• 제목/요약/키워드: high temperature water

검색결과 4,451건 처리시간 0.033초

필라멘트 와인딩 복합적층재의 환경가속 노화시험 평가 (Degradation Characteristics of Filament-Winding-Laminated Composites Under Accelerated Environmental Test)

  • 김덕재;윤영주;최낙삼
    • 대한기계학회논문집A
    • /
    • 제31권3호
    • /
    • pp.295-303
    • /
    • 2007
  • Degradation behaviors of filament-winded composites have been evaluated under the accelerated environmental test of high temperature, water immersion and thermal impact conditions. Two kinds of laminated composites coated by an urethane resin have been used: carbon-fiber reinforced epoxy(T700/Epon-826, CFRP) and glass-fiber reinforced phenolic (E-glass/phenolic, GFRP). For tensile strength of $0^{\circ}$ composites, CFRP showed little degradation while GFRP did high reduction by 25% under the influence of high temperature and water However for water-immersed $90^{\circ}$ composites tensile strength of both CFRP and GFRP showed high reduction. Bending strength and modulus of $90^{\circ}$ composites were largely reduced in water-immersion as well as high temperature environment. Urethane coating on the composite surface improved the bending properties by 20%, however hardly showed such improvement for water-immersed $90^{\circ}$ composites. In case of shear strength and modulus, both CFRP and GFRP showed high reduction by water-Immersion test but did a slight increase by high temperature and thermal impact conditions.

건대추의 등온흡습곡선 및 품질열화특성 (Moisture Sorption Isotherm and Quality Deterioration of Dry Jujube)

  • 김영숙;안덕순
    • 한국식품저장유통학회지
    • /
    • 제4권1호
    • /
    • pp.33-38
    • /
    • 1997
  • In order to provide informations for designing packaging and storage condition of dry jujube (Zizyphus jujuba MILLER), moisture sorption isotherm was determined for temperatures of 20, 30 and 4$0^{\circ}C$, and quality changes were evaluated as function of temperature and water activity. Dry jujube at a given water activity showed higher equilibrium moisture content for lower temperature. Moisture isothem could be fitted by GAB model equation, giving higher C value, lower m0 and relatively constant k value with increase in temperature. Ascorbic acid was lost more highly at higher temperature and water activity, and showed negligible retention for whole range of water activity and temperature studied after 141 days. Browning increased with water activity up to 0.73 at 30 and 4$0^{\circ}C$. Dry jujube of high water activity had high L value in surface color, which represent brightness of surface color. Considering quality retention in the storage, dry jujube is desired to be dried to water activity of 0.42 and be stored at temperature below 3$0^{\circ}C$

  • PDF

Frictional Characteristics of Stainless Steel Ball Bearings Lubricated with Hot Water

  • Lee, Jae-Seon;Kim, Jong-In;Kim, Ji-Ho;Park, Hong-Yune;Zee, Sung-Qunn
    • KSTLE International Journal
    • /
    • 제4권2호
    • /
    • pp.43-46
    • /
    • 2003
  • Water-lubricated frictional characteristics of a stainless steel ball bearings are not well known compared to the oil-lubricated frictional characteristics. Furthermore a study on friction at a high temperature is rare because the bearing maintenance strategy for water-lubricated or chemicals-lubricated bearings of equipment is generally based on the replacement of the failed bearings-and parts. Ball bearings and ball screw are installed in the power transmission for the newly developing integral reactor and these are lubricated with chemically-controlled pure water at a high temperature and a high pressure. Bearings and power transmitting mechanical elements for an atomic reactor requires high reliability and high performance during the estimated lifetime, and it should be verified. In this paper, experimental research results of the frictional characteristics for water-lubricated ball bearings are presented as a preliminary investigation.

