• 제목/요약/키워드: heat transport

검색결과 756건 처리시간 0.029초

삼각단면 극소히트파이프의 작동특성에 관한 기초 연구 (Fundamental study on performance characteristics of a micro heat pipe with triangular cross section)

  • 문석환;김종오;김철주
    • 설비공학논문집
    • /
    • 제11권2호
    • /
    • pp.176-184
    • /
    • 1999
  • Numerical and experimental studies were performed to examine the characteristics of heat and mass transfer processes for a Micro Heat Pipe(MHP) with a triangular cross-section. Solutions on mass flow rate, pressure variation, and radius of meniscus were obtained using the mathematical model developed by Faghri and Khrustalev. To obtain an increase in capillary limitation, a triangular tube with curved walls was designed and fabricated. The measurement by microscope showed that the radius at corners of the tube was ranging between 0.03-0.05mm. Performance test for MHPs using the triangular tube with curved walls proved a substantial increasement in heat transport limitation, with 4.5W and 2.0W in case of using water and ethanol as a working fluid, respectively. In the previous study by Faghri a limitation of 0.5W was reported for a water MHP with a regular triangular tube.

  • PDF

Optimization of the growth of $CaF_2$ crystals by model experiments and numerical simulation

  • Molchanov, A.;Graebner, O.;Wehrhan, G.;Friedrich, J.;Mueller, G.
    • 한국결정성장학회지
    • /
    • 제13권1호
    • /
    • pp.15-18
    • /
    • 2003
  • High purity single crystalline calcium fluoride ($CaF_2$) has excellent optical transmission characteristics down to deep UV and is therefore selected as the main optical material for the next generation of lithography apparatus operating at wavelength of 157 nm. The growth of large sized $CaF_2$ single crystals with the required properties for this optical application can be achieved only by optimizing the crystal growth process by the aid of numerical simulation. This needs especially a precise calculation of the heat transport and temperature distribution in the solid and liquid $CaF_2$ under crystal growth conditions. As $CaF_2$ is considered to be semitransparent, the internal radiative heat transfer in $CaF_2$ plays an decisive role in the simulation of the heat transport. On the other hand it is very difficult to obtain quantitative experimental data for evaluating numerical models as $CaF_2$ is extremely corrosive at high temperatures. In this work we present a newly developed experimental technique to perform temperature measurements in $CaF_2$-crystal as well as in the melt under conditions of crystal growth process. These experimental results are compared to calculated temperature data, which were obtained by using different numerical models concerning the internal heat transfer in semitransparent $CaF_2$. It will be shown, that an advanced model, which was developed by the authors, gives a much better agreement with experimental data as a standard model, which was taken from the literature.

Evaluation of Water Retentive Pavement as Mitigation Strategy for Urban Heat Island Using Computational Fluid Dynamics

  • Cortes, Aiza;Shimadera, Hikari;Matsuo, Tomohito;Kondo, Akira
    • Asian Journal of Atmospheric Environment
    • /
    • 제10권4호
    • /
    • pp.179-189
    • /
    • 2016
  • Here we evaluated the effect of using water retentive pavement or WRP made from fly ash as material for main street in a real city block. We coupled computational fluid dynamics and pavement transport (CFD-PT) model to examine energy balance in the building canopies and ground surface. Two cases of 24 h unsteady analysis were simulated: case 1 where asphalt was used as the pavement material of all ground surfaces and case 2 where WRP was used as main street material. We aim to (1) predict diurnal variation in air temperature, wind speed, ground surface temperature and water content; and (2) compare ground surface energy fluxes. Using the coupled CFD-PT model it was proven that WRP as pavement material for main street can cause a decrease in ground surface temperature. The most significant decrease occurred at 1200 JST when solar radiation was most intense, surface temperature decreased by $13.8^{\circ}C$. This surface temperature decrease also led to cooling of air temperature at 1.5 m above street surface. During this time, air temperature in case 2 decreased by $0.28^{\circ}C$. As the radiation weakens from 1600 JST to 2000 JST, evaporative cooling had also been minimal. Shadow effect, higher albedo and lower thermal conductivity of WRP also contributed to surface temperature decrease. The cooling of ground surface eventually led to air temperature decrease. The degree of air temperature decrease was proportional to the surface temperature decrease. In terms of energy balance, WRP caused a maximum increase in latent heat flux by up to $255W/m^2$ and a decrease in sensible heat flux by up to $465W/m^2$.

