Design of Low-Melting Metal Fuse Elements of Current Sensing Type Protection Device for Large Capacity Secondary Battery Protection System (대용량 이차전지 보호 시스템용 전류 감지 동작형 보호소자의 저융점 금속 가용체 설계)

  • Kim, Eun Min;Kang, Chang yong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.31 no.6
    • /
    • pp.427-432
    • /
    • 2018
  • High-capacity secondary batteries can cause explosion hazards owing to microcurrent variations or current surges that occur in short circuits. Consequently, complete safety cannot be achieved with general protection that is limited to a mere current fuse. Hence, in the case of secondary batteries, it is necessary for the protector to limit the inrush current in a short circuit, and to detect the current during microcurrent variations. To serve this purpose, a fuse can be employed for the secondary battery protection circuit with current detection. This study aims at designing a protection device that can stably operate in the hazardous circumstances associated with high-capacity secondary batteries. To achieve the said objective, a detecting fuse was designed from an alloy of low melting point elements for securing stability in abnormal current states. Experimental results show that the operating I-T and V-T characteristic constraints can be satisfied by employing the proposed current detecting self-contained low melting point fuse, and through the resistance of the heating resistor. These results thus verify that the proposed protection device can prevent the hazards of short circuit current surges and microcurrent variations of secondary batteries.

An experimental and numerical analysis of concrete walls exposed to fire

  • Baghdadi, Mohamed;Dimia, Mohamed S.;Guenfoud, Mohamed;Bouchair, Abdelhamid
    • Structural Engineering and Mechanics
    • /
    • v.77 no.6
    • /
    • pp.819-830
    • /
    • 2021
  • To evaluate the performance of concrete load bearing walls in a structure under horizontal loads after being exposed to real fire, two steps were followed. In the first step, an experimental study was performed on the thermo-mechanical properties of concrete after heating to temperatures of 200-1000℃ with the purpose of determining the residual mechanical properties after cooling. The temperature was increased in line with natural fire curve in an electric furnace. The peak temperature was maintained for a period of 1.5 hour and then allowed to cool gradually in air at room temperature. All specimens were made from calcareous aggregate to be used for determining the residual properties: compressive strength, static and dynamic elasticity modulus by means of UPV test, including the mass loss. The concrete residual compressive strength and elastic modulus values were compared with those calculated from Eurocode and other analytical models from other studies, and were found to be satisfactory. In the second step, experimental analysis results were then implemented into structural numerical analysis to predict the post-fire load-bearing capacity response of the walls under vertical and horizontal loads. The parameters considered in this analysis were the effective height, the thickness of the wall, various support conditions and the residual strength of concrete. The results indicate that fire damage does not significantly affect the lateral capacity and stiffness of reinforced walls for temperature fires up to 400℃.

A Study on the Improvement of Performance for Centralized Air Conditioning System by Using Air-Cooled Air Conditioner - The Case of Mokpo National Maritime University - (공랭식 에어컨을 이용한 중앙 집중 공조시스템의 성능 개선에 관한 연구 - 실습선 새누리호를 중심으로 -)

  • Kim, Hong-Ryel;Han, Seung-Hun
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.19 no.2
    • /
    • pp.207-212
    • /
    • 2013
  • In this study, distributed the ship's Centralized Air Conditioning System the way an individual to replace the air conditioning system by using Air-cooled air conditioner. Research results, Individually separated air conditioning system complement the heat source control and thermal efficiency problems and improves the efficiency of the device was confirmed. In addition, under the same conditions refrigeration capacity and coefficient of performance of the device, an average of about 3 %, 23 ~ 26 %, higher, Chilled Water Plants Compressor power consumption is about 12 % lower. Also while heating under the same conditions, power consumption is about 33.5 % lower. Therefore Individually Separated Air Conditioning System greatly contributed to the improved performance of the device and living spaces for comfortable temperature and humidity control as well as heating source could be obtained.

