• 제목/요약/키워드: heavy wind load

검색결과 47건 처리시간 0.024초

건축구조기준을 활용한 농가지도형 G형 비닐하우스의 풍하중 안전성 평가 (Evaluation of Wind load Safety for Single G-type Greenhouse Using Korean Design Standard)

  • 이우근;신경재
    • 한국농공학회논문집
    • /
    • 제66권1호
    • /
    • pp.39-48
    • /
    • 2024
  • Plastic greenhouses are simple structures consisting of lightweight materials such as steel pipes and polyvinyl chloride. However, serious damage occurs due to heavy winds and typhoon every year. To prevent a collapse of structural members, the Ministry of Agriculture and Rural Development has distributed plans and specifications for disaster-resistant standards. Despite these efforts, more than 50% of greenhouses still do not satisfy the disaster-resistant standards. Among the greenhouses that do not meet these standards, 85% are single-span greenhouses proposed 20 years ago. Consequently, there is a need to evaluate the safety of wind loads for the single-span greenhouse. Unfortunately, there are no design specifications for the greenhouses under wind loads. Therefore, a Korean design standard (KDS) has been utilized. KDS is defined with reference to wind speeds occurring once every 500 years, raising concerns about potential overdesign when considering the durability of plastic greenhouses. To address this, the modified wind load, considering the durability of the plastic greenhouse, was calculated, and a safety evaluation was conducted for sigle G-type plastic greenhouse. It was observed that the moment acting on the windward surface was substantial, and there was a risk of the foundation being pulled out if the basic wind speed exceeded 32 m/s. In terms of the combination strength ratio, it was less than 1.0 only on the leeward side when the basic wind speed was 24 m/s and 26 m/s. However, in all other cases, it exceeded 1.0, indicating an unsafe condition and highlighting the necessity for reinforcement.

풍력타워용 부스닥트 포설시스템 개발 (On Installation of Bus Trunk System for Wind Tower)

  • 이준근;김봉석;박성희;안형준;이희남
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 춘계학술대회 논문집
    • /
    • pp.330-335
    • /
    • 2012
  • A Bus Trunk System for Wind Tower is introduced. A marine cable has been widely used in wind tower or other offshore structure. However, as the electric load capacity is getting increased, the large number of cable lines should be used to cover such a huge amount of electric capacities, which makes the installation make quite difficult due to the heavy weight and volume of the present cables. On the other hand, by using a single bus trunk system line, the power capacity amount of 16 number of cable can be delivered with significant compactness. However, unlike flexible cable, the bus trunk is relatively stiff which could arise resonance phenomenon in the operating condition of wind tower, therefore, the vibration characteristics of bus trunk should be investigated and verify its long-term reliability during the life time of the wind tower.

  • PDF

A study on the action mechanism of internal pressures in straight-cone steel cooling tower under two-way coupling between wind and rain

  • Ke, S.T.;Du, L.Y.;Ge, Y.J.;Yang, Q.;Wang, H.;Tamura, Y.
    • Wind and Structures
    • /
    • 제27권1호
    • /
    • pp.11-27
    • /
    • 2018
  • The straight-cone steel cooling tower is a novel type of structure, which has a distinct aerodynamic distribution on the internal surface of the tower cylinder compared with conventional hyperbolic concrete cooling towers. Especially in the extreme weather conditions of strong wind and heavy rain, heavy rain also has a direct impact on aerodynamic force on the internal surface and changes the turbulence effect of pulsating wind, but existing studies mainly focus on the impact effect brought by wind-driven rain to structure surface. In addition, for the indirect air cooled cooling tower, different additional ventilation rate of shutters produces a considerable interference to air movement inside the tower and also to the action mechanism of loads. To solve the problem, a straight-cone steel cooling towerstanding 189 m high and currently being constructed is taken as the research object in this study. The algorithm for two-way coupling between wind and rain is adopted. Simulation of wind field and raindrops is performed with continuous phase and discrete phase models, respectively, under the general principles of computational fluid dynamics (CFD). Firstly, the rule of influence of 9 combinations of wind sped and rainfall intensity on flow field mechanism, the volume of wind-driven rain, additional action force of raindrops and equivalent internal pressure coefficient of the tower cylinder is analyzed. On this basis, the internal pressures of the cooling tower under the most unfavorable working condition are compared between four ventilation rates of shutters (0%, 15%, 30% and 100%). The results show that the 3D effect of equivalent internal pressure coefficient is the most significant when considering two-way coupling between wind and rain. Additional load imposed by raindrops on the internal surface of the tower accounts for an extremely small proportion of total wind load, the maximum being only 0.245%. This occurs under the combination of 20 m/s wind velocity and 200 mm/h rainfall intensity. Ventilation rate of shutters not only changes the air movement inside the tower, but also affects the accumulated amount and distribution of raindrops on the internal surface.