스프링클러헤드 감열부의 열적 특성에 관한 연구 (An Investigation on the Thermal Characteristics of Heat-Responsive Element of Sprinkler Head)

  • 유우준;문효준;염문천;유홍선
    • 한국화재소방학회논문지
    • /
    • 제26권3호
    • /
    • pp.79-84
    • /
    • 2012
  • 본 연구에서는 국내외 스프링클러헤드 감도시험 기준에 적용하고 있는 반응시간지수(RTI, Response Time Index)를 사용하여 대류항과 전도항 그리고 시간 변화량을 고려한 감열부의 열전달 현상을 해석적으로 분석하였다. 원형 실린더 형상을 갖는 감열부의 열적 특성을 분석하기 위해서 비제차 2차 편미분 형태의 에너지 방정식을 사용하여 감열부 표면의 온도가 일정하고 대칭(Symmetric)인 경계조건을 적용하여 시간 증가에 대한 감열부의 반지름 방향 온도분포를 구하였다. 그 결과 본 연구의 감열부 열적 특성에 관한 분석 기법은 스프링클러헤드의 감도시험 및 감열부의 설계를 위한 자료의 활용이 가능할 것으로 판단된다.

고감성 의류용 복합사 직물의 수분증기 및 열이동 특성 -실험방법에 따른 수분증기 및 열이동- (Water Vapor and Thermal Transmission Properties of Hybrid Yarns Fabrics for High Emotional Garments -Water Vapor and Heat Transport according to Experimental-Method-)

  • 김승진;김현아
    • 한국의류학회지
    • /
    • 제41권1호
    • /
    • pp.84-97
    • /
    • 2017
  • Water vapor and thermal transmission properties of high emotional garments are important to evaluate wear comfort; in addition, the measuring methods of these properties are also critical for breathable and warm suit fabrics. In this study, the water vapor and thermal properties of composite yarn fabrics made of CoolMax, Tencel, and Bamboo fibers with filaments were measured and compared according to the measuring method. Water Vapor Transmittance (WVT) of the fabric woven by the sheath/core composite yarn in the warp direction was the highest due to the small staple fiber volume in the sheath/core yarn structure and high air voids in the sheath/core yarn fabrics. This property was also the highest in fabrics woven by bamboo staple yarns in the weft direction, and was the lowest on hi-multi filament fabrics. However, water vapor resistance ($R_{ef}$) of these fabrics by KSK ISO 11092 showed the opposite results to the water vapor transmittance method ($CaCl_2$ method); in addition, its correlation coefficient was low. The correlation coefficient between $R_{ef}$ and the drying rate was 0.719; therefore, the measurement mechanism of $R_{ef}$ is analogous to the drying property measurement. The thermal conductivity of the fabrics woven with compact staple yarn showed a high value; however, the hi-multi filament fabric showed low thermal conductivity. Therefore, fiber characteristics affect thermal properties more than yarn structure. The correlation between thermal property and moisture transport was also low. This study showed that: water vapor transmittance was active at the loose yarn structure, dry heat transport was vigorous at the compact yarn structure, and heat transport was affected more by fiber characteristics than yarn structure. In conclusion, sheath/core composite yarns were relevant to the high absorptive cool suit along with siro-fil and CoolMax/Bamboo staple yarns that were relevant to the heat diffusive cool suit.

지표 특성 변화에 대한 평형온도의 반응 연구 : EBM 연구 (On response of Surface Equilibrium Temperature for Change of Surface Characteristics : An EBM Study)

  • 서예원;추정은;하경자
    • 한국제4기학회지
    • /
    • 제24권2호
    • /
    • pp.1-11
    • /
    • 2010
  • 지표 특성 차이에 따라 외부강제력에 대한 차별적인 반응을 보이는 지표 평형온도 분포를 실험하기 위해 에너지 균형 모형(Energy Balance Model, EBM)이 사용되었다. EBM은 입사되는 복사에너지가 각 위도별로 수송되는 에너지와 방출되는 복사에너지의 합과 균형을 이루었을 때의 온도를 산출한다. 지구의 에너지 원천인 태양복사에너지를 전지구 에너지 균형에 있어 중요하게 취급하기 위하여 위도별 알베도 변화뿐만 아니라 해륙의 분포 차이에 따른 에너지 균형을 고려한 지구 평형온도 분포에 관한 실험이 수행되었으며, 입사되는 태양복사에너지량을 강제력으로 하여 위도별 알베도의 선형적인 증감, 극지역 알베도의 5%, 10%, 15% 증감에 대한 반응, 극과 중위도 지역에서의 상반된 증감에 대한 반응을 실험하였다. 그리고 얼음-알베도 피드백의 유무에 대한 실험도 수행되었다. 극지역의 알베도를 증가시키면 입사되는 태양에너지를 차단시켜 위도별 열수송을 감소시키는데 이는 극지역을 저에너지 상태로 유지시킴으로써 저위도에서부터의 에너지 수송을 강화시킨다. 이러한 수송량의 차이로 인해 중위도 지역의 온도 변화는 극지역에 비해 크게 나타난다. 육지는 해양에 비해 열용량이 작기 때문에 평형온도에 도달하는 시간이 짧으며 알베도에 따른 온도변화에 민감하여 해양과의 온도차이를 유발시킨다. 따라서 평형온도는 지표가 가지는 특성인 알베도와 열용량의 차이에 따라 다르게 나타나며 알베도가 증가함에 따라 감소하고 열용량이 작을수록 변화율이 큰 특징이 있다. 얼음-알베도 피드백은 알베도의 선형적인 증가에 따른 지구 평형온도의 감소를 가속화시키지만 국지적으로는 비선형적인 감소를 보인다.

