• 제목/요약/키워드: high strength column

검색결과 610건 처리시간 0.026초

Experimental investigation on the seismic performance of cored moment resisting stub columns

  • Hsiao, Po-Chien;Lin, Kun-Sian
    • Steel and Composite Structures
    • /
    • 제39권4호
    • /
    • pp.353-366
    • /
    • 2021
  • Cored moment resisting stub column (CMSC) was previously developed by the features of adopting a core segment which remains mostly elastic and reduced column section (RCS) details around the ends to from a stable hysteretic behavior with large post-yield stiffness and considerable ductility. Several full-scale CMSC components with various length proportions of the RCSs with respect to overall lengths have been experimentally investigated through both far-field and near-fault cyclic loadings followed by fatigue tests. Test results verified that the proposed CMSC provided very ductile hysteretic responses with no strength degradation even beyond the occurrence of the local buckling at the side-segments. The effect of RCS lengths on the seismic performance of the CMSC was verified to relate with the levels of the deformation concentration at the member ends, the local buckling behavior and overall ductility. Estimation equations were established to notionally calculate the first-yield and ultimate strengths of the CMSC and validated by the measured responses. A numerical model of the CMSC was developed to accurately capture the hysteretic performance of the specimens, and was adopted to clarify the effect of the surrounding frame and to perform a parametric study to develop the estimation of the elastic stiffness.

아라미드계 섬유 보강을 통한 RC기둥의 연성과 강도 증진에 대한 실험 연구 (Experimental Study of Ductility and Strength Enhancement for RC Columns Retrofitted with Several Types of Aramid Reinforcements)

  • 이가윤;이동영;박민수;이기학
    • 한국지진공학회논문집
    • /
    • 제27권4호
    • /
    • pp.171-180
    • /
    • 2023
  • This study proposed a seismic reinforcement of RC columns with non-seismic details, a fiber reinforcement method of aramid sheets and MLCP (high elasticity aromatic polyester fiber material) with different characteristics, and 4 full-size column specimens and conducted experiments. The results show that a non-seismic specimen (RC-Orig) rapidly lost its load-bearing capacity after reaching the maximum load, and shear failure occurred. The RC column reinforced with three types of aramid did not show an apparent increase in strength compared to the unreinforced specimen but showed a ductile behavior supporting the load while receiving a lateral displacement at least 1.57 to 1.95 times higher than the unreinforced specimen. The fracture mode of the specimen, according to the application of lateral load, also changed from shear to ductile fracture through aramid-based reinforcement. In addition, when examining the energy dissipation ability of the reinforced specimens, a ductile behavior dissipating seismic energy performed 4 times greater and more stably than the existing specimens.

화재 피해를 입은 고강도 철근 콘크리트 압축부재의 비파괴 검사 (Non destructive test of Fire-damaged reinforced concrete columns with high strength concrete)

  • 서지민;이수진;최은규;신영수;이차돈;권영진
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 추계 학술발표회 제17권2호
    • /
    • pp.13-16
    • /
    • 2005
  • This study is aimed to investigate the strength variation of fire-damaged reinforced concrete column by non-destructive test. It is studied to infer the recovery degree of residual strength of fire-damaged concrete. For measuring the surface hardness of RC columns. Schmidt hammer test is used. Testing is performed three-times: before fire test, directly after fire test and after 20 days.

  • PDF

Effect of load eccentricity on buckling behavior of FRP composite columns with open and closed cross sections

  • M Kasiviswanathan;M Anbarasu
    • Advances in Computational Design
    • /
    • 제8권1호
    • /
    • pp.61-76
    • /
    • 2023
  • Fiber reinforced polymer (FRP) columns are increasingly being used in various engineering fields due to its high strength to weight ratio and corrosion resistance. Being a thin-walled structure, their designs are often governed by buckling.Buckling strength depends on state of stress of elements which is greatly influence by stacking sequence and various inaccuracies such as geometric imperfections and imperfections due to eccentricity of compressive load and non-uniform boundary conditions. In the present work, influence of load eccentricity on buckling strength of FRP column has been investigated by conducting parametric study. Numerical analyses were carried out by using finite element software ABAQUS. The finite element (FE) model was validated using experimental results from the literature, which demonstrated good agreement in terms of failure loads and deformed shapes.The influence of load eccentricity on buckling behavior is discussed with the help of developed graphs.

