • Epoxy Compound has been used as insulation material in cable accessories. During the applying voltage to cable, heat shock is induced to accessory by the temperature difference between atmosphere and conductor. In this study, crack resistance, thermal and mechanical properties were evaluated about conventional epoxy compound and rubber toughened epoxy compound. Because rubber absorbs the stress caused by heat shock, crack resistance of rubber toughened epoxy compound is high. In the case of low thermal expansion coefficient, the compound shows high crack resistance because of low volumetric change.

  • PDF

Electrical Insulation Design of a 154kV-Class HTS Power Cable

  • Choi, Jin-Wook;Kwag, Dong-Soon;Choi, Jae-Hyeong;Kim, Hae-Jong;Cho, Jeon-Wook;Kim, Sang-Hyun
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제11권2호
    • /
    • pp.25-28
    • /
    • 2009
  • A 154kV class high-temperature superconducting (HTS) power cable system is developing in Korea. For insulation design of this cable, it is important that study on cryogenic electrical insulation design to develop the cold dielectric type HTS cable because the cable is operated under the high voltage environment in cryogenic temperature. Therefore, this paper describes a design method for the electrical insulation layer of the cold dielectric type HTS cable adopting the partial discharge-free design under ac stress, based on the experimental results such a ac breakdown strength, partial discharge inception stress, $V_{ac}$-t characteristics, $V_{imp}$-n characteristics, and impulse breakdown strength of liquid nitrogen/laminated polypropylene paper (LPP) composite insulation system in which the mini-model cable is immersed into pressurized liquid nitrogen.

발전소에서 활선 고전력 케이블의 운전 부하전류에 따른 도체 및 피복표면의 온도 분석 (Examination of Conductor and Sheath Temperatures Dependent on the Load Currents through High-Power Live Cables at a Power Station)

  • 엄기홍
    • 한국인터넷방송통신학회논문지
    • /
    • 제17권1호
    • /
    • pp.213-218
    • /
    • 2017
  • 발전소에서 전기를 생산 및 공급하기 위하여 고전압 전력 시스템이 동작하고 있다. 고전압 시스템은 저전압 시스템과 비교하여 구조가 복잡하고, 규모가 크고, 가격이 비쌀 뿐만 아니라. 사고 발생시 저압 시스템을 포함하는 대부분의 설비들에 정전사고가 발생하여 막대한 경제적 손실을 초래한다. 설계부터 시공 및 관리를 더욱 철저히 해야 한다. 설치환경 및 사용 조건 부하량 등에 따라 차이가 있겠지만, 증설과정, 부적절한 설계 등으로 인하여 케이블의 단면적이 부족할 경우가 발생하며, 운전 전류에 의하여 초과된 허용온도는 케이블의 열화 상태를 초래한다. 우리는 케이블의 사고를 체계적으로 감시 및 예방하기 위한 측정 장비를 개발, 한국서부발전 주식회사(Korean Western Power Co. Ltd.)에 설치하여 활선 케이블을 진단하였다. 이 논문에서 우리는 케이블의 부하전류를 측정하고, 측정된 부하전류에 의한 온도 특성을 예측 연구한 결과를 제시한다. 이 온도 값을 해석하여 케이블의 열화에 미치는 영향을 예측할 수 있다.

인버터 스위칭전압 파형에 의한 전동기 권선 영향 해석 (Analysis of Motor Winding impact by inverter Switching Voltage Waveforms)

  • 김종겸
    • 조명전기설비학회논문지
    • /
    • 제13권1호
    • /
    • pp.94-101
    • /
    • 1999
  • 본 논문은 PWM인버터 장치의 스위칭 서지에 관한 문제를 분석한 것이다. 교류 전동기의 효율적인 속도제어를 위한 가변속 구동 장치의 적용이 증가함에 따라 전동기와 가변속 구동장치에 관련된 고장이 발생한다. 산업용 전동기 설비에 PWM 드라이브의 도입은 때때로 높은 과도전압 피크에 의한 상권선 사이 절연파괴를 낳을 수 있다. 높은 스위칭 주파수와 결합한 전동기 케이블 길이는 적?한 드라이브 동작을 위한 매우 민감한 문제가 된다. 케이블 길이와 높은 스위칭주파수의 결과는 전동기와 인버터에 영향을 미칠 수 있다. 전동기 권선 절연레벨이 낮을 때, 높은 피크전압과 빠른 전압상승시간에 의해 생겨난 고장 확률은 높다. 전압반사는 전동기 용량, 여러 가변속 구동장치와 상승시간에 대해 계산하였으며 이를 도식적으로 나타내었다. 인버터 구동 교류 전동기 시스템에서 전동기 단자 과전압과 전압상승률을 줄이기 위한 필터효과도 언급하였다. 연구결과 전동기 용량과 전동기 절연정격 레벨이 낮을수록 그리고 스위칭 시간과 케이블 길이가 짧을수록 절연파괴의 가능성이 높아짐을 알 수 있었다.

  • PDF

도장 오염이 Electric Cable의 성능에 미치는 영향 연구 (A Study on Effect of Coating Stain on the Performance of Electric Cable)

  • 조연호;이상혁;손영석
    • 대한조선학회 특별논문집
    • /
    • 대한조선학회 2009년도 특별논문집
    • /
    • pp.18-23
    • /
    • 2009
  • After the installation of electric cables at block, PE(pre-erection) and hull stages, the coating stains on the electric cable sheath were unavoidably occurred by additional painting process. According to class rules paint or coating applied on the electric cables shall not adversely affect the mechanical, chemical of fire resistant characteristics of the electric cable sheath. However, there has not been quantitatively studied about the effect of coating stains on properties of sheath materials. In this study, we tried to investigate the effect of coating stains on the performance and deterioration of sheath materials by using FTIR, SEM analysis, flame retardant, high potential voltage and tensile test. The results sowed that coating stains, which were occurred during painting work on site could not adversely affect on the performance and deterioration of sheath materials.

  • PDF

Computations of Losses and Temperatures in the Core Ends of a High Voltage Turbo-generator

  • Liu Yujing;Hjarne Stig
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제5B권4호
    • /
    • pp.299-305
    • /
    • 2005
  • The work described in this paper is to investigate the additional iron losses and consequent temperatures in core ends of a turbo-generator wound with high voltage cables. Electromagnetic calculations are made with 3D FE models, which include the lamination material with anisotropic properties both in magnetic permeability and electric conductivity. The models also include the geometry of the stator teeth and eventually the axial steps designated to reduce the core end losses. The 3D model of the rotor consists of field windings with straight in-slot parts and end windings. The thermal models are simplified into two dimensions and include the heat sources dumped from the 3D electromagnetic solutions. The influences of power factor on additional iron losses are studied for this cable wound machine and conventional machines. The calculation results show that the additional iron losses can be reduced to about $15\%$ by introducing some small steps around the airgap corner of core ends.