• Title/Summary/Keyword: heating capacity

Search Result 677, Processing Time 0.029 seconds

Feasibility Study for Applying Desiccant to Low Temperature Vacuum Drying Process (저온진공건조 공정에 제습제 적용을 위한 타당성 연구)

  • Sim, Yeonho;Kang, Jisu;Byun, Siye;Chang, Young Soo;Kang, Byung Ha
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.5
    • /
    • pp.208-215
    • /
    • 2016
  • This study was conducted to improve the performance of low-temperature vacuum dryer by applying desiccant to cold trap. Performance evaluation was carried out using several desiccants. The amounts of absorption and diffusivity were measured based on analytic model. Results of desiccant performance evaluation revealed that silica-gel had the most excellent performance for conditions of low-temperature vacuum drying process. Silica-gel was applied to cold trap for evaluating the drying performance. The experiment results showed that the drying time was extended as the thickness of sample was increased due to increased heat and mass transfer resistance of drying sample. In addition, as heating plate temperature was increased, drying time was decreased due to increased evaporation pressure of drying sample. Furthermore, drying time with desiccant was decreased approximately 20% than that without desiccant.

Effects of Phosphate Complex the Functional Properties of Fish Meat and Animal Meat of Mixture Pastes -Effect of Properties on the Quality Stability and Technical- (인산성 첨가에 따른 혼합 연육제품에 관한 연구 -품질 및 기능적 성질에 미치는 영향-)

  • 홍종만
    • The Korean Journal of Food And Nutrition
    • /
    • v.3 no.1
    • /
    • pp.39-56
    • /
    • 1990
  • The effects of six kinds of phosphate complex on the water holding capacity (W.H.C) and protein solubility of hair tail, yellow tail runner and dried pollack meat paste were investigated and animal meat(pork, chicken and hare meat complex) The formulation of six kind of phosphate complex employed to this experiment were made by mixing several phosphate such as sodium polyphosphate, sodium pyrophosphate, sodium acid pyrophosphate, potassim pyrophosphate, sodium ultra-meta-phosphate, sodium-tetra-phosphate and monoglyceride at different mixture ratio Among the six kinds of phosphate complex, phosphate B complex which was formulated by mixing sodium polyphosphate 40%, sodium pyrophosphate 30%, sodium tetra mata phosphate 10%, sodium ultra meta phosphate 10% was most effective on enchanging the W H. C, and protein solubility of hair tail, yellow tail runner dried pollack meat past and in case of pork, chicken and hare meat paste. Phosphate C complex which was formulated by mixing sodium polyphosphate 50%. sodium pyrophosphate 30%, sodium tetra meta phosphate 10%, potassium pyrophosphate 10%, was more effective them other phosphate complex, and thief optimum addition level was 0.5% respectively in weight of fish meat paste. Texture characteristics such as hardness, cohesiveness and springiness value of Kamaboko(fish meat and pork, chicken, hare meat complex past meat product) were evaluted as best when 0.5% of Phosphate B complex was added The optimum cooking condition of Kamaboko to get good texture was heating for 20 minutes at 12$0^{\circ}C$.

  • PDF

Survey Study of Optimal Cooling Equipment Capacity of the Large Hospitals in Busan City (부산지역 대형병원 냉방장비의 용량설정 실태조사)

  • Lee, Ji-Weon;Chin, Kyung-Il;Kim, Se-Hwan
    • KIEAE Journal
    • /
    • v.14 no.6
    • /
    • pp.105-110
    • /
    • 2014
  • The basic factors determining the amount of energy used in hospital buildings are weather conditions and building factors. But the real energy consumer is central plant equipment such as boilers and chillers that produce thermal energy for heating and cooling. Inaccurate decision of the primary equipment's size can cause a high initial-cost, an excessive equipment space, a wasted energy by low operation-efficiency and shortening of the machine's life. In this reason, the decision of optimal size for central plant equipment is very important. There are several factors for the decision such as an operation factor, a factor (equipment factor), piping losses and a simultaneous usage factor applied in the sizing process except a basic cooling load. But there is no standard method for applying those factors. Usually, factors are applied individually by an experience or custom of each engineer. In this study, the authors emphasize the meaning and the problem of those factors, examine them by analyzing factors which were applied to actual practices, and propose the recommendation value of safety, load, operation factors and application methods.

