• Title/Summary/Keyword: heating cost saving

Search Result 88, Processing Time 0.023 seconds

Thermo-economic approach for absorption air condition onboard high-speed crafts

  • Seddiek, Ibrahim S.;Mosleh, Mosaad;Banawan, Adel A.
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.4 no.4
    • /
    • pp.460-476
    • /
    • 2012
  • High-speed crafts suffer from losing a huge amount of their machinery energy in the form of heat loss with the exhaust gases. This will surely increase the annual operating cost of this type of ships and an adverse effect on the environment. This paper introduces a suggestion that may contribute to overcoming such problems. It presents the possibility of reusing the energy lost by the ships' exhaust gases as heating source for an absorption air condition unit onboard high-speed crafts. As a numerical example; the proposed method was investigated at a high-speed craft operating in Red Sea between Egypt and the Kingdom of Saudi Arabia. The results obtained are very satisfactory. It showed the possibility of providing the required ship's air condition cooling load during sailing and in port. Economically, this will reduce the annual ship's operating cost. Moreover, it will achieve a valuable reduction of ship's emissions.

Effects of Temperature, Photoperiod and Light Intensity on Growth and Flowering in Eustoma grandiflorum

  • Oh, Wook
    • Horticultural Science & Technology
    • /
    • v.33 no.3
    • /
    • pp.349-355
    • /
    • 2015
  • Lisianthus (Eustoma grandiflorum) is relatively sensitive to temperature and light conditions. For year round production of good quality potted plants and energy saving, it is necessary to understand the growth and flowering response to the combined conditions of these environmental factors. This study was conducted to examine the growth and flowering responses to temperature, photoperiod, and light intensity during the post-seedling stage. 'El Paso Deep Blue' lisianthus plants with four true leaf pairs were grown in growth chambers maintained at average daily temperatures (ADT) of 14, 20, and $26^{\circ}C$ and provided with three photosynthetic photon fluxes [PPF; 100, 200, and $400{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$] for 8 (08:00-16:00) and 16 hours (08:00-24:00) by fluorescent and incandescent lamps, resulting in four daily light integrals (DLI): about 3, 6 (two photoperiods), 12 (two photoperiods), and $24mol{\cdot}m^{-2}{\cdot}d^{-1}$. After treatment for three weeks followed by growth for one week in a greenhouse of $20{\pm}3^{\circ}C$, growth and development were measured. Higher temperature, higher PPF, and longer photoperiod promoted plant growth and flowering; however the impacts of PPF and photoperiod were smaller than those of temperature. As ADT and DLI increased, the number of leaves, number of flowers, lateral shoot length, and shoot dry weight increased. An increase of about $1mol{\cdot}m^{-2}{\cdot}d^{-1}$ DLI could constitute an increase of 0.40 to $0.76^{\circ}C$ ADT depending on these crop characteristics when ADT and DLI are above $20^{\circ}C$ and $12mol{\cdot}m^{-2}{\cdot}d^{-1}$, respectively. Therefore, growers can select a regimen of heating or supplemental lighting without delaying harvesting time or decreasing crop quality.

An Analysis on Thermal Performance and Economic of Heat Recovery Ventilation System Integrated with Window (창호통합형 배열회수 환기시스템의 열성능 및 경제성 평가)

  • Sung, Uk-Joo;Cho, Soo;Song, Kyoo-Dong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.8
    • /
    • pp.646-655
    • /
    • 2012
  • This study is intended to analyze the thermal performance and evaluate the applicability about non-duct type heat recovery ventilation system integrated with window. Eventually, economic analysis of the system is conducted according to building energy saving ratio of it. As results of the thermal performance, the U-factor of the window conducted on the basis of KS F 2278 appears to $1.8W/m^2K$, and the effective heat exchange efficiency of the ventilator conducted on the basis of KS B 6879 appears 49.95% for cooling, 66.89% for heating. In the applicability evaluated by TRNSYS 16, the caes of applying the heat recovery ventilator integrated with window is found to reduce the cooling or heating load by 2.9% or 13.5% than the non-ventilator case. The results of economic analysis taking a side of consumer is verified as the payback is 3 years, and the accumulated earning is 1,408,133 won in terms of '600,000 won/unit' for initial cost, 10 years for useful life of the system.

