• 제목/요약/키워드: high concentration distribution

검색결과 1,225건 처리시간 0.025초

한국 동남해역의 해양현상에 관한 연구 (Hydrography and Currents in the Southeastern Sea of Korea, October 1982)

  • 김구;민병언
    • 한국항해학회지
    • /
    • 제8권1호
    • /
    • pp.49-70
    • /
    • 1984
  • Spatial and temporal variations of hydrography and currents are investigated in the Southeastern Sea of Korea during October 1982. The distribution of the water mass of high salinity (>34.40${\textperthousand}$) and low dissolved oxygen concentration (<5.0ml/l) indicates that the Tsushima current flows northward as it passes the Western Channel of the Korea Strait. The cold water (<$6.0^{\circ}c$) with low salinity (<$34.20{\textperthousand}$) and high dissolved oxygen concentration (>6.0ml/l) reaches the bottom of the western channel of the Korea Strait after flowing southward leaning against the slope rather than following the deepest part of the Channel. Repeated sections in the Korea Strait show a remarkable change of hydrographic structure over a period of 4 days ; both warn and cold waters are intensified, particularly in the eastern part of the strait toward the Tsushima Island.

  • PDF

고농도 도공과 품질변화의 상관성 연구(1보) -고농도 도공과 유변학적 인자에 대한 연구- (Studies on Relations between High Solid Coating and Quality Changes(I) - Effects of major process factors on coating color rheology -)

  • 이용규;유성종;조병욱;김용식
    • 펄프종이기술
    • /
    • 제39권3호
    • /
    • pp.41-51
    • /
    • 2007
  • In order to elucidate the effects of types and mixing ratio of GCC and clay, coating color concentration, and types of rheology modifiers on high solid coating, various coating colors were prepared, high shear viscosity was measured and then rheology of the coating colors was analyzed. Coating color concentration was able to be increased from 67% to 69% and from 68% to 71% with a higher GCC ratio and with the rheology modifier instead of the synthetic thickener, keeping similar or improved coating color rheology and coated paper quality. The rheological properties of high solid coating color were superior with smaller average particle sizes of clay and latex, wider size distribution of GCC and higher added amount of latex.

DETECTION OF DUST LOADED AIRMASS IN SEAWIFS IMAGERY: AN EMPIRICAL DUST INDEX IN COMPARISON WITH MODEL-PREDICTED DUST DISTRIBUTION OVER THE PACIFIC IN APRIL,1998

  • Fukushima, H.;Schmidt, M.;Sohn, B.J.;Toratani, M.;Uno, I.
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 1999년도 Proceedings of International Symposium on Remote Sensing
    • /
    • pp.89-94
    • /
    • 1999
  • The paper first proposes an empirical algorithm for detecting dust-loaded airmass observed by Sea Wide Field-of-view Scanner (SeaWiFS). The proposed dust index formula is based on the curvature of the spectral reflectance estimated from the SeaWiFS band 4 (510 nm band) through band 8 (865 nm band) data, assuming "clear ocean water" reflectance. Evaluation of the algorithm is made over several typical Asian dust images including the ones over the Pacific in April, 1998, when a major dust event was reported. The study analyzes the performance and the characteristics of the algorithm by comparing the satellite-derived dust index images with contemporaneous columnar concentration of dust particles predicted by a numerical dust transport model. The comparison reveals several small-scale differences although their dust distribution patterns show good agreement generally.

  • PDF

Distribution of Trace Metals in Sediments of Mokpo Coastal Area after a Strong Rainfall

  • Kim Do Hee;Sin Yong Sik
    • Fisheries and Aquatic Sciences
    • /
    • 제5권4호
    • /
    • pp.302-307
    • /
    • 2002
  • The characteristics of trace metals were investigated in the sediments of the Mokpo coastal area, southwestern coast of Korea. Surface sediments were collected in September 3, 2002 after a strong rain event. The sampling sites were categorized into the inner and outer harbour based on salinity distribution and difference of trace metal concentration was evidence between these two zones. The enrichment factor (E' F) of Zn and Cr were high at the mouth of Mokpo Harbour and $E \cdot F$ of Cu was high at the east-south of Dali Island. One hundred percent of Mn and Pb samples and $40\%$ of Zn samples had E' F higher than 1 suggesting that they are accumulated in the entire outer of Mokpo Harbour. Trace metals appeared to be accumulated in the inner harbour by input of sediments in the discharged freshwater from Young-San River during strong rainfall whereas they were influenced by natural sedimentation and human activities in part.

