• 제목/요약/키워드: high concentration distribution

검색결과 1,225건 처리시간 0.031초

연면방전 플라즈마를 이용한 톨루엔 처리에 관한 연구 (Toluene Removal Using Surface Discharge Induced Plasma Chemical Process)

  • 부문자;봉춘근;김신도
    • 한국대기환경학회지
    • /
    • 제13권4호
    • /
    • pp.297-305
    • /
    • 1997
  • The experimental study by use of SPCP was fulfilled to remove toluene emitted from various industrial processes. First of all, discharge characteristic was experimented as the change of applied voltage and frequency. Then toluene removal characteristic was tested with the analysis of by-products. As a result, optimum electrical discharge condition was from 20.0 kHz to 25.0 kHz of frequency and from 3.5 kV to 4.0 kV of voltage range. The variation of applied voltage had a more important effect on the removal characteristic of toluene than the frequency variation. The toluene removal efficiency was proportioned to ozone concentration and retention time on discharge plate. It was dropped as increase of toluene concentration, but total treated volume of tolene per power consumption was high. The decomposed toluene was transformed to $CO, CO_2$ and particulates, and the rate of transformation to particulates was higher than CO and $CO_2$ at high toluene concentration. Particulates were increased from 0.017 $\mum$ to 0.3 $\mum$ range of size distribution.

  • PDF

겨울철 서울 내부순환로 도로상 초미세입자 오염의 공간분포 특징 (Spatial Distributions of On-road Ultrafine Particle Number Concentration on Naebu Express Way in Seoul during Winter Season)

  • 우대광;이승복;이승재;김진영;진현철;김태성;배귀남
    • 한국대기환경학회지
    • /
    • 제29권1호
    • /
    • pp.10-26
    • /
    • 2013
  • To understand the traffic emissions with high temporal and spatial resolutions on road, a mobile laboratory was developed. The objective of this study is to characterize on-road air pollution on Naebu express way surrounding the northern area of Seoul, Korea. We measured the number concentration of ultrafine particles larger than 5 nm and particle size distribution using a condensation particle counter and a fast mobility particle sizer, respectively on 3, 7, and 8 December 2009. The average ultrafine particle number concentration on the Naebu express way excluding tunnels was 126,000 particles/$cm^3$ and 4.2 times higher than that on internal road at Korea Institute of Science and Technology in Seoul, and more than twice higher than that measured on and at the arterial roads of Seoul in previous studies. The maximum ultrafine particle number concentration was observed at the tunnel sections. It was 232,000 particles/$cm^3$ and 1.8 times higher than average ultrafine particle number concentration for the other sections on Naebu express way. The ultrafine particle number concentration on the wider roads with higher traffic volume along the Han River was similar to that in the residential section, probably because of enhanced dilution effect in widely open environment. The size distribution of particles on the Naebu express way was highly fluctuated for a short duration. Ultrafine particles measured at the tunnel showed a bimodal size distribution with mode diameters of ~10 nm and ~50 nm. At the Han riverside section, ~10 nm particles appeared significantly compared with size distribution at the tunnel. This on-road measurement approach can be utilized to manage vehicle-related air pollution in urban area.

A Review on Total Gaseous Mercury Concentration Levels in the East Asia

  • Kim, Ki-Hyun
    • 한국지구과학회지
    • /
    • 제24권1호
    • /
    • pp.1-6
    • /
    • 2003
  • In this work, the present concentration levels of total gaseous mercury (TGM) are compared among three East Asian countries, Korea, China, and Japan. Comparison of Hg distribution patterns was made by selecting representative figures for each type of land use among those three countries. The results of the analysis indicate that Hg concentrations within a country can fall into a wide range due probably to the diversity of source processes. It is seen that the urban areas of China and Japan generally exhibit large spatial variability with notably high Hg levels (above 10 ng m$^{-3}$), compared to their Korean counterparts. Although the presence of high Hg levels in Chinese locations can be accounted for by the major man-made source processes (e.g., the use of coal), the causes of unexpectedly high Hg data in Japanese sites appear to be rather complicated. The Hg concentration levels in relatively remote locations however show much reduced values, above 3 ng m$^{-3}$, which is still higher than the typical background concentrations of 1 to 2 ng m$^{-3}$ in Europe or America. Considering that the presence of unusually high Hg levels in urban areas of Asia is the consequence of man-made activities, the prevalence of excessively high Hg values in certain regions of the Asian continent needs further research to accurately assess the fundamental picture of Hg geochemistry in the East Asia.

