• Title/Summary/Keyword: high temperature exposure

Search Result 538, Processing Time 0.024 seconds

Effect of High Temperature Degradation on Microstructure and High Temperature Mechanical Properties of Inconel 617 (Inconel 617의 고온열화에 따른 미세구조 및 고온 기계적 특성)

  • Jo, Tae-Sun;Lee, Seung-Ho;Kim, Gil-Su;Kim, Se-Hoon;Kim, Young-Do
    • Korean Journal of Materials Research
    • /
    • v.17 no.5
    • /
    • pp.268-272
    • /
    • 2007
  • Inconel 617 is a candidate tube material for high temperature gas-cooled reactors(HTGR). The microstructure and mechanical properties of Inconel 617 were studied after exposure at high temperature($1050^{\circ}C$). The dominant oxide layer was Cr-oxide. The internal oxide and Cr-depleted region were observed below the Cr-oxide layer. The depth of Cr-depleted zone and internal oxide increased with exposure time. The major phases of carbides are $M_{23}C_6\;and\;M_6C$. The composition of $M_{23}C_6\;and\;M_6C$ were determined to be Cr-rich and Mo-rich, respectively. $M_6C$ carbide is more stable than $M_{23}C_6$ at high temperature. From the results of high temperature compression test, there were no significant changes in hardness and yield strength upon increasing exposure time.

Critical Temperature for Inter-Laminar Shear Strength and Effect of Exposure Time of FRP Rebars (FRP 보강근의 계면전단강도에 대한 임계온도와 노출시간의 영향)

  • Moon, Do-Young
    • Journal of the Korea Concrete Institute
    • /
    • v.25 no.1
    • /
    • pp.45-51
    • /
    • 2013
  • Short beam tests of GFRP and CFRP specimens exposed to high temperature were conducted to measure the inter-laminar shear strength. For the phase I test, the exposure time and temperature were varied to measure reduction in the strength due to the applied conditions. As a results, the critical temperature was found to $270^{\circ}C$ for the both FRP reinforcements. The high temperature, which causes 50% loss of inter-laminar shear strength, is defined as the critical temperature in this study. It should be noted that the critical temperature for the inter-laminar shear strength is mainly dependent on resin properties not on fiber type. In the phase II test, the effect of exposure time was investigated at intervals of 0.25hour for the critical temperature. All test results demonstrate that the exposure time effect is not significant compared to the maximum exposure temperature, but it is not negligible and, moreover, is significant at the critical temperature.

Residual behavior of SRRAC beam and column after exposure to high temperatures

  • Zhou, Ji;Chen, Zongping;Zhou, Chunheng;Zheng, Wei;Ye, Peihuan
    • Steel and Composite Structures
    • /
    • v.45 no.3
    • /
    • pp.369-388
    • /
    • 2022
  • Composite effect between steel and recycled aggregate concrete (RAC) in steel reinforced-RAC (SRRAC) structures can effectively improve RAC's adverse mechanical properties due to the natural defects of recycled coarse aggregate (RCA). However, the performance of SRRAC after thermal exposure will have a great impact on the safety of the structure. In this paper, firstly, the mechanical properties of SRRAC structures after high temperatures exposure were tested, including 24 SRRAC columns and 32 SRRAC beams. Then, the change rules of beams and columns performance with the maximum temperature and replacement percentage were compared. Finally, the formulas to evaluate the residual bearing capacity of SRRAC beams and columns after exposure to high temperatures were established. The experimental results show that the maximum exposure temperature can be judged by the apparent phenomenon and mass loss ratio of RAC. After high temperatures exposure, the mechanical properties of SRRAC beams and columns change significantly, where the degradation of bearing capacity and stiffness is the most obvious. Moreover, it is found that the degradation degree of compression member is more serious than that of flexural member. The formulas of residual bearing capacity established by introducing influence coefficient of material strength agree well with the experimental results.

Fire Resistance Studies on High Strength Steel Structures

  • Wang, Wei-Yong;Xia, Yue;Li, Guo-Qiang
    • International Journal of High-Rise Buildings
    • /
    • v.7 no.4
    • /
    • pp.287-298
    • /
    • 2018
  • High strength steels have been widely applied in recent years due to high strength and good working performance. When subjected to fire conditions, the strength and elastic modulus of high strength steels deteriorate significantly and hence the load bearing capacity of structures reduces at elevated temperatures. The reduction factors of mechanical properties of high strength steels are quite different from mild steels. Therefore, the fire design methods deduced from mild steel structures are not applicable to high strength steel structures. In recent ten years, the first author of this paper has carried out a lot of fundamental research on fire behavior of high strength steels and structures. Summary of these research is presented in this paper, including mechanical properties of high strength steels at elevated temperature and after fire exposure, creep response of high strength steels at elevated temperature, residual stresses of welded high strength steel member after fire exposure, fire resistance of high strength steel columns, fire resistance of high strength steel beams, local buckling of high strength steel members, and residual strength of high strength steel columns after fire exposure. The results show that the mechanical properties of high strength steel in fire condition and the corresponding fire resistance of high strength steel structures are different from those of mild steel and structures, and the fire design methods recommended in current design codes are not applicable to high strength steel structures.

