• 제목/요약/키워드: heating energy

검색결과 3,237건 처리시간 0.031초

환기량의 주거건물 냉난방에너지 소비에 대한 영향 : 미국 한랭기후 및 고온다습기후의 단독주택을 중심으로 (Ventilation Rate Impact on Heating and Cooling Energy Consumption in Residential Buildings : Concentrated on a Detached House in Cold and Hot/Humid Climatic Zones of USA)

  • 문진우
    • 설비공학논문집
    • /
    • 제23권11호
    • /
    • pp.747-753
    • /
    • 2011
  • The purpose of this study was to quantify the impact of the ventilation rate on heating and cooling energy consumption in a detached house. For it, a series of simulations for the application of the diverse ventilation rate (ACH) were computationally conducted for a prototypical detached residential building in the cold climate (Detroit, Michigan) and hot/humid climate (Miami, Florida) of USA. Analysis revealed that ventilation is a significant heat losing source in the cold climate; thus, the higher ventilation rate significantly increases the heating energy consumption and energy cost in the cold climate; while the impact on energy increase for heating and cooling energy consumption is similar in hot/humid climate with less significancy compared to cold climate. The research outcome of this study could be a fundamental data for determining the optimal ventilation rate in terms of indoor air quality, but also building energy performance well.

Comparative study on the effect of cooling & heating loads by lighting energy of various light sources in an office building

  • Hong, Won Pyo
    • 조명전기설비학회논문지
    • /
    • 제30권3호
    • /
    • pp.94-105
    • /
    • 2016
  • The objective of the work was to evaluate the impact of lighting energy to cooling and heating consumption in medium scale office building, when currently installed fluorescent lights were replaced with various LED lighting fixtures. This evaluation comes from an integrated approach combining the proper indoor lighting environment and the thermal aspects of cooling & heating consumption in office building. These simulations were performed by coupling an appropriate luminaire analysis for energy consumption and a dynamic thermal simulation software (TRNSYS). To analyze comparative study of effects on the heating, cooling loads, and energy consumption of an LED lamp application, 2 types of LED lamp with low light power watt(LPW) 24W and high LPW 7.5W and a fluorescent lights(FL) with 37W are used respectively. Integrated building energy consumption decreased up to 3.2% when fluorescent lamps were replaced with LEDs. Thus, the high LPW of LED(7.5W) replaced with the same number of FL shows an effective energy saving and cost- effective luminary.

공동주택 발코니창에 설치된 가동단열 시스템의 열성능 평가 (Thermal Performance Evaluation of Movable Insulation System in Apartments)

  • 윤종호;김병수
    • 한국태양에너지학회 논문집
    • /
    • 제28권5호
    • /
    • pp.28-35
    • /
    • 2008
  • The aim of this study was to analysis the Heating/cooling performance of movable insulation system built in apartments. The process of this study is as follows: 1) Test-cells of movable insulation are designed through the investigation of previous paper and work. The type of the movable insulation used in test-cell is low emissivity(5%) insulation, measured for heating season and the thermal effects are analyzed. 2) The simulation program(Design Builder) was used in energy performance analysis. the reference model of simulation was made up to analysis energy performance on movable insulation system. 3) Selected reference model(Floors:15, Area of Unit:115.5$m^2$) for heating/cooling energy analysis, Energy performance simulation with various variants, such as slate angle of movable insulation(5$^{\circ}$, 30$^{\circ}$, 50$^{\circ}$) and position of movable insulation. Consequently, When movable insulation system is equipped with balcony window of Apartment, Annual heating energy of reference model was cut down at the average of 5.4kWh/$m^2$ or 4.6% of heating/cooling energy.

농어촌 주택 표준모델의 냉난방에너지요구량 분석 (Heating and Cooling Energy Demand Analysis of Standard Rural House Models)

  • 이찬규;김우태
    • 한국산학기술학회논문지
    • /
    • 제13권8호
    • /
    • pp.3307-3314
    • /
    • 2012
  • 농어촌 주택 표준모델에 대한 연간 건물에너지요구량을 DesignBuilder를 사용하여 계산하였다. 실내설정온도, 외벽의 열관류율, 창호타입, 환기량을 변화시키며 건물의 설계/운영 변수들이 에너지요구량에 미치는 영향을 분석하였다. 건물의 크기와 상관없이 난방에너지요구량이 냉방에너지요구량보다 더 큰 것으로 나타났다. 단열재 두께를 증가시켜 외벽의 열관류율을 감소시키면 단열효과의 증가로 난방에너지요구량은 감소하지만 냉방에너지요구량이 증가한다. 하지만 외벽의 열관류율 조절을 통한 난방에너지요구량의 절감에는 한계가 있으므로 외부에 직접 노출된 외벽의 면적을 최소화하는 것이 더 효과적인 것으로 판단된다. 계산에 사용된 4가지 창호 중 일반 이중창호가 난방에너지요구량 측면에서 가장 유리한 것으로 나타났다. 침기량은 일정하게 유지하고 단위시간당 환기량을 증가시킨 경우 냉방에너지요구량은 큰 변화가 없었으나 난방에너지요구량이 증가하였다. 실내의 공기질이 만족되는 범위 내에서 환기량을 최소화하는 것이 연간 건물에너지요구량을 줄이는데 유리한 것으로 판단된다.

