• Title/Summary/Keyword: heating temperature and time

Search Result 1,377, Processing Time 0.034 seconds

Heating Performance Characteristics of Heat Pump with VI cycle using Re-Heater and Solar-Assisted (태양열과 재열기를 사용한 VI heat pump의 성능 특성에 관한 연구)

  • Lee, Jin-Kook;Choi, Kwang-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.6
    • /
    • pp.25-33
    • /
    • 2015
  • In this study, heating performance of the air-cooled heat pump with vapor-injection (VI) cycles, re-heater and solar heat storage tank was investigated experimentally. Devices used in the experiment were comprised of a VI compressor, re-heater, economizer, variable evaporator, flat-plate solar collector for hot water, thermal storage tank, etc. As working fluid, refrigerant R410A for heat pump and propylene glycol (PG) for solar collector were used. In this experiment, heating performance was compared by three cycles, A, B and C. In case of Cycle B, heat exchange was conducted between VI suction refrigerant and inlet refrigerant of condenser by re-heater (Re-heater in Fig. 3, No. 3) (Cycle B), and Cycle A was not use re-heater on the same operating conditions. In case of Cycle C, outlet refrigerant from evaporator go to thermal storage tank for getting a thermal energy from solar thermal storage tank while re-heater also used. As a result, Cycle C reached the target temperature of water in a shorter time than Cycle B and Cycle A. In addition, it was founded that, as for the coefficient of heating performance($COP_h$), the performance in Cycle C was improved by 13.6% higher than the performance of Cycle B shown the average $COP_h$ of 3.0 and by 18.9% higher than the performance of Cycle A shown the average $COP_h$ of 2.86. From this results, It was confirmed that the performance of heat pump system with refrigerant re-heater and VI cycle can be improved by applying solar thermal energy as an auxiliary heat source.

Behaviour of Condensing Gaseous Species under Various Operating Conditions in a Combustion Facility (환경조건변화에 따른 응축성 가스상 물질의 거동특성)

  • Kim, Yong-Gu;Bong, Choon-Keun;Song, Gyu-Young;Lee, Myong-Hwa
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.29 no.5
    • /
    • pp.634-641
    • /
    • 2013
  • Condensing species behaviour downstream of a combustor was discussed with particle size distribution in this study. The effects of operating conditions in a biomass combustion facility, i.e. concentration of condensing species, temperature gradient, residence time and injection of adsorbents, on particle size distribution were investigated. Pyroligneous liquid which was completely vaporized at the temperature higher than $350^{\circ}C$ was used as a representative of condensing gaseous species. We found that particle size downstream of a combustor increased with increasing heating temperature (i.e. concentration of condensing species) and residence time. However, temperature gradient was not an important factor to control the particle size. The addition of $SiO_2$ precursor as an adsorbent could effectively prevent the particle formation by adsorbing condensing gaseous species on $SiO_2$ particles, and increased the particle size up to 300 nm, resulting in increasing particle removal efficiency in a conventional air pollution control device.

Investigation of the observed solar coronal plasma in EUV and X-rays in non-equilibrium ionization state

  • Lee, Jin-Yi;Raymond, John C.;Reeves, Katharine K.;Shen, Chengcai;Moon, Yong-Jae
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.43 no.1
    • /
    • pp.53.1-53.1
    • /
    • 2018
  • During a major solar eruption, the erupting plasma is possibly out of the equilibrium ionization state because of its rapid heating or cooling. The non-equilibrium ionization process is important in a rapidly evolving system where the thermodynamical time scale is shorter than the ionization or recombination time scales. We investigate the effects of non-equilibrium ionization on EUV and X-ray observations by the Atmospheric Imaging Assembly (AIA) on board Solar Dynamic Observatory and X-ray Telescope (XRT) on board Hinode. For the investigation, first, we find the emissivities for all the lines of ions of elements using CHIANTI 8.07, and then we find the temperature responses multiplying the emissivities by the effective area for each AIA and XRT passband. Second, we obtain the ion fractions using a time-dependent ionization model (Shen et al. 2015), which uses an eigenvalue method, for all the lines of ion, as a function of temperature, and a characteristic time scale, $n_et$, where $n_e$ and t are density and time, respectively. Lastly, the ion fractions are multiplied to the temperature response for each passband, which results in a 2D grid for each combination of temperature and the characteristic time scale. This is the set of passband responses for plasma that is rapidly ionized in a current sheet or a shock. We investigate an observed event which has a relatively large uncertainty in an analysis using a differential emission measure method assuming equilibrium ionization state. We verify whether the observed coronal plasmas are in non-equilibrium or equilibrium ionization state using the passband responses.