Cr-Mo강의 수소확산 특성에 관한 유한요소해석 (The Finite Element Analysis on the Characteristics of the Hydrogen Diffusion for the Cr-Mo Steels)

  • 이휘원;하민수
    • 한국기계기술학회지
    • /
    • 제13권2호
    • /
    • pp.115-121
    • /
    • 2011
  • The size of hydrogen molecule is not so small as to invade into the lattice of material, and therefore, hydrogen invades into the material as atom. Hydrogen movement is done by diffusion or dislocation movement in the near crack tip or plastic deformation. Hydrogen appeared to have many effects on the mechanical properties of the Cr-Mo steel alloys. The materials for this study are 1.25Cr-0.5Mo and 2.25Cr-1Mo steels used at high temperature and pressure. The hydrogen amount obtained by theoretical calculation was almost same with the result solved by finite element analysis. The distribution of hydrogen concentration and average concentration was calculated for a flat specimen. Also, finite element analysis was employed to simulate the redistribution of hydrogen due to stress gradient. The calculation of hydrogen concentration diffused into the material by finite element method will provide the basis for the prediction of delayed fracture of notched specimen. The distribution of hydrogen concentration invaded into the smooth and notched specimen was obtained by finite element analysis. The hydrogen amount is much in smooth specimen and tends to concentrate in the vicinity of surface. Hydrogen embrittlement susceptibility of notched specimen after hydrogen charging is more remarkable than that of smooth specimen.

대표적인 열분해가스화 용융시설의 공정별 다이옥신 배출거동에 관한 연구 (A study on the Dioxin behavior in the process of representative pyrolysis/gasfication/melting plant)

  • 신찬기;신대윤
    • 환경위생공학
    • /
    • 제22권1호
    • /
    • pp.1-16
    • /
    • 2007
  • The incineration process has commonly used for wastes amount reduction and thermal treatments of pollutants as the technologies accumulated. However, the process is getting negative public images owing to matter of hazardous pollutants emission. Specially dioxins became a main issue and is mostly emitted from municipal solid wastes incineration. In this reason, pyrolysis/gasfication/melting process is presented as a alternative of incineration process. The pyrolysis/gasfication/melting process, a novel technology, is middle of verification of commercial plant and development of technologies in Korea. But the survey about the pollutant emission from the process, and background data in these facilities is necessary. So in this survey, it Is investigated that the behavior of dioxins in three pyrolysis/gasfication/melting plant (S, T, P) of pilot scale. In case of S plant, concentration of dioxins shows high at latter part of cogenerated boiler and stack which are operate on low temperature conditions than a latter parts of pyrolysis and melting furnace which are operate on high temperature condition. Concentration of gas phage dioxins had increased after combusted gas passed cogenerated boiler and this is attributed to react of precursor materials such as chlorobenzene and chlorophenol. Concentration of dioxins in T plant showed lower levels at latter part of cooling equipment which are operate with water spray type on low temperature conditions than a latter parts of gasfied melting furnace which are operate on high temperature condition. Removal efficiency of dioxins at gas treatment equipment was 78.8 %. Concentration of dioxins in P plant was low at latter part of SDA/BF which is operate at low temperature conditions than a latter parts of pyrolysis gasfied chamber which are operate at high temperature condition. Removal efficiency of dioxins of SDA/BF was 85.9 % and therefore, it showed high efficiency at those of stoker type incineration facility. However, concentration of dioxins which emitted at high temperature condition were low in three facilities and satisfied present standard emission level of dioxins. To consider the distribution ratio of dioxins, Particulate phase dioxins at S and P plants showed similar ratio with which shows in current stoker type for middle scale domestic waste incineration facility. It is necessary to continuos monitoring the ratio of distribution of dioxins in T plant in because ratio of gas phage dioxins showed high.

Concentration and Distribution Characteristics of PM10 in High Schools in the Ulsan Metropolitan Area

  • Jung, Jong-Hyeon;Shon, Byung-Hyun;Phee, Young-Gyu
    • 한국환경보건학회지
    • /
    • 제38권1호
    • /
    • pp.42-50
    • /
    • 2012
  • The purpose of this study was to investigate the concentration and distribution characteristics of $PM_{10}$ at high schools classrooms in Ulsan and its surroundings. This study evaluated $PM_{10}$ levels in classrooms at 79 high schools in Ulsan from May 2008 to May 2009. The average $PM_{10}$ level was 63.8 ${\mu}g/m^3$, and the rate of exceeding the statutory maintenance limit was 16.0%. The average $PM_{10}$ level was higher in general schools (64.9 ${\mu}g/m^3$) compared to professional schools (59.2 ${\mu}g/m^3$), and private schools (66.6 ${\mu}g/m^3$) was higher than that of public schools (62.5 ${\mu}g/m^3$). The average $PM_{10}$ level (68.4 ${\mu}g/m^3$) in general classrooms was significantly (p < 0.01) higher than that in multi-purpose ones (54.6 ${\mu}g/m^3$), and first-year student classrooms (73.3 ${\mu}g/m^3$) was significantly (p < 0.05) higher than that in second or third grade ones (67.6 ${\mu}g/m^3$, 51.5 ${\mu}g/m^3$, respectively). The $PM_{10}$ level in schools in Dong-Gu in the vicinity of assorted industrial complexes was higher than that of schools located in other districts around the Ulsan Metropolitan Area. The regression model showed that $PM_{10}$ level was positively associated with number of students and relative humidity.

