• Title/Summary/Keyword: heating performance

Search Result 1,973, Processing Time 0.031 seconds

Isolation of Alliin in Garlic and Its Quantitative Determination by High Performance Liquid Chromatography and Studies on the Antimicrobial Efforts of Alliin and Ethanol Extracts from Korean Garlic(Alliium sativum L.) (마늘 중 고속 액체 크로마토그래피에 의한 알린의 분리 및 정량과 Alliin과 에탄올 추출물의 항균효과에 관한 연구)

  • 위성언
    • The Korean Journal of Food And Nutrition
    • /
    • v.16 no.4
    • /
    • pp.296-302
    • /
    • 2003
  • First. the purification and analysis of alliin in garlic from different origins by alliin-HPLC determination method were studied. Allinase in garlic was inactivated by heating in boiling water followed by extraction of alliin in garlic with 80% methanol. To remove free amino acids and alliin homologs in garlic, garlic extract was separated by cation exchange column which was packed with amberlite CG-120 resin using 40L d-water as eluent. Alliin in garlic extract was crystallized in a mixture of acetone (50$^{\circ}C$):H$_2$O:acetic acid=70:29:1 and then recrystallized in a mixture of acetone (50$^{\circ}C$):H$_2$O:acetic acid=75:24:1. Obtained alliin was identified by melting point. TLC, microscope observation and mass spectrometry. High performance liquid chromatography (HPLC) following pre-column derivatization of cystein derivatives with o-phthaldialdehyde/2-mercaptoethanol has succeessfully been applied to the analysis of various garlics. Each alliic of standard solution and garlic extract was derivatized to isoindole derivative by o-phthaldialdehyde /2-mercaptoethanol and then analyzed by HPLC. Six point calibration was done by using alliin peak area. Lineality was observed at 0 ∼ 1.0mg/ml of alliin concentration. Weighted regression line function was Y=6254X - 256077. By this function, alliin contents in various garlics were 0.34 ∼ 0.73% fresh weight. Second study was designed to evaluate the effects of garlic extracts of various concentrations on the growth of various pathogenes (Eubacterium limonsum, Bacteroides fragilis, Salmonella typhimurium, Salmonella typhi, Shigella sonnei, Kiebsiella pneumoniae, Enterobacter cloacae, Pserdomonas aeruginosa, Escherichia coli). For antimicrobial effects against microorganism, totally minimal inhibition concentrations (MIC) of alliin were from 5,000 to 20,000ppm. MIC of ethanol extract were 1,250 to 10,000ppm.

Development of Thermoluminescence and Optical Stimulated Luminescence Measurements System (열자극발광 및 광자극발광 측정장치의 개발)

  • Park, Chang-Young;Chung, Ki-Soo;Lee, Jong-Duk;Chang, In-Su;Lee, Jungil;Kim, Jang-Lyul
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.1
    • /
    • pp.46-54
    • /
    • 2015
  • The thermoluminescence (TL) and optically stimulated luminescence (OSL) are commonly used to measure and record the expose of individuals to ionization radiation. Design and performance test results of a newly developed TL and OSL measurement system are presented in this paper. For this purpose, the temperature of the TL material can be controlled precisely in the range of $1{\sim}1.5^{\circ}C$ by using high-frequency (35 kHz) heating system. This high-frequency power supply was made of transformer with ferrite core. For optical stimulation, we have completed an optimal combination of the filters with the arrangement of GG420 filter for filtering the stimulating light source and a UG11 filter at the detecting window (PMT). By using a high luminance blue LED (Luxeon V), sufficient luminous intensity could be obtained for optical stimulation. By using various control boards, the TL/OSL reader device was successfully interfaced with a personal computer. A software based on LabView program (National Instruments, Inc.) was also developed to control the TL/OSL reader system. In this study, a multi-functional TL/OSL dosimeter was developed and the performance testing of the system was carried out to confirm its reliability and reproducibility.

