• Title/Summary/Keyword: helium filter

Search Result 6, Processing Time 0.02 seconds

Sterilization of Bacteria, Yeast, and Bacterial Endospores by Atmospheric-Pressure Cold Plasma using Helium and Oxygen

  • Lee Kye-Nam;Paek Kwang-Hyun;Ju Won-Tae;Lee Yeon-Hee
    • Journal of Microbiology
    • /
    • v.44 no.3
    • /
    • pp.269-275
    • /
    • 2006
  • Atmospheric-pressure cold plasma (APCP) using helium/oxygen was developed and tested as a suitable sterilization method in a clinical environment. The sterilizing effect of this method is not due to UV light, which is known to be the major sterilization factor of APCP, but instead results from the action of reactive oxygen radicals. Escherichia coli, Staphylococcus aureus, and Saccharomyces cerevisiae deposited on a nitrocellulose filter membrane or Bacillus subtilis spores deposited on polypropylene plates were exposed to helium/oxygen plasma generated with AC input power at 10 kHz, 6 kV. After Plasma treatment, nitrocellulose filter membranes were overlaid on fresh solid media and CFUs were counted after incubation overnight. D-values were 18 sec for E. coli, 19 sec for S. aureus, 1 min 55 sec for S. cerevisiae, and 14 min for B. subtilis spores. D-values of bacteria and yeast were dependent on the initial inoculation concentration, while the D-value of B. subtilis spores showed no correlation. When treated cells were observed with a scanning electron microscope, E. coli was more heavily damaged than S. aureus, S. cevevisiae exhibited peeling, and B. subtilis spores exhibited shrunken morphology. Results showed that APCP using helium/oxygen has many advantages as a sterilization method, especially in a clinical environment with conditions such as stable temperature, unlimited sample size, and no harmful gas production.

A study on output power characteristic of selenium vapour multiline laser using isotope helium and helium filter (헬륨 동위원소 및 헬륨필터를 사용한 셀레늄증기 다중광선레이저의 출력특성에 관한 연구)

  • 최상태
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.2
    • /
    • pp.16-22
    • /
    • 2004
  • The paper presents the effects of output-coupling power and small signal gain of selenium vapour multiline laser by discharge of either to $^4$He or $^3$He. The purity of the He gas was improved with a special He-fille.. The result shows that compared with those of $^4$He, the output-coupling power and small-signal gain of $^3$He increase in the most of the lines. Especially, the small-signal gain of $^3$He for the strong lines (497.6 nm, 499.3 nm, 506.9 nm, 517.6 nm, 522.8 nm, 530.5 nm) lies about 30% higher than that of $^4$He, and the output-coupling power from doubles to triples.

The Importance of Filter Integrity Test to Ensure Sterility of Radiophamaceuticals for Using PET Image

  • Cho, Yong-Hyun;Park, Jun-Hyung;Hwang, Ki-Young;Kim, Hyung-Woo;Lee, Hong-Jae;Kim, Hyun-Ju
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.1
    • /
    • pp.74-77
    • /
    • 2008
  • The radiopharmaceuticals are routinely injected to blood vessel for acquiring PET image. For this reason, It is imperative that they undergo strict quality control measures. Especially, Sterility test is more important than any other quality control procedures. According to the FDA guideline, It requires filter integrity test used in the processing of sterile solutions. Among several methods, we can decide to use bubble point test. We usually use vented GS-filters (Millipore co., USA) which are sterilizinggrade (0.22 um pore size) and are placed upper site on product vial. After the synthesis of $^{18}F$-FDG, solutions wet the membrane in filter and then go into the product vial. By all synthesis steps have finished, we can observe the presence of the bubbles in the product vial. Since we have started this study, we have never found any bubbles in the product vial. Because the maximum pressure intensity of the filter which has set by manufacturer is up to 5 bars, but helium gas pressure is up to 1 bar in our module system. So, we can make 5 bars pressure using helium gas bombe and increase pressure up to 5 bars step by step. However, it does not happen to anything in vial.

