Experimental studies of headed stud shear connectors in UHPC Steel composite slabs

  • Gao, Xiao-Long;Wang, Jun-Yan;Yan, Jia-Bao
    • Structural Engineering and Mechanics
    • /
    • 제74권5호
    • /
    • pp.657-670
    • /
    • 2020
  • Due to the high compressive and tensile strength of ultra-high performance concrete (UHPC), UHPC used in steel concrete composite structures provided thinner concrete layer compared to ordinary concrete. This leaded to the headed stud shear connectors embedded in UHPC had a low aspect ratio. In order to systematic investigate the effect of headed stud with low aspect ratio on the structural behaviors of steel UHPC composite structure s this paper firstly carried out a test program consisted of twelve push out specimens. The effects of stud height, aspect ratio and reinforcement bars in UHPC on the structural behaviors of headed studs were investigated. The push out test results shows that the increasing of stud height did not obviously influence the structural behaviors of headed studs and the aspect ratio of 2.16 was proved enough to take full advantage of the headed stud strength. Based on the test results, the equation considering the contribution of weld collar was modified to predict the shear strength of headed stud embedded in UHPC. The modified equation could accurately predict the shear strength of headed stud by comparing with the experimental results. On the basis of push out test results, bending tests consisted of three steel UHPC composite slabs were conducted to investigate the effect of shear connection degree on the structural behaviors of composite slabs. The bending test results revealed that the shear connection degree had a significantly influence on the failure modes and ultimate resistance of composite slabs and composite slab with connection degree of 96% in s hear span exhibited a ductile failure accompanied by the tensile yield of steel plate and crushing of UHPC. Finally, analytical model based on the failure mode of composite slabs was proposed to predict the ultimate resistance of steel UHPC composite slabs with different shear connection degrees at the interface.

고강도(高强度) 스터드 볼트의 역학적 특성에 관한 연구 (Mechanical Properties of High Strength Shear Connector)

  • 엄철환
    • KIEAE Journal
    • /
    • 제12권5호
    • /
    • pp.93-98
    • /
    • 2012
  • The headed studs those are used extensively for steel-composite construction is specified as SS400 at the current Korean Standard specification considering the welding condition. And the corresponding equation for the shear force calculation is limited for the use of compression strength of concrete below $300kg/cm^2$. However, it is expected that the high strengthening and precast of both steel and concrete due to the necessity of shear connector or other connecting material for the combination of steel and concrete. Therefore, the experimental results obtained during the development process of high strength stud for the connection of high strength concrete and the steel member are reported in this paper. Also the effectiveness of newly developed shear connector using pipe to increase the stiffness of a stud is verified by comparing both the stiffness and the strength with common stud bolt through the welding ability, mechanical characteristics and experimental investigation.

Static behaviour of multi-row stud shear connectors in high- strength concrete

  • Su, Qingtian;Yang, Guotao;Bradford, Mark A.
    • Steel and Composite Structures
    • /
    • 제17권6호
    • /
    • pp.967-980
    • /
    • 2014
  • In regions of high shear forces in composite bridges, headed stud shear connectors need to be arranged with a small spacing in order to satisfy the design requirement of resisting the high interface shear force present at this location. Despite this, studies related to groups of headed studs are somewhat rare. This paper presents an investigation of the static behaviour of grouped stud shear connectors in high-strength concrete. Descriptions are given of five push-out test specimens with different arrangements of the studs that were fabricated and tested, and the failure modes, load-slip response, ultimate load capacities and related slip values that were obtained are reported. It is found that the load-slip equation given by some researchers based on a single stud shear connector in normal strength concrete do not apply to grouped stud shear connectors in high-strength concrete, and an algebraic load-slip expression is proposed based on the test results. Comparisons between the test results and the formulae provided by some national codes show that the equations for the ultimate capacity provided in these codes are conservative when used for connectors in high-strength concrete. A reduction coefficient is proposed to take into account the effect of the studs being in a group.

