• Title/Summary/Keyword: high temperature water

Search Result 4,456, Processing Time 0.043 seconds

The Influence of Water Temperature and Salinity on Filtration Rates of the Hard Clam, Meretrix petechialis (말백합의 연령별 여과율에 미치는 수온과 염분의 영향)

  • Lim, Kyeong-Hun;Jang, Kyu-Sang;Kim, In-Sou;Lee, Jeong-Ho;Shin, Hyun-Chool
    • The Korean Journal of Malacology
    • /
    • v.24 no.3
    • /
    • pp.175-188
    • /
    • 2008
  • This study was performed to describe the influence of water temperature and salinity on the filtration rate of the hard clam, Meretrix petechialis. The filtration rates of hard clams showed significant differences depending on both water temperature and age group (two-way ANOVA, p < 0.001). The filtration rate of all the hard clams, aged from 1 to 4 years, was generally reduced in low temperature range ( $5-15^{\circ}C$). As the water temperature increased, the filtration rate increased exponentially. The filtration rate was relatively high in $20-30^{\circ}C$ water temperature range, but rapidly decreased again at around $35^{\circ}C$. Variations in the data for filtration rates of hard clams, relative to age and changing water temperature, were used to determine the temperature coefficient $Q_{10}$ in each water temperature range. In $5-15^{\circ}C$ temperature range, every age group showed the highest $Q_{10}$ figure. It was found that on the whole, the higher the water temperature was, the lower the number of $Q_{10}$ was. Regardless of age, the number of $Q_{10}$ was higher in the lower water temperature range. In $25-35^{\circ}C$ temperature range, the number of $Q_{10}$ was less than 1.00 in all age groups, implying that this is the range in which the filtration rate decreased. Variations in the filtration rate also showed very clear differences (two-way ANOVA, p < 0.001) according to changing salinity and age. All the age groups, from 1 to 4 year olds, showed low filtration rates at both low salinity (10-15 psu) and high salinity (40 psu). The highest filtration rate was recorded at 30 psu, and relatively high filtration rates were found around 30 psu. However, the Student-Newman-Keuls post hoc multiple comparison test found that the hard clams in the 1-year group showed high filtration rates in a relatively narrower salinity range compared to those in the 2, 3, and 4 year groups. In other words, hard clams in the 2, 3, and 4 year groups showed high filtration rates at higher levels of salinity.

  • PDF

Effect of Cool Drinking Water on Production and Shell Quality of Laying Hens in Summer

  • Glatz, P.C.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.14 no.6
    • /
    • pp.850-854
    • /
    • 2001
  • Feed intake, egg weight, rate of lay and shell quality characteristics were measured in an Australian tinted egg laying strain from 31-42 weeks of age, housed at $30^{\circ}C$ and provided drinking water at 5, 10, 17 and $30^{\circ}C$. In a second experiment a European brown egg laying strain (59-66 weeks of age) housed at $30^{\circ}C$ were provided drinking water at 5, 10, 15 and $30^{\circ}C$. Brown egg layers given cool drinking water (5, 10 and $15^{\circ}C$) consumed more (p<0.05) feed and produced significantly (p<0.05) thicker and heavier shells than hens given drinking water at ambient temperature ($30^{\circ}C$). However the tinted egg layers given chilled drinking water only consumed more (p<0.05) feed and produced thicker (p<0.05) and heavier (p<0.05) shells when consuming drinking water at $5^{\circ}C$. As the tinted egg layers acclimatised to the environmental temperature there was a decline in the influence of cool drinking water on feed intake and shell quality. For brown egg layers, however, cool drinking water resulted in an improvement (p<0.05) in feed intake and shell quality over the entire period birds were provided cool water. These studies suggest that there is potential for using cool drinking water to improve feed intake and shell quality of hens housed under hot conditions. The combination of high ambient temperature and high drinking water temperature, a common occurrence in Australian layer sheds, should be avoided.

