• Title/Summary/Keyword: heated needle

Search Result 24, Processing Time 0.027 seconds

The xps study of the Cu-Zn nanofiber

  • Jeong, Eunkang;Kang, Yujin;Park, Juyun;Kang, Yong-Cheol
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.236.2-236.2
    • /
    • 2015
  • The copper-zinc(Cu-Zn) nanofiber was prepared by electrospinning method. The Cu/PVP (polyvinylpyrrolidone) and Zn/PVP precursor solutions were prepared by dissolution of copper sulfate and zinc acetate in methanol, respectively. The PVP was used to control the viscosity of the precursor solutions. The optimized ratio for the Cu/PVP and Zn/PVP nanofibers was determined separately. Then the suitable ratio of the precursor solutions was applied for fabrication of Cu/Zn/PVP nanofiber. For the electrospinning method, the precursor solutions were filled in a syringe. The distance between metallic needle on the syringe and collector was fixed at 16 cm and the voltage was applied on the tip was 13.0 kV. And the as-spun nanofiber was heated at 353K for removal of residual solvent. Then the heated nanofibers were calcined at 973K to decompose PVP. The obtained Cu, Zn, and Cu-Zn nanofibers were investigated with X-ray photoelectron spectroscopy (XPS) for the chemical properties, scanning electron microscopy (SEM) for the morphologies, and X-ray diffraction (XRD) to characterize the crystallinity and phase of nanofibers.

  • PDF

Clinical Assessment of Warm Acupuncture Therapy System Using HF Time-varying Magnetic Field (고주파 자기장을 이용한 온침 치료시스템의 임상 평가)

  • Lee, Su-Yong;Byeon, Sang-Jun;Choi, Ye-Bin;Kim, Jin-Ju;Lee, Yong-Heum
    • Korean Journal of Acupuncture
    • /
    • v.33 no.4
    • /
    • pp.213-220
    • /
    • 2016
  • Objectives : The aim of this paper is to develop acupuncture needle heating system by utilizing the new method which uses high frequency(HF) time-varying magnetic field. Also, it is possible to make an assessment for reliability and clinical significance of the system. Methods : We designed the system with solenoid coils for generation of HF time-varying magnetic field that oscillates at 150 kHz. Acupuncture needles are quickly magnetized and heated by 150 kHz. We assessed clinical significance of system, such as body temperature, pressure pulse waveform. Results : Temperature of acupuncture needle increased up to 60 degree. In the result for clinical significance of system, in case of manual acupuncture stimulation(MAS), body temperature change was $0.373^{\circ}C{\pm}0.224$(p<0.05), rate of pulse energy change increased about 7.6%. In case of warm acupuncture stimulation(WAS), body temperature change was $0.645^{\circ}C{\pm}0.281$(p<0.05), rate of pulse energy change remarkably increased about 35.9%. Conclusions : We confirm that the system is able to be applied clinically to various warm acupuncture needle therapy in the area of oriental medicine.

Synthesis of Sub-Micron MgH2 using Hydriding Thermal Chemical Vapor Synthesis (수소화기상증착공정을 이용한 마그네슘하이드라이드 미세분말 합성)

  • Kang, Taehee;Kim, Jinho;Han, Kyusung;Kim, Byunggoan
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.23 no.5
    • /
    • pp.455-460
    • /
    • 2012
  • This work describes the hydriding chemical vapor synthesis (HCVS) of the $MgH_2$ in a hydrogen atmosphere and the product's hydriding-dehydridng properties. Mg powder was used as a starting material to synthesize $MgH_2$ and uniformly heated to a temperature of $600^{\circ}C$ for Mg vaporization. The effects of hydrogen pressure on the morphology and the composition of HCVS-$MgH_2$ were examined by using X-ray diffraction (XRD) and scanning electron microscopy (SEM). It is clearly seen that after the HCVS process, the particle size of synthesized $MgH_2$ was drastically reduced to the submicron or micrometer-scale and these showed different shapes (needle-like nanofibers and angulated plate) depending on the hydrogen pressure. It was found that after the HCVS process, the $H_2$ desorption temperature of HCVS-$MgH_2$ decreased from 380 to $410^{\circ}C$, and the minimum hydrogen desorption tempreature of HCVS-$MgH_2$ powder with needle-like shape can be obtained. In addition, the enhanced hydrogen storage performance for needle-like $MgH_2$ was achieved during subsequent hydriding-dehydriding cycles.

