• Title/Summary/Keyword: heating capacity

Search Result 679, Processing Time 0.022 seconds

A study of frequency control of an inverter heat pump for indoor air temperature adjustment (실내온도조절을 위한 인버터 열펌프의 주파수 제어에 관한 연구)

  • Park, Yun-Cheol;Min, Man-Gi
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.10
    • /
    • pp.1262-1272
    • /
    • 1997
  • An experimental study on the frequency control of an inverter heat pump to get the desired indoor room temperature has been conducted for the performance characteristics during the steady, 4, 8, and 16 step frequency operations. The heat pump model used in this study was operated to meet the experimental conditions of ASHRAE standard. The performance of the system was tested by measuring the temperature and pressure of the refrigerant, and cooling capacity, power consumption, etc. of the system. As the controlling frequency steps increased, the running time of the compressor increased as well as the electric consumption of the system and the cooling energy due to the wall heating load. However, the average cooling COP was improved.

Load Analysis and Calculation of Power Conversion System Capacity for Induction Heating Cleaning Device (유도가열방식 세정장치용 전력변환장치 용량 산정 및 부하 분석)

  • Jang, Eun Su;Park, Sang Min;Oh, Chang-Yeol;Lee, Byoung Kuk
    • Proceedings of the KIPE Conference
    • /
    • 2016.11a
    • /
    • pp.37-38
    • /
    • 2016
  • 본 논문에서는 유도가열방식 세정장치의 티타늄 용기 특성을 분석하고 전력변환장치를 설계한다. 코일에 흐를 전류를 계산하기 위한 용량 산정은 기체의 온도 변화량 및 용기 가열 시간을 고려하여 증기 가열에 필요한 열량을 수학적으로 분석하고 설계한 전력변환장치를 시뮬레이션을 통해 검증한다.

  • PDF

Cycle Simulation of an Air Source Heat Pump Using Liquid Injection (액분사 사이클을 이용한 공기 열원 열펌프의 사이클 시뮬레이션)

  • 김욱중;홍용주;남임우;강원일;공용상
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.3
    • /
    • pp.244-250
    • /
    • 2000
  • An air source heat pump using liquid injection technique, which can be applied for very low temperature climate, has been simulated to examine the design options. Comparison between the simulation and experiment has been carried out to validate the simulation method. Effects of various design parameters such as liquid injection rate and injection pressure are Investigated to optimize the performance of the heat pump. Finally, optimal liquid infection rate and injection pressure to maintain sufficient heating capacity and moderate discharge refrigerant temperature are suggested when the heat pump was operated at very low outdoor temperature.

  • PDF

A Theoretical Analysis on the Factors Affecting the Operation of Loop Heat Pipe (루프 히트파이프의 작동에 영향을 미치는 인자에 대한 이론적 분석)

  • Lee Ki-Woo;Chun Won-Pyo;Lee Wook-Hyun;Park Ki-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.12
    • /
    • pp.1107-1116
    • /
    • 2004
  • In this paper, the effects of diverse parameters on the operation of loop heat pipe (LHP), such as particle diameter of sintered porous wick, wick porosity, vapor line diameter, thickness of wick and heating capacity were investigated by a theoretical analysis. A LHP has a wick only in its evaporator for the circulation of working fluid, and utilizes a porous wick structure of which pore size is very small to obtain a large capillary force. The working fluid is water and the material of sintered porous wick is copper. For these different parameters, capillary pressure, pressure drop in wick, pressure drops and temperature distribution were analyzed by a theoretical design method of LHP.

Experimental Study on the Flexural Capacity of AU Composite Beam After the Heating Test (가열 시험을 거친 AU 합성보의 휨 성능에 관한 실험 연구)

  • Kim, Young Ho
    • Journal of Korean Association for Spatial Structures
    • /
    • v.19 no.3
    • /
    • pp.77-83
    • /
    • 2019
  • AU(A plus U-shaped) composite beam was developed for reducing the story height in the residential buildings, and saving the cosrtuction cost of floor structures. Structural performance and economic feasibility of the composite beam have been sufficiently approved through the structural experiments and the analytical studies. Fire safety for the practical application of the composite beam has also been verified through the fire resistance tests and the heat transfer analyses. In this study 2-points bending tests were performed on the four specimens already tested for fire resistance to evaluate the residual bending strength of AU composite beam after fire accident. The same bending test was performed on the one fresh specimen having the same section and span of the specimens for practically comparative study.

Study on the Outdoor Conditions for Air Conditioning Design in Korea (한국의 공기조화설계용 외기조건)

  • 김효경
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.1 no.1
    • /
    • pp.3-11
    • /
    • 1972
  • The outdoor design conditions for the locality are the basic problem in the design of air conditioning system. The ideal solution to the basic problem is to design a building that has a capacity at maximum output just equal to the load which develops the most severe conditions for the locality occur, but in most cases, economics interferes the attainment of the ideal. Studies of weather records show that the most severe conditions do not repeat themselves every year. The weather conditions of principal cities such as Seoul, Inchon, Suwon, Taegu, Chonju, Ulsan, Kwangju, Pusan and Mokpo in Korea have been analyzed to determine the probability of occurrence of certain temperatures according to recent 10 years $(1960\∼1969)$ weather records. The outdoor conditions for winter air conditioning design are shown on Table 2. The outdoor conditions for summer air condioning design are shown on Table 7. Heating degree days are shown on Table 10 and 11.

