• Title/Summary/Keyword: high power factor

Search Result 1,907, Processing Time 0.029 seconds

The Single Phase Converter of Power Factor Collection Type with Simple Switching Method (간이 스위칭법에 의한 단상 역률개선형 컨버터)

  • 문경희;고강훈;김은수;곽동걸;조판제;이현우
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.323-326
    • /
    • 1999
  • For decrease the harmonic current components of the power source, a first method is insert the choke coil that used the choke input type rectifier, the booster chopper circuit and buck chopper circuit. And the several method are studying like as the PWM(Pulse Width Modulation) converter and the active filter type which is used the high frequency switching and the sinusoidal wave formed input current. In this type, there are many problem as a low efficiency, increased the noise, the high leakage current and cost up by the high frequency switching. For improve this problems, the partial resonan method is used on the booster inducter and lossles snubber condenser. This method decreased the distortion factor has lower harmonic components than the hard switching and there is no switching loss by the ZCS(Zero Current Switching) at switch turn-on and the ZVS(Zero Voltage Swithcing) at switch turn-off

  • PDF

A High Efficiency Single-Phase AC-DC Boost Converter for Power Factor Correction (역률개선을 위한 고효율 교류-직류 승압형 변환기)

  • Park, Hae-Dong;Yoon, Duck-Yong;Hong, Soon-Chan
    • Proceedings of the KIEE Conference
    • /
    • 1998.11a
    • /
    • pp.117-120
    • /
    • 1998
  • This paper proposes a new high efficiency single-phase AC-DC boost converter for power factor correction. Lossless commutation circuit is interposed in the proposed converter for soft-switching. Due to this commutation circuit, the converter operates in 9 mode. In spite of changing input voltage and load, It attracts a constant DC output voltage because of the PWM control scheme using both the output voltage feedback and the input voltage feedforward. The converter is suitable for high power applications and operates in continuous conduction mode. In this paper, a 2.4[kW] converter is designed and simulated.

  • PDF

Utility Interactive Photovoltaic Generation System using PWM Current Source Inverter (PWM 전류형인버터를 이용한 계통연계형 태양광 발전시스템)

  • 박춘우;성낙규;이승환;강승욱;이훈구;한경희
    • Proceedings of the KIPE Conference
    • /
    • 1996.06a
    • /
    • pp.109-112
    • /
    • 1996
  • In this paper, we composed utility interactive photovoltaic generation system of current source inverter, and controlled that low harmonic and high power factor are hold by supposing control and compensation method which is concerned with synchronous signal distortion and modulation delay. And we put parallel resonant circuit into dc link, so, magnitude of direct reactance was reduce by restraining direct current pulsation which had accumulation of pulsating power in alternating electrolytic condenser. Also we controlled that modulation factor is operated around maximum output of solar cell.

  • PDF

Characteristics analysis of PFC boost converter with soft switching for harmonics reduction (고조파 저감을 위한 소프트 스위칭 승압형 PFC컨버터의 특성해석)

  • 김봉규
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.150-154
    • /
    • 2000
  • This paper proposes PFC boost converter with soft switching for harmonics decrement and analyzes characteristics of PFC boost converter. In this technique power factor correction(PFC) is usually obtained by operating the PFC stage in the discontinuous current mode(DCM) Switching devices are operated for reducing current stress and electronical noise. As a result eliminate 3rd harmonic component and high power factor(PF) of the input line are verified by characteristics analysis and experimental results.

  • PDF

SMALL-SIGNAL MODEL FOR A CONTROLLED ON-TIME BOOST POWER FACTOR CORRECTION CIRCUIT

  • Kang, Yonghan;Choi, Byungcho
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.642-647
    • /
    • 1998
  • A new small-signal model for the controlled on-time boost power factor correction (PFC) circuit is presented. The proposed small-signal model is valid up to high frequencies over lKHz. The model can be used in designing the voltage feedback compensation of PFC circuits, the control bandwidth of which is maximized with auxiliary means of removing the low-frequency ripple from the output. The accuracy of the model is confirmed by a 200W experimental hardware

  • PDF

Novel Control Range Compensation Method in Power Factor Correction Circuit

  • Park, Youngbae;Cho, Donghye
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.224-225
    • /
    • 2012
  • When Power Factor Correction(PFC) boost converter is designed for the universal input range, unwanted burst operation can be found at high line and light load. This operation may cause an audible noise from the boost inductor or sensitive flicker for human eye can be found in case of the display application. In order to solve this difficulty, this paper proposes the new control range compensation method and shows the effectiveness than the conventional method thru the experimental result.