  • PDF

Introduction and Expression of Foreign Genes in Rice Cells by Particle Bombardment

  • Jeon, Jong-Seong;Jung, Hou-Sung;Sung, Soon-Kee;Lee, Jong-Seob;Choi, Yang-Do;Kim, Han-Jip;Lee, Kwang-Woong
    • Journal of Plant Biology
    • /
    • v.37 no.1
    • /
    • pp.27-36
    • /
    • 1994
  • For establishing a transformation system of rice, an efficient introduction of foreign genes into embryogenic cell suspension by particle bombardment was conducted. The particle inflow gun based on the acceleration of DNA-coated tungsten particles using pressurized helium was constructed for delivery of DNA into rice cells. Several bombardment parameters were optimized using the transient expression of GUS gene. The conditions that gave the highest GUS gene expression of about 1000 blue spots per g fresh weight of bombarded cells include treatment of the cells with 0.5 M osmotic pressure, and use of the 410 kPa helium, 110 mm target distance, 13 mm syringe filter holder and 5 $\mu$L DNA/tungsten mixtures. It was also confirmed that rice actin promoter-intron construct gave the highest expression of all promoter-sequences studied. Eight weeks after the bombardment, stably transformed calluses were obtained on the selection medium containing 100 mg/L G418 and showed the strong activity in in situ GUS assay.

  • PDF

optical gain and output characteristic of selenium vapour multiline laser on purity of helium (셀레늄증기 다중광선레이저의 헬륨 순도에 따른 광이득과 출력특성)

  • 최상태
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.6
    • /
    • pp.60-65
    • /
    • 2002
  • The purpose of this study is to measure and compare the output power characteristics and optical gain for selenium vapour laser depending on the He gas purity. The purity of the He gas was improved with a special He-filter. During the measurement the individual wavelengths were selected with a birefringent filter. The result shows that compared with those of laser without He-filter, the output-coupling power and small signal gain of laser with He-filter increase in the most of the lines. Especially, the output-coupling power and small signal gain for the strong lines (497.6 nm, 499.3 nm, 506.9 nm, 517.6 nm, 522.8 nm, 530.5 nm), blue(460.4 nm, 464.8 nm) and red(644.4 nm 649.1 nm) lines lies notably higher.

The design and fabricationt for ion fraction measurement of plasma generator (플라즈마발생기의 이온분율 측정 장치 설계 및 제작)

  • Lee, Chan-Young
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.368-368
    • /
    • 2008
  • Ion implantation has been widely developed during the past decades to become a standard industrial tool. To comply with the growing needs in ion implantation, innovative technology for the control of ion beam parameters is required. Beam current, beam profile, ion fractions are of great interest when uniformity of the implant is an issue. Especially, it is important to measure the spatial distribution of beam power and also the energy distribution of accelerated ions. This energy distribution is influenced by the proportion of mass for ion in the plasma generator(ion source) and by charge exchange and dissociation within the accelerator structure and also by possible collective effects in the neutralizer which may affect the energy and divergence of ions. Hydrogen atom has been the object of a good study to investigate the energy distribution. Hydrogen ion sources typically produce multi-momentum beams consisting of atomic ion ($H^+$) and molecular ion ($H_2^+$ and $H_3^+$). In the beam injector, the molecular ions pass through a charge-exchanges gas cell and break up into atomic with one-half (from $H_2^+$) or one-third (from $H_3^+$) according to their accelerated energy. Burrell et al. have observed the Doppler shifted lines from incident $H^+$, $H_2^+$, and $H_3^+$ using a Doppler shift spectroscopy. Several authors have measured the proportion of mass for hydrogen ion and deuterium using an ion source equipped with a magnetic dipole filter. We developed an ion implanter with 50-KeV and 20-mA ion source and 100-keV accelerator tube, aiming at commercial uses. In order to measure the proportion of mass for ions, we designed a filter system which can be used to measure the ion fraction in any type of ion source. The hydrogen and helium ion species compositions are used a filter system with the two magnets configurations.

  • PDF