A Study on the Operating Characteristics of Commercial Frequency Plasma Jet Torch (상용 주파수 (60Hz) Plasma Jet Torch의 동작특성에 관한 연구)

  • 전춘생;정재웅
    • 전기의세계
    • /
    • v.24 no.1
    • /
    • pp.75-85
    • /
    • 1975
  • In order to develop the commercial frequency (60Hz) plasma torch of small capacity for material cutting, welding and other industrial heating, the A.C plasma jet generator of non-transfered type is made domestically and the electrode configurations of plasma torch are composed of two kinds of electrodes W-C and W-Cu, combined by thermal emission and field emission electrode materials. In this paper, the characteristics of input power, thermal efficiency, electrode consumption, the flame and forms of arc voltage and arc current for A.C plasma torch are investigated in relation to such variables as arc current, argon flow and magnetic field intensity to obtain the basic design data necessary to A.C plasma jet generator. The result are as follows; (1)The input power, thermal efficiency and electrode consumption are influenced greatly by argon flow, magnetic field intensity and nozzle materials. (2)A.C arc voltage and current are non-symmetrial, involving D.C Component. Due to this current of D.C Component, transformer core is saturated and a large abnormal current flows into the primary winding coil. In order to prevent this abnormal current flow, a condenser must be connected in series to the main discharge circuit. (3)The stability and sharpness of jet flame are improved more in the torch of W-C electrode configuration than in the torch of W-Cu electrode configuration.

  • PDF

The correlation of the eletrochemical properties for $Li[Li_yMn_{2-y}]O_4$ cathode materials ($Li[Li_yMn_{2-y}]O_4$ 정극 활물질에 대한 전기화학적 특성의 상호관계)

  • Jeong, In-Seong;Kim, Min-Sung;Gu, Hal-Bon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.05b
    • /
    • pp.269-272
    • /
    • 2000
  • Spinel $LiMn_2O_4$ samples are prepared by heating a $LiOH{\cdot}H_2O/MnO_2$ mixture in air at $800^{\circ}C$ for 36h, and their structure and electrochemical performance are studied by using X-ray diffraction, Cyclic Voltammetry, AC Impedance, and Charge-discharge measurements. It was found that the electrochemical properties of the $LiMn_2O_4$ samples are very sensitive to substituted volume of lithium. Initial impedances of all cathode was similar. Initial resistance was $60{\sim}70{\Omega}$. Reaction peak of Cyclic voltammetry was weak by increase of substituted volume of lithium. $Li[Li_{0.08}Mn_{1.92}]O_4$ and $Li[Li_{0.1}Mn_{1.9}]O_4$ cathode materials showed the charge and discharge capacity of about 125mAh/g at first cycle, and about 95mAh/g after 70th cycle. It showed excellent property in sample revealed good structure and other electrochemical property.

  • PDF

Performance Variations of River Water Source Heat Pump System According to Heat Exchanger Capacity Variations (열교환기 용량변화에 따른 하천수열원 열펌프의 성능 변화)

  • Park, Seong-Ryong;Baik, Young-Jin;Kim, Hee-Hwan;Lee, Young-Soo
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1530-1535
    • /
    • 2003
  • The utilization of unused energy is important because it can afford to offer a chance to increase energy efficiency of a heat pump system. One of the promising unused energy sources is river water. It can be used as a heat source in both heating and cooling effectively with its superior features as a secondary working fluids. In this study, the performance of a 5HP heat pump system using river water as a heat source is investigated by both experiment and simulation. According to system simulation results, performance improvement of condenser seems more effective than that of evaporator for better $COP_H$. The serial connection is also preferred among several methods to improve plate type heat exchanger performance. The experimental results show that the hot water of $50{\sim}60^{\circ}C$ can be acquired from water heat source of $5{\sim}9^{\circ}C$ with $COP_H$ of $2.7{\sim}3.5$.

  • PDF

Experimental Study of Cooling Energy Saving Verification Using Blinds and Phase Change Material(PCM) (창호 블라인드와 상변화물질 적용에 의한 냉방 에너지 사용량 절감효과에 대한 검토 연구)

  • Song, Young-Hak;Kim, Ki-Tae;Koo, Bo-Kyung;Lee, Keon-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.1
    • /
    • pp.26-31
    • /
    • 2014
  • This study looks into changing building energy use by application of phase change material (PCM). PCM does not need extra energy for operation and is used for reducing building energy use and, CO2 output by displaying semi-permanent effects after installation. It also is able to avoid the maximum electric power time-zone by inducing a time lag phenomenon of cooling and heating loads with high thermal capacity using latent heat. To verify the efficiency of blinds and PCM, tests about the PCM operation mechanism using air conditioning machinery and nocturnal panel cooling were done. In the test results of the case using PCM installation, a $45^{\circ}$ blind angle with machinery air conditioning and nocturnal panel cooling at the same time shows a 22 percent energy saving effect against general space. The test results of each case were compared and analyzed based on the blind and window opening settings. Finally, the energy reduction of existing buildings using PCM application was reviewed based on the final measurement results.