Occupational Exposure to Refractory Ceramic Fibers in the Semiconductor Scrubber Manufacturing Industry

  • Song, Seungwhan;Kim, Sunju;Kim, Donghyeon;Yoon, Chungsik
    • Safety and Health at Work
    • /
    • v.13 no.3
    • /
    • pp.357-363
    • /
    • 2022
  • Background: Refractory ceramic fibers (RCFs) are a suspected carcinogen but have been widely used as insulations. Depending on the temperature, RCFs can transform into crystalline SiO2, which is a carcinogen that can be present in the air during bulk RCF handling. This study analyzed the physicochemical and morphological characteristics of RCFs at high temperatures and determined the exposure levels during the semiconductor scrubber maintenance. Methods: Sampling was conducted at a company that manufactures semiconductor scrubbers using RCFs as insulation. Bulk RCF samples were collected both before and after exposure to a scrubber temperature of 700℃. Airborne RCFs were collected during scrubber maintenance, and their characteristics were analyzed using microscopes. Results: The components of bulk RCFs were SiO2 and Al2O3, having an amorphous structure. Airborne RCFs were morphologically different from bulk RCFs in size, which could negatively affect maintenance workers' health. 58% of airborne RCFs correspond to the size of thoracic and respirable fibers. RCFs did not crystallize at high temperatures. The exposure caused by airborne RCFs during the scrubber frame assembly and insulation replacement was higher than the occupational exposure limit. Conclusion: Workers conducting insulation replacement are likely exposed to airborne RCFs above safe exposure limits. As RCFs are suspected carcinogens, this exposure should be minimized through prevention and precautionary procedures.

A Study on the Plasma Biochemical Indices of Heat-Stressed Broilers

  • Lin, H.;Du, R.;Gu, X.H.;Li, F.C.;Zhang, Z.Y.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.13 no.9
    • /
    • pp.1210-1218
    • /
    • 2000
  • Four experiments were conducted to evaluate the effect of temperature and humidity on biochemical indices of Arbor Acres broilers at different weeks of age. The alkaline phosphatase (AKP), acid phosphatase (ACP), lactic dehydrogenase (LD), creatine kinase (CK), plasma glucose (Glu), calcium (Ca), potassium (K), chloride (Cl), urea nitrogen (UN), uric acid (UA), plasma thyroxin (T4), triiodothyronine (T3) and insulin levels were determined in all the four experiments. In experiment 1, the plasma Glu, LD and CK levels were increased by heat exposure ($35{^{\circ}C}$ and 35, 60, or 85% RH, 2 h) and this effect was aggravated by longer exposure (24 h). No significant changes (p>0.05) were found in Ca concentration, activity of AKP and ACP. In experiment 2, temperature (10, 20, 30, $33{^{\circ}C}$) had significant effect on the levels of K, Cl, UN, UA levels and the activity of LD (p<0.01), but had no significant influence on the activity of CK (p>0.05). The UN, UK and LD levels were elevated by low temperature $(10{^{\circ}C})$ (p<0.01), Cl content was increased by high temperature ($(33{^{\circ}C})$ (p<0.01), and K level was decreased by high ($(33{^{\circ}C})$ or low $(10{^{\circ}C})$ temperature and increased by medium temperature $(30{^{\circ}C})$ (p<0.01). The humidity (35, 85% RH) only had significant effect on Cl concentration which was decreased by high humidity (p<0.01). In experiment 3, the result showed that only the LD and CK activity were significantly increased (p<0.01) by high temperature (7, 24, 28, $32{^{\circ}C}$) or high humidity (35, 85% RH). Temperature and humidity had no significant effect on K, Cl, UA, UN and Glu levels (p>0.05). In experiment 4 (24, 27, 30, $33{^{\circ}C}$; 30, 45, 60, 75, 90% RH), plasma T3 level was declined by high temperature $(33{^{\circ}C})$, and this phenomena disappeared in birds under high temperature and high humidity environment. T4 concentration in plasma was not affected by temperature (p>0.05), but was increased by high or low humidity (p<0.01). Neither temperature nor humidity had significant effect on plasma insulin concentration (p>0.05). The results of the four experiments suggested that broilers at different growth periods might have different thermal requirements and would response differently to heat exposure. The plasma biochemical indices themselves had big variation; the reaction of the indices to thermal exposure treatment differed with the age of broilers. The big variation of biochemical indices themselves might cover the response of indices to temperature and humidity treatments.