Experimental and numerical study on static behavior of grouped large-headed studs embedded in UHPC

  • Hu, Yuqing;Zhao, Guotang;He, Zhiqi;Qi, Jianan;Wang, Jingquan
    • Steel and Composite Structures
    • /
    • 제36권1호
    • /
    • pp.103-118
    • /
    • 2020
  • The static behavior of grouped large-headed studs (d = 30 mm) embedded in ultra-high performance concrete (UHPC) was investigated by conducting push-out tests and numerical analysis. In the push-out test, no splitting cracks were found in the UHPC slab, and the shank failure control the shear capacity, indicating the large-headed stud matches well with the mechanical properties of UHPC. Besides, it is found that the shear resistance of the stud embedded in UHPC is 11.4% higher than that embedded in normal strength concrete, indicating that the shear resistance was improved. Regarding the numerical analysis, the parametric study was conducted to investigate the influence of the concrete strength, aspect ratio of stud, stud diameter, and the spacing of stud in the direction of shear force on the shear performance of the large-headed stud. It is found that the stud diameter and stud spacing have an obvious influence on the shear resistance. Based on the test and numerical analysis results, a formula was established to predict the load-slip relationship. The comparison indicates that the predicted results agree well with the test results. To accurately predict the shear resistance of the stud embedded in UHPC, a design equation for shear strength is proposed. The ratio of the calculation results to the test results is 0.99.

Reinforcing effect of CFRP bar on concrete splitting behavior of headed stud shear connectors

  • Huawen Ye;Wenchao Wang;Ao Huang;Zhengyuan Wang
    • Steel and Composite Structures
    • /
    • 제48권2호
    • /
    • pp.131-143
    • /
    • 2023
  • The CFRP bar was used to achieve more ductile and durable headed-stud shear connectors in composite components. Three series of push-out tests were firstly conducted, including specimens reinforced with pure steel fibers, steel and CFRP bars. The distributed stress was measured by the commercial PPP-BOTDA (Pre-Pump-Pulse Brillouin optical time domain analysis) optical fiber sensor with high spatial resolution. A series of numerical analyses using non-linear FE models were also made to study the shear force transfer mechanism and crack response based on the test results. Test results show that the CFRP bar increases the shear strength and stiffness of the large diameter headed-stud shear connection, and it has equivalent reinforcing effects on the stud shear capacity as the commonly used steel bar. The embedded CFRP bar can also largely improve the shear force transfer mechanism and decrease the tensile stress in the transverse direction. The parametric study shows that low content steel fibers could delay the crack initiation of slab around the large diameter stud, and the CFRP bar with normal elastic modulus and the standard reinforcement ratio has good resistance to splitting crack growth in headed stud shear connectors.

초고성능 콘크리트 바닥판 교량의 전단연결부에 대한 실험적 연구 (An Experimental Study on the shear connection for UHPC Deck Bridge)

  • 유동민;황훈희;김성태;박성용
    • Composites Research
    • /
    • 제24권5호
    • /
    • pp.29-33
    • /
    • 2011
  • 교량 바닥판에서 고성능 재료의 적용은 고가임에도 불구하고 바닥판 중량 감소와 경제성 향상을 위한 대안으로 대표될 수 있다. 초고성능콘크리트 재료를 활용한 교량에서 기존의 헤드형 스터드가 바닥판과 강재 거더사이의 전단력을 충분히 전달할 수 있는지 그 적용성을 검증할 필요가 있다. 이 논문에서는 UHPC 교량 바닥판과 강재 거더의 합성거동을 분석하기 위해 2면 전단실험을 수행하였다. 정적 재하 실험 결과 헤드형 스터드의 실험체별 극한강도는 직경에 비례였으며, 일반 콘크리트, 교량 바닥판에 비해 전단강도가 향상되는 것으로 나타났다.

Shear behavior of a demountable bolted connector in steel-UHPC lightweight composite structures

  • Gu, Jin-Ben;Wang, Jun-Yan
    • Structural Engineering and Mechanics
    • /
    • 제81권5호
    • /
    • pp.551-563
    • /
    • 2022
  • Bolted connector could be an alternative to replace the conventional welded headed stud in steel-ultra high performance concrete (UHPC) lightweight composite structures. In this paper, a novel demountable bolted shear connector, consisting of a high-strength bolt (HSB) and a specially-designed nut which is pre-embedded in a thin UHPC slab, is proposed, which may result in the quick installation and disassembly, due to the mountable, demountable and reusable features. In order to study the shear behavior of the new type of bolted shear connector, static push-out tests were conducted on five groups of the novel demountable bolted shear connector specimens and one group of conventional welded headed stud specimen for comparison. The effect of the bolt shank diameter and aspect ratio of bolt on failure mode, shear stiffness, peak slip at the steel-UHPC interface, shear strength and ductility of novel bolted connectors is investigated. Additionally, design formula for the shear strength is proposed to check the suitability for assessment of the novel demountable bolted shear connectors.

