• 제목/요약/키워드: high linearity

검색결과 1,060건 처리시간 0.029초

Development of Diode Based High Energy X-ray Spatial Dose Distribution Measuring Device

  • Lee, Jeonghee;Kim, Ikhyun;Park, Jong-Won;Lim, Yong-Kon;Moon, Myungkook;Lee, Sangheon;Lim, Chang Hwy
    • Journal of Radiation Protection and Research
    • /
    • 제43권3호
    • /
    • pp.97-106
    • /
    • 2018
  • Background: A cargo container scanner using a high-energy X-ray generates a fan beam X-ray to acquire a transmitted image. Because the generated X-rays by LINAC may affect the image quality and radiation protection of the system, it is necessary to acquire accurate information about the generated X-ray beam distribution. In this paper, a diode-based multi-channel spatial dose measuring device for measuring the X-ray dose distribution developed for measuring the high energy X-ray beam distribution of the container scanner is described. Materials and Methods: The developed high-energy X-ray spatial dose distribution measuring device can measure the spatial distribution of X-rays using 128 diode-based X-ray sensors. And precise measurement of the beam distribution is possible through automatic positioning in the vertical and horizontal directions. The response characteristics of the measurement system were evaluated by comparing the signal gain difference of each pixel, response linearity according to X-ray incident dose change, evaluation of resolution, and measurement of two-dimensional spatial beam distribution. Results and Discussion: As a result, it was found that the difference between the maximum value and the minimum value of the response signal according to the incident position showed a difference of about 10%, and the response signal was linearly increased. And it has been confirmed that high-resolution and two-dimensional measurements are possible. Conclusion: The developed X-ray spatial dose measuring device was evaluated as suitable for dose measurement of high energy X-ray through confirmation of linearity of response signal, spatial uniformity, high resolution measuring ability and ability to measure spatial dose. We will perform precise measurement of the X-ray beamline in the container scanning system using the X-ray spatial dose distribution measuring device developed through this research.

자속경로 단면적 및 공극변화를 이용한 인던턴스형 초정밀 변위측정 시스템 (A Comparative Study of a Variable Overlap-area Type and Conventional Types in the Inductive Precision Position Measurement System)

  • 최동준;최인묵;김수현
    • 대한기계학회논문집A
    • /
    • 제26권2호
    • /
    • pp.254-259
    • /
    • 2002
  • A variable air-gap type system is widely used for inductive precision position measurement systems. This type transducer has high sensitivity but lacks a linear measurement range due to structural nonlinearity. Furthermore, as measurement range increases, linearity error is also increased. The alternative is a variable overlap-area type system. The sensitivity of this type is determined by the initial air-gap dimension, keeps the original value and does not deteriorate linearity in spite of the variations of the measuring range.

스포츠웨어용 투습발수직물의 마찰음과 관련 역학적 성질 비교 (Frictional Sounds and Its Related Mechanical Properties of Vapor Permeable Water Repellent Fabrics for Active Wear)

  • 조길수;박미란
    • 한국감성과학회:학술대회논문집
    • /
    • 한국감성과학회 2003년도 춘계학술대회 논문집
    • /
    • pp.8-13
    • /
    • 2003
  • Frictional sound of 13 vapor permeable water repellent fabric by sound generator were recorded and analysed through FFT analysis. The frictional Sounds were quantified by calculating total sound pressure(LPT), the level range ΔL and the frequency difference Δf. Mechanical properties were measured by KES-FB. LPT values of specimens finished wet coating were higher than those of dry coating. Values for bending rigidity, shear stiffness, surface roughness and compressional recovery of polyurethane fabrics increased compared with the cire finished fabrics. Laminated fabrics had high values of frictional coefficient and low values of surface roughness. LPT showed significant correlation with compressional energy, weight and thickness. (ΔL) was highly correlated with compressional linearity, frictional coefficient, compressional recovery, and (Δf) with tensile linearity, compressional energy, thickness, and weight.

  • PDF

슬라이딩모드 제어기를 이용한 공기압 실린더 구동장치의 강인제어 (Robust Control of Pneumatic Cylinder Driving System using Sliding Mode Controller)

  • 장지성;한승훈
    • 동력기계공학회지
    • /
    • 제21권6호
    • /
    • pp.101-109
    • /
    • 2017
  • The pneumatic driving system has advantages such as high output power per weight and low heat generation rate. However, it is difficult to control the position because of its strong non-linearity such as large friction forces compared to driving force, and heat transfer characteristics that change during operation. Therefore, in order to achieve the control objectives, a robust controller should be designed considering modeling error and model uncertainty. In this paper, a sliding mode controller is designed to improve the position control performance of pneumatic cylinder driving system. Experimental results show that the designed controller achieves the designed control objectives even if the model of the cylinder driving system, such as the initial pressure inside the cylinder and the initial position of the piston is changed.

