• 제목/요약/키워드: heating time

검색결과 2,349건 처리시간 0.028초

Defrosting Behavior of Fin-Tube Heat Exchanger with PTC Heating Sheet

  • Jhee, Sung;Lee, Kwan-Soo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제9권1호
    • /
    • pp.29-38
    • /
    • 2001
  • In this paper, the defrosting characteristics of a PTC heating sheet is investigated by means of a defrosting heat source for the fin-tube heat exchanger in a refrigerator The defrosting characteristics of the PTC heating sheet are examined and compared with those of a conventional electric heater experimentally. It is found that the characteristics of the water draining rate with the defrosting time show a smoothly oscillating pattern when the PTC heating sheet Is used, and the drained water is completely melted. The defrosting efficiency of the PTC heating sheet is found to be about 75%, which is about 25% higher than that of the electric heater. Also, the reduction of the defrosting time and the increment of the defrosting efficiency may be obtained by improving the arrangement of the heating elements of the healing sheet. It is shown that the defrosting time of the PTC heating sheet increases linearly with the amount of frost, whereas the defrosting efficiency is nearly constant. When applying the PTC heating sheet to the refrigerating system, one should notice the fact that the defrosting performance of the PTC heating sheet may be degraded due to the repetitive operations.

  • PDF

카본블랙/나일론 66 혼합 나노섬유웹의 마이크로파에 의한 접착거동 (Bonding Behavior of Carbon Black/Nylon 66 Hybrid Nanofiber Webs via Microwave Heating)

  • Shin, Dong-Ho;Joo, Chang-Whan
    • 한국섬유공학회:학술대회논문집
    • /
    • 한국섬유공학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.114-117
    • /
    • 2003
  • Conventional heating the heat source cause the molecules to react from the surface toward the center so that successive layers of molecules heat in turn. The product surfaces may be in danger of over heating by the time heat penetrates the material. Microwave, however, produce a volume heating effect. All molecules are set in action at the same time. It also evens temperature gradients and offers other important benefits such as selective heating. (omitted)

  • PDF

YSZ/Ni-Cr 저항 발열 복합용사피막의 특성 (Characteristics of plasma sprayed composite YSZ/Ni-Cr resistant heating coatings)

  • 김병수;박경채;김태형;양병모
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2003년도 춘계학술발표대회 개요집
    • /
    • pp.111-113
    • /
    • 2003
  • The existing heating unit is indirect-heating method that make use or the nichrome wire or halogen lamp. The indirect-heating method has the demerits of long warming time, high power consumption and many organization parts. In this study, the heating unit of direct-heating method manufactured as being the thermal spray coating of conductive heating material on the surface of heating unit in order to improve the demerits of indirect-heating method. And YSZ added Ni-20Cr that had moderate electrical resistivity was chosen of the conductive heating material.

  • PDF

Fracture toughness of high performance concrete subjected to elevated temperatures Part 2 The effects of heating rate, exposure time and cooling rate

  • Zhang, Binsheng;Cullen, Martin;Kilpatrick, Tony
    • Advances in concrete construction
    • /
    • 제5권5호
    • /
    • pp.513-537
    • /
    • 2017
  • In this study, the fracture toughness $K_{IC}$ of high performance concrete (HPC) was investigated by conducting three-point bending tests on a total of 240 notched beams of $500mm{\times}100mm{\times}100mm$ subjected to heating temperatures up to $450^{\circ}C$ with exposure times up to 16 hours and various heating and cooling rates. For a heating rate of $3^{\circ}C/min$, $K_{IC}$ for the hot concrete sustained a monotonic decrease trend with the increasing heating temperature and exposure time, from $1.389MN/m^{1.5}$ at room temperature to $0.942MN/m^{1.5}$ at $450^{\circ}C$ for 4-hour exposure time, $0.906MN/m^{1.5}$ for 8-hour exposure time and $0.866MN/m^{1.5}$ for 16-hour exposure time. For the cold concrete, $K_{IC}$ sustained a two-stage decrease trend, dropping slowly with the heating temperature up to $150^{\circ}C$ and then rapidly down to $0.869MN/m^{1.5}$ at $450^{\circ}C$ for 4-hour exposure time, $0.812MN/m^{1.5}$ for 8-hour exposure time and $0.771MN/m^{1.5}$ for 16-hour exposure time. In general, the $K_{IC}$ values for the hot concrete up to $200^{\circ}C$ were larger than those for the cold concrete, and an inverse trend was observed thereafter. The increase in heating rate slightly decreased $K_{IC}$, and at $450^{\circ}C$ $K_{IC}$ decreased from $0.893MN/m^{1.5}$ for $1^{\circ}C/min$ to $0.839MN/m^{1.5}$ for $10^{\circ}C/min$ for the hot concrete and from $0.792MN/m^{1.5}$ for $1^{\circ}C/min$ to $0.743MN/m^{1.5}$ for $10^{\circ}C/min$ for the cold concrete after an exposure time of 16 hours. The increase in cooling rate also slightly decreased $K_{IC}$, and at $450^{\circ}C$ $K_{IC}$ decreased from $0.771MN/m^{1.5}$ for slow cooling to $0.739MN/m^{1.5}$ for fast cooling after an exposure time of 16 hours. The fracture energy-based fracture toughness $K_{IC}$' was also assessed, and similar decrease trends with the heating temperature and exposure time existed for both hot and cold concretes. The relationships of two fracture toughness parameters with the weight loss and the modulus of rapture were also evaluated.