Fabrication of Barium Ferrite Films by Sol-Gel Dip Coating and Its Properties.

  • T. B. Byeon;W. D. Cho;Kim, T. O.
    • Journal of Magnetics
    • /
    • v.2 no.1
    • /
    • pp.16-21
    • /
    • 1997
  • Those were investigated, the crystallographic, morphological, and magnetic properties of barium ferrite film (SiO2/Si substrate) prepared by sol-gel dip coating. Appropriate sol was prepared by dissolvin barium and iron nitrate in ethylene glycol at 80$^{\circ}C$. To obtain the films, thermally oxidized p-type silicon substrate with (111) of crystallographic orientation were dipped into the sol, dried at 250$^{\circ}C$ to remove organic material, and heated at 800$^{\circ}C$ for 3 hours in air for the crystallization of barium ferrite. It was found that the particles of barium ferrite formed on the substrate exhibited needle-like shape placing parallel to the substrate and its c-axis is long axis direction. There was tendency that the coercive force in horizontal direction to the substrate was higher than that in vertical direction to it. This tendency was profound in large thickness.

  • PDF

A Study on Historical Research for Costume of Banya(般若) in King Gongmin's Period of Late Goryeo - Focused on the Buddhist Service Costume - (고려 말 공민왕 재위기의 반야(般若) 복식 고증요소 고찰 - 불교법회 복식을 중심으로 -)

  • Choi, Jeong
    • Journal of the Korean Society of Costume
    • /
    • v.65 no.6
    • /
    • pp.112-132
    • /
    • 2015
  • Banya was a concubine slave of Shindon(辛旽) who was a powerful monk in late Goryeo Dynasty, as well as the mother of King Woo(禑王), a successor of King Gongmin(恭愍王). This study was undertaken to investigate the sources of costume for Banya. The study focused on the features of Buddhist service costume, street wear, and daywear for common women's costume during the prime age of the Buddhist culture. The study looked into Buddhist paintings, old documents, advanced research, and relics. There are three characteristics of historically investigated Buddhist service costume for Banya: Dallyeongpo(團領袍), long Jeogori made with black Ra(羅), and Jeogori with a long scarf. Skirt, under Jeogori, under skirt, Cho, Ra(羅), Neung (綾), Dan(緞), patterned ramie(紋紵), and Tapja(塔子) were included in all Buddhist service costume. And, street wear consisted of Women's Dapho(婦人搭忽), long Jeogori, skirt, underwear and black Ra beil(蒙首). Daywear consisted of Banbi(半臂), long Jeogori, and skirt, underwear made with cheap fabric, Ju(綢), ramie, and imported cotton. Plumper hair, silver comb and Biyeo, lining of light pink-colored thin silk(小紅薄絹), bronze openworked ornament that fixed the outerwear's opening, bronze needle case, Sutra box and heated gemstone could be matched for the Buddhist service costume. Bronze and heated gemstone could be used for ornaments of street wear and daywear. The investigation of ornaments was carried on by referring to presentation of overseas collections. Considering the limitation of the study on Goryeo costume due to the lack of research material, future studies including much more relics in oversea collections needs to be undertaken.

A Study on the Processing of Long Fiber-Reinforced Composite Materials for Thermoforming On the Correlation Coefficient between Separation and Orientation (Thermoforming용 長纖維强化 複合材料의 成形工程에 관한 硏究 分離$\cdot$配向의 相關계수)

  • 이동기;김정락;김상필;이우일;김이곤
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.5
    • /
    • pp.1106-1114
    • /
    • 1993
  • A composite material is composed of a reinforcement and a matrix, which determine mechanical characteristics of the molded part. There is no doubt that the properties of a composite material depend not only on the characteristics of the matrix but also on the structure of glass fiber mat and a fiber type of reinforcement. Therefore it is very important to study the composites of reinforcement and the matrix, and to control the fiber type in the process of molding of composite materials. In this study, the specimen was made of a glass fiber mat of 6-7mm thickness by scattering it in the air after cutting the glass fiber mat with needle punching makes change according to the type of needle and the number of times of stretching. First the sheet was made by means of a hot-press after accumulating a matrix and a glass fiber according to each mat structure of glass fiber. It was heated the manufactured sheet with the dry oven and molded it a secondary high temperature compression by a 30 ton oilhydraulic press. A definition of a correlation coefficient is showed up during this period and find it out with the relation of the fiber-matrix separation and the fiber orientation. We studied effects of the glass fiber mat structures on the correlation coefficient.

