• Title/Summary/Keyword: high ductility

Search Result 983, Processing Time 0.028 seconds

Experimental study on behavior of tri-directional prestressed composite bridge column under low cyclic loading

  • Yang Chen;Zhaowei Jiang;Yingjun Gan;Jun Ye;Yong Yang
    • Earthquakes and Structures
    • /
    • v.27 no.4
    • /
    • pp.251-262
    • /
    • 2024
  • To improve the seismic behavior of composite column with high strength concrete-filled steel tubular in bridge engineering, four column specimens, including one specimen with vertical prestressing force and three specimens with tri-directional prestressing force, were conducted under low cyclic loading. Test parameters including axial compression ratio, degree of vertical prestressing and existence of prestressed steel strips were emphatically analyzed. Experimental results revealed that applying tri-directional prestressing force to column with high strength concrete-filled steel tubular produced more beneficial behavior in terms of ductility, energy-dissipation and self-centering capacity over that of specimens only with vertical prestress. Moreover, ultimate bearing capacity of composite column was improved with increase of degree of vertical prestress and external axial force, while ductility would be reduced. External axial force showed slight influence on the self-centering behavior. Finally, a calculation equation for predicting the shear capacity of the tri-directional prestressed composite column was proposed and the accuracy of the calculated results validated by experimental data.

Decision of Ultimate Failure Mode of High-Strength Concrete Beams Using Degrading Shear Strength Model (전단내력 감소식을 이용한 고강도 콘크리트 보의 파괴형식 판정 연구)

  • 장일영;송재호;박훈규;황규철
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.05a
    • /
    • pp.207-212
    • /
    • 2001
  • The aim of this study is to present a practical and simple method for decision of ultimate failure mode of high-strength concrete beam members, based on interaction between shear strength and displacement ductility. Four tests were conducted on full-scale beam specimens having concrete compressive strength of 410kgf/$cm^{2}$. Prediction of failure mode from presented method and comparison with test results are also presented

  • PDF

Corrosion of High Strength and High Ductility Al-Mg Develpment Aluminum Alloy (고강도, 고연성 Al-Mg계 알루미늄 개발 합금의 내식성 특성)

  • Choe, In-Gyu;Kim, Si-Myeong;Kim, Sang-Ho
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2015.05a
    • /
    • pp.155-156
    • /
    • 2015
  • 최근 자동차 및 항공기의 경량화 관련하여 알루미늄 합금의 필요성이 높아지고 있으나, 자동차재료에 쓰이는 알리미늄 합금의 경우 높은 이온화 경향 때문에 Fe, Cu, Pb 등과 접촉하면 쉽게 부식되는 단점이 있다. 본 연구에서는 기존의 Magsimal-59 샘플과 본 연구에서 개발한 고용질, 저용질 Duplex 알루미늄 합금과의 내식성을 분극 및 갈바닉을 통해 확인하고, 균질화처리를 통해 내식성을 개선한다.

  • PDF

Evaluation of High-Temperature Tensile Property of Diffusion Bond of Austenitic Alloys for S-CO2 Cycle Heat Exchangers (고온 S-CO2 사이클 열교환기용 스테인리스강 및 Fe-Cr-Ni 합금 확산 접합부의 고온 인장 특성평가)

  • Hong, Sunghoon;Sah, Injin;Jang, Changheui
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.12
    • /
    • pp.1421-1426
    • /
    • 2014
  • To improve the inherent safety of the sodium-cooled fast reactor (SFR), the supercritical $CO_2$ ($S-CO_2$) Brayton cycle is being considered as an alternative power conversion system to steam the Rankine cycle. In the $S-CO_2$ system, a PCHE (printed circuit heat exchanger) is being considered. In this type of heat exchangers, diffusion bonding is used for joining the thin plates. In this study, the diffusion bonding characteristics of various austenitic alloys were evaluated. The tensile properties were measured at temperatures starting from the room temperature up to $650^{\circ}C$. For the 316H and 347H types of stainless steel, the tensile ductility was well maintained up to $550^{\circ}C$. However, the Incoloy 800HT showed lower strength and ductility at all temperatures. The microstructure near the bond line was examined to understand the reason for the loss of ductility at high temperatures.

