• Title/Summary/Keyword: high dynamic range imaging

Search Result 56, Processing Time 0.025 seconds

HIGH QUALITY IMAGE ACQUSITION METHOD USING DUAL PANCHOMATIC CHANNEL

  • Chang, Young-Jun;Kim, Jung-Ah
    • Proceedings of the KSRS Conference
    • /
    • 2007.10a
    • /
    • pp.203-206
    • /
    • 2007
  • The Space-borne electro-optical camera system has panchromatic redundant image channel as well as primary channel in order to increase reliability of satellite system. In most case redundant channel never been used during the whole mission period. Staggered array configuration using redundant image channel and new operation mode proposed which operates primary and redundant channel simultaneously. Without new hardware design, fast electronics and system complexity, we can get 1.414 times more fine GSD image of original system or we can get 1.414 times more SNR or High dynamic range imaging mode. In this paper we deal with several image quality improvement methods using dual panchromatic channel.

  • PDF

Coherent X-ray Diffraction Imaging with Single-pulse Table-top Soft X-ray Laser

  • Kang, Hyon-Chol;Kim, H.T.;Lee, S.K.;Kim, C.M.;Choi, I.W.;Yu, T.J.;Sung, J.H.;Hafz, N.;Jeong, T.M.;Kang, S.W.;Jin, Y.Y.;Noh, Y.C.;Ko, D.K.;Kim, S.S.;Marathe, S.;Kim, S.N.;Kim, C.;Noh, D.Y.;Lee, J.
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2008.02a
    • /
    • pp.429-430
    • /
    • 2008
  • We demonstrate coherent x-ray diffraction imaging using table-top x-ray laser at a wavelength of 13.9nm driven by 10-Hz ti:Sapphire laser system at the Advanced Photonics Research Institute in Korea. Since the flux of x-ray photons reaches as high as $10^9$ photons/pulse in a $20{\times}20{\mu}m^2$ field of view, we measured a ingle-pulse diffraction pattern of a micrometer-scale object with high dynamic range of diffraction intensities and successfully reconstructed to the image using phase retrieval algorithm with an oversampling ratio of 1:6. the imaging resolution is $^{\sim}150$ nm, while that is much improved by stacking the many diffraction patterns. This demonstration can be extended to the biological sample with the diffraction limited resolution.

  • PDF

Modified Exposure Fusion with Improved Exposure Adjustment Using Histogram and Gamma Correction (히스토그램과 감마보정 기반의 노출 조정을 이용한 다중 노출 영상 합성 기법)

  • Park, Imjae;Park, Deajun;Jeong, Jechang
    • Journal of Broadcast Engineering
    • /
    • v.22 no.3
    • /
    • pp.327-338
    • /
    • 2017
  • Exposure fusion is a typical image fusion technique to generate a high dynamic range image by combining two or more different exposure images. In this paper, we propose block-based exposure adjustment considering unique characteristics of human visual system and improved saturation measure to get weight map. Proposed exposure adjustment artificially corrects intensity values of each input images considering human visual system, efficiently preserving details in the result image of exposure fusion. The improved saturation measure is used to make a weight map that effectively reflects the saturation region in the input images. We show the superiority of the proposed algorithm through subjective image quality, MEF-SSIM, and execution time comparison with the conventional exposure fusion algorithm.

3D Shape Acquisition Using HDRI and Structured Lighting (HDR 영상과 구조적 조명을 이용한 3차원 형상 취득 기법)