해상풍력발전기 설치선박의 스퍼드캔 구조강도 예측법 (Estimation of Structural Strength for Spudcan in the Wind Turbine Installation Vessel)

  • 박주신;이동훈;서정관
    • 해양환경안전학회지
    • /
    • 제28권1호
    • /
    • pp.141-152
    • /
    • 2022
  • 친환경 에너지원 개발에 관한 관심이 증가하면서, 해상풍력발전기 시장은 매년 높은 증가율을 보이면서 성장하고 있다. 이와 맞물려 대용량 해상풍력발전기를 설치할 수 있는 설치선의 수요 또한 급증하고 있다. 풍력발전기 설치 선박(Wind Turbine Installation Vessel)은 설치 및 해체를 위하여 레그(Leg)와 스퍼드캔(Spudcan)을 해저면에 관입시켜서 고정하며, 이때 스퍼드캔 구조 강도 안전성에 대한 검토는 전체 시스템과 연관된 중요한 문제이다. 본 연구에서는 현재 선급에서 제시하고 있는 절차서를 분석하고, 실제 발생할 수 있는 하중 시나리오를 반영한 새로운 절차서를 제안하였으며, 유한요소해석을 통한 검증을 하였다. 기존 방식은 해저면의 기울기와 레그에 발생하는 휨모멘트 그리고 형상에 따른 영향을 검토하지 않기 때문에, 허용응력보다 작은 최대 응력 값을 보이지만, 신규 절차에 따른 결과는 대부분 구조보강이 발생하였다. 이러한 현상은 해상풍력발전기의 크기가 커지면 커질수록 차이가 크게 나타나며, 실제 관입(Pre-load) 조건을 고려하면 상당수의 부재에서 구조적 문제가 발생할 가능성이 있다. 따라서 본 연구에서는 더욱 실제적인 작업조건을 고려한 절차서를 제안하였고, 적용 시 문제점들에 대해서 구조해석을 통한 검증을 수행하였다.

TPO 시트재와 유도가열공법을 적용한 고내풍성 지붕마감 공법 (The Roofing System of High wind-Resistant Performance using Thermoplastic polyolefin and Electromagnetic Induction Technology)

  • 최희복;신윤석;최진철;이보형;강경인
    • 한국건축시공학회지
    • /
    • 제9권1호
    • /
    • pp.103-109
    • /
    • 2009
  • Strong winds according to global warming cause the increase of the frequency and the repair cost of damaged roofs. In the United States, Factory Mutual Insurance Company(FMIC) promotes the roofing design that resists heavy wind-load, as the means of strict criteria. This fact reveals that more durable roofing system will be also required in Korea. Therefore, this study aims at developing such a system with high wind-resistance performance using Thermoplastic polyolefin(TPO) and Electromagnetic induction technology(EIT) than the previous systems. The system presented in this study consists of 4 main devices as follow; 1) a disc to fix sheets for TPO & EIT method, which can conduct structural design according to site condition, such as region, building height, and wind load. 2) a nail to have about 30% stronger lifting-up capacity than that of the previous nail. 3) a disc to fix sheets, which has triangle protuberance not to damage sheets in the repeatable wind load, and 4) a electromagnetic induction device to combine a disc and a sheet by heating uniformly and quickly adhesive agent on the disc. The results of mock-up test illustrate that the system provides wind-resistant performance to achieve satisfactorily the structural design criteria of FMIC. In addition, the system is faster, chipper, and easier than the existing system, and is expected that this roofing system can be applied to the rehabilitations of an existing as well as a new building.

응력해석을 통한 풍력 발전기용 피치/요 베어링 설계 검증 (Design evaluation of wind turbine pitch/yaw bearings by contact stress analysis)

  • 가재원;김재동;남용윤;임채환;박영준;방제성;이영신
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 추계학술대회 초록집
    • /
    • pp.43.2-43.2
    • /
    • 2011
  • Wind turbine pitch/yaw bearings are relatively big and have different operating conditions like very heavy load to support compared with widely used industrial bearings. Once pitch/yaw bearings failed, according to their special surroundings, serious damages like higher repair costs and additional costs by stopped electricity generation are occur. Therefore, pitch/yaw bearings must be designed to have enough strength and fatigue life under actual operating conditions. In this study, with finite element analysis, it was investigated that stress distribution between rolling elements and raceway and comparatively analyzed using widely used guideline (NREL DG03). Design parameters of wind turbine pitch/yaw bearings are also analyzed, and it could be used as reference for the large bearing design field.

  • PDF

내재해형 조립 비닐하우스 골조 구조시스템 개발 연구 (A Study on the Development of Stress Tolerant Structural Systems in the Frame of Built-up Greenhouses)

  • 한덕전;심종석
    • 한국농촌건축학회논문집
    • /
    • 제18권2호
    • /
    • pp.11-18
    • /
    • 2016
  • The collapsing accidents of greenhouse frames have been increased yearly due to strong wind and heavy snow, but as it was, there were few studies about the structural safety of greenhouses. Therefore, this study was carried out to develop the stress tolerant structural frame systems in built-up greenhouses. The vertical loading experiment of developed scale models were implemented and the developed types of models were simulated by 3-D analysis program in this study. These types of models, which are existing type and honeycomb type, in arch and standard style frames were classified. As a result of this study, it was verified that the honeycomb type model of arch style frame is better than the existing type model of it in stress resistance against snow load and wind load.