중온 지열수를 이용한 고온제조 열펌프 시스템 해석 및 설계 (Design of a High Temperature Production Heat Pump System Using Geothermal Water at Moderate Temperature)

  • 김민성;백영진;박성룡;장기창;이영수;나호상
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 춘계학술대회 논문집
    • /
    • pp.638-641
    • /
    • 2008
  • Geothermal water at moderate temperature in a range between 30 to $50^{\circ}C$ exists sparse in surroundings. Mostly they are utilized as heat or water source at spar zones in Korea. However, a large portion of used water is discarded due to its poor recovery quality and inferior application technologies. In this research, an innovative heat pump system based on the hybrid concept that combinate compression cycle and absorption cycle was investigated mathematically. The hybrid heat pump aims to recycle various kind of the heat sources at moderate temperature including geothermal water effectively. The prime objective of the simulation is to design a compression/absorption hybrid heat pump system which can make high temperature above the level of $90^{\circ}C$ and low temperature of $20^{\circ}C$ as well at the same using $50^{\circ}C$ geothermal heat water. As a result, primitive data was provided as a basis to design a prototype 3 RT class hybrid heat pump.

  • PDF

고온/고압 하에서 물로 윤활되는 스테인레스 강의 마찰 특성 (Frictional characteristics of stainless steel lubricated with pressurized high temperature water)

  • 이재선;김은현;김지호;김종인
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2001년도 제33회 춘계학술대회 개최
    • /
    • pp.96-99
    • /
    • 2001
  • The fatigue life of support bearings is one of the most critical factors for the performance of a control rod driving mechanism. They are operated at high temperature and high pressure and especially lubricated with dramatically low viscosity water. The support bearing is made of standardized 440C stainless steel, and it supports thrust load including the weight of the driving system and external force. Friction and wear characteristics of this material operating under severe lubrication condition is not well known yet, although it is expected to be changed with respect to temperature and boundary pressure. So the friction characteristics are investigated in sliding conditions using the reciprocating tribometer which can simulate the operating conditions. Highly purified water is used as lubricant, and the water is heated up and pressurized. Friction farce on the reciprocating specimens is monitored by the load cells. The results of the experiments are presented in this paper.

  • PDF

수윤활 스테인레스강 볼베어링의 고온 마찰 특성 (Frictional Characteristics at High Temperature of Water-lubricated Stainless Steel Ball Bearing)

  • 이재선;김종인;김지호;박홍윤;지성균
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2003년도 학술대회지
    • /
    • pp.324-328
    • /
    • 2003
  • Water-lubricated frictional characteristics of stainless steel ball bearing is not well known compared to oil-lubricated frictional characteristics. Furthermore study on friction at high temperature is rare because bearing maintenance strategy for water-lubricated or chemicals-lubricated bearings of equipment is mostly based on change of failed bearings and parts. Ball bearings and ball screw are installed on the power transmission for a developing integral reactor and these are lubricated with high temperature and high pressure chemically-controlled pure water. Bearings and power transmitting mechanical elements for an atomic reactor needs high reliability. and high performance during estimated lifetime, and it should be verified. In this paper, experimental research results of frictional characteristics of water-lubricated ball bearing as a preliminary investigation.

  • PDF

필라멘트 와인딩 복합재의 환경노화에 따른 기계적물성 평가 (Behaviors of Mechanical Properties of Filament-Winding-Laminated Composites due to Environmental Aging)

  • 최낙삼;윤영주;이상우;김덕재
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2006년도 제26회 춘계학술대회논문집
    • /
    • pp.31-35
    • /
    • 2006
  • Degradation characteristics of filament-winded composites due to accelerated environmental aging have been evaluated under high temperature, water immersion and thermal impact conditions. Two kinds of laminated composites coated by an urethane resin have been used: carbon-fiber reinforced epoxy(T700/Epon-826, CFRP) and glass-fiber reinforced phenolic (E-glass/phenolic, GFRP). For tensile strength of $0^{\circ}$ composites, CFRP did high reduction by 25% under the influence of high temperature and water while CFRP showed little degradation. However for water-immersed $90^{\circ}$ composites both CFRP and GFRP showed high reduction in tensile strength. Bending strength and modulus of $90^{\circ}$ composites were largely reduced in water-immersion as well as high temperature environment. Urethane coating on the composite surface improved the bending properties by 20%, however hardly showed such improvement for water-immersed $90^{\circ}$ composites.

