• 제목/요약/키워드: heavy-weight floor impact

검색결과 136건 처리시간 0.025초

공동주택 바닥충격음의 차음성능 평가 (Evaluation of Floor-Impact Sound Insulation for Apartment Buildings)

  • 윤세철;오종민
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.932-937
    • /
    • 2003
  • In apartment buildings, floor-impact sound has bean regarded as the major source which induces complaints from residents. It is mainly due to the use of light-weight structures. The vibration produced by impact on one part of an apartment building would travel as far as the other parts of structure with a little alleviation. As a result, the impact sound from upstairs has been regarded as a main source of noise causing discontentment among accupants. This study was carried out to measure the floor-impact sound levels and evaluate the insulation performance of floor-impact sound for seven apartment buildings. The floor-impact sound levels were measured for seventeen On-dol floor structures and various factors which influence the floor-impact sound were analyzed.

  • PDF

콘크리트 슬래브와 바닥 상부구조가 일체된 바닥구조의 바닥충격음 (Floor Impact Noise Level for Concrete Slab Integrated with Floor Finishing Layers)

  • 문대호;오양기;정갑철;박홍근
    • 한국소음진동공학회논문집
    • /
    • 제26권2호
    • /
    • pp.130-140
    • /
    • 2016
  • Floating floor is most commonly used at apartment houses in Korea for thermal insulation and reducing impact noise. But it in proven that the floating floor is not effective for reducing the floor impact noise in low frequency range. In most cases, impact sound pressure level under 63 Hz frequency band were actually increased by the resonance of resilient material, lightweight concrete and the finishing mortar installed on it. In this paper, an integrated floor system consist of 70 mm light weight concrete and 40 mm finishing mortar successively installed on the concrete slab was suggested to avoid the resonance. Integrated floor system increases total flexural stiffness and mass per unit area. The natural frequencies of first and second vibration mode were increased and acceleration response and floor impact sound level was decreased in all measurement range.

음향모드를 고려한 공동주택 중량충격음 소음해석 (Numerical Analysis of Heavy-weight Impact Noise for Apartment Units Considering Acoustic Mode)

  • 문대호;박홍근;황재승;홍건호;임주혁
    • 한국소음진동공학회논문집
    • /
    • 제22권7호
    • /
    • pp.676-684
    • /
    • 2012
  • Numerical analysis was performed to investigate the heavy-weight impact noise of apartment houses. The FEM is practical method for prediction of low-frequency indoor noise. The results of numerical analysis, the shape of the acoustic modes in room-2 are similar to that of acoustic pressure field at the fundamental frequency of acoustic modes. And the acoustic pressure was amplified at the natural frequency of the acoustic modes and structural modes. The numerical analysis result of sound pressure level at 63 Hz and 125 Hz octave-band center frequency are similar to the test results, but at 250 Hz and 500 Hz have some errors. Considering most of bang-machine force spectrum exists below 100 Hz, the noise at 250 Hz and 500 Hz are not important for heavy-weight impact noise. Thus, the FEM numerical analysis method for heavy-weight impact noise can apply to estimate heavy-weight impact noise for various building systems.

중량 바닥충격음 충격원의 종류 및 위치에 따른 수음실 음압레벨 변화 (Deviation of sound pressure level in receiving room according to the heavy-weight floor impact sources and it's positions)

  • 주문기;한명호;오양기
    • KIEAE Journal
    • /
    • 제9권4호
    • /
    • pp.23-28
    • /
    • 2009
  • Standard sound source currently used in heavy-weight floor impact sounds that cause many social problems has excessive low-frequency energy within a range from 63 Hz to 125 Hz, and is difficult to evaluate and measure. To solve these problems, studies are widely performed using a new impact source, the impact ball. In this study, the sound fields in a receiving room were compared and analyzed according to the current impact source, the bang machine, and the impact ball. And deviation of sound pressure level according to the impact source positions were compared. In case of impact ball, the sound pressure level was lower at 63 Hz and below and higher at 125 Hz and above. The same trend was observed at the low-frequency range on the horizontal and vertical planes, regardless of the type of the impact source, which showed the influence of the room mode. There was a problem with the variations in the sound pressure level according to the size or shape of the receiving room. And it also shows that change of source positions may effect the single number rating scheme.

감성평가 기반 바닥충격음 등급화 및 수인한도 설정 (Floor impact sound classification and setting Acceptable limit based on psychoacoustical evaluation)

  • 김성민;홍주영;전진용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.7-9
    • /
    • 2014
  • An auditory experiment was conducted to establish annoyance criteria for floor impact noise in apartment buildings. Heavyweight floor impact sounds were recorded using an impact ball; the impact sound pressure level (SPL) together with the temporal decay rate (DR), which is quantified by the dB drop per second, was analyzed. For the experiment, A-weighted exposure levels of the heavy-weight floor impact sounds ranging 34~73 dB were evaluated at 3 dB intervals. Participants used a 7-point verbal scale to evaluate the level of annoyance from floor impact noise. The results show that the annoyance increases with increasing impact SPL and decreasing DR. Consequently, a classification and an acceptable level of floor impact sounds were proposed.

