• 제목/요약/키워드: high speed PWM control

검색결과 213건 처리시간 0.021초

고속응답 전자밸브에 의한 유압 모터계의 PWM 제어 (PWM Control of Hydraulic Motor Systems Using High Speed Solenoid Valves)

  • 김도태
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 1999년도 추계학술대회 논문집 - 한국공작기계학회
    • /
    • pp.387-392
    • /
    • 1999
  • The micro electronic control technology with developing microcomputers make great contribution to electrohydraulic control systems. The electrohydraulic pulse control simplifies in conjunction with power electronic amplifier and high speed operated solenoid valves. It is necessary to valves to convert electronic pulse signal to hydraulic pulse flow as fast as possible. This study deals with the speed control of an oil hydraulic motor operated by two way high speed solenoid valves. The valves acts as converters of electronic-pulse signals to hydraulic power. By constructing systems in which a hydraulic motor is operated by two solenoid valves, the pulse with modulation method (PWM) has adopted as the speed control of hydraulic motor systems. The static and dynamic characteristics of the systems are investigated by the experiment. It is clarify that a hydraulic motor operated PWM show good performance as a control component, achieving accurate velocity control.

  • PDF

고속 PWM을 이용한 MRI 용 전원의 디지털 제어 알고리즘에 관한 연구 (A System on the Digital-Control Algorithm of a High-Speed PWM Power System for MRI System)

  • 허현구;백광렬
    • 제어로봇시스템학회논문지
    • /
    • 제6권3호
    • /
    • pp.235-240
    • /
    • 2000
  • In this paper a digital-control algorithm of a power system suing a high-speed PWM for a MRI system is proposed. The MRI system requires an elaborate ladder-shaped current source. And the load of current source is the inductance with resistance. For the inductive load a voltage output of the power system has hi호 frequency components. Therefore this system requires high-speed PWM above 80KHz, A high speed PWM control algorithm which satisfies those conditions is designed. Finally the performance of proposed control algorithm is shown by simulation.

  • PDF

고속 전자밸브 PWM제어에 의한 유압구동식 선박용 축발전장치의 정속제어 (Constant Speed Control of Shaft Generating System Driven by Hydrostatic Transmission Using a PWM Controlled High Speed on/off Valve for Ship Use)

  • 정용길;신민수;이일영
    • 대한기계학회논문집
    • /
    • 제18권6호
    • /
    • pp.1374-1381
    • /
    • 1994
  • This study suggests a new type shaft generating system driven by hydrostatic transmission suitable for small size vessels. In this system, the hydraulic motor speed is controlled by displacement adjustment using a 3-way high speed on/off valve. The 3-way high speed valve is operated by PWM control signal. In this study, a digital robust servo control algorithm is applied to the controller design of the system. By experiments and numerical computations, the frequency variation characteristics of the generating system under various disturbances are investigated. Conclusively, it is said that the shaft generating system proposed in this study shows excellent control performances.

PWM 제어용 고속 전자석의 특성에 관한 연구 (A Study on Characteristics of High Speed Solenoid for PWM Control)

  • 강보식;윤소남;성백주;김형의
    • 연구논문집
    • /
    • 통권27호
    • /
    • pp.141-151
    • /
    • 1997
  • Recently, the importance of electro-multifunction control valve which is digital control valve is increasing day after day. This is due to the demand of that the current industrial world wants the valve having simpler control circuit and higher operation reliability. It is the PWM controlled high speed electronic valve that satisfies the damands of current industrial world. But, the PWM controlled high speed electronic valve has some non-linearity characteristics like as the delay time of switching and the pressure oscillation phenomenon. These characteristics are an obstacle for the control of high speed & high efficiency in control system. Therefore, in this study, we set the studying purpose on analysis of parameter characteristics in solenoid, and on establishment of optimum design technique in high speed solenoid.

  • PDF

고속전자밸브를 사용한 유압장치의 PWM 제어에 관한 연구 (A Study on the PWM Control of Hydraulic Equipment Using High Speed On-Off Valve)

  • 허준영
    • 대한기계학회논문집
    • /
    • 제19권3호
    • /
    • pp.868-876
    • /
    • 1995
  • This study deals with a position control of an electro-hydraulic servo system which consist of cylinder and high speed on-off valves operated by microcomputer. The merits of PWM control of hydraulic equipment are the robustness of the high spee on-off valve, its low price and the direct control without D/A converter. In the PWM control of high speed on-off valve, the time lag and switching time existing between the input and output signals of valve are considered as demerit points. To get analytical results, the effects of these demerits have to be clarified in detail. The object of this study is to propose a mathematical model for the behavior of high speed on-off valve and to get analytical results of this system. The dynamic characteristics of this system is examined by digital computer simulation analytically and compared with experimental results to varify the proposed mathematical model.

