• 제목/요약/키워드: heating condition

검색결과 1,304건 처리시간 0.032초

태양열 시설원예 난방시스템의 장기성능 특성 분석 연구 (Study on long-term Performance characteristics of various solar thermal system for heating protected horticulture system)

  • 이상남;강용혁
    • 한국태양에너지학회 논문집
    • /
    • 제26권3호
    • /
    • pp.1-8
    • /
    • 2006
  • The objective of this research is to study on the analysis of long-term performance characteristics of various solar thermal system for heating protected horticulture system for reducing heating cost, increasing the value of product by environment control, and developing advanced culture technology by deploying solar thermal system. Long term field test for the demonstration was carried out in horticulture complex in Jeju Island. Reliability and economic aspect of the system which was operated complementary with thermal storage and solar hot water generation were analyzed by investigating collector efficiency, operation performance, and control features. Optimum operating condition and its characteristics were closely investigated by changing the control condition based on the temperature difference which is the most important operating parameter. However, it is expected that, in high-insolation areas where large-scale ground storage is adaptable, solar system demonstrated in the research could be economically competitive and promisingly disseminate over various application areas.

테이프가 있는 거친 사각채널에서 가열벽면의 수가 열전달에 미치는 효과 (Effects of Number of Heating Walls on Heat Transfer in the Rough Square Channel with Twisted Tape)

  • 안수환;김명호;배성택;강호근
    • 동력기계공학회지
    • /
    • 제10권3호
    • /
    • pp.17-22
    • /
    • 2006
  • Surface modifications like rib-roughening and displaced insert devices like the twisted tape are commonly used in applications such as compact heat exchangers and cooling systems. In this paper, regionally averaged heat transfer distributions in square channels with twisted tape inserts and with twisted tape inserts plus interrupted ribs are respectively investigated. The square ribs are arranged to follow the trace of the twisted tape and along the flow direction defined as axial interrupted ribs. Each wall of the square channel is composed of isolated aluminum sections. Regionally averaged Nusselt number and channel averaged Nusselt number in turbulent air flows are presented for Reynold numbers from 8,900 to 29,000. We have obtained the following conclusions from the experimental study: 1) The local Nusselt number in the two-sided heated case is higher than that in the four-sided heated condition. 2) In the 4 heating wall channel with twisted tape inserts, Nusselt number based on bottom wall temperature is enhanced by 1.2 - 1.6 times if adding the axial interrupted ribs on the bottom wall only. 3) The twisted tape with interrupted ribs under the two-sided heating condition produces the highest heat transfer coefficient.

  • PDF

도재용착주조관용 비귀금속 합금의 사전 열처리가 도재-금속의 결합 강도에 미치는 효과 (The effect of oxidation heat treatment on porcelain to metal bond strength)

  • 김치영;남상용
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 춘계학술대회
    • /
    • pp.43-46
    • /
    • 1997
  • The interfacial bond strength and microstructural analysis of pre-heat treated porcelain-fused-metal (PFM) were investigated using a mechanical three-point bending tester and scanning electron microscope(SEM). Four kinds of heat treated samples were prepared as follows; A: heating $1200^{\circ}F\rightarrow1600^{\circ}F$, holding 1min, reheating $\rightarrow1850^{\circ}F$, hold 3min under vacuum, B: heating $1200^{\circ}F\rightarrow1600^{\circ}F$ holding 1min, reheating $\rightarrow1850^{\circ}F$ under vacuum condition, C: heating $1200^{\circ}F\rightarrow1600^{\circ}F$, holding 1min, reheating $\rightarrow1850^{\circ}F$, holding 3min in the air, repeat same heat treatment process under vacuum condition, D: heating $1200^{\circ}F\rightarrow1600^{\circ}F$, holding 1min, reheating $\rightarrow1850^{\circ}F$, holding 1min in the air. The three-point bending test results shows that the interfacial bond strength of specimen B and C were higher than that of A and B. The SEM study reveals that Specimen C shows the highest surface density.

