• 제목/요약/키워드: helical tube

검색결과 82건 처리시간 0.026초

불균일 공기분포와 관의 종류에 따른 핀-관 응축기의 성능 특성에 관한 해석적 연구 (Numerical Study on the Performance of a Fin-and-Tube Condenser with Non-Uniform Air Distribution and Different Tube Types)

  • 조다영;함형창;박창용
    • 설비공학논문집
    • /
    • 제24권12호
    • /
    • pp.858-866
    • /
    • 2012
  • A numerical study was performed to predict the performance of a fin-and-tube condenser. A condenser model was developed and verified by comparing the simulation results with experimental data for a R410A condenser in a residential air-conditioning system. The prediction error was 0.07% and -5.77% for the condenser capacity and pressure drop, respectively. In simulation results, the capacity and pressure drop of the condenser with even air velocity distribution were 0.67% and 12.93% higher than those with uneven distribution of air velocity. It was predicted by the model that the refrigerant distribution at the condenser inlet to the two first passes was not significantly influenced by the air distribution. The simulation results presented that the 1.49% of capacity and 64.6% of pressure drop were reduced by replacing helical microfin tubes with smooth tubes for the condenser.

A Spring Back Calculation Model for the Sensitivity Analysis of Tube Design Parameters of Helical Steam Generator

  • Kim, Yong-Wan;Kim, Jong-In;Huh, Hyung;Park, Jin-Seok;Kim, Ji-Ho
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1999년도 추계학술발표회요약집
    • /
    • pp.355.2-355
    • /
    • 1999
  • The spnng back phenomena occurring in the coiling process of a steam generator tube induces the dimensional inaccuracy and makes the coiling procedure difficult. In this research, an analytical model was developed to evaluate the amount of the spring back for SMART steam generator tubes. The model was developed on the basis of beam theory and elastic-perfectly plastic material property. This model was extended to consider the effect of plastic hardening and the effect of the tensile force on the spring back phenomena. Parametric studies were performed for various design variables of steam generator tubes in order to minimize the spring back in the design stage. A sensitivity analysis has shown that the low yield strength, the high elastic modulus, the small helix diameter, and the large tube diameter result in a small amount of the spring back. The amount of the spring back can be controlled by the selection of adequate design values in the basic design stage and reduced to an allowable limit by the application of the tensile force to the tube during the coiling process.rocess.

  • PDF

두부 CT 검사 시 검사 모드에 따른 화질 및 선량평가 (Image Quality and Dose Assessment According to Examination Mode during Head CT Examination)

  • 강헌효;최우전;김동현
    • 한국방사선학회논문지
    • /
    • 제15권4호
    • /
    • pp.437-444
    • /
    • 2021
  • 두경부 CT 검사시 팬텀을 이용하여 Helical mode, High Pitch Mode, Volume Axial Mode 사용하여 획득한 CT 영상으로부터 환자의 피폭선량과 각 영상의 화질을 비교 및 분석하여 Volume Axial Mode의 유용성을 평가해보고자 한다. 두경부 CT 검사 시 각 mode에 따른 70 kVp, 80 kVp, 100 kVp 관전압에 따라 검사를 시행하였다. 사용 장비로는 GE사의 Revolution(GE Healthcare, Wisconsin USA) 모델과 iMED X-ray Phantom을 이용하였다. 검사 Mode에따른 kVp별로 얻어진 영상을 이용하여 팬텀의 피폭선량을 비교하였으며, 각 영상에 ROI를 설정해 신호대 잡음비와 대조도대 잡음비를 산출하여 영상의 화질을 비교하였다. Volume Axial Mode를 사용하여 검사하였을 때 팬텀의 피폭선량이 Helical에 비해 17.12% 낮게, High Pitch에 비해 5.35% 낮게 측정되었고, 신호대 잡음비와 대조도대 잡음비가 향상되었다. Volume Axial Mode는 고속 회전 스캐너를 이용하여 테이블의 이동이 없이 조사시간을 줄이고, High Pitch Mode와 Helical Mode를 사용했을 때 보다 팬텀의 0.28초의 단시간에 영상을 획득하여 피폭선량이 감소하고 영상의 화질 또한 향상되는 유용한 검사라 할 수 있다. 또, 몸이 불편한 환자의 촬영이나 긴급환자의 CT 촬영에 있어서 Volume Axial Mode의 빠른 검사시간은 최대의 장점이라고 볼 수 있다.

