• Title/Summary/Keyword: high loaded paper

Search Result 199, Processing Time 0.031 seconds

A Dual-Band Compact Folded Patch Antenna (이중 대역 소형 평면 패치 안테나)

  • 김태영;정종호;박동국;박익모
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.1
    • /
    • pp.47-53
    • /
    • 2003
  • In this paper we proposed a novel dual-band compact folded patch antenna with the same linear polarizations and high isolation characteristic between the two frequency range. The antenna is loaded with a high permittivity dielectric material in order to reduce the antenna size and open circuit stubs are used in order to broaden the bandwidth. The fractional bandwidths of the optimized antenna with demensions 4 mm${\times}$3 mm${\times}$5 mm are 3.0 % at 5.6 GHz band and 2.8 % at 5.8 GHz band, respectively. The isolation characteristic between the two ports is less than -26 dB within the operating frequency range.

An Efficient Dynamic Load Distribution for the Web Cluster Systems (웹 클러스터 시스템의 효율적인 동적 작업분배)

  • Seo, Kyung-Ryong
    • Journal of Korea Multimedia Society
    • /
    • v.7 no.8
    • /
    • pp.1097-1106
    • /
    • 2004
  • The typical web cluster architecture consists of replicated real servers and a virtual server that routes client requests among the real servers. In this paper, we proposed an efficient dynamic load distribution method with load prediction for the web cluster systems. The virtual server transmit status request message to real servers in other to get load states. However the load states dose not accurate during load distribution, thus the virtual server predict the load status of real servers and assign a request of the client to the minimum loaded real server. The proposed distribution methods works not related to partial breakdown of real servers, thus the system works with high availability. We also show that the proposed distribution method preserve scalable property and improve the throughput through a set of simulations.

  • PDF

A Study on Optimization of Tooth Micro-geometry for a Helical Gear Pair (헬리컬 기어의 치형최적화에 관한 연구)

  • Zhang, Qi;Kang, Jae-Hwa;Lyu, Sung-Ki
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.10 no.4
    • /
    • pp.70-75
    • /
    • 2011
  • Nowadays, modern gearboxes are characterized by high torque load demands, low running noise and compact design. Also durability of gearbox is specially a major issue for the industry. For the gearbox which used in wind turbine, gear transmission error(T.E.) is the excitation that leads the tonal noise known as gear whine, and radiated gear whine is also the dominant source of noise in the whole gearbox. In this paper, tooth modification for the high speed stage is used to compensate for the deformation of the teeth due to load and to ensure a proper meshing to achieve an optimized tooth contact pattern. The gearbox is firstly modeled in Romax software, and then the various combination analysis of the tooth modification is presented by using Windows LDP software, and the prediction of transmission error under the loaded torque for the helical gear pair is investigated, the transmission error, contact stress, root stress and load distribution are also calculated and compared before and after tooth modification under one torque condition. The simulation result shows that the transmission error and stress under the loads can be minimized by the appropriate tooth modification.

Influence of Concrete Strength on Tension Stiffening (콘크리트강도가 인장증강에 미치는 영향에 관한 연구)

  • Yum, Hwan-Seok;Yun, Sung-Ho;Kim, Woo
    • Journal of the Korea Concrete Institute
    • /
    • v.12 no.1
    • /
    • pp.13-22
    • /
    • 2000
  • This paper describes the results obtained from 11 direct tension tests to explore the influence of concrete strength on tension stiffening behavior in reinforced concrete axial members. Three different concrete compressive strengths, 250, 650, and 900kgf/$\textrm{cm}^2$, were included as a main variable, while the ratio of cover thickness-to-rebar diameter was kept constant to be 2.62 to prevent from splitting cracking. As the results, it was appeared that, as higher concrete strength was used, less tension stiffening effect was resulted, and the residual deformation upon unloading was larger. In addition, the spacing between adjacent transverse cracks became smaller with higher concrete strength. The major cause for those results may be attributed to the fact that nonuniform bond stress concentration at both loaded ends and crack sections becomes severer as higher concrete is used, thereby local bond failure becomes more susceptible. From these findings, it would be said the increase in flexural stiffness resulting from using high-strength concrete will be much smaller than that predicted by the conventional knowledge. Finally, a factor accunting for concrete strength was introduced to take account for the effect of HSC on tension stiffening. This proposed equation predicts well the tension stiffening for the effect of HSC on tension stiffening. This proposed equation predicts well the tension stiffening behavior of these tests.