Effects of pH, Temperature, and Protein Content on Water Binding Capacity of Hog Plasma Protein (pH, 온도, 단백질함량에 따른 돼지혈장 단백질의 보수력 변화)

  • Kim, J.B.;Yi, Y.H.
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.18 no.2
    • /
    • pp.195-198
    • /
    • 1989
  • The water binding capacity (WBC) of hoe plasma protein was investigated. The centrifugal condition for optimal separation of plasma from hog blood was fixed at 1400 g-force. The WBC of 5%-plasma-protein-solution eel increased rapidly between pH 6 and 7 but gradually after pH 7 at $85^{\circ}C$ for 30 min. The higher heating temperature demonstrated the higher WBC of 5%-plasma-protein-solution gel at pH 7 within short period of time. The WBC of 5%-plasma-protein-solution gel increased rapidly at the beginning of heating. The WBC per gram of plasma protein at pH 7 and $85^{\circ}C$ for 30 min decreased as protein concentration of the plasma solution increased.

  • PDF

A Study on Durability Variation of Concrete due to Water Content Changes (콘크리트 내 수량증감에 의한 내구 품질 변동에 관한 연구)

  • Woo, Young-Je;Ryu, Hwa-Sung;Jung, Sang-Hwa;Kwon, Ki-Jun
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.7 no.2 s.25
    • /
    • pp.1-6
    • /
    • 2007
  • When the water content within concrete swells, diverse problems occur such as drop in durability. Due to this reason, a change is being managed in the unit water contents by using electric capacity measurements, high frequency heating methods, and unit-volume mass measurements, which are methods of measuring the unit water contents. Particularly, Japan is prescribing the guideline of management on a change in unit water content unit quantity $({\pm}10,\;15,\;20kg//m^3,\;etc.)$. However, the guideline of Japan dose not consider a fall in durability, and is decided on the value of pass-fail criteria by random fabrication errors and measurement errors. Consequently, this study was aimed to investigate the influence of a change In water content within concrete due to an addend caused by management error and to an artificial addend, upon drop in durability.

Development of Fine Bamboo Leaf Powder and Its Color Stability (미세 댓잎분말의 개발 및 색의 안정화)

  • Kim, Ji Myoung;No, Junhee;Shin, Malshick
    • Korean journal of food and cookery science
    • /
    • v.31 no.4
    • /
    • pp.405-412
    • /
    • 2015
  • To develop a color stable and fine bamboo leaf powder (BLP) as a functional green biomaterial, bamboo leaf (BL) purchased from Sasa borealis and cultivated in Damyang, Jeonnam was treated with different conditions and BLP was evaluated. The four treatments comprised of boiling in water, in zinc chloride, sodium bicarbonate, and vinegar solutions, BLP4 was treated with 2% $ZnCl_2$ for 1 h, BLP5 was treated with 1% $ZnCl_2$ for 2 h, and BLP6 was treated with 1% $ZnCl_2+10%$ NaCl for 1 h. The particle size distribution, ash content, water binding capacity, and color change after heating in acidic solution were compared to commercial fine green tea (GTP) and bamboo leaf powders (CBLP). The particle size (cumulative 90%) of BLP was finest in BLP4 followed by BLP6 < BLP5 < GTP < CBLP. The water binding capacity of GTP was the highest and that of BLP was negatively correlated with particle size. After heating in acidic solution, the color of commercial GTP and CBLP changed from bright green to olive green, but the treated BLPs remained bright green. Especially, the -a (greenness) values for the commercial powders decreased from 11.2-13.6 to 3.1-3.8, while those of the treated BLPs did not change.

Rapid Thawing of Frozen Pork by 915 MHz Microwave (915 MHz Microwave를 이용한 동결 돈육의 급속 해동)

  • Lee, Jong-Kyung;Park, Ji-Yong
    • Korean Journal of Food Science and Technology
    • /
    • v.31 no.1
    • /
    • pp.54-61
    • /
    • 1999
  • A study was conducted to find a rapid thawing method which prevents excessive drip loss and local overheating. Effects of thawing methods (conventional thawing vs. 2,450 and 915 MHz microwave thawing) on thawing time, temperature profile, drip loss, water holding capacity, total color difference and total aerobes were investigated. Samples were thawed at 4, 28 and $50^{\circ}C$ in a refrigerator or an oven for the conventional thawing methods the convertional thawing methods. Power levels of 5, 10 and 15 kW were used for 915MHz microwave thawing. Cotreatment of 915 MHz microwave and convectional heating $(120^{\circ}C)$ was tested. 915 MHz microwave accelerated the thawing rate, and showed significant effects on penetration depth, drip loss, water holding capacity and total aerobes. Cotreatment of 915 MHz microwave and convection heating was appeared to be a suitable thawing process for the food industry.