Interstitial Hyperthermia by Radiofrequency Needle Electrode System : Phantom and Canine Brain Studies (8 MHz 라디오파를 이용한 자입식 온열치료 -조직등가물질을 통한 온도분포 및 개 뇌실질의 조직병리 변화에 관한 연구-)

  • Lee, Hyung-Sik;Chu, Sung-Sil;Sung, Jin-Sil;Suh, Chang-Ok;Kim, Gwi-Eon;Loh-John-Juhn-Kyu;Kim, Young-Soo;Kim, Sun-Ho;Chung, Song-Sup;Han, Eun-Kyung;Kim, Tae-Seung
    • Radiation Oncology Journal
    • /
    • v.9 no.1
    • /
    • pp.27-35
    • /
    • 1991
  • An interstitial radiofrequency needle electrode system was constructed for interstitial heating of brain tissue. Radiofrequency electrodes with Thermotron RF 8 were tested in an agar phantom and in a normal canine brain to determine how variations in physical factors affected temperature distributions. Temperature distributions were checked after heating with 1 mm diameter needle electrode implants on the corners of 1 and 2 cm squares in a phantom and plot isotherms for various electrodes arrangement. We observed that the 1 cm square array would heat a volume with a 1.25 cm radius circular field cross section to therapeutic temperatures ($90\%$ relative SAR using Tm) and the 2 cm square array with a 1.75 cm radius rectangular field with central inhomogeneity. With 2 cm long electrode implants, we observed that the 1 cm square array would heat a 3 cm long sagittal section to therapeutic temperature ($90\%$ relative SAR using Tm). We found that radiofrequency electrodes could be selected to match the length of the heating area without affecting its performance. The histopathological changes associated with RF heating of normal canine brains have been correlated with thermal distributions. RF needle electrode heating was applied for 50min to generate tissue temperatures of $43^{\circ}C$. We obtained a quarter of the heated tissue material immediately after heating and sacrificed at intervals from $7\sim30$days. The acute stage (immediately after heating) was demonstrated by liquefactive necrosis, pyknosis of neuronal element in the gray matter and by some polymer-phonuclear leukocytes infiltration. The appearance of lipid-laden macrophages surrounding the area of liquefaction necrosis was demonstrated in all three sacrificed dogs. Mild gliosis occurring around the necrosis was demonstrated in the last sacrificed (Days 30) canine brain.

  • PDF

Synthesis and Characterization of Fiberous AlN by Electrospinning (전기방사에 의한 섬유상 질화알루미늄 합성 및 특성 평가)

  • Chun, Seung-Yeop;Hwang, Jin-Ah;Chu, Jae-Uk;Chun, Myoung-Pyo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.30 no.7
    • /
    • pp.441-446
    • /
    • 2017
  • Aluminum nitride fibers were synthesized by carbothermal reduction and nitridation of precursor fibers obtained by electrospinning. The starting materials used to synthesize the AlN fibers were $Al(NO_3)_3{\cdot}9H_2O$ and urea. Polyvinylpyrrolidone with increasing viscidity was used as the carbon source to obtain a composite solution. The mixed solution was drawn into a plastic syringe with a stainless steel needle, which was used as the spinneret and connected to a 20 kV power supply. A high voltage was supplied to the solution to facilitate the formation of a dense net of fibers on the collector. The precursor fibers were dried at $100^{\circ}C$ and then heated to $1,400^{\circ}C$ for 1 h in a microwave furnace under $N_2$ gas flow for the carbothermal reduction and nitridation. X-ray diffraction studies indicated that the synthesized fibers consisted of the AlN phase. Field emission scanning electron microscopy studies indicated that the diameter of the calcined fibers was approximately 100 nm.