Thermal Performance of Air Receiver filled with Porous Material for $5kW_t$ Dish Solar Collector (공기식 흡수기를 이용한 5kW급 접시형 태양열 집열기의 열성능 해석)

  • Seo, Joo-Hyun;Ma, Dae-Sung;Kim, Yong;Seo, Tae-Beom;Kang, Yong-Heack;Lee, Sang-Nam;Han, Gui-Young
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.570-575
    • /
    • 2007
  • The thermal performance of the air receiver filled with porous material for 5kWt dish solar collector installed in Inha University, Korea, is experimentally investigated. The diameter of the parabolic dish is 3.2 m, and its focal length is 2 m. It consists of 10 small pieces of glasses which have their own curvatures, and the effective reflecting area is 5.9 m2. The reflectivity of the glass is 0.95, and the thermal capacity of the system is about 5 kW thermal. The aperture diameter of the cylindrical-shape receiver which is made of stainless steel is 100 mm, and the height is 210 mm. A quartz window is installed at the receiver aperture to minimize the convective heat loss and prevent air leakages. In order to increase the heat transfer area, porous material (nickel-alloy) is inserted into the receiver. Air flows into the upper part of the receiver, which is the opposite side of the aperture. After the air flows through the inside receiver, that goes out of the receiver through 3 exits which are located near the aperture. The volumetric flow rates of air are varied from 600 to 1200 L/min. The thermal efficiency of the receiver ranges from 82% - 92% depending upon the flow rate. The results show that the system efficiency and receiver efficiency increase as the volume flow rate increases as expected. These results from the experiment will be useful for the applications to air heating receivers and solar reactors.

  • PDF

Effect of Coolants and Metal Bumps on the heat Removal of Liquid Cooled Microchannel System (액랭식 마이크로채널 시스템 내 냉매와 범프의 열 제거 효과에 대한 연구)

  • Won, Yonghyun;Kim, Sungdong;Kim, Sarah Eunkyung
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.24 no.2
    • /
    • pp.61-67
    • /
    • 2017
  • As transistor density increases rapidly, a heat flux from IC device rises at fast rate. Thermal issues raised by high heat flux cause IC's performance and reliability problems. To solve these thermal management problems, the conventional cooling methods of IC devices were reached their thermal limit. As a result, alternative cooling methods such as liquid heat pipe, thermoelectric cooler, thermal Si via and etc. are currently emerging. In this paper microchannel liquid cooling system with TSV was investigated. The effects of 2 coolants (DI water and ethylene glycol 70 wt%) and 3 metal bumps (Ag, Cu, Cr/Au/Cu) on cooling performance were studied, and the total heat flux of various coolant and bump cases were compared. Surface temperature of liquid cooling system was measured by infrared microscopy, and liquid flowing through microchannel was observed by fluorescence microscope. In the case of ethylene glycol 70 wt% at $200^{\circ}C$ heating temperature, the total heat flux was $2.42W/cm^2$ and most of total heat flux was from liquid cooling effect.

Composting Effectiveness of A Sundry System with A Bin-type Composter for Recyle of Animal Wastes (축분뇨처리를 위한 Bin형 부숙조- Sundry 시스템의 퇴비화효율 평가)