Design of a High Efficiency Neon Transformer with Abnormal Load Interrupting Circuit (부하측 이상 검출 차단 장치를 내장한 고효율 자기식 네온 변압기의 설계)

  • Byun Jei-Young;Kim Yoon-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.723-726
    • /
    • 2002
  • In this paper, a high efficiency leakage transformer for neon tube is developed to improve its power factor, to reduce its core loss and weight by using a technique of shape optimization and direction of grain-oriented silicon steel sheet. A protection circuit is designed for all types of neon transformer loaded with one or more neon lamps. Whenever the neon tube fails to be started up or comes to the life end, or encounters faults with open-circuits at the output terminals of the neon transformer, the protection circuit will be initiated to avoid more critical hazards. These neon transformers need a protection circuit to prevent from current stresses on circuit components by neon tube fail. The input of the transformer is automatically cut off when the abnormal condition occurs, preventing waste of no-load power. As the results of the study, the core weight is reduced by $11\%$, the power factor improved by $5\%$ and the efficiency increased by $6\%$ compared with the conventional type due to the employment of the grain-oriented steel sl)eel and the optimized core shape.

  • PDF

The Separation and Recovery of Nickel and Lithium from the Sulfate Leach Liquor of Spent Lithium Ion Batteries using PC-88A

  • Nguyen, Viet Tu;Lee, Jae-Chun;Jeong, Jinki;Kim, Byung-Su;Pandey, B.D.
    • Korean Chemical Engineering Research
    • /
    • v.53 no.2
    • /
    • pp.137-144
    • /
    • 2015
  • The present paper deals with the extractive separation and selective recovery of nickel and lithium from the sulfate leachate of cathode scrap generated during the manufacture of LIBs. The conditions for extraction, scrubbing and stripping of nickel from lithium were optimized with an aqueous feed containing $2.54kg{\cdot}m^{-3}$ Ni and $4.82kg{\cdot}m^{-3}$ Li using PC-88A. Over 99.6% nickel was extracted with $0.15kmol{\cdot}m^{-3}$ PC-88A in two counter-current stages at O/A=1 and pH=6.5. Effective scrubbing Li from loaded organic was systematically studied with a dilute $Na_2CO_3$ solution ($0.10kmol{\cdot}m^{-3}$). The McCabe-Thiele diagram suggests two counter-current scrubbing stages are required at O/A=2/3 to yield lithium-scrubbing efficiency of 99.6%. The proposed process showed advantages of simplicity, and high purity (99.9%) nickel sulfate recovery along with lithium to ensure the complete recycling of the waste from LIBs manufacturing process.

A Study on Commercial Frequency Source with High Frequency Resonant Type using ZCS (ZCS를 이용한 고주파 공진형 상용주파수 전원에 관한 연구)

  • Kim, Jong-Hae;Kim, Dong-Hui;No, Chae-Gyun;Gu, Tae-Geun;Bae, Sang-Jun;Lee, Bong-Seop
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.8
    • /
    • pp.448-454
    • /
    • 1999
  • This paper describes a new dc-ac inverter system which for achieving sinusoidal ac waveform makes use of parallel loaded high frequency resonant inverter consisting of full bridge. Each one of the pair of switches in the inverter is driven to synchronous output frequency and the other is driven to PWM signal with resonant frequency proportional to magnitude of sine wave. A forced discontinuous conduction mode is used to realize the quasi-sinusoidal pulse in each switching period. Therefore the inverter generates sinusoidal modulated output voltage including carrier frequency that is resonant frequency. Carrier frequency components of modulated output voltage is filtered by low pass filter. Since current through switches is always zero at its turn-on in the proposed inverter, low stress and low switching loss is achieved. Operating characteristics of the proposed system is analyzed in per unit system using computer simulation. The output voltage of if includes low harmonics and it is almost close to sine wave. Also, the theoretical analysis is proved through the experimental test.

