• 제목/요약/키워드: heating energy

검색결과 3,237건 처리시간 0.026초

창의 기울기에 따른 건축물 에너지 소비량 예측 (The Prediction of Energy Consumption by Window Inclination)

  • 조성우
    • 한국태양에너지학회 논문집
    • /
    • 제31권5호
    • /
    • pp.27-32
    • /
    • 2011
  • Most of domestic building generally don't have fixed shading devices considering of appearance and aesthetic issues. In this study is suggested that tilt window simultaneously has a role of shading and blocking solar radiation. The tilt window thermal performance is investigated by relation ship between inclination and heating cooling road. As comparing vertical window with $5^{\circ}$ and $7^{\circ}$ of tilt window respectively, the heating load is increased by 3.6% and cooling load is reduced by 8.1% on $5^{\circ}$ tilt window and the heating load is increased by 5.3% and cooling load is reduced by 11.5% on $5^{\circ}$ tilt window. Especially, the total load of alternative tilt window is showed the reduction rate 2.6% and3.6% compared of vertical window. Therefore, the tilt window is possible to role of shading of solar radiation and reduction of heating and cooling load.

공기 열원을 이용한 축열식 냉난방 시스템 연구 (A Study on the Energy Storage System Using Air Source Heat Pump for Heating and Cooling)

  • 김욱중;이공훈;서정균
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.1125-1130
    • /
    • 2006
  • An air source heat pump system producing the ice and water storage energy for cooling and heating of building has been proposed. Cycle design and simulation considering energy balance between heating and cooling capacity has been carried out. The roles of the capacity controlled compressor, refrigerant heating device and air preheating are investigated in detail. System control logic for meeting the predetermined heating capacity when the system is operated at cold climate condition is suggested. Some anticipated problems of the proposed system are also described.

  • PDF

BES 기법을 이용한 자연환기식 육계사의 난방에너지 분석 (Analysis of Heating Load of a Naturally Ventilated Broiler House using BES Simulation)

  • 홍세운;이인복;홍희기;서일환;황현섭;;유재인;권경석;하태환;김기성
    • 한국농공학회논문집
    • /
    • 제50권1호
    • /
    • pp.39-47
    • /
    • 2008
  • Most of the broiler houses in Korea have experienced problems on controlling the environmental conditions such as suitability, stability and uniformity of rearing condition inside the broiler house. It is very critical which if not properly controlled, would cause serious stress on the chickens. It is therefore urgent to develop optimum designs of naturally ventilated broiler house which is appropriate to the four seasons of Korea. Field experiment for this matter is very difficult to conduct due to the unpredictable and uncontrollable weather condition. In this study, the heating load of a naturally ventilated broiler house was calculated using TRANSYS 15 BES program while internal climate and thermal condition were computed using Fluent 6.2. The computed resulted of the conventional ventilation system (A) and upgraded ventilation system (B) (Seo et al, 2007) were compared with each other for cold season. The results of the Building Energy Simulation(BES) indicated that the system B, the upgraded ventilation system made 8% lower total heating load and 47% lower at only the broiler zone compared to the conventional broiler house. Considering the entire broiler house, the existence of middle ceiling made the heating energy 11% lower required than without middle ceiling. Accordingly, the system B with middle ceiling was found to save heating energy by 20% in average. This study showed that the BES program can be a very powerful to effectively compute the energy loads of agricultural building while the energy load is very close related to ventilation efficiency.