용접관(熔接管)의 용접중(熔接中) 온도분포(溫度分布) (On the Arc Welding Temperature in a Metal Tube)

  • 김효철;박종은
    • 대한조선학회지
    • /
    • 제10권2호
    • /
    • pp.3-8
    • /
    • 1973
  • In a recent year, welding is known as a most powerful process in production of pipe. For the conventional purpose, pipe is welded in axial direction to minimize the welding cost. And for the high pressure pipe, welding is done in helical direction to increase a allowable hoop stress. An analytical welding temperature distributions in a metal tube are obtained as a two dimensional case in quasi-stationary state. Numerical values which have been obtained by the analytical investigation shows a good agreement with the isocromatic lines which have been appeared at oxidized zone along the welds. Therefore it is thought that the analytical result can be used in estimating the heat effect upon the material such as a residual stress and strain, metallurgical change and etc..

  • PDF

상·하지 뼈 SEPCT/CT 검사에서 평판형 CT의 피폭저감 영향에 관한 고찰 (The Study of Influence on Reducing Exposure Dose According to the Applied Flat-panel CT in Extremity Bone SPECT/CT)

  • 김지현;박훈희;이주영;남궁식;손현수;박상륜
    • 핵의학기술
    • /
    • 제17권2호
    • /
    • pp.15-24
    • /
    • 2013
  • SPECT/CT의 수요가 늘면서 CT에 따른 복합적 진단정보에 대한 관심이 대두되고 있으며, 그 잠재적 성능가치에 대한 연구가 다양하게 진행 중이다. 하지만 그에 따른 CT 피폭 저감에 대한 연구는 미비한 실정이다. 그러므로 본 연구에서는 상 하지(extremity) 뼈 SPECT/CT 검사 시 평판형(flat-panel) CT에서의 피폭저감 영향에 대해 고찰하는데 목적을 두었다. 상 하지 뼈 SPECT/CT 검사 시 평판형과 나선형(helical) CT 간의 선량 조건에 따른 영상의 질, 피폭선량 비교를 위해 BrightView XCT (Philips Healthcare, Cleveland, USA)와 Briliance 16 CT (Philips, Healthcare, Cleveland, USA)를 적용하였다. AAPM CT phantom을 대상으로 노이즈(noise), 공간 분해능(spatial resolution)을 평가하였으며, 촬영 조건은 관전압 120 kVp로 고정하고, 관전류량(mAs)는 평판형 CT의 상 하지용 촬영 조건인 20, 30, 40, 50, 60, 70, 80 mA를 기준으로 산출된 mAs를 두 장비에 동일 적용하였다. 각 조건별 동일 촬영거리 내에서 DLP (dose-length product)값을 산출하였다. 또한 CT의 조건변화에 따라 SPECT 영상에 미치는 영향을 확인하기 위해 NEMA IEC body phantom으로 영상을 획득하고 %contrast를 확인하였다. 산출된 정보는 SPSS ver.18로 기술통계 분석 하였다. AAPM phantom에서는 mAs의 증가에 따라 노이즈는 감소하였고, 평판형 CT가 나선형 CT보다 노이즈가 낮았으며, 그 차이는 저선량의 조건일수록 증가하였다. 분해능 평가에서 두 장비 모두 0.75 mm까지 육안으로 식별 가능하였고, 평판형 CT의 경우 선량조건(mA)의 증가에 따라 DLP값이 54-216 mGy cm까지 증가하였으며, 나선형 CT의 경우 177-709 mGy cm로 증가하였다. NEMA IEC body phantom에서는 CT 촬영 조건 변화에 따른 동일한 크기의 구(sphere)에서 측정한 결과 %contrast는 일정한 값을 유지하였다. 동일한 조건을 적용한 평판형과 나선형 CT 간의 선량 조건 변화에 따른 영상의 질은 큰 차이를 보이지 않았으며, 충분한 피폭저감의 효과를 얻을 수 있었다. 또한 SPECT 영상의 %contrast 분석을 통해 영상의 질이 유지되는 것을 확인하였다. 그러므로 촬영범위가 넓지 않고 고분해능을 요구하는 상 하지 뼈 SPECT/CT 검사에서 평판형 CT를 적용하는 것이, 나선형 CT에 비해 낮은 선량조건을 적용함에도 불구하고 유사한 영상의 질을 기대할 수 있다. 또한 이를 통해 실제 임상에서 불필요한 피폭선량 저감에 도움이 되리라 사료된다.

