• 제목/요약/키워드: heating cost saving

검색결과 88건 처리시간 0.024초

중앙난방방식을 지역난방.소형열병합난방방식으로 전환시의 경제성 비교 분석 (Analysis for the Economic efficiency of District Heating and Gas Engine Co-generation System comparing with Central Heating System)

  • 김규생;이상혁;홍경표;원영재
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.459-465
    • /
    • 2007
  • This study was conducted to calculate the LCC of a apartment complex with a type of heating system, district heating and cogeneration system. For the purpose of analyzing LCC according to size of apartment complex, 500, 1,500 and 4,000 houses of model apartment selected. This research performs design of heating system and the life cycle cost analysis including an initial cost, energy cost, maintenance and operation cost, replacement cost and renovation cost during the project period(15years). According to the calculated results, 1) Initial cost of cogeneration system with 500, 1500 and 4000 houses is higher than district heating system each of 20%, 13%, 12%. 2) In case of cogeneration system, the payback period by electric generation is 5.21, 4.92 and 4.47 years and saving cost was calculated 29 billion won, 94 billion won and 262 billion won after payback period. 3) Cogeneration system LCC was 1.12, 1.07 and 1.06 times larger than district system with the size of apartment complex. According to the case of this study district heating system is more efficient than cogeneration system in terms of the reduction of LCC. 4) Gas Engine Co-generation System is more efficient than other systems because it can collect progressive part from electric charge progressive stage system. However, the efficiency is decreasing because of raising of fuel bills(LNG) and lowering of power rate for house use. Especially the engine is foreign-made so the cost of maintenance and repair is high and the technical expert is short. 5) District heating is also affected by fuel bills so we should improve energy efficiency through recovering of waste heat(incineration heat, etc.). Also, we should supply district cooling on the pattern of heat using of let the temperature high in winter and low in summer.

  • PDF

춘천시 주거지구내 수목피도의 차이가 난냉방에너지 이용 및 비용에 미치는 효과 (Effects of Difference in Tree Cover on Use and Cost of Heating and Cooling Energy in Residential Neighborhoods of Chuncheon)

  • 조현길;안태원
    • 한국조경학회지
    • /
    • 제27권2호
    • /
    • pp.19-28
    • /
    • 1999
  • This study quantified shading, evapotranspiration and windspeed-reduction effects of trees on use and cost of heating and cooling energy in two residential neighborhoods of Chuncheon different in tree cover. Annual savings per residence of heating energy were approximately 1,210 MJ(1%) and those of cooling energy, 130 kWh(10%) in study district 1 having tree cover of about 10% . For district 2 with tree cover of about 20%, annual heating and cooling savings were 2,130 MJ(2%) and 180 kWh(19%) per residence, respectively. Trees annually saved energy costs by approximately ₩31,000 ($26, $1=₩1,200) per residence in district 1 and by ₩49,000($41) in district 2. One tree taller than 3 m resulted in annual energy savings of ₩8,000($7) in the study districts. Energy savings by trees in district 2, which had higher tree cover by 10% difference than district 1, were about 2 times greater than those in district 1. This implies that more tree plantings could enhance energy saving effects. Of the total costs saved, 58% was attributed to windspeed reduction and 47%, evapotranspiration. However, shading increased energy costs by 5% due to tree plantings at the wrong locations. Full tree plantings on the west and north of buildings and avoidance of shade-tree plantings of use of solar-friendly trees on the south are recommended to increase building energy savings efficiently.

  • PDF

창호 리트로피트를 통한 에너지 절감 및 실내 열환경 개선 효과 분석에 관한 연구 (Energy Saving Effect and Improvement of Indoor Thermal Environment through the Window Retrofit)

  • 정진우;주정훈;조동우
    • 한국태양에너지학회 논문집
    • /
    • 제38권3호
    • /
    • pp.29-36
    • /
    • 2018
  • The goal of this study is to retrofit the windows of residential buildings and to activate the green remodeling by verifying energy saving and indoor thermal environment. As a result of analysis of the energy saving effect of 458 units window retrofits, it was possible to reduce the energy requirement by 48.20% ~ 54.97%. According to the improvement on indoor environment, it was possible to operate by reducing heating temperature and supply time. The actual gas consumption of the heating period was reduced by 25% compared with that of the window retarder to save 28,968 thousand won of heating energy cost. Resident's satisfaction surveys were conducted one year after window retrofit. More than 80% of the respondents answered that they satisfied the improvement on window performance, indoor thermal environment and indoor sound environment. As a result, we verified the energy saving effect and the improvement on the indoor environment through window retrofits.