Correlation and Hysteresis Analysis of Air-Water Temperature in Four Rivers: Preliminary study for water temperature prediction (우리나라 하천의 기온-수온의 상관관계 및 이력현상 분석: 미래 하천수온 변화 예측을 위한 사전검토)

  • An, Ji-Hyuck;Lee, Khil-Ha
    • Journal of Environmental Policy
    • /
    • v.12 no.2
    • /
    • pp.17-32
    • /
    • 2013
  • The potential impact of water temperature on air temperature in response to recent anthropogenic global warming has been noticed. To predict climate, induced change in river aquatic environment, it is necessary to understand the thermal constrains of fish species and the timing of the projected river temperature. As a preliminary study, air-water temperature relationship was analyzed on the basis of the observed data during the time period of 2009-2011 and the number of data corresponds to 873-1083. As a result of analyzing the auto-and cross-correlation coefficient between air-water temperature, high correlation is shown (~0.9). It is also found that the correlation coefficient of air temperature is higher than that of water temperature at the lag time less than approximately 10 days. Observed data was divided into two groups to investigate hysteresis: rising limb and falling limb. For some stations there is strong evidence that hysteresis exist between air-water temperature relationships. Consequently it is recommended that seasonal hysteresis needs to be included in determining an airwater relationship.

  • PDF

Positive Study of How Green Zones in the City Effect the Relief of Micro-Climate Control (도시녹지가 미기상조절에 미치는 실증적 연구)

  • 윤용한
    • Korean Journal of Environmental Biology
    • /
    • v.22 no.2
    • /
    • pp.279-286
    • /
    • 2004
  • This study observed the temperature and humidity within the green zone to understand the effect that land coverage and the structure of forests have on the relief of micro-climate control. Based on this set of data, this study interpreted, through the regression analysis, the relevance of land coverage of the green zone with temperature and distribution of humidity, as well as the amount of green with the relief of microclimate control. The results of the study demonstrated that high temperature regions were formed in barren areas, and low temperature regions in forests or near the water. In particular, low temperature was found in areas covered with tall and small trees, the water surrounded by forests and areas enclosing small rivers. Furthermore, mechanisms causing low temperature were, among others, the ratio of land coverage (forest, grassland, water). In fact, the temperature reduction effect varied in accordance with the types and ratios of the land coverage. Humidity also showed a close correlation with the distribution of temperature high temperature areas had low humidity and low temperature areas had high humidity. Such a phenomenon.

Analysis of Grid Spring Characteristic of Fuel Assembly in High Temperature and High Pressure Environment (고온고압조건하에서의 핵연료 피복관 지지스프링의 하중-변위 특성 분석)

  • Lee, Young-Ho;Kim, Hyung-Kyu;Jung, Youn-Ho
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.2146-2150
    • /
    • 2004
  • To evaluate the variation of spring stiffness in nuclear plant operating condition, load-displacement tests ($P-{\delta}$ test) were performed using two kinds of space grid springs in high temperature and high pressure water. With increasing temperature, stiffness of each spring gradually decreased except $100{\sim}150^{\circ}C$. It is apparently showed that spring with convex shape had a relatively high stability of spring stiffness at high temperature compared with I-shaped spring. It is suggested that the variation of spring stiffness with temperature and spring shape should be considered as an important variable in the design and analysis of the fuel assembly.

  • PDF

Analysis of Water Circulation Characteristics for Hydraulic and Water Temperature Investigation in Paldang Reservoir (팔당호의 수리 및 수온 조사를 통한 물순환특성 분석)

  • Choi, Hwang Jeong;Cho, Yong-Chul;Yu, Soonju;Song, Yong Sik;Ryu, Ingu
    • Ecology and Resilient Infrastructure
    • /
    • v.6 no.1
    • /
    • pp.12-22
    • /
    • 2019
  • This study investigated the spatial and temporal water circulation characteristics of Paldang Reservoir by continuous hydraulic and water temperature survey. Due to differences in water temperature and discharge pattern of Ipo Weir and Cheongpyeong Dam, the flow and temperature fluctuations were different in sections of Namhan River and Bukhan River in Paldang Reservoir. At the stratification period, the water temperature of the discharge of Ipo Weir was higher than that of the Cheongpyeong Dam. Therefore, in the surface layer of the downstream of Bukhan River, relatively high temperature water is located and back water phenomenon occurred, and convergence zone is formed. In the downstream section of Namhan River, low-temperature water was distributed in the middle and lower layers, and the upstream flow appeared to be difficult to mix with the surface layer.