  • Park, Tae-Jang;Won, Jae-Hyun;Lee, Man-Hee;Park, In-Kyu
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2010.07a
    • /
    • pp.198-200
    • /
    • 2010
  • 구조적 조명 기법은 그레이코드 패턴광을 물체에 투영시켜 정확하게 3차원 형상 정보를 복원 할 수 있는 방법이다. 그러나 물체에 투영되는 그레이코드 패턴광이 카메라에 정확하게 인식 되어야 보다 정밀하게 3차원 좌표를 추정할 수 있다. 즉, 주변광의 밝기가 패턴광의 밝기에 비해 무시할 수 없을 정도로 밝은 경우 카메라가 물체와 투영된 패턴을 정확히 인식하기 어렵다. 본 논문에서는 구조적 조명 기법이 주변의 밝기에 따라 제한적인 문제점을 해결하기 위해 High Dynamic Range Imaging (HDRI) 알고리즘을 적용시켜 보다 넓은 동적 범위의 밝기 영역에서 3차원 형상을 정확하게 복원하는 방법을 제안한다. 실험결과 HDRI를 이용하여 복원하였을 경우 그렇지 않은 경우에 비해 복원 정밀도가 크게 개선되는 것을 확인할 수 있다.

  • PDF

Multi-spectral HDR Imaging System and its Characterization (다중 분광 HDR 이미징 시스템 개발 및 특성화 방법)

  • Kim, Deok-Bong;Seo, Myeong-Guk;Kim, Gang-Yeon;Lee, Gwan-Haeng
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2009.10a
    • /
    • pp.286-287
    • /
    • 2009
  • 본 논문은 다중 분광 HDR 이미징 시스템 개발에 관한 연구로써, 기존 점 기반의 분광방사휘도계의 단점을 보완하기 위해 고안된 시스템이다. 기존 분광방사휘도계는 한 점의 분광방사 휘도 값을 측정할 수밖에 없기 때문에, 여러 개의 샘플을 찍을 때 많은 시간이 드는 단점이 존재한다. 본 연구에서는 HDRI (High Dynamic Range Image) 생성 기술과 다중분광 이미징 기술을 이용하여 시스템을 구성하였다. 상용 분광방사휘도계와 다중 분광 HDR 이미징 시스템으로부터 나온 값을 직접 적용(fitting) 하여 효율적이고 정확한 시스템을 개발하였다.

  • PDF

Application of an imaging plate to relative dosimetry of clinical x-ray beams (Imaging Plate를 이용한 의료용 광자선의 선량측정)

  • 임상욱;여인환;김대용;안용찬;허승재;윤병수
    • Progress in Medical Physics
    • /
    • v.11 no.2
    • /
    • pp.117-122
    • /
    • 2000
  • The IP(imaging plate) has been widely used to measure the two-dimensional distribution of incident radiation since it has a high sensitivity, reusability, a wide dynamic range, a high position resolution. Particularly, the easiness of acquiring digitized image using IP poses a strong merit because recent trend of data handling prefers image digitization. In order to test its usefulness in photon beam dosimetry, we measured the off-axis ratio(OAR) on portal planes and percent depth dose(PDD) within a phantom using IP, and compared the results with the data based on EGS4 Monte Carlo particle transport code, ion-chambers, conventional films. For the measurement, we used 6 MV X-rays, various field sizes. As a result, IP showed significant deviation from ion-chamber measurement: a significant overresponse, 100% greater than that of ion-chamber measurement at deep part of the phantom. Filtration of low-energy scattered photons at deep part of the phantom using 0.5 mm thick lead sheets did improve the result, only to the unacceptable extent. However, portal dose measurement showed possibilities of If as a dosimeter by showing errors less than 5%, as compared with film measurement.

  • PDF

Orbital Parameters Modeling of High Resolution Satellite Imagery for Mapping Applications (매핑을 위한 고해상 위성영상의 궤도요소 모델링)

  • 유환희;성재열;김동규;진경혁
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.18 no.4
    • /
    • pp.405-414
    • /
    • 2000
  • A new generation of commercial satellites like IKONOS, SPOT-5 and OrbView-3,4 will have improved features, especially an higher geometric resolution with a better dynamic radiometric range. In addition high precision orbital position and attitude data will be provided by the on-board GPS receivers, IMU(Inertial Measurement Units) and star trackers. This additional information allows for reducing the number of ground control points. Furthermore this information enables direct georeferencing of imagery without ground control points. In our work mathematical models for calculating the satellite orbital parameters of SPOT-3 and KOMPSAT-1 were developed and can be easily extended to process images from other high resolution imaging systems as they become available.