고온 및 방사선이 중성자 차폐재의 열적, 역학적 및 차폐능 특성에 미치는 영향 (Effects of High Temperature and Radiation on the Properties of Thermal, mechanical and Shielding Ability of Neutron Shielding Materials)

  • 조수행;홍순석;정명수;도재범;박현수
    • 한국재료학회지
    • /
    • 제9권4호
    • /
    • pp.404-408
    • /
    • 1999
  • Effects of heating time and radiation under high temperature on the properties of thermal, mechanical and shielding ability of modified (KNS-101), hydrogenated bisphenol-A(KNS-201) type epoxy resin and phenol-novolac(KNS-301) type epoxy resin based neutron shielding materials that are used for shipping casks for radioactive material have been investigated. At early stages, the offset temperatures of KNS-101, KNS-201 and KNS-301 increased with the heating time under high temperature, but it was rarely affected by the heating time in the later stages. In addition, the thermal conductivities of KNS-101 and KNS-201 decreased with heating time, but that of KNS-301 increased with the heating time. On the contrary, the thermal expansion coefficients of neutron shielding materials decreased with heating time. At the high temperature, the tensile strength and flexural strength of the shielding materials decreased with heating time. On the contrary, the thermal expansion coefficients of neutron shielding materials decreased with heating time. At the high temperature, the tensile strength and flexural strength of the shielding materials of KNS-101 and KNS-301 increased with heating time, but those of KNS-201 decreased with heating time. The shielding ability of neutron shielding materials slightly increased with the radiation dose, and shielding abilities of shielding materials of KNS-101 and KNS-201 were affected to a more extent than that of KNS-301 by radiation dose under high temperature.

  • PDF

마이크로파 및 기존 가열 방법에 의한 제올라이트 NaY의 합성 (Synthesis of NaY Zeolites by Microwave and Conventional Heating)

  • 최고열
    • 공업화학
    • /
    • 제18권4호
    • /
    • pp.344-349
    • /
    • 2007
  • 마이크로파 가열(microwave heating)에 의하여 제올라이트 NaY를 합성하였으며, 그 결과를 기존의 가열 방법(conventional heating)에 의하여 합성한 결과와 비교하였다. 같은 승온 속도를 사용하였을 때는 마이크로파에 의하여 가열하였을 때가 기존의 가열 방법에 비하여 NaY 결정 생성의 유도 기간(induction period)이 감소하였으며 결정의 생성 속도가 증가하였다. 또한 마이크로파의 사용 여부와 관계없이 승온 속도가 빠를 때도 유도 기간이 감소하고 결정 생성 속도가 증가하였다. 빠른 승온 속도에서 합성하였을 때 최종 결정의 크기가 크며, 이는 마이크로파의 사용에 의하여 더욱 증가하였다. 빠른 승온 속도에서는 반응 시간이 짧아져서 NaY의 합성에 소모되는 에너지 소모량은 감소하였다. 본 연구의 조건에서는 에틸렌글리 콜조(ethylene glycol bath)를 사용한 기존 가열 방법에서의 에너지 소모량이 마이크로파 가열보다 적게 나타났는데, 이는 마이크로파 에너지를 사용하는 것이 항상 효율적인 것만은 아니라는 것을 말해준다. 그러나 승온 속도를 적절히 조절하면 마이크로파 가열에 의해서 에너지 면에서 보다 효율적으로 NaY를 합성할 수 있다는 것을 알 수 있었다

마이크로터빈이 포함된 빌딩마이크로그리드시스템의 병원건물의 에너지성능평가 (Energy Performance Evaluation of Building Micro-grid System Including Micro-turbine in Hospital Buildings)

  • 김병수;홍원표
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 추계학술대회 논문집
    • /
    • pp.279-283
    • /
    • 2009
  • Distributed generation(DG) of combined cooling, heat. and power(CCHP)has been gaining momentum in recent year as efficient, secure alternative for meeting increasing energy demands. This paper presents the energy performance of microturbine CCHP system equipped with an absorption chiller by modelling it in hospital building. The orders of study were as following. 1)The list and schedule of energy consumption equipment in hospital were examined such as heating and cooling machine, light etc. 2) Annual report of energy usage and monitoring data were examined as heating, cooling, DHW, lighting, etc. 3) The weather data in 2007 was used for simulation and was arranged by meteorological office data in Daejeon. 4) Reference simulation model was built by comparison of real energy consumption and simulation result by TRNSYS and ESP-r. The energy consumption pattern of building were analyzed by simulation model and energy reduction rate were calculated over the cogeneration. As a result of this study, power generation efficiency of turbine was about 30% after installing micro gas turbine and lighting energy as well as total electricity consumption can be reduced by 40%. If electricity energy and waste heat in turbine are used, 56% of heating energy and 67% of cooling energy can be reduced respectively, and total system efficiency can be increased up to 70%.