  • 최홍림;김현태;정영윤
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.35 no.2
    • /
    • pp.92-103
    • /
    • 1993
  • A sunday system with a horizontal bin-type composter was constructed and operated to evaluate its composting performance for four days for each test in October, 1992. A sundry system is one of popular systems for composting livestock manure, of which main benefit is to utilize unlimited, clean, and free solar radiation. A rectangular concrete bin(composter) with dimension of 300cm(length) X90cm(width) X60cm(height) was bedded alternatively with four lanes of aeration pipes and heating pipes, and was insulated at three walls with 50mm styrofoam. Each aeration pipe of a diameter of 25mm had 4mm perforated holes at every 15cm longitudinally, and supplied air of about 2m$^3$/min to the composter to maintain aerobic condition . A stirrer rotating at 1 rpm made one round trip every 20 minutes on the conveying chain along the the length of the composter. Five tests (Test 1~Test 5) were implemented to evaluate the composting effectiveness of a sundry system with a horizontal bin-type composter. Treatments of two levels of the mixture ratio of swine manure and paper sludge cakes(manure : paper sludge cakes= 1 : 4 and 1 : 2) and two levels of the water content(W/C ; 70% and 50%) were made to test the significance of the physicochemical properties for decomposition of the mixture materials. Temperature, C/N ratio, water content, microbial activity of the composting materials were taken measurements to evaluate its performance with the lapse of composting time for tests. A small-scale sundry system with a bin-type composter did not appear to be an appropriate system for composting livestock manure. Since heat generation by the composting materials could not overcome heat loss due to areation in a small-scale composter, a proper thermal enviroment could not be maintained to propagate massively thermopilic microorganism relatively in a short period of time. Different from the result of Chol et al.(1992) 6), a temperature variation of the composting materials did not show the peak clearly and C/N ratio didn't lower with time as expected. Mesophilic microoragnism seemed to play an important role for decomposition of the mixture materials. A sundry system with a bin-type composter may be good for a large-scale livestock farm household which may produce enough animal manure. Therefore a decision should be made very carefully to choose a system for composting livestock waste.

  • PDF

Drying seaweeds using hybrid hot water Goodle dryer (HHGD): comparison with freeze-dryer in chemical composition and antioxidant activity

  • Nagahawatta, D.P.;Asanka Sanjeewa, K.K.;Jayawardena, Thilina U.;Kim, Hyun-Soo;Yang, Hye-Won;Jiang, Yunfei;Je, Jun-Geon;Lee, Tae-Ki;Jeon, You-Jin
    • Fisheries and Aquatic Sciences
    • /
    • v.24 no.1
    • /
    • pp.19-31
    • /
    • 2021
  • Seaweeds are a potential source of minerals, essential amino acids, fatty acids, proteins, and various bioactive compounds such as antioxidants. The higher water content of seaweeds reduces the shelf life and this requires the appropriate drying method. The drying conditions play a major role in the conservation of nutrient composition in dried seaweeds. In recent years, the seaweed industry has used many different drying methods with advantages and limitations. Hybrid hot-water Goodle dryer (HHGD) which is a special dryer mixed with hot-water and a Korean traditional heating system (Goodlejang) might be a solution to avoid these limitations. The present study evaluated the effect of drying conditions in HHGD on nutrient composition and bioactivities of brown seaweeds. Moreover, freeze-dryer (FD) and HHGD were employed in this study to compare the dried outputs obtained from four brown seaweed species. The present study aims to evaluate the effect of the hybrid hot-water Goodle drying method (HHGDM) on the nutritional composition and antioxidant activity of dried seaweeds. AOAC standard methods were used to analyze the proximate composition of dried samples and their 70% ethanol extract. The intracellular and extracellular antioxidant activities were evaluated using Vero cells and electron spin resonance (ESR) spectrometer respectively. High performance liquid chromatography, apoptotic body formation, and in-vivo experiments were used for further confirmation of the quality of dried output. The proximate composition results obtained from drying in HHGD and FD did not exhibit any significant difference. Moreover, the seaweed extracts from the dried seaweeds by HHGD and FD dryings were also not different and both significantly down-regulated in-vivo and in-vitro oxidative stress. Furthermore, the high performance liquid chromatography results revealed that the two dryers did not make the major peaks different in the chromatograms. Freeze-drying method (FDM) provides elevated quality for dried output, but there are limitations such as high cost and low capacity. The results from a novel HHGD did not provide any significant difference with the results in FD and expressed a potential to avoid the limitations in FD. Overall, these findings solidified the applicability of HHGD over FD.