Modeling and Control of IGBT Converter-Based High-Voltage Direct Current System

  • Kim, Hong-Woo;Ko, Suk-Whan;An, Hae-Joon;Jang, Gil-Soo;Ko, Hee-Sang
    • 조명전기설비학회논문지
    • /
    • 제25권7호
    • /
    • pp.97-104
    • /
    • 2011
  • This paper presents modeling and control for the emerging IGBT converter-based high-voltage direct-current system (IGBT-HVDC). This paper adds to the representation of the IGBT-HVDC system in the dq-synchronous reference frame and its decoupled control scheme. Additionally, since the IGBT-HVDC is able to actively support the grid due to its capacity to control independently active and reactive power production, a reactive power control scheme is presented in order to regulate/contribute to the voltage at a remote location by taking into account its operational state and limits. The ability of the control scheme is assessed and discussed by means of simulations using ahybrid power system, which consists of a permanent magnetic synchronous-generator (PMSG) based wind turbine, an IGBT-HVDC, and a local load.

풍력타워용 부스덕트 포설시스템 개발 (Development of the Bus Duct Installation System for Wind Tower)

  • 이희남;이준근;김봉석;박성희
    • 한국소음진동공학회논문집
    • /
    • 제24권3호
    • /
    • pp.219-226
    • /
    • 2014
  • A bus duct system for wind tower is introduced. A marine cable has been widely used in wind tower or various offshore structures. However, as the electric load capacity is increases, large number of cable lines must be used to cover the huge amount of electric capacities. Therefore, the installation of the cable lines becomes very difficult due to the heavy weight and volume of the cables. On the other hand, by using a single bus duct system line, the power capacity amount of 16 cables can be delivered with significantly compacted form. However, unlike flexible cables, the bus duct is relatively stiff which could generate the resonance phenomenon in the operating condition of the wind tower. In this study, the vibration characteristics of the bus duct are investigated and its long-term reliability during the life time of the wind tower is verified.

재배작물별 단동비닐하우스의 안전풍속 및 적설심 분석 (Analysis of Safety Wind Speed and Snow Depth for Single-Span Plastic Greenhouse according to Growing Crops)

  • 이종원
    • Current Research on Agriculture and Life Sciences
    • /
    • 제31권4호
    • /
    • pp.280-285
    • /
    • 2013
  • 국내에 설치되어 있는 원예시설 중 가장 많은 면적을 차지하고 있는 단동비닐하우스의 기상재해로 인한 피해를 경감시킬 수 있는 모델 개발에 필요한 기초자료를 제공하고자 재배작물별로 대표적인 온실규격를 선정하여 안전풍속과 적설심을 구한 후 재현기간 8년에 해당하는 지역의 설계풍속 및 적설심과 비교하여 온실의 구조 안전성을 분석한 결과를 요약하면 다음과 같다. 1. 재배작물별 대표온실에 단위풍하중을 적용한 결과, 최대 단면력은 과채류, 근채류, 엽채류 온실 순으로 크게 나타났으며 재배작물별 서까래 간격을 고려한 안전풍속은 엽채류 온실이 17.7 m/s, 과채류 온실이 20.2 m/s, 근채류 온실이 22.3 m/s로 나타나 지역별 8년 빈도의 설계풍하중과 비교하였을 때 홍천, 이천, 성주지역을 제외하고는 대부분의 지역에 있어서 불안전한 것으로 나타났다. 2. 재배작물별 대표온실에 단위 적설하중을 적용한 결과, 근채류 온실의 최대 단면력이 가장 크게 나타났으나 재배작물별 서까래 간격을 고려한 안전적설심은 엽채류 온실이 8.8 cm, 과채류 온실이 9.4 cm, 근채류 온실이 11.8 cm인 것으로 나타났다. 이러한 결과를 지역별 8년 빈도의 적설하중과 비교하였을 때 경남지역 일부를 제외하고는 대부분의 지역에 있어서 불안전한 것으로 분석되었다. 3. 재배작물별 대표 온실의 안전풍속과 적설심에 대하여 구조물에 발생하는 최대 인발력은 12.7~15.1 kgf/개소, 최대 연직하중은 20.6~21.7 kgf/개소로 나타나 기초는 안전한 것으로 분석되었으나 안전풍속과 안전적설심이 매우 작기 때문에 폭설이나 강풍에 대비한 보강이 필요한 것으로 나타났다. 4. 재배작물별 대표온실의 안전풍속과 적설심을 증가시키기 위해서는 서까래 간격을 감소시키거나 부재의 단면 치수를 증가시키는 등의 보강대책이 필요한 것으로 나타났다.