  • PDF

지역난방 수용가측 효율관리를 위한 IoT 기반 시스템 구축에 관한 연구 (A Study on the Construction of IoT based System for District Heating Customer-side Energy Efficiency Management)

  • 윤정미;이상학;안창구;엄재식
    • 에너지공학
    • /
    • 제26권3호
    • /
    • pp.113-122
    • /
    • 2017
  • 우리나라 집단에너지 사업의 주요축인 지역난방 시스템은 경제성 있는 열에너지 공급시스템으로 국민편익과 안전에 많은 기여를 해 왔다. 하지만 관리주체의 불명확함, 전문기술인력 부족 등으로 인해 공동주택 수용가측의 열효율저하, 요금 불공정등의 문제가 발생하고 있다. 본 논문에서는 관리사각지대인 지역난방 수용가측 설비의 효율 및 고장관리를 위해 필요한 모니터링 포인트를 제안하고, 이를 표준화 하기 위한 표준참조모델을 제안한다. 또한 IoT 센서 기술을 적용하여 실시간 모니터링 및 통합관리 시스템을 구축함으로써, 지역난방 수용가시설에 대한 서비스 질 개선과 에너지 효율향상을 위한 기술적 방법론을 제안한다.

지역난방 아파트에 대한 난방에너지 실측 및 시뮬레이션 (Measurement and Simulation of Heating Energy for Apartments with District Heating)

  • 이은주;이두영;홍희기;김영균
    • 설비공학논문집
    • /
    • 제26권12호
    • /
    • pp.572-578
    • /
    • 2014
  • Heating energy was measured in an apartment housing unit with a district heating system, varying the kind of hot water distributors. Ondol coils passing through a living room raised the temperature of the room where the heating was turned off. Including this characteristic of Ondol heating into the modeling, we performed simulations and showed a verification by comparison with the results of measurements. As a result, a main flow control method, which changes hot water flow rate supplied to a housing unit according to the thermal load, can reduce the supplied flow rate and lower the return temperature, compared with a constant flow method. That can result in decreased heat loss in utility-pipe conduits even though the heating energy supplied is almost the same. An outdoor reset control that raises the temperature of the supplied hot water if the outdoor temperature falls has the effect of a quicker response in heating than the reduced flow rate and return temperature.

부산시 임대아파트 및 분양아파트의 냉난방에너지 소비량 분석 (Analysis of Heating and Cooling Energy Consumption in Rental and Sales Apartments in Busan)

  • 이경희;이준기
    • 토지주택연구
    • /
    • 제12권3호
    • /
    • pp.79-85
    • /
    • 2021
  • 본 연구에서는 에너지 사용량의 차이를 알아보기 위해 부산시에서 준공된 임대 및 분양아파트의 에너지 사용량을 특정기간동안 분석하였다. 그 결과, 전기 사용량 중 냉방에 소비되는 에너지는 임대아파트는 2.5kWh/m2·yr, 분양아파트는 2.3kWh/m2·yr으로 약 0.2kWh/m2·yr의 차이가 있는 것으로 검토되었다. 전기 사용량 중 난방에 소비되는 평균 에너지는 임대아파트가 3.3kWh/m2·yr, 분양아파트가 2.2kWh/m2·yr으로 약 1.1kWh/m2·yr의 차이를 보였다. 전기장판, 히터 등 전기에너지를 사용하는 임대아파트의 난방 에너지량은 분양아파트보다 많은 것으로 추정된다. 또한, 가스에너지 사용량 중 난방 에너지 사용량은 임대아파트는 7.0kWh/m2·yr, 분양아파트는 6.8kWh/m2·yr로 가스를 이용한 난방에 사용하는 에너지 사용량이 임대아파트보다 적은 것으로 나타났다. 난방에 사용되는 전기 및 가스에너지를 합산하면 분양아파트는 난방에 사용하는 에너지는 9.0kWh/m2·yr, 임대아파트는 10.3kWh/m2·yr으로 추정된다. 난방기간동안 임대아파트는 분양아파트보다 1.3kWh/m2·yr 더 많은 에너지를 사용하는 것으로 확인되었다.