Experimental studies on the behaviour of headed shear studs for composite beams in fire

  • Lim, Ohk Kun;Choi, Sengkwan;Kang, Sungwook;Kwon, Minjae;Choi, J. Yoon
    • Steel and Composite Structures
    • /
    • 제32권6호
    • /
    • pp.743-752
    • /
    • 2019
  • Steel and concrete composite structures are commonly applied in multi-story buildings as they maximise the material strength through composite action. Despite the popularity of employing a trapezoidal deck slab, limited experimental data are available under elevated temperatures. The behaviour of the headed shear stud embedded in a transverse trapezoidal deck and solid slab was investigated at both ambient and fire conditions. Twelve push-out tests were conducted according to the ISO 834 standard fire utilising a customised electric furnace. A stud shearing failure was observed in the solid slab specimen, whereas the failure mode was changed from a concrete-dominated failure to the stud shearing in the transverse deck specimen with an increase in temperature. Comparisons between the experimental observations and design requirements are presented. The Eurocode design guidance on the transverse deck slab gives a highly conservative estimate for shear resistance. A new design formula was proposed to determine the capacity of the shear connection regardless of the slab type when the stud shearing occurs at high temperatures.

초고성능 콘크리트 바닥판을 위한 스터드 전단연결재의 정적 거동 (Static Behavior of Stud Shear Connector for UHPC Deck)

  • 이경찬;곽종원;박상혁;김지상
    • 콘크리트학회논문집
    • /
    • 제26권5호
    • /
    • pp.573-579
    • /
    • 2014
  • 합성보는 콘크리트 바닥판과 강재 거더로 이루어져 왔으나, 바닥판의 자중을 줄이면서 내구성을 향상시키고 나아가 교량의 강도 및 강성을 향상시키기 위하여 초고성능 콘크리트(UHPC)를 교량 바닥판으로 채용한 합성보가 최근에 제안되고 있다. 이 연구는 기존의 스터드 전단연결재가 UHPC 바닥판을 합성함에 있어 유효한지에 관하여 실험적으로 검토해보고자 한다. 12개의 push-out 시험체를 통하여 UHPC 바닥판에 매립된 스터드 전단연결재의 정적 강도를 평가하였으며, 실험 변수로 바닥판 두께, 스터드 높이 및 지름을 채택하여, 기존에 제한되었던 스터드 지름에 대한 높이의 비율인 형상비와 스터드 머리부 상부 콘크리트 피복두께의 제한을 완화하는 것이 가능한지에 대하여 검토하였다. 이 연구의 실험으로부터 기존 AASHTO LRFD에 제시된 정적 강도평가식을 UHPC에 매립된 스터드 전단연결재에 적용하는 것이 유효함을 확인하였으며, 4이상으로 제한된 형상비는 3.1까지 낮추어도 되며, 50 mm로 제한된 최소 피복두께도 25 mm까지 낮출수 있음을 확인하였다. 다만 Eurocode-4에 제시된 연성도 기준인 특성 상대슬립 6 mm 이상의 기준을 만족하지 못하여, UHPC에 매립된 스터드 전단연결재는 별도의 연성 보강 방안이 채택되지 않는다면 강성 전단연결재로 간주하여야 할 것이다.

고강성 스터드볼트의 역학적 특성에 관한 연구 (Mechanical Properties of High Stiffness Shear Connector)

  • 엄철환
    • 한국전산구조공학회논문집
    • /
    • 제28권5호
    • /
    • pp.491-496
    • /
    • 2015
  • 합성보의 쉬어코넥트로 널리 사용되고 있는 스터드볼트는 현재 학회규준에 강재의 재질은 용접성을 고려한 SS400이 규정되어 있으며, 그 전단내력의 산정식은 압축강도 $300kgf/cm^2$ 이하의 콘크리트를 대상으로 하고 있다. 한편 합성구조의 보급에 따라 합성보 뿐만 아니라 다른 구조부분에서도 강재과 콘크리트를 결합하는 쉬어코넥트 혹은 다른 용도의 접합재의 필요성과 함께 강재와 콘크리트의 고강도화, 프리캐스트화가 예상된다. 따라서 본 연구에서는 고강도 콘크리트와 강부재를 결합하기 위한 고강도 스터드의 개발을 목적으로 행하여진 일련의 실험결과를 보고하였다. 또한 스터드의 강성을 증대시키기 위한 강관을 이용한 쉬어콘넥트(이하, 파이프 스터드라고 한다)를 고안하였다. 본 논문에서는 고강도 스터드의 용접성, 역학특성에 관한 실험적 검토와 동시에 고강도 고강성 스터드인 파이프 스터드의 강성 내력을 종래의 스터드 볼트와의 비교실험을 하여 파이프 스터드의 유효성을 검증한다.