  • PDF

A Study on Performance Improvement of Heat Pump Adopting the Hot Gas Bypass Method (고온냉매 우회방법을 적용한 열펌프의 성능 개선 연구)

  • Kang, Shin-Hyung;Byun, Ju-Suk
    • Journal of Energy Engineering
    • /
    • v.15 no.4 s.48
    • /
    • pp.235-242
    • /
    • 2006
  • This study experimentally investigates the performance improvement of the heat pump by adopting the hot gas bypass method and using the internal heat exchanger according to the automatic defrost test conditions of ISO 5151 This study compares the hot gas bypass method with the time step method, and investigates effect on outdoor coil fan speed when the hot gas of compressor outlet enter outdoor coil inlet after the frost formation. The tests were made for the fan speeds of the outdoor coil controlled at 90, 60 and 30% of the normal speed together with the case of the stationary fan. The performance of the heat pump is evaluated by variables such as COP, heat capacity, and the average COP during the 210 minutes heating mode. Results show that average COP of the hot gas bypass mettled is $2.2{\sim}6%$ higher than that of the time step method. When the outdoor coil fan speed is 60% (780 rpm) of the normal speed, it shows the best COP and heating capacity.

Study on the Fly-back Topology of New Power Feed-back Method for Active Cell Balancing (엑티브 셀 밸런싱을 위한 새로운 전력 피드백 방식의 플라이백 토폴로지에 관한 연구)

  • Seong-Yong Kang;Myeong-Jin Song;Seong-Mi Park;Sung-Jun Park;Jae-Ha Ko
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.6_2
    • /
    • pp.1083-1095
    • /
    • 2023
  • Recently, the demand for low-voltage, high-capacity ESS is rapidly increasing due to the revitalization of the e-mobility industry, which is mainly powered by electricity. In addition, the demand for portable power banks is rapidly increasing due to the revitalization of leisure industries such as camping and fishing. The ESS with this structure consists of a small number of series cells and many parallel cells, resulting in a system with a large rated current. Therefore, the number of power devices for cell balancing configured in series is small, but a balancing device with a large current capacity is required. Construction of a constant temperature device in such a low-voltage, high-current ESS is difficult due to economic issues. The demand for an active balancing system that can solve the passive balancing heating problem is rapidly increasing. In this paper, propose a power feedback fly-back topology that can solve the balancing heating problem. The characteristic of the proposed topology is that a series-connected voltage sharing voltage is used as the input of the flyback converter, and the converter output is connected to one transformer. In this structure, the converter output for cell voltage balancing shares magnetic flux through one high-frequency transformer, so the cell voltage connected to the converter automatically converges to the same voltage.

Performance of Heat Pumps Charged with R170/R290 Mixture (R170/R290 혼합냉매 적용 히트펌프 성능 평가)

  • Park, Ki-Jung;Lee, Cheol-Hee;Jung, Dong-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.9
    • /
    • pp.590-598
    • /
    • 2008
  • In this study, performance of R170/R290 mixtures is measured on a heat pump bench tester in an attempt to substitute R22. The bench tester is equipped with a commercial hermetic rotary compressor providing a nominal capacity of 3.5kW. All tests are conducted under the summer cooling and winter heating conditions of $7/45^{\circ}C$ and $-7/41^{\circ}C$ in the evaporator and condenser respectively. During the tests, the composition of R170 is varied from 0 to 10% with an interval of 2%. Test results show that the coefficient of performance (COP) and capacity of R290 are up to 15.4% higher and 7.5% lower than those of R22 for both conditions respectively. For R170/R290 mixture, the COP decreases and the capacity increases with an increase in the amount of R170. The mixture of 4%R170/96%R290 shows the similar capacity and COP as those of R22. For the mixture, the compressor discharge temperature is $16{\sim}30^{\circ}C$ lower than that of R22. There is no problem with mineral oil since the mixture is mainly composed of hydrocarbons. The amount of charge is reduced up to 58% as compared to R22. Overall, R170/R290 mixture is a good long term 'drop-in' candidate to replace R22 in residential air-conditioners and heat pumps.