  • PDF

The Analysis of a Coaxial-to-Waveguide Transition Using FDTD with Cylindrical to Rectangular Cell Interpolation Scheme

  • Yu, Kyung-Wan;Kang, Sung-Choon;Kang, Hee-Jin;Choi, Jae-Hoon;Kim, Jin-Dae
    • ETRI Journal
    • /
    • v.21 no.2
    • /
    • pp.1-8
    • /
    • 1999
  • We analyze the characteristics of a coaxial-to-waveguide transition based on the finite difference time domain (FDTD) method with the cylindrical to rectangular cell interpolation scheme. The scheme presented in this paper is well suited for the analysis of a microwave device with a probe near waveguide discontinuity because perfect TEM mode can be generated inside the coaxial cable by using the cylindrical cell. The scattering parameters of a designed Ka-band transition are evaluated and compared with those of commercially available software, High Frequency Structure analysis Simulator (HFSS) and measured data. There exists good agreement between the measured and calculated data. In order to prove an accuracy of the interpolation scheme, a coaxial to waveguide transition with a disk-loaded probe is analyzed by the present approach and the results of this analysis are compared with measured data. Comparison shows that our results match very closely to those of measurement and other approaches. The method presented in this paper can be applied to analyze the characteristics of a probe excited cavity, coaxial waveguide T-Junctions, and so on.

  • PDF

Study on the Prevention of Pad Fluttering with the Variation of Preload in a Tilting Pad Journal Bearing (예압 변경을 통한 틸팅패드 저널베어링의 패드 Fluttering 방지에 관한 연구)

  • 박철현;김재실;하현천;양승헌
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.4
    • /
    • pp.344-351
    • /
    • 2004
  • Tilling pad journal bearings have been widely used to support the rotors of the high rotating machinery such as steam and gas turbines owing to their inherent dynamic stability characteristics. However, serious bearing problems such as fatigue damage in the upper unloaded pad, the break of locking pins and the wear of pinholes etc. by pad fluttering are frequently taken place in the actual steam turbines. The purpose of this paper is to investigate the mechanism of pad fluttering and to suggest the useful design guideline(application of preload, m) for the purpose of preventing bearing problems by pad fluttering in a tilting pad journal bearing. It is estimated that upper pad is easy to flutter because the film shape of the upper pad is diverged by moment acting on pivot point. This paper suggests that effective preload range(m $\geq$ 0.5) in order to be statically loaded pad under all operating conditions. Also, design modified bearing is suggested for the adjustment in actual steam turbines. And bearing and rotor dynamic analysis are performed to identify bearing characteristics and to verify the reliability of rotor-bearing system.

A load-bearing structural element with energy dissipation capability under harmonic excitation

  • Pontecorvo, Michael E.;Barbarino, Silvestro;Gandhi, Farhan S.;Bland, Scott;Snyder, Robert;Kudva, Jay;White, Edward V.
    • Advances in aircraft and spacecraft science
    • /
    • v.2 no.3
    • /
    • pp.345-365
    • /
    • 2015
  • This paper focuses on the design, fabrication, testing and analysis of a novel load-bearing element with energy dissipation capability. A single element comprises two von-Mises trusses (VMTs), which are sandwiched between two plates and connected to dashpots that stroke as the VMTs cycle between stable equilibrium states. The elements can be assembled in-plane to form a large plate-like structure or stacked with different properties in each layer for improved load-adaptability. Also introduced in the elements are pre-loaded springs (PLSs) that provide high initial stiffness and allow the element to carry a static load even when the VMTs cannot under harmonic disturbance input. Simulations of the system behavior using the Simscape environment show good overall correlation with test data. Good energy dissipation capability is observed over a frequency range from 0.1 Hz to 2 Hz. The test and simulation results show that a two layer prototype, having one soft VMT layer and one stiff VMT layer, can provide good energy dissipation over a decade of variation in harmonic load amplitude, while retaining the ability to carry static load due to the PLSs. The paper discusses how system design parameter changes affect the static load capability and the hysteresis behavior.