지역난방 동절기 공동주택 온수급탕부하의 LS-SVM 기반 모델링 (LS-SVM Based Modeling of Winter Time Apartment Hot Water Supply Load in District Heating System)

  • 박영칠
    • 설비공학논문집
    • /
    • 제28권9호
    • /
    • pp.355-360
    • /
    • 2016
  • Continuing to the modeling of heating load, this paper, as the second part of consecutive works, presents LS-SVM (least square support vector machine) based model of winter time apartment hot water supply load in a district heating system, so as to be used in prediction of heating energy usage. Similar, but more severely, to heating load, hot water supply load varies in highly nonlinear manner. Such nonlinearity makes analytical model of it hardly exist in the literatures. LS-SVM is known as a good modeling tool for the system, especially for the nonlinear system depended by many independent factors. We collect 26,208 data of hot water supply load over a 13-week period in winter time, from 12 heat exchangers in seven different apartments. Then part of the collected data were used to construct LS-SVM based model and the rest of those were used to test the formed model accuracy. In modeling, we first constructed the model of district heating system's hot water supply load, using the unit heating area's hot water supply load of seven apartments. Such model will be used to estimate the total hot water supply load of which the district heating system needs to provide. Then the individual apartment hot water supply load model is also formed, which can be used to predict and to control the energy consumption of the individual apartment. The results obtained show that the total hot water supply load, which will be provided by the district heating system in winter time, can be predicted within 10% in MAPE (mean absolute percentage error). Also the individual apartment models can predict the individual apartment energy consumption for hot water supply load within 10% ~ 20% in MAPE.

PTC 전열시트를 사용한 핀-관 열교환기의 제상 특성에 관한 실험적 연구 (An experimental study of defrosting behaviors on the fin-tube heat exchanger with PTC heating sheet)

  • 지성;이관수
    • 설비공학논문집
    • /
    • 제11권1호
    • /
    • pp.147-155
    • /
    • 1999
  • In this work, the defrosting characteristics of PTC heating sheet used as a defrosting heat source of fin-tube heat exchanger in a refrigerator have been experimentally compared with those of conventional electric heater. It is found that the characteristics of water draining rate with defrosting time show smoothly oscillating pattern when PTC heating sheet is used, and the drained water is completely melted. The defrosting efficiency of the PTC heating sheet is about 75%, which represents about 25% higher than that of the electric heater. A reduction of defrosting time and an increase of defrosting efficiency may be obtained by improving the arrangement of heating elements of the heating sheet. It is shown that the defrosting time of PTC heating sheet increases linearly with the amount of frost, however the defrosting efficiency is nearly constant. In the application to the refrigerating system, one should notice the fact that the defrosting performance of PTC heating sheet may be defraded due to the repeated operations.

  • PDF

알루미늄소재의 재가열 공정에서 구상화의 크기가 기계적 성질에 미치는 영향 (The Effect of globule size on the Mechanical Properties in Reheating Process of Aluminium Alloys)

  • 박상문;강충길
    • 소성∙가공
    • /
    • 제11권2호
    • /
    • pp.155-164
    • /
    • 2002
  • One of the important steps on semi-solid forming Is the reheating process of raw materials to the semi-solid state. This Process is not only necessary to achieve the required SSM billet state, but also to contro1 the microstructure of the billet. In reheating process, the globule size is determined by the holding time of last heating stage. Therefore, some experiments to investigate the relationship between the mechanical properties and the holding time in the last heating stage was performed. The alloys used in this experiment were 357, 319 and A390 alloys. The experiments of reheating were performed by using an Induction heating system with the capacity of 50kw. This paper shows the evolution of the microstructure according to the holding time of last reheating stage. Furthermore, to evaluate the effect of globule size controlled by holding time in last heating stage uniaxial tension test was performed. The strain-stress curves were plotted according to the holding time.