Structural Performance of Concrete-encased Steel Columns using 800MPa Steel and 100MPa Concrete (800MPa 강재 및 100MPa 콘크리트를 적용한 매입형 합성기둥의 구조성능)

  • Kim, Chang-Soo;Park, Hong-Gun;Choi, In-Rak;Chung, Kyung-Soo;Kim, Jin-Ho
    • Journal of Korean Society of Steel Construction
    • /
    • v.22 no.5
    • /
    • pp.497-509
    • /
    • 2010
  • Five concrete-encased steel columns using high-strength steel($f_{ys}$=801MPa) and high-strength concrete($f_{ck}$=97.7MPa) were tested to investigate the eccentric axial load-displacement relationship. Test parameters included the type, yield strength, and spacing of lateral reinforcement, and also the eccentricity of axial load. To analyze the behavior of the column specimens, the nonlinear sectional analysis using strain-compatibility and confinement effect was performed. To examine the applicability of existing design codes for the composite sections using high-strength materials, the test results were also compared with the predictions by the nonlinear analysis and the design codes. The confinement effect of lateral reinforcement increased the ductility of concrete, and the moment capacity of the column specimens increased with the ductility of concrete. The prediction by the nonlinear analysis gave good agreement with the test results. On the other hand, the ACI 318 neglecting lateral confinement effect underestimated the strength of the column specimens, and the Eurocode 4 using complete plastic capacity of steel section overestimated.

Enhancing the Performance of High-Strength Concrete Corbels Using Steel Fibers and Headed Bars (강섬유 및 헤디드 바를 활용한 고강도 콘크리트 내민받침의 성능 향상)

  • Yang, Jun-Mo;Lee, Joo-Ha;Shin, Hyun-Oh;Yoon, Young-Soo
    • Journal of the Korea Concrete Institute
    • /
    • v.21 no.6
    • /
    • pp.697-703
    • /
    • 2009
  • High-strength concrete corbels with varying percentage of steel fibers and two different anchorage types (welding to transverse bar, headed) for the main tension tie were constructed and tested. The results showed that performance in terms of load carrying capacities, stiffness, ductility, and crack width was improved, as the percentage of steel fibers was increased. In addition, the corbel specimens in which headed bars were used as the main tension tie reinforcements showed superior load carrying capacities, stiffness, and ductility compared to the corbel specimens in which the main tension ties were anchored by welding to the transverse bars. From the test results, it is expected that load carrying capacities, durability, and constructibility of high strength concrete corbels would be improved by using steel fibers and headed bars. Experimental results presented in this paper were also compared with various prediction models proposed by researchers and presented in codes. The truss model proposed by Fattuhi provides fairly good predictions for fiber reinforced high-strength concrete corbels.

Effects of B and Cu Additions on the Microstructure and Mechanical Properties of High-Strength Bainitic Steels (베이나이트계 고강도강의 미세조직과 기계적 특성에 미치는 B 및 Cu 첨가의 영향)

  • Yim, H.S.;Lee, S.Y.;Hwang, B.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.28 no.2
    • /
    • pp.75-81
    • /
    • 2015
  • Effects of B and Cu additions on the microstructure and mechanical properties of high-strength bainitic steels were investigated in this study. Six kinds of high-strength bainitic steels with different B and Cu contents were fabricated by thermo-mechanical control process composed of controlled rolling and accelerated cooling. The microstructures of the steels were analyzed using optical and transmission microscopy, and the tensile and impact tests were conducted on them in order to investigate the correlation of microstructure with mechanical properties. Depending on the addition of B and Cu, various low-temperature transformation products such as GB (granular bainite), DUB (degenerated upper bainite), LB (lower bainite), and LM (lath martensite) were formed in the steels. The addition of B and Cu increased the yield and tensile strengths because of improved hardenability and solid solution strengthening, but decreased the ductility and low-temperature toughness. The steels containing both B and Cu had a very high strength above 1.0 GPa, but showed a worse low-temperature toughness of higher DBTT (ductile-to-brittle transition temperature) and lower absorbed energy. On the other hand, the steels having GB and DUB showed a good combination of tensile and impact properties in terms of strength, ductility, yield ratio, absorbed energy, and DBTT.