진공인터럽터 외부쉴드가 절연성능에 미치는 영향 분석 (An Analysis of Insulation Performance Result from Shield of Outside Vacuum interrupter)

  • 윤재훈;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.100-100
    • /
    • 2010
  • Because of power consumption increase, global wanning, and limitation of installation, not only high reliability and interruption capability but also compact and light power apparatuses are needed. To improve the insulation performance, the high E field concentration phenomena was considered. Breakdown mechanism in vacuum is different from that in other insulation materials. therefore, It is necessary to understand the electric field distribution and insulation characteristics. This paper discusses the simulation and LI(light impulse) test of the shield of outside vacuum interrupter As a result, FEM simulation and LI test show that improve distribution of electrical field and equi-potential line. due to external shield. in this case, outside shield induced electric field of triple junction point.

  • PDF

Zooplankton community distribution in shallow reservoirs during winter: Influence of environmental factors on Cyclops vicinus (Copepoda: Cyclopoida)

  • Choi, Jong-Yun;Jeong, Kwang-Seuk;Joo, Gea-Jae
    • Journal of Ecology and Environment
    • /
    • 제37권2호
    • /
    • pp.99-104
    • /
    • 2014
  • We estimated the influence of environmental factors on zooplankton communities at 25 reservoirs during winter (December 2010 to January 2011). Among zooplankton groups, Cyclops vicinus is more dominant during winter, and this is positively related to withered vegetation area and dissolved oxygen level. Therefore, the presence of withered vegetation might be considered as an important factor to determine C. vicinus distribution during winter. We considered that withered vegetation might be utilized as a habitat for C. vicinus, as well as provide an attachment substrate for periphytic algae. Abundance of periphytic algae can lead to high concentration of dissolved oxygen. Although copepods prefer high water temperatures for increasing their population growth, if Cyclops can overcome low temperature stress that leads to disruption of population, their population growth initiation in the next growing season (i.e. next spring) is possibly propelled by the winter population.

강제대류시 고순도 Al괴의 응고조직에 미치는 유동의 영향 (A Study on the Effect of Fluid Flow on the Microstructure of High Purity Al Ingot under Forced Flow)

  • 김경민;김헌주;하기윤;윤의박
    • 한국주조공학회지
    • /
    • 제13권6호
    • /
    • pp.540-546
    • /
    • 1993
  • The effects of fluid flow on the purification of aluminum were studied. As the revolution rate(N) increased, the size of columnar grain decreased gradually. The concentration of solidified crystal was decreased with increasing distance from chill and revolution rate(N). Distribution boundary layer thickness(${\delta}$) was calculated from the solute distribution obtained in solid experimentally and by use of BPS equation. The value of ${\delta}$ changed from about $60{\mu}m$ at N value of 27rpm to about $15{\mu}m$ at N value of 1000rpm. From this result, high purification was obtained by decreasing the diffusion boundary layer under forced convection.

  • PDF

광주시 대기오염물질 배출량 변화추이에 관한 연구 (A study on the air pollutant emission trends in Gwangju)