자동차용 고장력 강판의 열처리에 관한 연구 (A Study on the Annealing of High Tensile Strength Steel for Automobile)

  • 박범식
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 1999년도 추계학술대회 논문집 - 한국공작기계학회
    • /
    • pp.530-535
    • /
    • 1999
  • In recently, annealing process of cold rolled sheet tend to change to continuous annealing process for improving quality, saving yield. In the meantime as demand for various kind and small lot of products has been increasing, batch annealing has been appreciated for its small restriction for the operation. So, we tested on the effect for the proper heating temperatures, heating time of cycle, cooling time and total cycle time in this annealing process of hi tensile strength steel for automobile. As a result of several investigation. we confirmed for the following characteristics; In this process, we knew that 68$0^{\circ}C$ is suitable for this heating temp. cycle heating time of 38 Hr, cooling time of 31 Hr and total cycle time of 70 Hr. Still more, we could know that it is proper for cold rolling before annealing to be managed by 7 pass because of the act on high pressure.

  • PDF

가열온도, 가열시간 및 부형제의 첨가량이 도축 반추위 내용물의 자일란, 셀룰로오스 및 전분 분해효소 활성에 미치는 영향 (Effects of Temperature and Time for Heating and Filler Content on the Activities of Xylanase, Cellulase and Amylase in Slaughterhouse Rumen Content)

  • 원미영;이도형;김은중
    • 한국초지조사료학회지
    • /
    • 제33권1호
    • /
    • pp.58-66
    • /
    • 2013
  • 본 연구는 도축장에서 폐기되는 도축 반추위 내용물을 사일리지 혹은 TMR (total mixed ration) 사료 첨가용 효소제로 개발하기 위한 목적으로 수행되었다. 도축 반추위 내용물에는 상당한 수분이 함유되어 있어, 적절한 건조과정을 거치지 않고서는 그 활용이 원활하지 않다. 그러나 효소는 열에 민감한 단백질로 구성되어 있기 때문에 적절한 건조 조건의 개발이 필요하다. 본 연구에서는 통계적 방법을 이용하여 가열온도(60, 75, $90^{\circ}C$), 가열시간(12, 30, 48 시간) 및 부형제의 비율(12, 22.5, 33%)이 도축 반추위 내용물에 함유된 다양한 효소활성에 미치는 효과를 분석하였다. 총 3가지 효소, xylan 분해효소, 셀룰로오스 분해효소 및 전분 분해효소를 검토하였고, 각 효소활성들에 대한 각 요인들의 효과가 매우 다양하게 나타났다(p<0.05). 셀룰로오스 분해효소와 전분 분해효소의 활성은 가열온도가 증가함에 따라 감소하였으며(p<0.05), xylan 분해해소는 열에 대한 안전성이 다른 효소들에 비하여 우수하였다. 자일란, 셀룰로오스, 전분 분해효소를 증가시키는 적정 부형제의 비율은 22.5, 12 그리고 33%로 나타났다. 비록 3가지 효소들의 제형화에 있어 공통적으로 적용될 수 있는 최적점을 도출하지는 못하였으나, 본 연구결과에서 얻어진 효소들의 반응 값들을 이용하여 목적하는 효소에 따라서 다양한 방법으로 적용이 가능할 것으로 판단된다.

전열을 이용한 금형가열코어의 제작 및 이를 이용한 성형품의 제조와 평가 (Fabrication of electrical heating mold core and evaluation of injection-molded parts by various mold heating methods)

  • 김동학;류지원;손영곤
    • 한국산학기술학회논문지
    • /
    • 제7권4호
    • /
    • pp.738-742
    • /
    • 2006
  • 본 연구에서는 전열을 이용한 금형가열 장치를 설계 및 제작하였다. 서로 다른 가열원을 가진 세 가지 방법으로 제작을 하여 시간에 따른 온도 프로파일을 조사함으로써 그 성능을 평가하였고, 이를 이용하여 사출성형품을 제조하여 수축률, 밀도, 표면 거칠기, Weld line등을 측정하여 실용적인 적용 가능성을 조사 하였다. 가열시간($130^{\circ}C$ 도달시간 14초) 및 사이틀 타임(55초)은 실용화가 가능한 수준으로 나타났다. 일반 사출성형방식으로 성형한 제품과 비교했을 때 수축률은 전열을 이용한 가열방식으로 사출한 성형품이 5.1% 감소하였고, 밀도는 2.66% 증가하였다. 표면 거칠기는 3배 이상 향상 되었고, 일반 사출에서 나타나던 Weld line은 전열가열방식에서는 나타나지 않았다.

  • PDF