  • PDF

Cold crucible을 이용한 실리콘의 전자기주조 (Cold Crucible Electromagnetic Casting of Silicon)

  • 신제식;이상목;문병문
    • 한국주조공학회지
    • /
    • 제25권3호
    • /
    • pp.115-122
    • /
    • 2005
  • In the present study, an EMC (Electromagnetic Casting) process, using a segmented Cu cold crucible under a high frequency alternating magnetic field of 20 kHz, was practiced for the fabrication of poly-crystalline Si ingot of 50 mm diameter. The effects of Joule heating and electromagnetic pressure in molten Si were systematically investigated with various processing parameters such as electric current and crucible configuration. A preliminary experimental work was initiated with the pure Al system for the establishment of a stabilized non-contact working condition, and further adapted to the semiconductor-off-grade Si system. A commercialized software such as Opera-3D was utilized in order to simulate electromagnetic pressure and Joule heating. In order to evaluate the meniscus shape of the molten melts, shape parameter was used throughout the research. A segmented graphite crucible, which was attached at the upper part of the cold crucible, was introduced to enhance significantly the heating efficiency of Si melt keeping non-contact condition during continuous melting and casting processes.

태양열 시스템의 제어조건에 따른 난방 및 급탕 실증연구 (Demonstration study on Heating and Hot water According to Control Condition of Solar System)

  • 주홍진;곽희열;김정배;김종보
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.832-837
    • /
    • 2006
  • This study describes thermal performance of heating and cooling demonstration system using ETSC(Evacuated tubular solar collector) installed at Seo-gu art center of Kwangju. For demonstration study, a reading room with about $331m^2$ was heated and cooled using that system. The demonstration system was consisted of ETSCs, storage tank, hot water supply tank, subsidiary boiler, and subsidiary tank. From January to March in 2006, demonstration test were performed with 4 control mode to find the optimum control condition for solar thermal system. After experiments and analysis, this study found that solar thermal system of control mode IV was corresponded to 78% for the hot water supply and 49% for space heating.

  • PDF

HFC32 냉매를 사용한 지열원 히트펌프의 성능 특성 (Performance of the Geothermal Heat Pump Using HFC32 Refrigerant)

  • 박용정;박병덕
    • 한국수소및신에너지학회논문집
    • /
    • 제30권4호
    • /
    • pp.369-375
    • /
    • 2019
  • Air conditioners adopting high energy efficiency and low global warming potential (GWP) refrigerant are being developed globally. In case of commercial air conditioner, R32 with lower GWP than R410A is attracting industrial attentions. In this study, the performance of water-to-water geothermal heat pump adopting R32 is compared with that of the heat pump using R410A. By using R32 instead of R410A, heating capacity and COP in heating standard condition can be increased by 8.8% and 6.3% respectively. Also, cooling capacity and COP in cooling standard condition can be increased by 5.3% and 3.1% respectively by using R32. But in case of using R32, systemic improvements are required to decrease discharge temperature of compressor since discharge temperature rises abnormally in heating operations.

촉매연소를 이용한 동 열처리용 환원로에 관한 연구 (A Study on Reductive Furnace for Copper Annealing Using Catalytic Combustion)

  • 정남조;강성규;송광섭;조성준;유상필;유인수
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2001년도 제23회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.83-89
    • /
    • 2001
  • Most technologies of reduction process used in the heat treatment of existent metal products are related to metals applied to bolts and parts of automobiles, and nonmetal such as copper. Heating conditions and reduction gases produced in above processes depend on types of products to be treated thermally but heating systems employ electricity commonly and the reduction gases are separated into additional production equipment and a gas dryer and inefficiently provided into the system. Electrical heating system has the advantage of convenient temperature-control but is not economical because of disadvantages of high electricity-running cost and extra installation cost of a transformer. Accordingly, development of the system which has economical heating mode in which provision of reduction gas and heating conditions are unified is necessary for improvement of economy and efficiency in current reduction processes. This study aimed to develop a new advanced heat treatment furnace using catalytic combustion. thereby minimizing the cost during heating, supplying heat and reductive gas at the same time and controlling operating condition freely by changing electrical heating system to heating system by the gas combustion and regeneration of wasted heat.