Analysis of Office Building HVAC System Drawings (사무용 건축물 공조설비 설계도서 분석)

  • Park, Jong-Il;Kim, Se-Hwan;Kim, Dong-Kyu
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.11
    • /
    • pp.776-781
    • /
    • 2007
  • Optimized capacity of equipments are essential for energy saving and low cost construction and operation. So we must use proper design data for HVAC system design. We investigated for architectural data, equipment capacity, cooling and heating load design criteria of 52 office buildings. Following research results were obtained by carrying out each task. Office building effective area rate is 63%. The average building cooling load of South Korea is $140W/m^2$ and average heating loads in Seoul and Pusan area are $120{\sim}130W/m^2$ and $70{\sim}80W/m^2$. We also analysised HVAC design criteria. Person ratio in effective building area is $0.2person/m^2$, sensitive and latent heat loads of a person are 60W and 65W, light and equipment loads of office buildings are $25W/m^2$ and $20W/m^2$.

A Study on the Sri Autobindo Center Guest House Design (Sri Autobindo Center Guest House 디자인에 관한 연구)

  • 손철수
    • Journal of the Korean housing association
    • /
    • v.12 no.4
    • /
    • pp.227-230
    • /
    • 2001
  • The Sri Autobindo Learning Center(SALC) is sponsoring the development of a passive solar village in Creston, Colorado, Situated near the Sangre de Cristo mountains, Savitri Village will be one of several religious communities in the area. This village will incorporate 12 permanent residences and teaching and guest facilities for fifty to one hundred people. The purpose of this study is to evaluate the passive solar elements and performance of guest house at the Sri Autobindo Learning Center(SALC). To do this evaluation, the following tasks needed to be addressed. 1. the guest house design 2. the location of weather data 3. The determination of the building heating load As part of the evaluation process, guest house design will be modified and the building load and solar saving recalculated. This process will be completed until the building performance is deemed satisfactory. The conclusion is as follows; The high solar savings fraction predicted by SUNCODE should taken as an indication that further design changes would probably not be cost effective. But adding removal overhangs or other low costs measures to increase comfort in the summer appear to be appropriate.

  • PDF

A Study on the Energy Performance Renovation for the Sustainable the Residential Houses (친환경주거단지를 위한 에너지 성능개선에 관한 연구)

  • Park, Jin-Chul;Kim, Ki-Hoon;Song, Gook-Sup;Lee, Hyun-Woo
    • Journal of the Korean Solar Energy Society
    • /
    • v.23 no.4
    • /
    • pp.89-96
    • /
    • 2003
  • In planning a building retrofit, energy conservation, thermal comfort and economic benefits should be considered. In this study, retrofit effects of exterior insulating method on preventing condensation, saving energy were analyzed through the heat transfer simulation, energy simulation in the apartment house retrofitted by exterior insulating method cheaper than other retrofit methods. The results of this study show that the retrofit using exterior insulating method can prevent the condensation at the corner walls and save about 20% of annual heating load. The LCC analysis revealed to be effective to select a dryvit system for a building retrofit.