  • PDF

Studies on Physicochemical and Biological Properties of Depolymerized Alginate from Sea tangle, Laminaria japonicus by Thermal Decomposition -2. Changes in Antimutagenicity Effects and Cholesterol, Glucose and Cadmium(Cd) Binding Capacity of Depolymerized- (다시마(Laminaria japonicaus) Alginate의 가열가수분해에 따른 물리${\cdot}$화학적 및 생물학적 특성에 관한 연구 -2. 저분자 alginate의 항돌연변이효과와 Cholesterol, Glucose 및 카드뮴(Cd) 결합능의 변화-)

  • KIM Yuck-Yong;LEE Keun-Woo;KIM Geon-Bae;CHO Young Je
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.33 no.5
    • /
    • pp.388-392
    • /
    • 2000
  • To improve functionality and characteristics of alginate from the sea tangle, Laminaria japonicus, partially depolymerized alginates (HAG-10, average molecular weight 10,000; HAG-50, average molecular weight 50,000; HAG-100, average molecular weight 100,000) were obtained with hydrolysis of alginate by heating at $12^{\circ}C$. Effects of the depolymerization on physicochemical properties were investigated in the antimutagenicity and binding capacity of cholesterol, glucose and cadmium. In the Ames mutagenicity test using Salmonella typhimurium TA 100, HAG-10, HAG-50, HAG-100 and intact alginate reduced effectively the mutagenicities induced by aflatoxin $B_1 (AFB_1)$ and N-methyl-N'-nitro-N-nitrosoguanidine(MNNG) and HAG-10 showed the strongest antimutagenicity among the tested samples. The binding capacity of cholesterol, glucose and cadmium at different pH in vitro depended highly on molecular weight of alginate, and the changes in binding capacity at different pH was not different.

  • PDF

Development of a New Commercial Grain Cooler (곡물냉각기의 개발)

  • 김동철;김의웅;금동혁;한종규
    • Food Science and Preservation
    • /
    • v.11 no.2
    • /
    • pp.250-256
    • /
    • 2004
  • The objectives of this study were to develop a new commercial grain cooler suited to domestic weather and post-harvesting conditions for paddy, and to evaluate the performance. A prototype grain cooler capable of cooling paddy of 200 tons within 24 hours was developed. The grain cooler was designed to control the refrigeration capacity from 0 to 100% by controlling the capacity of compressor with unloading solenoid valve and by changing the flow rates of hot refrigerant gas flowing into reheater and evaporator from compressor. And a controller with one chip microprocessor was developed to control temperature and relative humidity of cooling air. The maximum cooling capacity of the grain cooler was 35,284㎉/hr at condensing/evaporating pressure of 16.5/3.6 kgf/$\textrm{cm}^2$. Maximum flow rate of cooling air was 120 ㎥/min at static pressure of 279 mmAq. The total maximum required power was 22.8㎾, and total required energy was saved from 26.7 to 33.3% of maximum power depending on operating conditions. The coefficient of performance of refrigeration devices and total coefficient of performance of the grain cooler were 4.71 and 1.8, respectively.

Thermal Performance Analysis of Hybrid heat Supply System for Zero Carbon Green Home (제로카본 그린홈 구현을 위한 하이브리드 열공급 시스템의 열성능 분석)

  • Joo, Hong-Jin;Lee, Kyoung-Ho;Kwak, Hee-Youl
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.6
    • /
    • pp.53-59
    • /
    • 2012
  • This study was carried out to evaluate thermal performance of the renewable hybrid heat supply system with solar thermal system and wood pellet boiler for Zero Carbon Green home of apartment houses. The hybrid heat supply system was set up at Korea Institute Energy Research in 2011. The system was comprised of the wood pellet boiler unit with heat capacity designed as 20,000kcal/hr, a $0.15m^3$ hot water storage tank for space heating, a evacuated tubular solar collector $3.74m^2$ of aperture area at the $20^{\circ}$ install angle, a $0.3m^3$ hot water storage tank. Thermal performance tests for one-house of apartment house were carried out by hot water load and heating load in winter season through the hybrid heat supply system. As a result, hot water energy supplied by the hybrid heat supply system was 11kWh in a day. Solar thermal energy portion was 2.99kWh which is 27% of the total hot water energy supply. wood pellet boiler supply portion was 8.017kWh which is 73% of the total hot water energy supply.

An experimental study on the cooling performance of carbon dioxide heat pump system for fuel cell vehicles (연료전지 자동차용 이산화탄소 열펌프 시스템에서의 냉방 성능에 관한 실험적 연구)

  • Kim Sungchul;Park Minsoo;Kim Min Soo;Hwang Inchul;Noh Youngwoo;Park Moonsoo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.378-383
    • /
    • 2005
  • This experimental study presents the results of the cooling performance test of a $CO_2$ heat pump system for fuel cell vehicles. The experimental facility provides the cool ing and heating environment for cabin and heat releasing component. The test loop is designed to target the cooling capacity of 5kW and its coefficient of performance (COP) of 2.2. The cooling performance of the heat pump system is strongly dependent on the refrigerant charge and the degree of superheat. We carried out basic experiments to obtain optimum refrigerant charge and the degree of superheat level at the internal heat exchanger outlet. The heat pump system for fuel cell vehicles is different from that of engine-driven vehicles, where the former has an electricity-driven compressor and the latter has the belt-driven (engine-driven) compressor. In the fuel cell vehicle, the compressor speed is an independent operating parameter and it is controlled to meet the cooling/heating loads. Experiments were carried out at cooling mode with respect to the compressor speed and the incoming outdoor air speed. The results obtained in this study can provide the fundamental cool ing performance data using the $CO_2$ heat pump system for fuel cell vehicles.

  • PDF