  • PDF

공동주택 모델링을 통한 중량충격음 예측에 관한 연구 (The numerical analysis. of heavy weight impact noise for an apartment house)

  • 황재승;문대호;윤영배;홍건호;박홍근;홍성걸
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 추계학술대회논문집
    • /
    • pp.527-532
    • /
    • 2008
  • In this study, numerical analysis is performed to investigate the sound radiation characteristics of an apartment house according to the type of the slab system. In order to satisfy the boundary condition of the apartment house, the whole floor is modelled with FEM model for three different structural system: wall, RC, flat slab system. From the analytical results, it Is shown that heavy weight floor impact noise of wail type slab is larger than that of the other slab systems and the noise radiated from the wall have great effect on the sound pressure level. The results also show that the vibration energy of RC or flat slab system is widely distributed over the whole slab, which is main reason that the noise induced by the slab systems is reduced in comparison with wail slab system.

  • PDF

완충재의 동특성에 따른 중량충격음 증폭에 관한 해석적 연구 (The effect of dynamic property of absorbing sheet on the amplification of heavy weight floor impact noise)

  • 황재승;문대호;박홍근;홍성걸;홍건호;임주혁;김용남
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2010년도 춘계학술대회 논문집
    • /
    • pp.527-528
    • /
    • 2010
  • Previous experimental results performed by many researchers for a couple of decades in South Korea have shown that an absorbing sheet inserted in a conventional floating slab system for thermal insulation or vibration absorption may amplify the vibration of the slab system at specific frequency ranges depending on the material properties of the sheet. The amplified vibration, consequently, results in the heavy weight floor impact noise exceeding the sound level limit for an apartment house, 50dB. In this study, the amplification mechanism is examined through numerical analysis and a new slab system is proposed to reduce the amplification and control the noise. The new slab system consists of studs connecting the base slab and upper concrete finishing yielding the dramatically increased stiffness of the slab. The numerical simulation is performed to investigate the effect of the slab system with studs on the vibration and noise control. The results show that the performance of the slab is sensitive to the number and location of studs, and the heavy weight floor impact noise can be reduced up to 6-7dB compared to the conventional slab system at the optimal stud location.

  • PDF

공동주택 모델링을 통한 중량충격음 예측에 관한 연구 (The Numerical Analysis of Heavy Weight Impact Noise for an Apartment House)

  • 황재승;문대호;박홍근;홍성걸;홍건호
    • 한국소음진동공학회논문집
    • /
    • 제19권2호
    • /
    • pp.162-168
    • /
    • 2009
  • In this study, numerical analysis is performed to investigate the sound radiation characteristics of an apartment house according to the type of the slab system. In order to satisfy the boundary condition of the apartment house, the whole floor is modelled with FEM model for three different structural system: wall, RC, flat slab system. From the analytical results, it is shown that heavy weight floor impact noise of wall type slab is larger than that of the other slab systems and the noise radiated from the wall have great effect on the sound pressure level. The results also show that the vibration energy of RC or flat slab system is widely distributed over the whole slab, which is main reason that the noise induced by the slab systems is reduced in comparison with wall slab system.

유한 요소법을 이용한 나 슬래브의 2차원 바닥 충격진동 해석 (2-Dimensional Floor Impact Vibration Analysis in Bare Reinforced Concrete Slab Using Finite Element Method)

  • 서상호;전진용
    • 한국소음진동공학회논문집
    • /
    • 제15권5호
    • /
    • pp.604-611
    • /
    • 2005
  • The relationship between floor impact sound and vibration has been studied by field measurements, and the vibration modal characteristics have been analyzed. Vibration levels impacted by a standard heavy-weight impact source have been predicted according to the main design parameters using finite element method. Experimental results show that the dominant frequencies of the heavy impact sounds range below 100 Hz and that they are coincident with natural frequencies of the concrete slab. In addition, simple 2-dimensional finite element models are proposed to substitute 2 types of 3-dimensional models of complicated floor structural slabs those by The analytical result shows that the natural frequencies from first to fifth mode well correspond to those by experiments with an error of less than $12\%$, and acceleration peak value iscoincident with an error of less than $2\%$. Using the finite element model. vibration levels areestimated according to the design Parameters, slab thickness, compressive strength, and as a result, the thickness is revealed as effective to increase natural frequencies by $20\~30\%$ and to reduce the vibration level by 3$\~$4 dB per 30 mm of extra thickness.

바닥충격에 의한 공동주택의 바닥, 벽, 천장의 진동 및 소음방사특성 연구 (Evaluating the Vibrational Characteristics of Floor Impact Noise in Different Structural Elements of an Apartment House)

  • 이병권;전진용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문집
    • /
    • pp.480-485
    • /
    • 2002
  • The overall noise reduction was compared in regard to the vibrational characteristics of floor impact noise in a multi story residential building which has several noise reduction treatments. The vibration through its structural elements such as wall, floor and ceiling and sound emitting were investigated for each insulation treatment. It was found that, in case of heavy-weight impact noise, the vibration energy is emitted mostly from ceiling, but for the light-weight impact noise, most of the energy comes through ceiling and walls. That is, the vibration of a ceiling is the main factor that determines the frequency characteristics of the transmitting noise to lower floors.

  • PDF