  • PDF

C. polykrikoides 적조 발생시의 한국 남해안의 수온 및 염분 분포 (Distributions of Water Temperature and Salinity in the Korea Southern Coastal Water During Cochlodinium polykrikoides Blooms)

  • 이문옥;최재훈
    • 한국해양환경ㆍ에너지학회지
    • /
    • 제12권4호
    • /
    • pp.235-247
    • /
    • 2009
  • 나로도를 중심으로 한 한국 남해안에서 발생하는 C. polykrikoides 적조의 원인 규명을 위해 1995년부터 2008년까지 국립수산과학원이 조사한 정선해양관측 및 위성정보 자료에 기초하여 동계 및 하계에 있어서의 수온염분 분포의 특징을 조사하였다. C. polykrikoides 적조는 나로도 주변 해역에서의 평균 수온이 약 $25.0{\sim}26.0^{\circ}C$, 염분이 약 31.00 psu 전후일 때 가장 많이 발생하였다. 한국남해 연안수와 외해수 사이에는 동계 및 하계에 각각 서로 다른 열염전선이 관측되었다. 즉, 동계에는 저온저염의 한국남해 연안수, 쓰시마 난류계의 중간수, 고온고염의 쓰시마 난류, 저온저염의 중국대륙 연안수 사이에 네 개의 전선이 관측되었다. 반면, 하계에는 저온고염의 한국남해 연안수, 고온저염의 쓰시마 난류, 고온고염의 중국대륙 연안수 사이에 두 개의 전선이 관측되었다. 이러한 열염전선은 서로 물리적 성질이 다른 수괴에 의해 형성된다는 사실이 T-S diagram을 통해서도 확인되었다. 이상으로부터, 나로도 주변해역에서 하계에 발생하는 C. polykrikoides 적조는 한국남해 연안수와 쓰시마 난류 사이에 형성되는 열염전선과 밀접한 연관을 가지고 있음을 알 수 있었다.

  • PDF

원수열원 히트펌프 축열시스템의 동절기 성능분석 (Winter Season Performance Characteristics of Raw Water-Source Heat Pump System with a Thermal Storage Tank)

  • 조용;이동근
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 춘계학술대회 초록집
    • /
    • pp.202-202
    • /
    • 2011
  • Performance of the raw water-source heat pump system with a thermal storage tank has been analyzed in winter season. The raw water is transferred through the multi-regional water supply system from Han river. Raw water is large temperature difference resource compared with groundwater. Although the raw water temperature drops to $0.6^{\circ}C$ due to the heavy snowfall and the severe cold in late January and early February, 2010, the system has been normally operated without any trouble this winter. The unit COP and system COP considered all pump power consumption were estimated based on the second-by-second data of the all sensors. The monthly averaged unit COP and system COP are 3.37 and 2.76 respectively with $1.4^{\circ}C$ of raw water in January, 3.55 and 2.89 with $1.6^{\circ}C$ raw water in February, 3.82 and 3.15 with $5.4^{\circ}C$ raw water in March. The performance of the system are increased with raw water temperature, and the COPs are higher than the water-to-air heat pump system using relatively high temperature raw water from Daecheong reservoir because the water-to-water system was operated on the full load condition and was stopped when the thermal storage tank was full of the high temperature water.

  • PDF

일산화탄소 저감을 위한 개질가스의 전이반응 연구 (Investigation of the Water Gas Shift from Reforming Gas for CO Removal)

  • 김성천;윤문중;전영남
    • 대한기계학회논문집B
    • /
    • 제31권10호
    • /
    • pp.855-859
    • /
    • 2007
  • Hydrogen as an energy carrier in fuel cell offers perhaps the largest potential benefits of reduced emissions of pollutants and greenhouse gases. The generation of high-purity hydrogen from hydrocarbon fuels is essential for efficient operation of fuel cell. Reduction of carbon monoxide to an acceptable level of 10ppm involves high temperature and low temperature water gas shift (WGS), followed by selective oxidation of residual carbon monoxide. The WGS reactor was designed and tested in this study to produce hydrogen-rich gas with CO to less than 5000 ppm. In the water gas shift operation, gas emerges from the reformer is taken through a high temperature shift (HTS) catalyst to reduce the CO concentration to about $2{\sim}4%$ followed to about 5000 ppm via a low temperature shift (LTS) catalyst.