에너지, 환경 및 경제성을 통합 고려한 공동주택 설계요소 제어에 관한 연구 (A Study on the Control of Apartment House Design Factors considering Energy, Environment and Economical Efficiency)

  • 최두성;도진석
    • KIEAE Journal
    • /
    • 제12권6호
    • /
    • pp.29-38
    • /
    • 2012
  • The current building energy efficiency rating certification regulation on apartment houses evaluates only the saving rate of energy consumed during operation, i.e. use, of a building, but doesn't consider the energy consumptions and environmental load($CO_2$) emissions occurring during the whole lifetime of a building. So this study calculated the energy consumptions and environmental load emissions occurring during the whole lifetime of a building, selected reference schemes and alternative items by design variables to present a design draft considering energy efficiency and environmental performance, and evaluated the total cost by combining and calculating its direct cost(material and heating cost) and indirect cost(environmental cost), for an existing apartment house as an evaluation object. As a result of analysis, the change of heating cost by alternative items of design variables showed a 4~8% change rate compared to the reference scheme, and the material cost of design variable 7 showed a maximum 4.4 times change rate in the alternative plan 6 compared to the reference scheme. The environmental cost showed a similar change rate to the material cost change rate in general, but showed a similar environmental cost change rate to the heating cost change rate in case of design variables 4-1, 4-2, 7.

에너지절약설계기준의 단열 변화에 따른 공동주택 실효성 검토 - 난방 및 급탕에너지 사용금액 분석 - (Review on the Effectiveness of Apartments According to Insulation Reinforcement of Energy Saving Design Standard - Energy Cost Analysis of Space Heating and Domestic Hot Water -)

  • 김지현;임희원;이현승;신우철
    • 대한건축학회논문집:구조계
    • /
    • 제36권1호
    • /
    • pp.173-178
    • /
    • 2020
  • In this study, we analyzed space heating and domestic hot water(DHW) charges from 2017 to 2018 for 151,206 households in 202 apartment complexes built from 1997 to 2016, in order to evaluate the effectiveness of Korea's insulation standards reinforcement. The applied insulation standards were revised three times(in 1987, 2001 and 2010). We used the Anderson-Darling test to review the normality of the space heating and DHW charges. As a result, each p-value was greater than 0.05 and it followed the normal distribution. The annual average space heating charges per unit area of apartments with the 1987 insulation standards were 5,237₩/㎡a in 2017 and 5,328₩/㎡a in 2018. The heating charges with the 2001 standards were 4,827₩/㎡a in 2017 and 4,817₩/㎡a in 2018. Compared to previous standards(1987 standards), heating charges decreased by 7.8% and 9.6%. Also the heating charges with the 2010 standards were 3,683₩/㎡a in 2017 and 3,734₩/㎡a in 2018. Compared to previous standards(2001 standards), heating charges decreased by 24.3% and 21.5%. On the other hand, compared to each previous standards, DHW charges were decreased by 12.2%, 13.6% or increased by 4.6%, 6.9%, which means there's no correlation between insulation standards reinforcement and DHW charges.

중앙난방방식을 지역난방과 소형열병합난방 방식으로 전환 시 경제성 비교 분석 (Analysis of the Economic Efficiency of the District Heating and Gas Engine Co-Generation System Compared with the Central Heating System)

  • 김규생
    • 설비공학논문집
    • /
    • 제27권10호
    • /
    • pp.544-551
    • /
    • 2015
  • This study was conducted to determine the LCC of apartment complexes with district heating and a cogeneration system. For the purpose of analyzing LCC according to the size of the apartment complex, 500, 1,500, and 4,000-unit model apartments were selected. Analysis was performed on the design of the heating system and the life cycle cost including total construction cost, maintenance and operation cost for the duration of the project period (15 years). According to the calculated results, 1) The initial cost of the cogeneration system for 500, 1,500, and 4,000-unit apartments is higher than that of the district heating system by 20%, 13%, and 12%, respectively. 2) In the case of the cogeneration system, the payback period by electric generation was found to be 5.21, 4.92 and 4.47 years, and saving cost was calculated to be 29 billion won, 94 billion won and 262 billion won after the payback period for 500, 1,500, and 4,000-unit apartments, respectively. 3) The LCC values of the cogeneration system were 1.12, 1.07 and 1.06 times larger than those of the district system according to the size of the apartment complex. In this study, the district heating system was found to be more efficient than the cogeneration system in terms of LCC reduction. 4) District heating is affected by fuel bills, so energy efficiency should be improved through recovering waste heat (incineration heat, etc.). Also, district cooling should be provided according to heat use to keep the temperature high in winter and low in summer.