Comparison of Spectral Data of Metabolites Collected from Bruker and Varian 600 MHz Spectrometers

  • Kang, Woo-Young;Chae, Young-Kee
    • 한국자기공명학회논문지
    • /
    • 제13권1호
    • /
    • pp.7-14
    • /
    • 2009
  • The spectral data were collected from the two 600 MHz spectrometers from the two major manufacturers, Broker and Varian. The samples were prepared to create standard curves for quantitative measurements of metabolite concentrations. Instead of employing one-dimensional $^1H$ experiments, the two-dimensional $^1H-^{13}C$ HSQC experiments were performed for better separation of resonances. For some resonances, the high salt condition hindered the linear correlation between the intensity and actual metabolite concentration. Excluding overlapped ones, most resonances showed good linearity. Although the Varian spectrometer showed better linearity, both spectrometers were able to generate acceptable standard curves. From this data, we could identify resonances that could be used to better quantify the concentrations of the particular metabolites. With these standard curves, the quantitative measurements of the metabolites from the real samples will be facilitated.

Feedback Loop Design for Micro Gyroscope

  • Sung, Woon-Tahk;Song, Jin-Woo;Lee, Jang-Gyu;Taesam Kang
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2002년도 ICCAS
    • /
    • pp.39.4-39
    • /
    • 2002
  • This paper presents a design and implementation of a PID feedback control loop for micro gyroscope. The feedback control loop improves the gyroscope performance such as linearity, bandwidth, and bias stability for micro gyroscope which is basically a high-Q system and exhibits a low performance with an open loop control. The designed and implemented feed-back control loop is applied to the SNU-Bosch MEMS gyroscope to demonstrate the improvement with the feedback control loop. The bandwidth is improved to 60Hz from 25Hz of open loop control. The linearity becomes 0.5% from 1%. The bias stability is improved to 0.03 deg/sec from 0.06 deg/sec.

  • PDF

고속회전체의 진동 측정용 비접촉 광섬유 변위센서 개발 (Development of Optical Fiber Displacement Sensor for Non-contact Vibration Measurement in the High Speed Rotation System)

  • 이기석;홍준희;신우철
    • 한국정밀공학회지
    • /
    • 제22권8호
    • /
    • pp.50-56
    • /
    • 2005
  • This paper is described a development of an optical fiber displacement sensor. The optical fiber sensor using an intensity modulated measures the displacement between target and sensor. A prototype sensor is composed of a transmitting part, a receiving part and a signal processing circuit. The experiment was conducted not only the sensor performance but also factors that affect intensity. The main performance of this sensor is resolution of 0.37um and the non-linearity $0.7\%$ FS and the dynamic bandwidth of about 6.3kHz. As a result of rotation test, the prototype sensor showed an equivalent performance to a commercial eddy current sensor.

폴리에스테르 경편포의 신장특성에 관한 연구 (A Study on the Tensile Properties of Polyester Warp Knitted Fabrics)

  • 김석근;최재우;남은우
    • 한국염색가공학회지
    • /
    • 제12권1호
    • /
    • pp.17-24
    • /
    • 2000
  • The tensile properties of polyester warp knitted fabrics of satin and reverse satin structure with various lengths of underlap were studied. In the range of low tension, the satin warp knitted fabric showed larger tensile energy and elongation in the direction of $0^\circ$ and larger tensile linearity, tensile resilience and initial modulus in $90^\circ$. Meanwhile, reverse satin one showed larger initial moduli in 0$^{\circ}$ and larger the others in $90^\circ$. In the range of high tension, the tendencies of both fabrics in $0^\circ$ direction were almost the same as those in all direction. As the under laps were shorter for both fabrics, tensile linearity, tensile energy and elongation increased, but tensile resilience decreased in all directions. However initial moduli were changed little.

  • PDF

Integratable Micro-Doherty Transmitter

  • Lee, Jae-Ho;Kim, Do-Hyung;Burm, Jin-Wook;Park, Jin-Soo
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제6권4호
    • /
    • pp.275-280
    • /
    • 2006
  • We propose Doherty power amplifier structure which can be integrated in Silicon RF ICs. Doherty power amplifiers are widely used in RF transmitters, because of their high Power Added Efficiency (PAE) and good linearity. In this paper, it is proposed that a method to replace the quarter wavelength coupler with IQ up-conversion mixers to achieve 90 degree phase shift, which allows on-chip Doherty amplifier. This idea is implemented and manufactured in CMOS 5 GHz band direct-conversion RF transmitter. We measured a 3dB improvement output RF power and linearity.