Experiment for the Improvement of Fire Resistance Capacity of Reinforced Concrete Flexural Member Strengthened with Carbon Fiber Reinforced Polymer (CFRP로 보강된 철근콘크리트 휨부재의 내화성능 개선을 위한 실험)

  • Lim, Jong-Wook;Seo, Soo-yeon;Song, Se-Ki
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.33 no.12
    • /
    • pp.19-27
    • /
    • 2017
  • This paper is a study to improve the fire-resistance capacity of reinforced concrete (RC) members strengthened by fiber-reinforced-polymer (FRP). The fire resistance of the RC members strengthened by FRP was evaluated through high temperature exposure test. In order to improve the fire resistance of the FRP reinforcing method, a fire-proof board was attached to the reinforced FRP surface and then the high temperature exposure test was carried out to evaluate the improvement of the fire resistance performance. It was confirmed that the resistance to high temperature of NSMR could be improved somewhat compared with that of EBR from the experiment that exposed to high temperature under the load corresponding to 40% of nominal strength. When 30 mm thick fire-resistance (FR) board is attached to the FRP surface, the surface of the reinforced FRP does not reach $65^{\circ}C$, which is the glass transition temperature (GTT) of the epoxy until the external temperature reaches $480^{\circ}C$. In particular, when a high performance fire-proof mortar was first applied prior to FR board attachment, the FRP portion did not reach the epoxy glass transition temperature until the external temperature reached $600^{\circ}C$.

Performance evaluation of plasma nitrided 316L stainless steel during long term high temperature sodium exposure

  • Akash Singh;R. Thirumurugesan;S. Krishnakumar;Revati Rani;S. Chandramouli;P. Parameswaran;R. Mythili
    • Nuclear Engineering and Technology
    • /
    • v.55 no.4
    • /
    • pp.1468-1475
    • /
    • 2023
  • Enhancement of wear resistance of components used in fast reactors is necessary for long service life of the components. Plasma nitriding is a promising surface modification technology to impart high hardness and improved wear resistance of various steel components. This study discusses the characterization of chrome nitrided SS316L casing ring used in secondary sodium pump of fast breeder reactor and its stability under long term sodium exposure. Microstructural and hardness analysis showed that stress relieved component could be chrome nitrided successfully to a thickness of about 100 ㎛. Assessment of in-sodium performance of the chrome nitrided casing ring subjected to long term exposure up to 5000h at 550℃, showed retention of chrome nitrided layer with a case depth almost similar to that before sodium exposure. A slight decrease in the hardness was observed due to prolonged high temperature sodium exposure. Tribological studies indicate very low coefficient of friction indicating the retention of good wear resistance of the coating even after long term sodium exposure.

Corrosion behaviors of 18Cr Stainless Steels in Selective Catalytic Reduction Environments (Selective Catalytic Reduction (SCR) 환경에서 18% 크롬 스테인리스강의 부식 거동)

  • Heesan Kim
    • Corrosion Science and Technology
    • /
    • v.22 no.3
    • /
    • pp.175-186
    • /
    • 2023
  • Effects of high-temperature environment and low-temperature environment on corrosion behaviours of 18Cr stainless steels (type 304L, type 441) in simulated selective catalytic reduction (SCR) environments were studied using weight loss test in each environment and rust analysis. With time to exposure to the high-temperature environment, type 441 was more resistant to corrosion than type 304L due to both higher diffusivity of Cr and lower thermal expansion coefficient in α-iron. The former provides a stable protective Cr2O3 layer. The latter leaded to low residual stress between scale and steel, reducing the spallation of the scale. With time to exposure to the low-temperature environment, on the other hand, type 304L was more resistant to corrosion than type 441. The lower resistance of type 441 was caused by Cr-depleted zone with less than 11% formed during the pre-exposure to a high-temperature environment, unlike type 304L. It was confirmed by results from the crevice corrosion test of sensitised 11Cr steel. Hence, to achieve higher corrosion resistance in simulated SCR environments, ferritic stainless steels having lower thermal expansion coefficient and higher diffusivity of Cr but containing more than 18% Cr are recommended.

Evaluation of Failure Mechanism of Flexible CIGS Solar Cell Exposed to High Temperature and Humid Atmosphere (플렉서블 CIGS 태양전지의 고온고습 환경 고장 기구 분석)

  • Kim, Hyeok-Soo;Byeon, Jai-Won
    • Journal of Applied Reliability
    • /
    • v.16 no.1
    • /
    • pp.41-47
    • /
    • 2016
  • Purpose: The purpose of this study was to evaluate electrical and structural degradation of flexible CIGS sollar cell exposed to high temperature and humid atmosphere. Method: Accelerated degradation was performed for various time under $85^{\circ}C/85%RH$ and then electrical and structural properties were analyzed by 4-point probe method, scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS), and X-ray diffraction (XRD). Results: Sheet resistance of the top ITO layer increased with exposure time to the high temperature and humid atmosphere. Blunting of the protrusion morphology of ITO layer was observed for the degraded specimen, while no phase change was detected by XRD. Oxygen was detected at the edge area after 300 hours of exposure. Conclusion: Increase in electrical resistance of the degraded CIGS solar cell under high temperature and humid environment was attribute to the oxygen or water absorption.