비성층 해양방류수역에서의 하수플륨의 혼합구역 특성분석 (Mixing Zone Analysis of Outfall Plumes in Unstratified Oceanic Environment)

  • 강시환;박광순;오병철
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.455-458
    • /
    • 2002
  • Mixing zone characteristics of the wastewater effluents discharged from an ocean outfall have been investigated using an outfall mixing zone analysis method. This analysis was applied to Sokcho ocean outfall case and was used to simulate the concentration distribution of wastewater effluents. Hourly concentration distributions of outfall effluent discharges were averaged for the period of 15 days. The results show that near-field dilution was relatively high with the dilution of 130 for the winter season.

  • PDF

단백질에 결합된 카드뮴과 CdCl2를 섭취한 쥐에서 카드뮴의 체내축적 및 분포의 차이 (Accumulation and Organ distribution of protein Bound Cadmium in Rats compared with CdCl2)

  • 이명희
    • Journal of Nutrition and Health
    • /
    • 제27권8호
    • /
    • pp.828-836
    • /
    • 1994
  • A low level exposure experiment was conducted on growing rats to investigate the accumulation and organ distribution of protein bound cadmium compared with cadmium chloride. Male Sprague-Dawley rats were fed for 21days with one of the semisynthetic diets, which contains cadmium as either bovine liver- or kidney meal bound cadmium, cadmium chloride with uncontaminated liver meal or cadmium chloride without organ meal, in the levels of ca. 0.5, 1 and 1.5mg/kg diet, respectively. After 21days of exposure cadmium was accumulated in liver, kidney and gastrointestinal tracts depending upon cadmium levels in diet. Inspite of very low cadmium accumulation in whole blood, it tends also to increase with dietary cadmium levels. The blood cadmium concentration of animals fed organ meal containing diets was about 4-7 fold higher than that without organ meal, regardless of cadmium was intrinsically bound to protein or not. However, significant effects of organ protein on cadmium accumulation in liver, kidney and digestive tracts were not detectable, when cadmium was supplemented as cadmium chloride. On the other hands, animals fed diet containing ca. 1.5mg Cd/kg as organ bound cadmium retained more cadmium in liver, kidney and digestive tracts compared to cadmium chloride with organ meal, whereby the increase of cadmium concentration in kidney was greater then in liver. However, when the concentration of protein bound cadmium was<1mg/kg diet, organ bound cadmium was not significantly different from cadmium chloride in bioavailability and organ distribution. From this result it is suggested that the intestinal absorption of protein bound cadmium is influenced of the amount of cadmium bound in protein. When cadmium concentration in protein is relatively low, protein bound cadmium seems to be absorbed in the same way as cadmium ions are absorbed. However, when the concentration is high, at least a small amount of intact protein bound cadmium could be absorbed and accumulated selectively in kidney.

  • PDF

부산지역 오존 및 이산화질소 농도의 공간분포해석에 따른 대기오염측정망 배치연구 (A Study on Allocation of Air Pollution Monitoring Network by Spatial Distribution Analysis of Ozone and Nitrogen Dioxide Concentrations in Busan)

  • 유은철;박옥현
    • 한국대기환경학회지
    • /
    • 제20권5호
    • /
    • pp.583-591
    • /
    • 2004
  • In this study, methodologies for the rational organization of air pollution monitoring network were examined by understanding the characteristics of temporal and spatial distribution of secondary air pollution, whose significance would increase hereafter. The data on $O_3$ and $NO_2$ concentrations during high ozone period in 1998~1999 recorded at the nine air pollution monitoring station in Busan were analysed using principal component analysis (PCA) and cumulative semivariogram. It was found that the ozone concentration was deeply associated with the daily emission characteristics or the $O_3$ precusors, and nitrogen dioxide concentration largely depends on the emission strength of regional sources. According to the spatial distribution analysis of ozone and nitrogen dioxide in Busan using cumulative semivariograms, the number of monitoring stations for the secondary air pollution can be reduced in east-west direction, but reinforced in north-south direction to explain the spacial variability. More scientific and rational relocation of air pollution monitoring network in Busan would be needed to investigate pollution status accurately and to plan and implement the pollution reduction policies effectively.

소독부산물 최소화를 위한 운영조건 연구 (Operating Conditions for Minimization of DBPs (Disinfection by-Products) in Drinking Water Supply System)

  • 신형순;최필권;김종수;최일우;김상훈;김태현;이경희;이수문;장은아;정연훈;김주열
    • 상하수도학회지
    • /
    • 제19권3호
    • /
    • pp.330-337
    • /
    • 2005
  • This study was carried out to propose the managemental improvement of the purification plants and the distribution facilities which can minimize the formation of disinfection by-products in drinking water distribution system. The disinfection by-products were highly created in the water treatment plant that the organic matters were high and the chlorine dosage was excessive. The concentration of DSPs was shown the highest value in August and the lowest value in December, because of temperature and pre-chlorine dosage effect. From the result of tracer test, the travel time from the treatment plant to the end of pipeline was around 3-4 days in summer, 5-6 days in winter, respectively, and the DSPs concentration of the reservoir(end of pipe) was 2-3 times higher than that of the beginning point. The improvement of the chlorination process and structural reformation of distribution facility was demanded to minimize the DSPs increase from purification plant to the end of pipe.