  • PDF

유연한 섬유상 발열체용 카본블랙 복합소재의 전기적 특성 (Electrical Properties of Carbon Black Composites for Flexible Fiber Heating Element)

  • 박지용;이종대
    • 한국응용과학기술학회지
    • /
    • 제32권3호
    • /
    • pp.405-411
    • /
    • 2015
  • Carbon composites for flexible fiber heating element were examined to improve the electrical conductivity in this study. Carbon composites using carbon black, denka black, super-c, super-p with/without CNF or dispersant such as BCS03 and Sikament-nn were prepared. Carbon composite slurry was coated on plane film and yarns(cotton, polyester) and the performances of prepared heating materials were investigated by checking electrical surface resistance, adhesion strength. The plane heating element using carbon black under natural drying condition($25^{\circ}C$) had better physical properties such as surface resistance(185.3 Ohm/sq) and adhesion strength(above 90%) than those of other carbon composite heating elements. From these results, polyester heating element coated by carbon black showed better electrical line resistance(33.2 kOhm/cm) than cotton heating element. Then, it was found that polyester heating element coated by carbon black with CNF(3 wt%) and BCS03(1 wt%) appeared best properties(0.604 kOhm/cm).

실제적 구조를 가진 벌크 및 SOI FinFET에서 발생하는 동적 self-heating 효과 (Dynamic Self-Heating Effects of Bulk and SOI FinFET with Realistic Device Structure)

  • 유희상;정하연;양지운
    • 전자공학회논문지
    • /
    • 제52권10호
    • /
    • pp.64-69
    • /
    • 2015
  • 본 연구에서는 실제적 구조를 가지는 bulk와 SOI FinFET에서의 self-heating 효과를 3차원 TCAD 전산모사를 통하여 분석하였다. 기존 연구들에서와 마찬가지로 self-heating 효과에 의해 나타나는 정적인 구동전류의 감소는 SOI FinFET에서 bulk FinFET보다 더 심각함을 보여주고 있다.. 그러나 고속의 logic 동작 및 실제적 구조를 감안하면 SOI FinFET에서의 동적 self-heating 효과는 bulk FinFET과 큰 차이가 없음을 강조한다.

350 kW(300,000 kcal/h)급 우드 펠렛 보일러 운전 특성 및 성능 평가 (Performance Test and Flue Gas Characteristics of a 350 kW Wood Pellet Boiler)

  • 김종진;강새별
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.167-171
    • /
    • 2009
  • We conducted performance test of a 350 kW class wood pellet boiler installed at a dormitory whose total area is $1,354\;m^2$. The maximum heating capacity of the boiler is 350 kW(300,000 kcal/kg). The wood pellet boiler consists of 3 parts; boiler, hot water storage tank and wood pellet storage tank. In testing the boiler, we shut off hot water utility supply and open up floor heating water system in order to measure exact value of the heating output of the wood pellet boiler. To determine the efficiency and heating output of the wood pellet boiler, we measured mass flow rate of wood pellet, the lower heating value(LHV) of the wood pellet, mass flow rate and temperature of water for floor heating and so on. We measured the mass flow rate of fuel, wood pellet with respect to rotational speed of auger, wood pellet feeding screw. We also measured the flue gas concentration of the wood pellet boiler by using a gas analyser. The result shows that the efficiency of the wood pellet boiler is 80.6% based on lower heating value at 124 kW of heating output. At this condition, O2 concentration of the flue gas is 6.0%, CO and NOx concentrations are 85 and 102 ppm.

  • PDF