  • 서광엽;신대윤
    • 환경위생공학
    • /
    • 제24권4호
    • /
    • pp.1-26
    • /
    • 2009
  • We conclude the following with air pollution data measured from city measurement net administered and managed in Gwangju for the last 7 years from January in 2001 to December in 2007. In addition, some major statistics governed by Gwangju city and data administered by Gwangju as national official statistics obtained by estimating the amount of national air pollutant emission from National Institute of Environmental Research were used. The results are as follows ; 1. The distribution by main managements of air emission factory is the following ; Gwangju City Hall(67.8%) > Gwangsan District Office(13.6%) > Buk District Office(9.8%) > Seo District Office(5.5%) > Nam District Office(3.0%) > Dong District Office(0.3%) and the distribution by districts of air emission factory ; Buk District(32.8%) > Gwangsan District(22.4%) > Seo District(21.8%) > Nam District(14.9%) > Dong District(8.1%). That by types(Year 2004~2007 average) is also following ; Type 5(45.2%) > Type 4(40.7%) > Type 3(8.6%) > Type 2(3.2%) > Type 1(2.2%) and the most of them are small size of factory, Type 4 and 5. 2. The distribution by districts of the number of car registrations is the following ; Buk District(32.8%) > Gwangsan District(22.4%) > Seo District(21.8%) > Nam District(14.9%) > Dong District(8.1%) and the distribution by use of car fuel in 2001 ; Gasoline(56.3%) > Diesel(30.3%) > LPG(13.4%) > etc.(0.2%). In 2007, there was no ranking change ; Gasoline(47.8%) > Diesel(35.6%) > LPG(16.2%) >etc.(0.4%). The number of gasoline cars increased slightly, but that of diesel and LPG cars increased remarkably. 3. The distribution by items of the amount of air pollutant emission in Gwangju is the following; CO(36.7%) > NOx(32.7%) > VOC(26.7%) > SOx(2.3%) > PM-10(1.5%). The amount of CO and NOx, which are generally generated from cars, is very large percentage among them. 4. The distribution by mean of air pollutant emission(SOx, NOx, CO, VOC, PM-10) of each county for 5 years(2001~2005) is the following ; Buk District(31.0%) > Gwangsan District(28.2%) > Seo District(20.4%) > Nam District(12.5%) > Dong District(7.9%). The amount of air pollutant emission in Buk District, which has the most population, car registrations, and air pollutant emission businesses, was the highest. On the other hand, that of air pollutant emission in Dong District, which has the least population, car registrations, and air pollutant emission businesses, was the least. 5. The average rates of SOx for 5 years(2001~2005) in Gwangju is the following ; Non industrial combustion(59.5%) > Combustion in manufacturing industry(20.4%) > Road transportation(11.4%) > Non-road transportation(3.8%) > Waste disposal(3.7%) > Production process(1.1%). And the distribution of average amount of SOx emission of each county is shown as Gwangsan District(33.3%) > Buk District(28.0%) > Seo District(19.3%) > Nam District(10.2%) > Dong District(9.1%). 6. The distribution of the amount of NOx emission in Gwangju is shown as Road transportation(59.1%) > Non-road transportation(18.9%) > Non industrial combustion(13.3%) > Combustion in manufacturing industry(6.9%) > Waste disposal(1.6%) > Production process(0.1%). And the distribution of the amount of NOx emission from each county is the following ; Buk District(30.7%) > Gwangsan District(28.8%) > Seo District(20.5%) > Nam District(12.2%) > Dong District(7.8%). 7. The distribution of the amount of carbon monoxide emission in Gwangju is shown as Road transportation(82.0%) > Non industrial combustion(10.6%) > Non-road transportation(5.4%) > Combustion in manufacturing industry(1.7%) > Waste disposal(0.3%). And the distribution of the amount of carbon monoxide emission from each county is the following ; Buk District(33.0%) > Seo District(22.3%) > Gwangsan District(21.3%) > Nam District(14.3%) > Dong District(9.1%). 8. The distribution of the amount of Volatile Organic Compound emission in Gwangju is shown as Solvent utilization(69.5%) > Road transportation(19.8%) > Energy storage & transport(4.4%) > Non-road transportation(2.8%) > Waste disposal(2.4%) > Non industrial combustion(0.5%) > Production process(0.4%) > Combustion in manufacturing industry(0.3%). And the distribution of the amount of Volatile Organic Compound emission from each county is the following ; Gwangsan District(36.8%) > Buk District(28.7%) > Seo District(17.8%) > Nam District(10.4%) > Dong District(6.3%). 9. The distribution of the amount of minute dust emission in Gwangju is shown as Road transportation(76.7%) > Non-road transportation(16.3%) > Non industrial combustion(6.1%) > Combustion in manufacturing industry(0.7%) > Waste disposal(0.2%) > Production process(0.1%). And the distribution of the amount of minute dust emission from each county is the following ; Buk District(32.8%) > Gwangsan District(26.0%) > Seo District(19.5%) > Nam District(13.2%) > Dong District(8.5%). 10. According to the major source of emission of each items, that of oxides of sulfur is Non industrial combustion, heating of residence, business and agriculture and stockbreeding. And that of NOx, carbon monoxide, minute dust is Road transportation, emission of cars and two-wheeled vehicles. Also, that of VOC is Solvent utilization emission facilities due to Solvent utilization. 11. The concentration of sulfurous acid gas has been 0.004ppm since 2001 and there has not been no concentration change year by year. It is considered that the use of sulfurous acid gas is now reaching to the stabilization stage. This is found by the facts that the use of fuel is steadily changing from solid or liquid fuel to low sulfur liquid fuel containing very little amount of sulfur element or gas, so that nearly no change in concentration has been shown regularly. 12. Concerning changes of the concentration of throughout time, the concentration of NO has been shown relatively higher than that of $NO_2$ between 6AM~1PM and the concentration of $NO_2$ higher during the other time. The concentration of NOx(NO, $NO_2$) has been relatively high during weekday evenings. This result shows that there is correlation between the concentration of NOx and car traffics as we can see the Road transportation which accounts for 59.1% among the amount of NOx emission. 13. 49.1~61.2% of PM-10 shows PM-2.5 concerning the relationship between PM-10 and PM-2.5 and PM-2.5 among dust accounts for 45.4%~44.5% of PM-10 during March and April which is the lowest rates. This proves that particles of yellow sand that are bigger than the size $2.5\;{\mu}m$ are sent more than those that are smaller from China. This result shows that particles smaller than $2.5\;{\mu}m$ among dust exist much during July~August and December~January and 76.7% of minute dust is proved to be road transportation in Gwangju.