PWM 제어되는 유압장치의 안정성 해석 (A Study Stability Analysis of a PWM Controlled Hydraulic Equipment)

  • 허준영
    • 대한기계학회논문집
    • /
    • 제19권6호
    • /
    • pp.1469-1478
    • /
    • 1995
  • PWM control is a kind of nonlinear control. The merits of PWM control of hydraulic equipment are the robustness of the high speed on-off valve and its low price. And it is easily implemented to hydraulic equipments with microcomputer. The high speed on-off valve is directly digitally controlled without any D/A converter. The objectives of this study is to analyze the limit cycle which regularly appear in the position control system using high speed on-off valve, and to give a criterion for the stability of this system. To do this, the nonlinear characteristics of PWM and cylinder friction of this system are described by harmonic linearization and the effects of parameter variations to the system stability are examined theoretically and experimentally. Consequently, the availability of the proposed method is confirmed well.

고속전자밸브로 제어되는 전기.유압 서보시스템의 특성 개선에 관한 연구 (A Study on the Characteristics Improvement of Electro-Hydraulic Servo System Controlled by High Speed Solenoid Valve)

  • 박성환;이진걸
    • 제어로봇시스템학회논문지
    • /
    • 제7권4호
    • /
    • pp.288-294
    • /
    • 2001
  • In this study, a new PWM method considering the actuation delay of high speed solenoid valves is proposed to improve the response characteristics of electro hydraulic servo systems controlled by high speed solenoid valves. In addition, the decision method for the system gain, the basic period of PWM, and the sampling time is proposed, Since the conventional system controlled by high speed solenoid valves is too slow to apply this method, a high speed driving circuit(Quick-Drive) which enables rapid switching of the high speed solenoid valve at a high speed sampling mode is applied to realize this method. The experimental result shows that it is possible to achieve precision and quiet control without occurrence of limit cycle and wide range dead band.

  • PDF

고속전자밸브를 이용한 유압실린더의 PWM 제어에 관한 연구 (A Study on PWM Control of Hydraulic Cylinder Using High Speed Solenoid Valve)

  • Park, S.H.;Lee, J.K.
    • 한국정밀공학회지
    • /
    • 제12권7호
    • /
    • pp.138-147
    • /
    • 1995
  • The conventional PWM method, which was used in controlling the on-off valve, such as high-speed solenoid valve, was modulating the width of the pulse applied to the valve, by selecting arbitrary sampling time and modulating the duty-ratio in proportion to the error. However, in this method, a selection of long sampling time was inevitable and it was unable to get a high accuracy and a quick response. This study is for designing an appropriate controller for high-speed solenoid valve by proposing an improved duty-ratio modulation method using the Saw-toothed Carrier Wave which enables a short sampling time selection, high accuracy of control, and a quick response. Test which was carried out in the laboratory shows that transient and steady state response could be improved by PID controller.

  • PDF

PWM 제어 고속 온-오프 전자밸브에서 발생하는 압력맥동 저감 (Pressure Ripple Reduction in High Speed On-Off Solenoid Valves Driven by PWM Control)

  • 김도태;이상권
    • 유공압시스템학회논문집
    • /
    • 제2권2호
    • /
    • pp.8-13
    • /
    • 2005
  • This paper investigates a fast, accurate and inexpensive hydraulic motor speed control system using high speed on-off solenoid valves. In order to retain the advantages of the two position valve and obtain better performance, the valves are operated by pulse width modulation(PWM) control. PWM signal is generated from a LabWIEW program in microcomputer in order to set up various duty ratio and frequency of carrier wave in PWM signal with varying system parameters. As the results of experiments, the speed control of a hydraulic motor was successfully implemented using on-off solenoid valves. In order to attenuate the pressure ripple and speed variation due to discontinuously controlled flow through the on-off valves, a resonator hose fabricated for automobile power steering system was connected between the valve and a hydraulic motor. From experimental results obtained in the hydraulic motor system with a resonator hose, it was ascertained that the resonator hose showed excellent performances in reducing pressure ripple and motor speed variation.

  • PDF

전압형 PWM 인버터 제어 고속 엘리베이터 시스템 (High-Speed Elevator Controlled by Voltage-Type PWM Inverter)

  • 김운수;장철호;이제필;김정하;엄용기;송승봉
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 B
    • /
    • pp.1206-1210
    • /
    • 1992
  • To satisfy the requirements of a stable speed control, comfortable ride and precise landing in the high-speed elevator. The induction motor driving elevator is controlled by inverter using vector control method which calculates optimum torque to apply to the Induction motor. This paper describes the control system of high-speed elevator that consists of the voltage-type PWM converter with an unity input power factor and sinusoidal input current and the voltage-type PWM inverter with a precise speed control and sinusoidal output current. The test results of actual elevator are presented.

  • PDF