혼화재료 혼입 콘크리트 강도 차에 따른 건조수축 및 크리프 특성 평가 (Evaluation of Drying Shrinkage and Creep Characteristics by Strength Differences of Concrete Mixed with Admixture)

  • 박동천;송화철
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 봄 학술논문 발표대회
    • /
    • pp.199-200
    • /
    • 2021
  • In the study, creep and dry shrinkage characteristics were evaluated to determine the material properties necessary for structural analysis such as column shortening and differential drying shrinkage. All the experiments were conducted in an constant temperature and humidity room. The mechanical properties as well as the specific creep and ultimate dry shrinkage values were derived. In addition the characteristics of the physical value of the high-strength fiber reinforced concrete were considered.

  • PDF

Structural Design of High-Rise Concrete Condominium with Wall Dampers for Vibration Control

  • Tsushi, Takumi;Ogura, Fumitaka;Uekusa, Masahiro;Kake, Satoshi;Tsuchihashi, Toru;Yasuda, Masaharu;Furuta, Takuya
    • 국제초고층학회논문집
    • /
    • 제8권3호
    • /
    • pp.201-209
    • /
    • 2019
  • This paper presents a structural design of the "(Tentative Name) Toranomon Hills Residential Tower" which is currently under construction in Tokyo. The building is a reinforced concrete high-rise residential complex building with 54 stories above ground, 4 basement levels, and a building height of about 220 m. It is a requirement to provide the highest grade of residence in Japan, and in terms of the structural design, it is required to provide wide and comfortable spaces with high seismic performance. These requirements are satisfied by providing a total of 774 vibration control walls of two types. Also, to further improve the structural performance, steel fibers at the rate of 1.0vol% are provided in the ultra-high strength concrete used in the column members.

고력볼트 스플릿-티 인장접합부의 구조성능에 관한 실험적 연구 (An Experimental Study on the Structural Characteristics of Tension Joints with High-Strength Bolted Split-Tee Connection)

  • 최성모;이성희;김진호
    • 한국강구조학회 논문집
    • /
    • 제16권6호통권73호
    • /
    • pp.737-745
    • /
    • 2004
  • 최근 구조물의 정확한 해석을 위하여 접합부의 강성에 반강접 개념이 도입되고 있다. 우리나라의 경우 반강접 접합부의 실험과 이론해석에 대한 연구가 산발적으로 진행되고 있으며, 체계적인 강구조설계를 진행할 정도의 연구성과를 내지는 못 한 상태이다. 그래서 스플릿-티(Split-Tee)를 이용한 접합부의 설계는 국내의 강종과 하중특성을 고려되지 못한 선진국의 연구자료에 의존하고 있는 실정이다. 본 논문은 F10T 고력볼트를 사용한 스플릿-티 접합부의 반강접 특성을 파악하고자, 기둥-보 접합부에 대한 반강접 연구 이전 단계로서 스플릿-티 인장접합부의 구조성능과 변형특성에 대해 실험을 통하여 규명하고자 한다. 플랜지 두께, 도장, 초기도입축력 및 하중가력패턴을 실험변수로 하였으며, 총 20개의 실험체를 제작하여 300ton UTM으로 인장실험을 수행하였다. 각 변수에 따른 스플릿-티 인장 접합부의 구조성능과 거동을 평가하였다.