Pb-Sn-Cu삼원 합금 전착층의 균일성 연구 (A study on the uniformity of the electrodeposits in Pb-Sn-Cu ternary alloy plating)

  • 남궁억;권식철
    • 한국표면공학회지
    • /
    • 제18권3호
    • /
    • pp.105-115
    • /
    • 1985
  • Lead-tin-copper ternary alloy electrodeposition is conducted onto the inner bore surface of plain bearings as an overlay in order to investigate the effect of slot width, current density and fluoboric acid concentration on the uniformity of overlay. The thickness of overlay is analyzed by means of current distribution resulting from the overvoltage of plating bath and the apparent distance between cathode and anode. The result demonstrate that the uniformity of overlay is remarkably dependent of the slot size and current density, but has little bearing on the fluoboric acid concentration over 100g/L. This present study indicates that uniform overlay is obtainable within the tolerable thickness of ${\pm}2{\mu}m$ by using the slot width of 22mm. The surface morphology examination also shows the important role of concentration polarization of the micro-uniformity of overlay. The micro-uniformity has improved at the low concentration polarization which resulted from operating at the low current density and high fluoboric acid concentration. The surface morphology of deposits exhibits the vivid pyramid crystalline in the plating condition of low concentration polarizatio and all deposits have columnar structure parallel to the applied electric field regardless of the electroplating condition used.

  • PDF

Analysis of High Concentration Diffusion Pattern by Air Pollutions in Port Industry Interfaces

  • Je-Ho Hwang;Sang-Hyung Park;So-Hyun Yun;Si-Hyun Kim
    • Journal of Korea Trade
    • /
    • 제26권3호
    • /
    • pp.117-136
    • /
    • 2022
  • Purpose - Port is vital for international trade accounting for approximately 80% of world cargo transportation in the global trade sector. Air pollutants emitted owing to the related industry interfaces developed around the port spread throughout the dense population region can have harmful effects on the nearby residents. This study aims to analyze high-concentration diffusion pattern by air pollutants, considering the main management periods by air pollutants. Design/methodology - Employing the concentration criteria per main air pollutant, the analyses of concentration change patterns per air pollutant, wind characteristics that directly affected the air pollutant diffusion, distribution types per air pollutant, and high-concentration diffusion patterns by season according to time changes were conducted. Findings - The substances that caused harmful levels of air pollution in the hinterland living zone of the Busan New Port were PM_10, PM_2.5, and NO_2. Furthermore, the intensive management periods were as follows: For PM_10, 24-h (spring), 12:00-16:00 (summer), 12:00-16:00 (summer), 20:00-12:00 (fall), and 24:00-20:00 (winter), and for PM_2.5, 24-h (all four seasons), and for NO_2, 23:00-04:00 (spring), 23:00-08:00 (summer), and 20:00-08:00 (fall), and 23:00-04:00 (winter). Originality/value - Research finding indicates that regular monitoring and countermeasures to reduce air pollution for each air pollutant makes it possible to achieve effective air quality control in the port and hinterland living zones.