  • PDF

In Vitro Biocompatibility Test of Multi-layered Plasmonic Substrates with Flint Glasses and Adhesion Films

  • Kim, Nak-Hyeon;Byun, Kyung Min;Hwang, Seoyoung;Lee, Yena;Jun, Sang Beom
    • Journal of the Optical Society of Korea
    • /
    • v.18 no.2
    • /
    • pp.174-179
    • /
    • 2014
  • Since in vitro neural recording and imaging applications based on a surface plasmon resonance (SPR) technique have expanded dramatically in recent years, cytotoxicity assessment to ensure the biosafety and biocompatibility for those applications is crucial. Here, we report the cytotoxicity of the SPR substrate incorporating a flint glass whose refractive index is larger than that of a conventional crown glass. A high refractive index glass substrate is essential in neural signal detection due to the advantages such as high sensitivity and wide dynamic range. From experimental data using primary hippocampal neurons, it is found that a lead-based flint glass is not appropriate as a neural recording template although the neuron cells are not directly attached to the toxic glass. We also demonstrate that the adhesion layer between the glass substrate and the gold film plays an important role in achieving the substrate stability and the cell viability.

KEY SCIENCE OBSERVATIONS OF AGNs WITH THE KaVA ARRAY

  • KINO, MOTOKI;NIINUMA, KOTARO;ZHAO, GUANG-YAO;SOHN, BONG WON
    • Publications of The Korean Astronomical Society
    • /
    • v.30 no.2
    • /
    • pp.633-636
    • /
    • 2015
  • KaVA (KVN and VERA Array) is a new combined VLBI array composed of KVN (Korean VLBI Network) and VERA (VLBI Exploration of Radio Astrometry). Here, we report the following two issues. (1) We review the initial results of imaging observations of M87 at 23 GHz following Niinuma et al. (2014). The KaVA images reveal extended outflows including complex substructures such as knots and limb-brightening, in agreement with previous VLBI observations. KaVA achieves a high dynamic range of ~1000, more than three times better than that achieved by VERA alone. (2) Based on subsequent observations and discussions led by the KaVA AGN SubWorking Group, we set monitoring observations of Sgr $A^{\ast}$ and M87 as our Key Science Project (hereafter KSP) because of the closeness and largeness of their central super-massive black holes. The main science goals of the KSP are (i) testing the magnetically-driven-jet paradigm by mapping velocity fields of the M87 jet, and (ii) obtaining tight constraints on physical properties of the radio emitting region in Sgr $A^{\ast}$. Towards KSP, we show the first preliminary images of M87 at 23 GHz and Sgr $A^{\ast}$ at 43 GHz with the bandwidth of 256 MHz.

Color Correction Method for High Dynamic Range Image Using Dynamic Cone Response Function (동적 원추 세포 응답을 이용한 높은 동적 폭을 갖는 영상 색상 보정 방법)

  • Choi, Ho-Hyoung;Yun, Byoung-Ju
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.49 no.9
    • /
    • pp.104-112
    • /
    • 2012
  • Recently, the HDR imaging technique that mimics human eye is incorporated with LCD/LED display devices to deal with mismatch between the real world scene and the displayed image. However, HDR image has a veiling glare limit as well as a scale of the local contrast problem. In order to overcome these problems, several color correction methods, CSR(center/surround Retinex), MSR (Multi-Scale Retinex), tone-mapping method, iCAM06 and so on, are proposed. However, these methods have a dominated color throughout the entire resulting image after performing color correction. Accordingly, this paper presents a new color correction method using dynamic cone response function. The proposed color correction method consists of tone-mapping and dynamic cone response. The tone-mapping is obtained by using a linear interpolation between chromatic and achromatic. Thereafter, the resulting image is processed through the dynamic cone response function, which estimates the dynamic responses of human visual system as well as deals with mismatch between the real scene image and the rendered image. The experiment results show that the proposed method yields better performance of color correction over the conventional methods.