100 MPa급 고강도 콘크리트 기둥의 폭렬방지 및 하중지지력 향상방안에 관한 실험적 연구 (Experimental Study for Improving Method of Load Bearing and Spalling Prevention of 100 MPa High Strength Concrete Column)

  • 조범연;김흥열;김형준;권인규;김경옥
    • 한국화재소방학회논문지
    • /
    • 제26권6호
    • /
    • pp.78-84
    • /
    • 2012
  • 본 연구는 100 MPa급 고강도 콘크리트 기둥에 대하여 횡구속력 보강 및 내화보강 공법 적용 유무에 따른 내화성능을 평가하기 위하여 표준화재 재하조건에서 내화실험을 실시하였다. 실험결과, 띠철근을 적용한 실험체의 경우 43분의 내화성능을 만족하여 내화구조로써 적용할 수 없는 것으로 나타났으며, 동일체적비로 띠철근을 대체한 와이어로프를 적용할 경우 별도의 내화처리 없이 69분의 내화성능을 만족하여 4층 이하 건물에 적용할 수 있는 것으로 나타났다. 또한 띠철근을 대체한 와이어로프 및 폭렬방지를 위한 Fiber-Cocktail 혼입공법을 혼합 적용 할 경우 180분의 내화성능을 만족하여 12층 초과 건물에 적용할 수 있는 것으로 나타났다.

편심하중을 받는 건축구조용 고강도 강재(HSA800) 단주의 거동에 관한 실험적 연구 (An Experimental Study on the Structural Behavior of Stub Columns with HSA800 High-strength Steels under Eccentric Loads)

  • 이강민;이명재;오영석;오근영;홍성빈
    • 한국강구조학회 논문집
    • /
    • 제26권4호
    • /
    • pp.289-297
    • /
    • 2014
  • 본 연구에서는 고강도강재(HSA800)의 단주 편심압축실험을 통해 휨-압축 부재의 강도를 평가하였다. 편심압축실험은 축력비에 따라 휨-압축의 조합력을 받는 부재의 P-M 상관관계를 알아보기 위해 HSA800강재의 각형강관과 H형강을 대상으로 실험을 수행하였으며, 가력 편심거리를 조정하여 다양한 P-M 조합에 대해 강도평가 실험을 수행하였다. 실험결과 실험최대 평균응력은 국부좌굴에 의한 최대내력이 결정된 실험체에 대해서는 판폭두께비가 증가함에 따라 감소하는 경향을 보였다. 발현강도의 여유는 축력이 낮을수록 상대적으로 휨강도에 대해 큰 마진을 보이고 있었고, 실험체 모두 현행 설계기준의 P-M 상관관계를 안전측으로 충족하였다.

화재 피해를 입은 고강도 콘크리트 기둥의 보수공법 변화에 따른 내화특성 (Fire Resistance of Repaired High Strength Concrete Column Damaged by Fire)

  • 박천진;백대현;인기호;여인환;민병렬;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2009년도 추계 학술논문 발표대회
    • /
    • pp.113-116
    • /
    • 2009
  • This study analyzed fire-resistant characteristics according to changes in repair methods of PFH mixed high-strength concrete roof structures having undergone fire damage. The results of the study are as follows. First, as a repulsive characteristics of structures, the remaining repulsion was shown to increase following fire-resistance tests according to increases in depth of coverings. The results of the relationship between depth of coverings and remaining repulsion rates following fire-proofing tests showed a high correlation. At a covering depth of 67.3mm, remaining repulsion rate was estimated to be 100%. For fire-resistant characteristics following repairs of structure, as for spalling, severe separation was shown in the case of general plaster while general plaster + Metal Lath showed overall superior spalling prevention. For internal structure temperatures, general plaster showed max temperatures of 705℃, average temperatures of 636℃ while general plaster + metal lath showed max temperature of 660℃ and average temperature of 520℃, demonstrating lower temperature distributions than use of only general plaster. In conclusion, after removing the covering of structures damaged due to high temperatures of fires within high-strength concrete installations, the use of fire-resistant mortars and applying metal laths on surfaces of general plaster will provide superior fire-resistance performance in the occurrence of a 2nd fire.

  • PDF