The Study on Drag Reduction Rates and Degradation Effects in Synthetic Polymer Solution with Surfactant Additives (계면활성제를 이용한 합성고분자 수용액의 마찰저항감소 및 퇴화 특성 향상 연구)

  • 이동민;김남진;윤석만;김종보
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.3
    • /
    • pp.194-199
    • /
    • 2001
  • The turbulent flow resistance of water solution with polymer is reduced as compared with that of pure water. This effects is named th drag reduction and offers the significant reduction of the pumping power and the energy consumption. But the intense shear forces and the high temperature experienced by the polymer solution when passing through the pipes cause the degradation a loss of drag reduction effectiveness. Especially, the degradation behavior is found to be strongly dependent on temperature. This mechanical and thermal degradation can be avoided by adding materials such as surfactant to the polymer solution, which enhance the bonding force between molecules. In the present study, Copolymer and SDS were utilized and they were mixed in 10 different mixture ratios, while total concentration was fixed as 100wppm. Degradation of Copolymer-SDS mixture solutions was investigated experimentally in closed loop at the temperature of $10^{\circ}C\; and\; 80^{\circ}C$ with various flow average velocities of 1.5 m/sec, 3.0m/sec, and 4.5m/sec. Degradation characteristics of polymer solution without surfactant show a radical loss of drag reduction effectiveness at high temperature. Degradation alleviation ability of surfactant is especially effective at high temperature. Consequently, this results show that the addition of surfactant to the polymer solution can control unfavorable degradation phenomena for high temperature systems.

  • PDF

Thermal Analysis of Reinforced Concrete Members at High Temperature (고온하에서 철근콘크리트부재의 온도해석)

  • Lee, Tae-Gyu
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.1102-1105
    • /
    • 2008
  • In this paper, the prediction method of internal temperature for high strength concrete members at high temperature is presented. Finite element method is employed to facilitate thermal analysis for any position of member. In case of water evaporates inside the concrete member by high temperature, the evaporation heat that absorb surrounding temperature is occurred. This effect of the evaporation heat is applied. And the model equations of the material characteristics of high strength concrete by high temperature are proposed. To demonstrate the validity of this numerical procedure, the prediction by the proposed algorithm is compared with the test results of other researchers. The proposed algorithm is good agreement with experimental results including the phenomenon that temperature by the evaporation heat is lost.

  • PDF

Effect of Water Temperature on Generation of Ion Migration (이온 마이그레이션 발생에 대한 수분온도의 영향)

  • Lee Deok Bo;Kim Jung Hyun;Kang Soo Keun;Kim Sang Do;Jang Seok Won;Lim Jae Hoon;Ryu Dong Soo
    • Journal of Applied Reliability
    • /
    • v.5 no.2
    • /
    • pp.261-272
    • /
    • 2005
  • In evaluation of electronic reliability on the PCB(Printed Circuit Board), electrochemical migration is one of main test objects. The phenomenon of electrochemical migration occurs In the environment of the high humidity and the high temperature under bias through a continuous aqueous electrolyte. In this paper, the generating mechanism of electrochemical migration is investigated by using water droll acceleration test under various waters. The waters used in the water drop test are city water, distilled water and ionic water. It found that the generated velocity of electrochemical migration depended on the temperature of water and the electrolyte quantity which included in the various waters.

  • PDF

Effect of Water Temperature on Generation of Ion Migration (이온 마이그레이션 발생에 대한 수분온도의 영향)

  • Lee Deok Bo;Kim Jung Hyun;Kang Soo Keun;Kim Sang Do;Jang Seok Won;Lim Jae Hoon;Ryu Dong Soo
    • Proceedings of the Korean Reliability Society Conference
    • /
    • 2005.06a
    • /
    • pp.339-348
    • /
    • 2005
  • In evaluation of electronic reliability on the PCB(Printed Circuit Board),electrochemical migration is one of main test objects. The phenomenon of electrochemical migration occurs In the environment of the high humidity and the high temperature under bias through a continuous aqueous electrolyte. In this paper, the generating mechanism of electrochemical migration is investigated by using water drop acceleration test under various waters. The waters used in the water drop test are city water, distilled water and ionic water. It found that the generated velocity o of electrochemical migration depended on the temperature of water and the electrolyte quantity which included in the various waters.

  • PDF