  • PDF

Design of an Inexpensive Heater using Chip Resistors for a Portable Real-time Microchip PCR System (저항소자를 이용한 휴대형 Real-time PCR 기기용 히터 제작)

  • Choi, Hyoung-jun;Kim, Jeong-tae;Koo, Chi-wan
    • Journal of IKEEE
    • /
    • v.23 no.1
    • /
    • pp.295-301
    • /
    • 2019
  • A heater in a portable real-time polymerase chain reaction(PCR) system is one of the important factors for controlling the PCR thermocycle precisely. Since heaters are integrated on a small-sized PCR chip for rapid heating and fabricated by semiconductor processes, the cost of producing PCR chips is high. Here, we propose to use chip resistors as an inexpensive and accurate temperature control method. The temperature distribution was simulated using one or two chip resistors on a real-time PCR chip and the PCR chip with uniform temperature distribution was fabricated. The temperature rise and fall rates were $18^{\circ}C/s$ and $3^{\circ}C/s$, respectively.

An experimental study of heat transfer with $Na_4P_2O_7{\cdot}10H_2O$ as P.C.M. ($Na_4P_2O_7{\cdot}10H_2O$의 축열방열시 열전달 특성에 관한 실험적 연구)

  • Lee, C.M.;Yim, C.S.
    • Solar Energy
    • /
    • v.9 no.1
    • /
    • pp.70-77
    • /
    • 1989
  • Sodium pyrophosphate that melting point is $79-80^{\circ}C$ have been Studied on heat storage and heat discharge. In heat storage process, sodium pyrophosphate was kept up initial temperature $50^{\circ}C,\;60^{\circ}C,\;70^{\circ}C$ which melt by heated water at temperature $85^{\circ}C,\;90^{\circ}C,\;95^{\circ}C$. In heat discharge process, initial temperature of sodium pyrophosphate was maintained at temperature $85^{\circ}C,\;90^{\circ}C,\;95^{\circ}C$ which varied cooling temperature $50^{\circ}C,\;60^{\circ}C,\;70^{\circ}C$. The experiment has been reached conclusions as follows. 1) Heat transfer properties of phase change material is controlled by conduction during heating and cooling process. 2) The temperature increased rapidly at initial stage and transient region increase slowly because of characteristic of latent heat. 3) The lower cooling water temperature is the less the time that get to thermal equivalent state take during discharge process. 4) The higher cooling water temperature is the less temperature difference between top and bottom in P.C.M during discharge process.

  • PDF

Influence of Holding Methods and Times on Recovery of Salmonella Typhimurium in Simmered Pork and Ham at Cucumber Salad Served at Foodservice Institutions (급식소에서 제공되는 돼지고기 장조림과 햄ㆍ오이샐러드의 조리 후 보관방법 및 시간이 살모넬라(Salmonella typhimurium) 식중독균의 생존에 미치는 영향)

  • 고성희;김지영
    • Korean journal of food and cookery science
    • /
    • v.20 no.4
    • /
    • pp.352-357
    • /
    • 2004
  • This study was performed to predict the multiplication growth patterns of Salmonella typhimurium according to the holding methods and times in cooked foods served at foodservice institutions. When simmered pork in soy sauce and ham and cucumber salad were inoculated with S. typhimurium (7.00 logCFU/g) and tested according to holding methods and times, room temperature holding showed a continuous increase in S. typhimurium count as time passed, whereas 80$^{\circ}C$ heating table sharply reduced the count to 4.00 (logCFU/g) after 2hrs of holding and to zero after 6hrs, which suggested that all S. typhimurium were destroyed. However, 5$^{\circ}C$ refrigerator holding showed a count increase, although it wasis still lower than that at room temperature and at 10$^{\circ}C$ cold table holding, which suggested that S. typhimurium is comparatively resistive to low temperature.