  • PDF

이중 베리어 방전 반응기를 사용한 $NO_x$ 제거에 관한 연구 (A Study on the Double Dielectric Barrier Discharge for $NO_x$ reduction)

  • 김동욱;김응복;정영식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2182-2185
    • /
    • 1999
  • In this experimental study we propose the double dielectric barrier discharge(DDBD) reactor to produce as high an electric field as possible. DDBD reactor is designed to remove $NO_x$ at atmospheric pressures from the moving pollution source such as diesel automobile DDBD reactor consisted of two cylinder glass tubes arranged so that the gas flow was directed between the two tubes. Inside of the inner tube was filled with small metal beads and outside of the inner tube was wounded with stainless wire to form the electrode. The outer tube was surrounded by an aluminum foil In this reactor there are three electrodes, i.e. metal bead(C), helical wire(I) and aluminum foil(0). By using DDBD reactor we will report some interesting results of treatment of the gas which is the dilute mixtures of NO in N2. And then we compared thee results with the results of cylinder-wire(CW) which is one of popularly used reactor in non-thermal plasma applications.

  • PDF

인공수로에서의 수평 배열 헬리컬수차 현장시험 사례와 문제점 (Installation of Pilot Plant and Troubleshootings of Horizontally Linked Helical Turbines with Unconfined Free Flow Condition in Artificial Channel)

  • 강금석;김지영;이광수;명철수
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 춘계학술대회
    • /
    • pp.626-629
    • /
    • 2007
  • 국내외에 아직 개발 실적이 없는 발전소의 해수방류수를 이용한 조류식발전시스템의 개발을 위하여, 현재 하동화력발전소 해수방수로를 대상으로 헬리컬 수차를 이용한 조류식발전 시험설비를 제작 완료하고, 성능 시험이 진행 중이며, 본 연구에서는 성능 시험 과정에서 나타난 제반 문제점을 제시하고 그에 대한 원인 및 대책을 분석해 보았다. 본 시험설비는 인공수로에서 수평 배열 헬리컬수차로서 기계장치의 안정성 및 수차의 효율을 평가하고자 하였다. 조류식 시험장치는 배수로의 빠른 유속으로 인하여 시공이 매우 어려웠으며, 인공수로임에도 불구하고 유지관리를 위한 적정 구조 선정이 곤란한 상황이었다. 또한, 헬리컬 수차는 서로 직렬연결되어 운전할 수 있는 장점이 있으나, 본 연구와 같이 다수의 수차가 연결될 경우, 보다 높은 축정렬 정확성, 커플링, 베어링 정밀도 등이 요구되어 효율 감소의 원인이 됨을 확인하였다. 본 장치는 시험용으로서 정밀한 베어링 및 수밀구조, 증속장치를 채택하지 않았으나, 상업용에서는 이를 개선할 필요성이 있다고 판단된다. 또한, 수차의 설치와 유지관리 조건 향상, 수차 통과부의 유황 개선, 수차의 효율 향상을 위하여 조류식 수차에도 유도수로와 casing, draft tube와 같은 Confined flow 구조를 일부 채택할 필요성이 있다고 판단된다.

