• 제목/요약/키워드: high frequency moisture sensor

검색결과 14건 처리시간 0.033초

고주파 수분 센서를 이용한 모르타르의 단위수량 평가에 관한 실험적 연구 (An Experimental Study on the Evaluation of Unit-Water Content in Mortar Using High Frequency Moisture Sensor)

  • 조양제;유승환;양현민;윤종완;박태준;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 봄 학술논문 발표대회
    • /
    • pp.17-18
    • /
    • 2021
  • The unit-water content of concrete is one of the important factors in determining the quality of concrete and is directly related to the durability of the construction structure, and the current method of measuring the unit-water content of concrete is applied by the Air Meta Act and the Electrostatic Capacity Act. However, there are complex and time-consuming problems with measurement methods. Therefore, high frequency moisture sensor was used for quick and high measurement, and unit-water content of mortar was evaluated through machine running and deep running based on measurement big data.

  • PDF

고주파 수분 센서를 이용한 시멘트 모르타르의 단위수량 측정에 관한 기초적 연구 (An Fundamental Study on the Measurement of Cement Mortar Unit-Water Content Using High Frequency Moisture Sensor)

  • 조양제;김민서;윤종완;박태준;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2020년도 가을 학술논문 발표대회
    • /
    • pp.6-7
    • /
    • 2020
  • The unit-water content of concrete is one of the important factors in determining the quality of concrete and is directly related to the durability of the construction structure, and the current method of measuring the unit-water content of concrete is applied by the Air Meta Act and the Electrostatic Capacity Act. However, there are complex and time-consuming problems with measurement methods. Therefore, high frequency moisture sensor was used for quick and high measurement, and unit-water content of mortar was evaluated through machine running and deep running based on measurement big data.

  • PDF

고주파수분센서(FDR)를 활용한 콘크리트 단위수량 평가에 관한 실험적 연구 (An Experimental Study on the Evaluation of Concrete Unit-Water Content Using High Frequency Moisture Sensor (FDR))

  • 이승엽;양현민;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 가을 학술논문 발표대회
    • /
    • pp.59-60
    • /
    • 2021
  • The unit-water content has a major problem in concrete structures which leads to micro cracks on the concrete during drying time. Thus, the compressive strength and durability of the concrete structures are significantly reduced. Several techniques have been developed to measure the unit-water content in concrete structures such as heating drying, unit volume mass, and capacitance measurements. However, these techniques have problems in during measurement such as longer time, expensive and difficult in analysis of data. Frequency Domain Reflectivity (FDR) is one of the sensors which used to measure the water content. This method has several advantages including easy to measure, inexpensive, and capable of measuring moisture in real time. In this study, an attempt has been made to evaluate the unit-water content in concrete using the FDR sensor and interpret the data with deep learning method.

  • PDF

딥러닝 모델 구조에 따른 모르타르의 단위수량 평가에 대한 비교 실험 연구 (Comparative Experimental Study on the Evaluation of the Unit-water Content of Mortar According to the Structure of the Deep Learning Model)

  • 조양제;유승환;양현민;윤종완;박태준;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 가을 학술논문 발표대회
    • /
    • pp.8-9
    • /
    • 2021
  • The unit-water content of concrete is one of the important factors in determining the quality of concrete and is directly related to the durability of the construction structure, and the current method of measuring the unit-water content of concrete is applied by the Air Meta Act and the Electrostatic Capacity Act. However, there are complex and time-consuming problems with measurement methods. Therefore, high frequency moisture sensor was used for quick and high measurement, and unit-water content of mortar was evaluated through machine running and deep running based on measurement big data. The multi-input deep learning model is as accurate as 24.25% higher than the OLS linear regression model, which shows that deep learning can more effectively identify the nonlinear relationship between high-frequency moisture sensor data and unit quantity than linear regression.

  • PDF

딥러닝과 머신러닝을 이용한 FDR 센서의 콘크리트 단위수량 평가에 관한 연구 (A Study on the Evaluation of Concrete Unit-Water Content of FDR Sensor Using Deep Learning and Machine Learning)

  • 이승엽;윤지원;위광우;양현민;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2022년도 가을 학술논문 발표대회
    • /
    • pp.29-30
    • /
    • 2022
  • The unit-water content has a very significant effect on the durability of the construction structure and the quality of concrete. Although there are various methods for measuring the unit-water content, there are problems of time required for measurement, precision, and reproducibility. Recently, there is an FDR sensor capable of measuring moisture content in real time through an apparent dielectric constant change of electromagnetic waves. In addition, various artificial intelligence techniques that can non-linearly supplement the accuracy of FDR sensors are being studied. In this study, the accuracy of unit-water content measurement was compared and evaluated using machine learning and deep learning techniques after normalizing the data secured in concrete using frequency domain reflectometry (FDR) sensors used to measure soil moisture at home and abroad. The result of comparing the accuracy of machine learning and deep learning is judged to be excellent in the accuracy of deep learning, which can well express the nonlinear relationship between FDR sensor data and concrete unit-water content.