A Study on the Non-combustible Properties of High-density Fiber Cement Composites Mixed with Hemp Fibers (마 섬유 혼입에 따른 고밀도 섬유 시멘트 복합체의 불연 특성 연구)

  • Jang, Kyong-Pil;Song, Tae-Hyeob
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.10 no.3
    • /
    • pp.314-320
    • /
    • 2022
  • The function of reinforcing fibers used in building materials is to maintain resistance to bending loads and to function for cracking caused by drying shrinkage. High-density fiber-cement composites are mainly used for linear plates and are used to increase bending resistance. Therefore, tensile properties, bonding strength with cement hydrate, alkali resistance, and the like are required. Recently, as the non-combustible performance has been strengthened, a function to minimize the occurrence of sparks during high-temperature heating has been added. Therefore, the use of organic fibers is limited. In this study, a study was conducted to replace polypropylene used as reinforcing fiber with hemp fiber with excellent heat resistance. Hemp fibers have excellent heat resistance, good affinity with cement, and excellent alkali resistance. Based on the total volume of polypropylene fibers used in the existing formulation, the non-combustible performance was compared and evaluated by using hemp fibers instead of the polypropylene fibers, and basic physical properties such as flexural strength were tested. As a result of conducting a non-combustibility and physical property test using hemp fibers with a fiber length of 7 mm using 2 % and 3 % by weight, it was found that there is no remaining time of the flame, and the flexural strength can be secured at 95 % level of the existing polypropylene fiber.

Flash Lamp Annealing of Ag Organometallic Ink for High-Performance Flexible Electrode (플래시 기반 유기금속화합물 열처리를 통한 고성능 유연 전극 제조)

  • Yu Mi Woo;Dong Gyu Lee;Yun Sik Hwang;Jae Chan Heo;SeongMin Jeong;Yong Jun Cho;Kwi-Il Park;Jung Hwan Park
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.36 no.5
    • /
    • pp.454-462
    • /
    • 2023
  • Flash lamp annealing (FLA) of metal nanoparticle (NP) ink has provided powerful strategies to fabricate high-performance electrodes on a flexible substrate because of its rapid processing capability (in milliseconds), low-temperature process, and compatibility with to roll-to-roll process. However, metal NPs [e.g., gold (Au), silver (Ag), copper (Cu), etc.] have limitations such as difficulty in synthesizing fine metal NPs (diameter less than 10 nm), high price, and degradation during ink storage and FLA processing. In this regard, organometallic ink has been proposed as a material that can replace metal NPs due to their low-cost (usually 1/100 times cheaper than metal nano inks), low-temperature processability, and high material stability. Despite these advantages, the fabrication of flexible electrodes through FLA treatment of organometallic compounds has not been extensively researched. In this paper, we experimentally guide how to determine the optimal conditions for forming electrodes on flexible substrates by considering material parameters, and flashlight processing parameters (energy density, pulse duration, etc) to minimize the difficulties that may arise during the FLA of organometallic ink.

Current Status of Sanitation Management Performance in Korean-Food Restaurants and Development of the Sanitary Training Posters Based on their Risk Factors (한식당의 위생관리 현황 평가 및 위험요인 중심의 위생교육용 포스터 개발)

  • Kim, Sun-Jung;Yi, Na-Young;Chang, Hye-Ja;Kwak, Tong-Kyung
    • Journal of the Korean Society of Food Culture
    • /
    • v.23 no.5
    • /
    • pp.582-594
    • /
    • 2008
  • This study aimed at evaluating current sanitation management performances in Korean-Food restaurants by their operation types and to develop sanitary training posters based on the risk factors, in an attempt to improve the level of sanitation management in Korean food service facilities. Eighteen Korean-food restaurants that are managed by franchisor, franchisees as well as self-managed with large-scale and small-scale restaurants in Seoul and Gyeonggi-Do, were evaluated by on-the-spot inspectors with an auditing tool consisting of three dimensions, nine categories and thirty four items. Data were analyzed using SPSS. The total score of each group showed that restaurants managed by franchisees ranked the highest (59 out of 100 points), while self-managed, small-scale restaurants ranked the lowest (44 out of 100 points). In the categorization of sanitation management compliance, the dimensions of food hygiene during production recorded the lowest compliance rate of 47.7% (22.89/48.0 points) followed by the dimension of environmental hygiene 59.3% (20.17/34.0 points) and personal hygiene 60.5% (10.89/18.0 points). This indicated the need for urgent improvement. The items which showed the lowest compliance rates were 'proper thawing of frozen foods' (0%), 'notifying and observing heating/reheating temperature' (6%), 'using of hand-washing facility and proper hand-washing' (33%), 'monitoring temperature of frozen-foods and cold-foods' (35%), and 'prevention of cross-contamination' (36%) among thirty four items. Self-managed, small-scale restaurants, in particular, needed to improve sanitary practices such as 'sanitation education for employee', 'verifying the employee health inspection reports', 'storing food on the shelves 15 cm distance away from the wall', 'suitability of ventilation capacity of hoods' and 'cleanliness of drainage'. On the basis of the findings of this study, we developed sanitary training posters, especially for small-scale restaurant operators. This could be an effective tool to educate food service employees on sanitary knowledge and principles and could be used to improve the existing sanitary conditions in Korean food service facilities.