Optimization of Heat Exchanger Network in the Steam Assisted Gravity Drainage Process Integration

  • Rho, Seon-Gyun;Yuhang, Zhang;Hwang, InJu;Kang, Choon-Hyoung
    • International Journal of Advanced Culture Technology
    • /
    • v.8 no.2
    • /
    • pp.260-269
    • /
    • 2020
  • The Steam Assisted Gravity Drainage (SAGD) process is an enhanced method to extract oil from bitumen which involves surface and central process facilities. This paper describes the Central Process Facilities (CPF) of SAGD and proposes several retrofit plans to the Heat Exchanger Network (HEN). In this approach, the process integration scheme is applied to estimate the energy saving in HENs, and various cases are modeled in favor of a commercial simulator. Throughout this work, a minimum approach temperature of 10℃ is assumed. The results reveal that, due to the HEN optimization using process integration, the heating and cooling duties can be reduced to 29.68MW and 1.886MW, respectively. Compared with the Husky case, all cases considered in this study indicate a potential reduction of at least 6% in total cost, including investment and operation costs.

Experimental Study on the Flexural Capacity of AU Composite Beam After the Heating Test (가열 시험을 거친 AU 합성보의 휨 성능에 관한 실험 연구)

  • Kim, Young Ho
    • Journal of Korean Association for Spatial Structures
    • /
    • v.19 no.3
    • /
    • pp.77-83
    • /
    • 2019
  • AU(A plus U-shaped) composite beam was developed for reducing the story height in the residential buildings, and saving the cosrtuction cost of floor structures. Structural performance and economic feasibility of the composite beam have been sufficiently approved through the structural experiments and the analytical studies. Fire safety for the practical application of the composite beam has also been verified through the fire resistance tests and the heat transfer analyses. In this study 2-points bending tests were performed on the four specimens already tested for fire resistance to evaluate the residual bending strength of AU composite beam after fire accident. The same bending test was performed on the one fresh specimen having the same section and span of the specimens for practically comparative study.

Study on construction method of horizontal ground heat pump system using the building structure (건물구조체를 이용한 수평형 지열시스템의 시공법에 관한 연구)

  • Chae, Ho-Byung;Nam, Yujin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.11a
    • /
    • pp.139-140
    • /
    • 2013
  • Ground source heat pump systems can achieve the energy saving of building and reduce CO2 emission by utilizing stable ground temperature. However, they have many barriers such as high cost of installation, incompletion of design tool, lack of recognition as heating and cooling systems. In order to solve the problems, the building integrated geothermal system (BIGS) developed by several researches which use building foundation as a heat exchanger. In order to establish the optimum design tool of BIGS with the horizontal heat exchanger, the prediction method of ground heat exchange rate developed with numerical simulation model. In this study, the economic analysis for BIGS was conducted based on simulation results and the optimal design method was suggested. As a result, it was found that the case of 32 A, piping space 0.3 m, piping deep 0.5 m and flow rate 9.52 L/min was the best case as 50.1 W/m2 of heat exchange rate. In this case the initial cost was reduced to 115 million won.

  • PDF

A Study on the Optimization of District Heating and Cooling Facilities (지역냉난방사업의 설비 최적화에 관한 연구)

  • Kim, Jin Hyung;Choi, Byung Ryeal
    • Environmental and Resource Economics Review
    • /
    • v.15 no.3
    • /
    • pp.505-530
    • /
    • 2006
  • For the district heating and cooling business, it is required to install energy-saving facilities using energy from waste and land fill gases such as combined heat and power(CHP). The current issues that this business faces can be summarized as below: which facilities including CHP can be economically introduced and how much of their capacities should be. Most of such issues are clearly related to the optimal plant design of the district heating and cooling business, and the prices of energy services such as heating and cooling energy, and electricity. The purpose of this study is to establish linear program model of least cost function and to practice the empirical test on a assumed district heating and cooling business area. The model could choose the optimal type of energy-producing facilities among various kinds available such as CHP's, absorption chillers, the ice-storage system, etc. CHP with the flexible heat and power ratio is also in the set of available technologies. And the model show us the optimal ration of heat producing facilities between CHP and historical heat only boiler in the service area. Some implications of this study are summarized as below. Firms may utilize this model as a tool for the analysis of their optimal size of the facilities and operation. Also, the government may refer the results to regulate resonable size of business.

  • PDF