  • PDF

PRACTICAL EVALUATIONS OF PARASITIC RESONANT PWM DC-DC CONVERTERS FOR HIGH-POWER MEDICAL USE

  • H. Takano;J. Takahashi;Sun, J.M.;L... Gamage;M. Nakaoka
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.701-708
    • /
    • 1998
  • This paper presents a novel non-resonant PWM DC-DC converter for X-ray high-voltage power generator using the parasitic impedances of the high-voltage high-frequency link transformer with its output high-voltage control scheme and steady-state characteristics compared to the conventional series-parallel resonant DC-DC converter. The key point of this approach is to evaluate effectiveness of reduction of the turn ratio of the high-voltage high-frequency transformer on improvements in power conversion efficiency and the power factor applying a boost AC-DC converter as DC voltage source, especially in the long exposure term and light output load ranges.

  • PDF

A calibration of high current measuring sensors by comparison tests (비교 시험에 따른 대전류 측정 센서 교정 결과 분석)

  • Han, Jong-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.312-313
    • /
    • 2015
  • For the traceability of high current measuring sensors of high power testing department II(HPTD II) in Korea Electrotechnology Research Institute(KERI), additional comparison tests with reference test object were performed repeatedly. The first intercomparison has been carried out between the reference shunt for Asia and high current shunt of HPTD II in 2013. This paper compares the test results of the calibration in 2014 with them in 2015. The assigned new scale factor of high current sensors will be applied to high power tests in HPTD II until the next high current intercomparison.

  • PDF

A Soft switching method for Loss reduction of Inverter (인버터의 손실저감을 위한 소프트 스위칭기법)

  • 곽동걸;김영철;이현우
    • Proceedings of the IEEK Conference
    • /
    • 2001.06e
    • /
    • pp.249-252
    • /
    • 2001
  • A large number of soft switching topologies included a resonant circuit have been proposed. But these circuits increase number of switch in circuit and complicate sequence of switching operation. In this Paper, the authors propose power conversion system, DC-AC inverter of high efficiency and high power factor with soft switching mode by partial resonant method. The result is that the switching loss is very low and the efficiency of system is high. And the snubber condenser used in partial resonant circuit makes charging energy regenerated at input power source for resonant operation.

  • PDF

High Power Factor Single-Phase Active Rectifier for Inverter Air-Conditioner (인버터 에어컨을 위한 고역률 단상능동정류기)

  • 정용채;권경안
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.2
    • /
    • pp.144-151
    • /
    • 1999
  • 본 논문에서는 IEC 61000-3-2와 같은 고조파 전류 국제규제에 만족하기 위해서 인버터 에어컨을 위한 고역률 단상능동정류가(SAR) [4-6]를 적용하였다. 입력전류의 왜곡을 최소화하고 FA5331, UC3854, ML4821 등과 같은 제어IC를 적용하기 위해서 입력전압 및 전류에 대한 새롭고 적절한 검출회로를 제안하였다. 효율 및 가격의 관점에서 SAR를 인버터 에어컨에 적용하기 위한 두가지 방법이 있다. 이런 두가지 방식에 대해서 수동소자의 선정방법을 제시하였다. 결정된 소자들을 사용하여 SAR 효율의 증가 여부를 확인하기 위해서 손실분석을 행하였다. 3kW급의 이러한 두가지 방식에 대한 프로트형 SAR회로를 제작하고 실험결과를 통해서 역률제어능력을 갖는 회로의 동작과 성능을 확인하였다.

  • PDF