Experimental compressive behavior of novel composite wall with different width-to-thickness ratios

  • Qin, Ying;Chen, Xin;Zhu, Xing-Yu;Xi, Wang;Chen, Yuan-Ze
    • Steel and Composite Structures
    • /
    • v.36 no.2
    • /
    • pp.187-196
    • /
    • 2020
  • Double skin composite wall system owns several structural merits in terms of high load-carrying capacity, large axial stiffness, and favorable ductility. A recently proposed form of truss connector was used to bond the steel plates to the concrete core to achieve good composite action. The structural behavior of rectangular high walls under compression and T-shaped high walls under eccentric compression has been investigated by the authors. Furthermore, the influences of the truss spacings, the wall width, and the faceplate thickness have been previously studied by the authors on short walls under uniform compression. This paper experimentally investigated the effect of width-to-thickness ratio on the compressive behavior of short walls. Compressive tests were conducted on three short specimens with different width-to-thickness ratios. Based on the test results, it is found that the composite wall shows high compressive resistance and good ductility. The walls fail by local buckling of steel plates and crushing of concrete core. It is also observed that width-to-thickness ratio has great influence on the compressive resistance, initial stiffness, and strain distribution across the section. Finally, the test results are compared with the predictions by modern codes.

Enhancing the Performance of High-Strength Concrete Corbels Using Hybrid Reinforcing Technique (하이브리드 보강기법을 활용한 고강도 콘크리트 내민받침의 성능 향상)

  • Yang, Jun-Mo;Lee, Joo-Ha;Min, Kyung-Hwan;Yoon, Young-Soo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.13-16
    • /
    • 2008
  • Corbels are short cantilevers that project from the faces of a column and are a type of stress disturbed member, resisting both the ultimate shear force applied to them by the beam, and the ultimate horizontal force caused by shrinkage, temperature changes, and creep of the supported elements. Recently, as there have been an increase in the use of high-strength concrete and the concern about corrosion problems, lots of researches about hybrid reinforcing technique, applying strategically high performance reinforcements to the concrete elements, are performed. In this study, fiber reinforced high strength concrete corbels were constructed and tested for applying hybrid reinforcing technique to the corbels using steel fibers and headed bars. The results showed that the performance in terms of load carrying capacities, stiffness, ductility, and crack width was improved, as the steel fibers were added and the percentage of steel fibers was increased. In addition, the corbel specimens used headed bars as main tension ties showed superior load carrying capacities, stiffness, and ductility to the corbel specimens anchored main tension ties by welding to the transverse bars.

  • PDF

An Experimental Study on the Flexural Behavior of Reinforced High-Strength Concrete Beams Using Belite Cement (Belite 시멘트를 사용한 고강도 철근콘크리트 보의 휨 거동에 관한 실험연구)

  • Han, Sang-Hoon;Koo, Bong-Kuen;Kim, Gee-Soo;Cho, Hong-Dong;Juen, Chea-Man
    • Magazine of the Korea Concrete Institute
    • /
    • v.11 no.1
    • /
    • pp.221-230
    • /
    • 1999
  • A study was conducted to investigate the flexural behavior of reinforced high-strength concrete beams using Belite cement. In this study, fourteen reinforced Belite and control beams were tested. The major experimental variables are compressive strength(350kgf/$cm^2$ and 600kgf/$cm^2$)of concrete and reinforcement ratios(0.0086~0.0345). They were tested by three point loading method. Comparing with flexural behavior of normal reinforced concrete beams, the investigation were to : (1) determine experimentally the load-displacement relationships and the strain distribution on the section of test beams : (2) determine experimentally the moment-curvature and the load-neutral axis relationship of Belite ; (3) investigate the flexural ductility of Belite ; (4) estimate the ratio of the capacities of nominal moment strength as a function of ACI to as a experiment. From the test results, the flexural behavior of reinforced high-strength concrete beams using Belite cement are similar to flexural behavior of normal reinforced concrete beams.