  • PDF

원자력 발전소에 대한 밀폐 ${CO}_{2}$ 가스터빈 프로세스의 최적화 연구 (II) -열교환기의 설계에 관하여 - (A Study of th Optimum of closed ${CO}_{2}$ Gas Turbine Process for Nuclear Energy Power Plant(II) - For Optimal Design of Heat Exchanger-)

  • 이찬규;이종원
    • 대한기계학회논문집
    • /
    • 제14권1호
    • /
    • pp.251-258
    • /
    • 1990
  • 본 연구에서는 제 1보에서 다루었던 프로세스 해석의 결과들을 토대로 하여 열교환기의 최적 설계를 행하는데 주력하였다. 먼저, 열교환기의 최적 설계를 행하 는데 주력하였다. 먼저, 열교환기의 열설계에 필요한 CO$_{2}$와 Natrium의 물성치 및 열전달에 관한 기존의 실험식들을 여러문헌으로부터 연구 검토한 후 프로그램에 편 리하게 이용할 수 있도록 전산화 하였으며, 열교환기의 설계시 필요한 전체 경비의 최 소화를 기하는 방향으로 최적화된 설계인자들을 결정하도록 시도하였고 또한 최적화된 프로그램을 개발함으로써 인력, 외화 및 에너지 절감의 효과를 얻고자 하였다.

PIV와 수치해석을 이용한 분지관내 맥동유동의 가시화 (Flow Visualization of Pulsatile Flow in a Branching Tube using the PIV System and Numerical Analysis)

  • 노형운;서상호;유상신
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.535-540
    • /
    • 2000
  • The objective of the present study is to visualize the pulsatile flow fields by using three-dimensional computer simulation and the PIV system. A closed flow loop system was built for the steady and unsteady experiments. The Harvard pulsatile pump was used to generate the pulsatile pressure and velocity waveforms. Conifer powder as the tracing particles was added to water to visualize the flow field. Two consecutive particle images were captured by a CCD camera for the image processing. The cross-correlation method in combination with the moving searching area algorithm was applied for the image processing of the flow visualization. The pulsatile flow fields were visualized effectively by the PIV system in conjunction with the applied algorithm. The range validation and the area interpolation methods were used to obtain the final velocity vectors with high accuracy. The finite volume predictions were used to analyze three-dimensional flow patterns in the bifurcation model. The results of the PIV experiment and the computer simulation are in good agreement and the results show the recirculation zones and formation of the paired secondary flow distal to the apex of the bifurcated model. The results also show that the branch flow is pushed strongly to the inner wall due to the inertial force effect and helical motions are generated as the flow proceeds toward the outer wall.

  • PDF

A Numerical Study on Operating Characteristics of a Miniature Joule-Thomson Refrigerator

  • Hong, Yong-Ju;Park, Seong-Je;Choi, Young-Don
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제12권4호
    • /
    • pp.41-45
    • /
    • 2010
  • Miniature Joule-Thomson refrigerators have been widely used for rapid cooling of infrared detectors, optoelectronic device, and integrated circuits of micro electronics. The typical J-T refrigerator consists of the recuperative heat exchanger with the double helical tube and fin configuration, J-T nozzle, a mandrel, Dewar and a compressed gas storage bottle. In this study, to predict the thermodynamic behaviors of the refrigerator with a compressed gas storage bottle during the cool-down time, numerical study of transient characteristics for a J-T refrigerator was developed. A simplified transient one.dimensional model of the momentum and energy equations was simultaneously solved to consider the thermal interactions of the each component of the refrigerator. To account for effects of the thermal mass of the solid, the heat capacities of the tube, fins, mandrel and Dewar are considered. The results show the charged gas pressure of the gas storage bottle has significant effects on the performance of the J-T refrigerator. At the elevated gas pressure of the gas storage bottle, the large capacity of the compressed gas storage does not need to get the fast cool-down performance of the J-T refrigerator in the cool-down stage.