Field Application of a Latent Heat Storage Tank for Load Shaving of Domestic Hot Water Supply in District Heating (지역난방 급탕공급 부하균등화를 위한 잠열축열조의 현장 적용)

  • Park, Sung Yong;Yoo, Hoseon
    • Plant Journal
    • /
    • v.17 no.2
    • /
    • pp.42-47
    • /
    • 2021
  • In terms of district heating operation, efficient production and supply of heat by alleviating the peak load at a specific time require an application technology that can solve the inconvenience of the user and the difficulties of the supplier. In this study, a 78 ℃ class PCM heat storage tank suitable among the technologies that can solve these problems was manufactured and applied to the hot water supply facility for apartments in district heating users. As a result of the application of this system, it was confirmed that the supply temperature was constant to the user compared to the existing supply method. In addition, it was confirmed that the reduction of the peak load due to load equalization reduced the heat supply margin of 10% in the existing heat supply facility. And the construction cost of the new heat supply facility and the construction cost of heat users is decreased by 5% and 10%, respectively.

A study on the Shrinkage Properties of precast concrete using Calcium hardening accelerator (칼슘계 경화촉진제를 사용한 프리캐스트 콘크리트의 수축특성에 관한 연구)

  • Min, Tae-Beom;Jo, In-Seong;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.11a
    • /
    • pp.44-45
    • /
    • 2014
  • On this study, initial crack index was evaluated by performing FEM analysis to crack propagation from hydration heat for development of precast concrete. On the result, as increased the usage of hardening accelerator, initial compressive strength were improved and setting time also was shortened. Additionally, central temperature of concrete was increased, the reaching time for the highest temperature could be shortened. By the result to assess crack index, there was no problem about crack despite of growth of initial high hydration heating. This result guessed because of small size element when analyzed trough FEM, realization for mass concrete's crack index should be performed.

  • PDF

Quality Characteristics of Pan Bread Depending on the Time of Microwave Irradiation Time (Microwave 조사 시간에 따른 식빵의 품질 특성)

  • Park, Sang-Jun;An, Hye-Lyung;Lee, Kwang-Suck
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.20 no.3
    • /
    • pp.423-432
    • /
    • 2010
  • In order to streamline bread making process that is time-consuming in regard to the characteristics of process, this study focused on microwave irradiation to dough and raising its temperature to monitor potential variations of dough properties and bread quality, and also examined optimum irradiation time to deduce effective ways for streamlining bread making process. According to analyze dough properties depending on microwave irradiation time, it was found that microwave heat (MWH) 2 showed the highest specific volume and oven spring of all and the lowest hardness (i.e. the highest softness). Moreover, MWH 2 scored the highest points in overall preference under sensory characteristics. As a result, it found that 80-second heating of 700 g bread dough, when exposed to microwave irradiation, contributed to the highest quality of bread.

Pore Structure of Cement Matrix Exposed to High Temperatures (고온하의 시멘트 경화체의 공극구조)

  • 송훈;도정윤;소승영;소양섭
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.11a
    • /
    • pp.509-512
    • /
    • 2003
  • Dehydration and micro crack thermal expansion occur in cement hydrates of concrete structure heated by fire for a long time. The characteristic of concrete exposed to high temperature can be analyzed from distribution of porosity and pore size. Porosity showed a tendency to increase irrespective of specimen types. This is due to both the outbreak of collapse of gel comprising the cement and a micro crack by heating. Porosity did not affect the variety of specimen and increased with the same tendency throughout every specimen. In addition, the deteriorate of compressive strength resulted from increase in porosity

  • PDF