SURFACE CHARACTERISTICS AND BIOLOGICAL RESPONSES OF HYDROXYAPATITE COATING ON TITANIUM BY HYDROTHERMAL METHOD: AN IN VITRO STUDY

  • Kim, Dong-Seok;Kim, Chang-Whe;Jang, Kyung-Soo;Lim, Young-Jun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.3
    • /
    • pp.363-378
    • /
    • 2005
  • Statement of problem. Hydroxyapatite(HA) coated titanium surfaces have not yet showed the reliable osseointegration in various conditions. Purpose. This study was aimed to investigate microstructures, chemical composition, and surface roughness of the surface coated by the hydrothermal method and to evaluate the effect of hydrothermal coating on the cell attachment, as well as cell proliferation. Material and Methods. Commercially pure(c.p.) titanium discs were used as substrates. The HA coating on c.p. titanium discs by hydrothermal method was performed in 0.12M HCl solution mixed with HA(group I) and 0.1M NaOH solution mixed with HA(group II). GroupⅠ was heated at 180 $^{\circ}C$ for 24, 48, and 72 hours. GroupⅡ was heated at 180 $^{\circ}C$ for 12, 24, and 36 hours. And the treated surfaces were evaluated by Scanning electron microscopy(SEM), Energy dispersive X-ray spectroscopy(EDS), X-ray photoelectron spectroscopy(XPS), X-ray diffraction method(XRD), Confocal laser scanning microscopy(CLSM). And SEM of fibroblast and 3-(4,5- dimethylthiazol-2-yl)-2,5-diphenyl tetrazolium bromide(MTT) assay were used for cellular responses of the treated surfaces. Results. The color of surface changed in both groups after the hydrothermal process. SEM images showed that coating pattern was homogeneous in group II, while inhomogeneous in group I. H72 had rosette-like precipitates. The crystalline structure grew gradually in group II, according to extending treatment period. The long needle-like crystals were prominent in N36. Calcium(Ca) and phosphorus(P) were not detected in H24 and H48 in EDS. In all specimens of group II and H72, Ca was found. Ca and P were identified in all treated groups through the analysis of XPS, but they were amorphous. Surface roughness did not increase in both groups after hydrothermal treatment. The values of surface roughness were not significantly different between groups I and II. According to the SEM images of fibroblasts, cell attachments were oriented and spread well in both treated groups, while they were not in the control group. However, no substantial amount of difference was found between groups I and II. Conclusions. In this study during the hydrothermal process procedure, coating characteristics, including the HA precipitates, crystal growth, and crystalline phases, were more satisfactory in NaOH treated group than in HCl treated group. Still, the biological responses of the modified surface by this method were not fully understood for the two tested groups did not differ significantly. Therefore, more continuous research on the relationship between the surface features and cellular responses seems to be in need.

Fabrication of Combined Probes for Interstitial hyperthermia and Brachyradiotherapy (고 선량율 근접 및 온열치료 병용 삽입관의 제작과 특성)

  • Chu, Sung-Sil;Kim, Sung-Kyu
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2004.11a
    • /
    • pp.85-87
    • /
    • 2004
  • We fabricated flexible thermoradiotherapy probes to alternated combination with Interstitial hyperthermia and Brachyradiotherapy thermoradiotherapy probe was coated by gold plate on polyethylene brachytherapy probe. When Agar phantom was heated 15 minute with 30 W radiofrequency power, temperature increased as 5oC for polyethylene probe and 20oC for gold coated polyethylene probe. We observed that the 1 cm square array would heat a volume with a 1.25 cm radius circular field cross section to therapeutic temperatures (90% relative SAR using Tm) and the 2 cm square array with a 1.75 cm radius rectangular field with central inhomogeneity. With 2 cm long electrode implants, we observed that the 1 cm square array would heat a 3 cm long sagittal section to therapeutic temperature (90% relative SAR using Tm). The histopathological changes associated with RF heating of normal canine brains have been correlated with thermal distributions. RF needle electrode heating was applied for 50 min to generate tissue temperatures of 43${\circ}$C. We obtained a quarter of the heated tissue material immediately after heating and sacrificed at intervals from 7${\sim}$30 days. The acute stage was demonstrated by liquefactive necrosis, pyknosis of neuronal element in the gray matter. Mild gliosis occurring around the necrosis was demonstrated in the last sacrificed (days30)canine brain.

  • PDF