Recent Progress in Air Conditioning and Refrigeration Research - A Review of papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 1998 and 1999 - (공기조화, 냉동 분야의 최근 연구 동향 - 1998년 1999년 학회지 논문에 대한 종합적 고찰 -)

  • 이재헌;김광우;김병주;이재효;김우승;조형희;김민수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.12
    • /
    • pp.1098-1125
    • /
    • 2000
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering in 1998 and 1999 has been done. Focus has been put on current status of research in the aspect of heating, cooling, ventilation, sanitation and building environment. The conclusions are as follows. 1) A review of the recent studies on fluid flow, turbomachinery and pipe-network shows that many experimental investigations are conducted in applications of impingement jets. Researches on turbulent flows, pipe flows, pipe-networks are focused on analyses of practical systems and prediction of system performance. The results of noise reduction in the turbomachinery are also reported. 2) A review of the recent studies on heat transfer analysis and heat exchanger shows that there were many papers on the channel flow with the application to the design of heat exchanger in the heat transfer analysis. Various experimental and numerical papers on heat exchanger were also published, however, there were few papers available for the analysis of whole system including heat exchanger. 3) A review of the recent studies on heat pump system have focused on the multi-type system and the heat pump cycle to utilize treated sewage as the heat source. The defrosting and the frosting behaviors in the fin-tube heat exchanger is experimentally examined by several authors. Several papers on the ice storage cooling system are presented to show the dynamic simulation program and optimal operation conditions. The study on the micro heat pipes for the cooling of high power electronic components is carried out to examine the characteristics of heat and mass transfer processed. In addition to these, new type of separate thermosyphon is studied experimentally. 4) The recent studies on refrigeration/air conditioning system have focused on the system performance and efficiency for new alternative refrigerants. New systems operating with natural refrigerants are drawing lots of attention. In addition to these, evaporation and condensation heat transfer characteristics of traditional and new refrigerants are investigated for plain tubes and also for microfin tubes. Capillary tubes and orifice are main topics of research as expansion devices and studies on thermophysical properties of new refrigerants and refrigerant/oil mixtures are widely carried out. 5) A review of the recent studies on absorption cooling system shows that numerous experimental and analytical studies on the improvement of absorber performance have been presented. Dynamic analysis of compressor have been performed to understand its vibration characteristics. However research works on tow-phase flow and heat transfer, which could be encountered in the refrigeration system and various phase-change heat exchanger, were seemed to be insufficient. 6) A review of recent studies on duct system shows that the methods for circuit analysis, and flow balancing have been presented. Researches on ventilation are focused on the measurement of ventilation efficiency, and variation of ventilation efficiency with ventilation methods by numerous experimental and numerical studies. Furthermore, many studies have been conducted in real building in order to estimate indoor thermal environments. Many research works to get some information for cooling tower design have been performed but are insufficient. 7) A review on the recent studies on architectural thermal environment and building mechanical systems design shows that thermal comfort analysis is sitting environment, thermal performance analysis of Korean traditional building structures., and evaluation of building environmental load have been performed. However research works to improve the performance of mechanical system design and construction technology were seemed to be insufficient.

  • PDF