초음파 펄스 서모그라피를 이용한 세라믹 전열 판의 결함 검출 (Defect Detection of Ceramic Heating Plate Using Ultrasound Pulse Thermography)

  • 조재완;서용칠;정승호;김승호;정현규
    • 한국세라믹학회지
    • /
    • 제43권4호
    • /
    • pp.259-263
    • /
    • 2006
  • The applicability of UPT (Ultrasound Pulse Thermography) for real-time defect detection of the ceramic heating plate is described. The ceramic heating plate with superior insulation and high radiation is used to control the water temperature in underwater environment. The underwater temperature control system can be damaged owing to the short circuit, which resulted from the defect of the ceramic heating plate. A high power ultrasonic energy with pulse duration of 280 ms was injected into the ceramic heating plate in the vertical direction. The ultrasound excited vibration energy sent into the component propagate inside the sample until they were converted to the heat in the vicinity of the defect. Therefore, an injection of the ultrasound pulse wave which results in heat generation, turns the defect into a local thermal wave transmitter. Its local emission is monitored and recorded via the thermal infrared camera at the surface which is processed by image recording system. Measurements were Performed on 4 kinds of samples, composed of 3 intact plates and the defect plate. The observed thermal image revealed two area of crack in the defective ceramic heating plate.

열 파이프용 수평 축열조에서의 열 입력이 축열에 미치는 영향 (An Effect of Heat Input on Thermal Storage for Horizontal Thermal Storage Tank with Heat pipe)

  • 박이동;정운철
    • 태양에너지
    • /
    • 제16권2호
    • /
    • pp.39-47
    • /
    • 1996
  • 본 연구에서는 실제 열 파이프용 수평 축열조에서 등간격인 heating pad 수와 위치 및 공급열량을 변화시키면서 축열조내의 순수 Plume 유동특성을 파악하였다. 동일한 heating pad수를 가지고 집중 배치 형태와 분산 배치 형태를 취하였을 때 집중 배치 형태로 취하는 것이 $5{\sim}6%$ 정도의 더 높은 효율을 얻었다. 따라서 열 파이프용 수평 축열조에서 heating pad를 장착할 때 동일한 heating pad의 수에서는 집중(concentration)배치형태로 설계하는 것이 효과적임을 알 수 있다.

  • PDF

탄소나노히팅파이프를 이용한 온실 난방에너지 절감효과 (Energy Saving Effects of Carbon Nano Heating Pipe for Heating of Greenhouse)

  • 백이;전종길;윤남규
    • 한국기계기술학회지
    • /
    • 제13권3호
    • /
    • pp.107-111
    • /
    • 2011
  • This carbon nano heating system was consisted of power supply equipment, a carbon fiber and a stainless flexible hose. carbon nano heating system was manufactured by carbon fiber of a power capacity 30kw/h and light-oil hot air heater in control plot was the heating capacity 30,000kcal/h, As the result, Temperature difference due to carbon nano heating system and hot air heater in greenhouse showed that air temperature at experimental greenhouse, comparison greenhouse were $14.8^{\circ}C$, $13.4^{\circ}C$ respectively. It was found that carbon nano heating system and light-oil hot air heater heating cost were 1,095,740won, 2,683,628won. therefore as heating cost saving 60%. Yield of tomatoes cultured in greenhouse using carbon nano heating pipe was 4% inclease. Economic analysis comparison between the carbon nano heating pipe and the hot air heater in greenhouse were 41% respectively.

중앙난방 시스템의 최적제어 알고리즘의 적용을 위한 실험적 연구 (An experimental study on the optimal control algorithm for central heating system)

  • 안병천;천원익
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.463-468
    • /
    • 2005
  • An experimental study on the optimal control algorithm for central heating system for minimizing energy consumption while maintaining the comfort of indoor thermal en vironment in terms of the environmental variables such as loads and weather. experimental study has been done by one using the prototype of central heating system. As a result the optimal control algorithm shows good energy performance in comparison with conventional control one.

  • PDF

KDHA Photo

  • 한국지역난방협회
    • 집단에너지
    • /
    • 통권5호
    • /
    • pp.6-15
    • /
    • 2007
  • PDF

CEO초대석

  • 한국지역난방협회
    • 집단에너지
    • /
    • 통권5호
    • /
    • pp.29-31
    • /
    • 2007
  • PDF