Overview of Milk Allergens and Allergic Reaction Reduction Methods (우유 알레르기의 특성 및 저감화 방법에 대한 고찰)

  • Kim, Ki-Hwan;Seol, Kuk-Hwan;Oh, Mi-Hwa;Park, Beam Young;Kim, Hyoun Wook
    • Journal of Dairy Science and Biotechnology
    • /
    • v.31 no.1
    • /
    • pp.67-73
    • /
    • 2013
  • Food allergy is defined as adverse reactions toward food mediated by aberrant immune mechanisms. Cow's milk allergy is one of the most common food allergies in childhood. This allergy is normally outgrown in the first year of life, however 15% of allergic children remain allergic. Cow's milk allergy seem to be associated with casein (${\alpha}_{s1}$-CN), ${\beta}$-lactoglobulin and whey protein. In addition to this, many other milk proteins are antigenic and capable of inducing immune responses. Various food processing affects the stability, structure and intermolecular interactions of cow milk proteins, as a result reduction the allergenic capacity. Heating, hydrolysis, chemical, proteolytic and other processes such as gamma-ray irradiation, high pressure, using probiotics treatments of milk to obtain hypoallergenic milk have been developed to reduce allergic reactions.

  • PDF

Study on the Performance Characteristics of Micro Gas Turbine (MGT) Co-generation System (마이크로 가스터빈 열병합장치 성능특성 연구)

  • Hur, Kwang-Beom;Kim, Jae-Hoon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.9 s.114
    • /
    • pp.964-970
    • /
    • 2006
  • Micro gas turbine(MGT) has received attention recently as small-scale distributed power sources. With characteristics such as their small size, lightweight, low maintenance cost and minimal vibrations during operation, they are expected to become widespread in a wide range of ' applications, including residential and small-scale industrial use. It is very easier to start-up and stop the MGT system which is the friendly environmental power system has just below the 9ppm NOx emmission and good quality of noise level. The exhaust heat emitted by the MGT is in the form of about $300^{\circ}C$ clean exhaust gas. The exhaust gas is suitable for absorption chiller/heater system. 1 has researched performance characteristics of the 60 kW class MGT-absorption chiller-heater system in the local condition. Variations of heat recovery from exhaust gas has measured according to micro gas turbine output of 15, 30, 45, 60kW. From those results, the performance of the MGT-absorption chiller/heater system has been evaluated.

The Evaluation of NOx Emission Factor from Large Combustion Facilities in Seoul (서울지역 대형연소시설에서의 질소산화물 배출계수 산정)

  • 조기찬;최종욱;박후경;유병태
    • Journal of environmental and Sanitary engineering
    • /
    • v.15 no.4
    • /
    • pp.78-83
    • /
    • 2000
  • The emission factor of nitrogen oxides(NOx) was evaluate to clarify the characteristics of NOx emitted from seven large combustion facilities in seoul area. The emission factors of NOx at A-1 and A-2 facilities of internal combustion engine were 66.957kgNOx/ton and 20.913kgNOx/ton, respectively. The emission factor of A-1 facility was higher than that of A-2 facility even same internal combustion engine, because A-1 facility adopted SCR(selective catalystic reactor) for reduction of NOx emission factor of A-2, A-4, and A-7 power generation boiler facilities were 4.300kgNOx/ton, 2.460kgNOx/ton and 1.796kgNOx/ton, respectively. The capacity of A-2 facility was about two times than that of A-4 and A-7. These emission factors were lower than those at facilities in other areas of korea, because of using low NOx burner of power generation boiler. The emission factors of NOx at A-3 and A-6 incinerator facilities were 0.147kgNOx/ton and 0.221kgNOx/ton which were lower than other facilities, respectively, because these facilities incinerate municipal solid waste of low heating value and uwe SCR for reducing NOx concentration.

  • PDF