  • PDF

고해상 지형정보와 토양수분을 활용한 다짐도 평가 (Evaluation of Compaction Quality using High-resolution Terrain Factor and Soil Moisture)

  • 김성욱;고대홍;이영재;최은경;김진영;김지선;조진우
    • 한국환경과학회지
    • /
    • 제31권10호
    • /
    • pp.869-881
    • /
    • 2022
  • In this study, a field study was conducted to investigate the relationship between high-resolution remote images and the volumetric moisture, and the number of compaction. Changes in the shape of the surface and soil moisture content were observed and correlated with the number of compactions using roller equipment. As the compaction is repeated, the surface is flattened and the terrain curvature decreases and converges to zero. In particular, the tangential curvature changes as the number of compactions increase. Due to soil compaction, the vegetation index changed from a positive to a negative value, and most of the test site area was homogenized with a negative index. This suggests a decrease in porosity and an increase in volumetric water content associated with increasing soil compaction. Soil moisture, measured using a frequency domain reflectometry(FDR) sensor, tends to increase proportionately with the number of vibration compactions, but the correlation between the number of compactions and soil moisture is unclear. This study suggests that while it is necessary to consider the reproducibility of the experiments performed, the compaction quality of the soil can be evaluated using high-resolution terrain factors and soil moisture.

KEOP-2007 라디오존데 관측자료를 이용한 장마 특성 분석: Part I. 라디오존데 관측 자료 평가 분석 (The Analysis of Changma Structure using Radiosonde Observational Data from KEOP-2007: Part I. the Assessment of the Radiosonde Data)

  • 김기훈;김연희;장동언
    • 대기
    • /
    • 제19권2호
    • /
    • pp.213-226
    • /
    • 2009
  • In order to investigate the characteristics of Changma over the Korean peninsula, KEOP-2007 IOP (Intensive Observing Period) was conducted from 15 June 2007 to 15 July 2007. KEOP-2007 IOP is high spatial and temporal radiosonde observations (RAOB) which consisted of three special stations (Munsan, Haenam, and Ieodo) from National Institute of Meteorological Research, five operational stations (Sokcho, Baengnyeongdo, Pohang, Heuksando, and Gosan) from Korea Meteorological Administration (KMA), and two operational stations (Osan and Gwangju) from Korean Air Force (KAF) using four different types of radiosonde sensors. The error statistics of the sensor of radiosonde were investigated using quality control check. The minimum and maximum error frequency appears at the sensor of RS92-SGP and RS1524L respectively. The error frequency of DFM-06 tends to increase below 200 hPa but RS80-15L and RS1524L show vice versa. Especially, the error frequency of RS1524L tends to increase rapidly over 200 hPa. Systematic biases of radiosonde show warm biases in case of temperature and dry biases in case of relative humidity compared with ECMWF (European Center for Medium-Range Weather Forecast) analysis data and precipitable water vapor from GPS. The maximum and minimum values of systematic bias appear at the sensor of DFM-06 and RS92-SGP in case of temperature and RS80-15L and DFM-06 in case of relative humidity. The systematic warm and dry biases at all sensors tend to increase during daytime than nighttime because air temperature around sensor increases from the solar heating during daytime. Systematic biases of radiosonde are affected by the sensor type and the height of the sun but random errors are more correlated with the moisture conditions at each observation station.

내환경성 금속인식 정보단말기에 관한 연구 (Data Terminal for Metal Detection Application in Hazardous Environment)

  • 최규남
    • 한국정보통신학회논문지
    • /
    • 제15권5호
    • /
    • pp.1183-1188
    • /
    • 2011
  • 고온다습하며 이물질이 존재하는 일반적인 금속감지 기술이 적용되기 어려운 환경에서도 사용할 수 있는 금속위치감지 방법을 제안한다. 섭씨 300도가 넘는 환경에서는 마이크로웨이브, 초음파, 광파를 매체로 하는 일반적인 송수신용 전자소자를 사용하는 금속감지 센서는 전자소자의 동작온도 범위를 넘어서므로 적용하는데 어려움이 있었다. 본 연구에서는 금속감지를 위하여 노출되는 면에는 수동소자를 사용하고 전자파를 금속 위치감지에 이용하는 기법을 사용한 금속의 위치감지 장치에서 전자파의 주파수, 감지거리가 금속감지 센서의 감도에 미치는 영향을 측정하였다. 측정된 결과는 500mm 간격에서도 1mm 해상도를 갖고 위치를 감지할 수 있으며 고온에서도 금속의 위치 측정이 가능함을 보여주었다.

함수율 보정기와 PID제어기를 이용한 곡물 수분 건조 시스템 개발 (A Development of the Grain Moisture Dry System Using Water-rate Compensator and PID Controller)

  • 이창근;심우철;박성진;홍연찬
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 합동 추계학술대회 논문집 정보 및 제어부문
    • /
    • pp.315-318
    • /
    • 2001
  • In this paper recommends the development of automated silo dry & storage system. Most of existing round shaped iron silo arc used for only storage after dry and have many problems in storing. So We have developed an automated dry system which used the previously equipped silo and enables it to be used for storage after dry. The system features high frequency-resistance water sensor in Hopper scale that is in general use within the country its silo that is manufactured by the nerve DSP(TMS320C32) system water compensator and visualization that is finally realized with a personal computer.

  • PDF

Design and Simulation of RFID Tag for Container-Grown Seedlings System

  • Lee, Sang-Hyun;Kim, Kyu-Ha;Jeong, Byeong-Su
    • International Journal of Advanced Culture Technology
    • /
    • 제10권2호
    • /
    • pp.292-299
    • /
    • 2022
  • In precision agriculture (PA), the differences of the agriculture related parameters such as temperature, humidity, soil moisture among different fields are considered and analyzed to precisely utilize water, pesticides, fertilizer, seeds, etc. in fields. Hence, it becomes possible to increase the profit, reduce waste and maintain quality products. This paper suggests a framework for RFID sensor network in view of PA, especially, associated with Container-grown seedlings(CGS), and presents the analysis and simulation by using Ultra High Frequency (UHF) RFID tag system. The simulation is divided into the transmitter and receiver part using Matlab/Simulink. The architecture of the model is flexible to achieve different modulation and encoding types. Finally, some results of the simulation are presents.