나노탄소섬유 적외선등 난방이 절화장미의 생육과 수명 및 난방비에 미치는 영향 (Effect of Heating by Nano-Carbon Fiber Infrared Lamps on Growth and Vase Life of Cut Roses and Heating Cost)

  • 임미영;고충호;손문숙;이상복;김길주;김병수;김영복;정병룡
    • 생물환경조절학회지
    • /
    • 제18권1호
    • /
    • pp.1-8
    • /
    • 2009
  • 장미 생산농가의 대부분은 겨울철 난방비가 생산비의 가장 큰 몫을 차지한다. 요즘과 같은 고유가 시대에 농가의 부담을 줄이기 위하여 난방비 절감율이 높은 난방시스템에 대한 연구를 수행하였다. 복사열을 이용한 적외선 등 난방의 경우 식물체와 같은 물체를 먼저 가열하여 주변의 기온이 올리는 방식으로 빠르게 온도를 높일 수 있고 경유를 이용한 난방방식에 비해 비용이 절감되는 장점이 있다. 농가에 설치된 나노탄소 섬유 적외선 등 난방시스템의 현지조사를 실시하여 난방효과 및 난방비 절감율을 분석하고, 나노탄소섬유 적외선 등 난방시스템과 전기히터 난방시스템에서 생산된 '오렌지 플레쉬' 장미의 생육과 절화수명을 조사하였다. 나노탄소섬유 적외선 등의 경우 온실 내부 공기 설정온도가 $20^{\circ}C$인 경우 식물체 온도는 $1{\sim}2^{\circ}C$정도 더 높게 나타났을 뿐만 아니라 베드와 근권부 온도는 $17{\sim}19^{\circ}C$ 정도로 유지하는 등 우수한 난방의 효과를 알 수 있었고, 전기히터 난방시스템과 온수보일러 난방시스템의 추정 난방비를 비교한 결과 난방비 절감 효과가 아주 높게 나타났다. 장미의 생육을 조사한 결과 전기히터 난방시스템에서 생육한 장미와 차이가 없었으며 화색이나 염색의 발현이 더 좋았다. 절화수명에서는 나노탄소섬유 적외선 등에서 생육한 장미가 생체중과 수분 흡수량이 높아 다소 더 길어진 절화수명을 뒷받침 해 주었다.

에너지 절약형 전기 온풍기 개발 (Development of Energy Saving Electric Fan Heater)

  • 김진봉;구대현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 A
    • /
    • pp.97-99
    • /
    • 1994
  • Energy saving electric fan heater that uses driving part as heating part is different from general fan heater. As it uses energy that drives rotor and generate heat at the same coil. it is simpler and cheaper than fan heater. In this study, shaded-pole motor that is low cost and simple in spite of low efficiency was used for th fan heater.

  • PDF

빌딩 에너지 관리 최적화 알고리즘 설계 및 구현 (Design and Implementation of Optimal Control Algorithms for Building Energy Management)

  • 진중화;정선태
    • 설비공학논문집
    • /
    • 제16권10호
    • /
    • pp.969-976
    • /
    • 2004
  • Building energy saving is one of the most important issues in these days. Energy saving control strategies should be developed properly to achieve the saving. One of such area we could apply is the HVAC (Heating, Ventilation and Air-Conditioning) system. Through the optimal control algorithm for building energy management system (EMS), you can not only save the cost of building energy, but also protect HVAC system components against the unexpected condition. In order to verify the effectiveness of building energy saving, field test was accomplished for several months at 'A' building. And to get the measured data, remote control was used. If the remote control is used in BAS (Building Automation System), control and monitoring can be done for all of the building systems, such as HVAC, power, lighting, security and fire-alarm etc. anywhere any time. Using the remote control, Control and monitoring is possible for the testing system without going there. As the results of field test, we could reduce $5{\sim}10\%$ of the building energy cost.

일반공조 시스템 대비 축열조와 연동된 수직밀폐형 지열히트펌프의 냉난방 에너지 성능 및 경제성 분석 (Cooling and Heating Energy Performance and Cost Analysis of Vertical Closed-loop Geothermal Heat Pump Coupled with Heat Storage Tank Compared to Conventional HVAC System)

  • 김민지;도성록;최종민;이광호
    • 대한건축학회논문집:구조계
    • /
    • 제34권11호
    • /
    • pp.81-87
    • /
    • 2018
  • Among various types of geothermal heat pump systems, Vertical Closed-Loop Geothermal Heat Pump (VGSHP) has received increasing attention due to a variety of advantages such as the potential to be installed in a relatively small space and improved energy efficiency. In this research, the performance of VGSHP system coupled with heat storage tank was evaluated, by analyzing operational behavior of heat storage tank, the variations of heat pump energy performance due to the connection with heat storage tank, part load ratios characteristics of heat pump and the corresponding energy cost, compared to chiller and boiler based conventional system. The results of this study showed that the VGSHP system coupled with heat storage tank showed an energy saving effect of about 18% for cooling and about 73% for heating, and annual heating/cooling energy cost reduction of 43,000,000 KRW ($ 39,000), compared to the conventional air conditioning system. In addition, after considering both energy cost and initial investment cost including equipment, installation and auxiliary device expenses, payback period of approximately 11.8 years was required.