  • PDF

The role of botulinum toxin type A related axon transport in neuropathic pain induced by chronic constriction injury

  • Bu, Huilian;Jiao, Pengfei;Fan, Xiaochong;Gao, Yan;Zhang, Lirong;Guo, Haiming
    • The Korean Journal of Pain
    • /
    • 제35권4호
    • /
    • pp.391-402
    • /
    • 2022
  • Background: The mechanism of peripheral axon transport in neuropathic pain is still unclear. Chemokine ligand 13 (CXCL13) and its receptor (C-X-C chemokine receptor type 5, CXCR5) as well as GABA transporter 1 (GAT-1) play an important role in the development of pain. The aim of this study was to explore the axonal transport of CXCL13/CXCR5 and GAT-1 with the aid of the analgesic effect of botulinum toxin type A (BTX-A) in rats. Methods: Chronic constriction injury (CCI) rat models were established. BTX-A was administered to rats through subcutaneous injection in the hind paw. The pain behaviors in CCI rats were measured by paw withdrawal threshold and paw withdrawal latencies. The levels of CXCL13/CXCR5 and GAT-1 were measured by western blots. Results: The subcutaneous injection of BTX-A relieved the mechanical allodynia and heat hyperalgesia induced by CCI surgery and reversed the overexpression of CXCL13/CXCR5 and GAT-1 in the spinal cord, dorsal root ganglia (DRG), sciatic nerve, and plantar skin in CCI rats. After 10 mmol/L colchicine blocked the axon transport of sciatic nerve, the inhibitory effect of BTX-A disappeared, and the levels of CXCL13/CXCR5 and GAT-1 in the spinal cord and DRG were reduced in CCI rats. Conclusions: BTX-A regulated the levels of CXCL13/CXCR5 and GAT-1 in the spine and DRG through axonal transport. Chemokines (such as CXCL13) may be transported from the injury site to the spine or DRG through axonal transport. Axon molecular transport may be a target to enhance pain management in neuropathic pain.

미세유체 채널 내에서 열영동에 의한 입자이동 제어 (Thermophoretic Control of Particle Transport in a Microfluidic Channel)

  • 소주희;구형준
    • Korean Chemical Engineering Research
    • /
    • 제57권5호
    • /
    • pp.730-734
    • /
    • 2019
  • 열영동은 매질의 온도 구배에 의해 입자가 이동하는 현상이다. 본 논문에서는 미세유체 채널에서 입자의 열영동 현상에 대해서 논의한다. 흐름이 없는 비유동 채널에서 열원인 백금 와이어에 가해지는 전압에 비례해서 열영동에 의한 마이크로 입자의 이동이 더 크게 나타남을 확인하였다. 전압에 따른 백금 와이어 주변 온도 변화는 Callendar-van Dusen 식을 이용하여 예측하였다. 동일한 시스템에서 나노 입자의 열영동 현상을 관찰한 결과, 나노 입자도 마이크로 입자와 유사한 열영동 거동을 보임을 확인하였다. 마지막으로 Y 모양 미세유체 채널을 제작하고 백금 와이어 열원을 채널 내에 설치하여, 채널을 흐르는 현탁액 내의 입자의 열영동 현상을 구현하고, 이를 기반으로 현탁액의 흐름을 제어할 수 있음을 보인다.

채널내 공기유동이 있는 유하액막의 열전달특성에 관한 실험적 연구 (An Experimental study on heat transfer of a falling liquid film in air channel flow)

  • 오동은;강병하;김석현
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2291-2296
    • /
    • 2007
  • Thermal transport from vertical heated surface to falling liquid film in a channel has been investigated experimentally. Air-flow is introduced into channel to make a counter flow against falling liquid film. This problem is of particular interest in the design of direct contact heat exchange system, such as cooling tower, evaporative cooling system, absorption cooling system, and distillation system. The effects of channel width and air flow rate on the heat transfer to falling liquid film are studied in detail. The results obtained indicate that heat transfer rate is gradually decreased with an increase in the channel width without air flow as well as with air flow in a channel. It is also found that heat transfer rate of air-flow is increased while heat transfer rate of falling liquid film is decreased with an increase in the air flow rate at a given channel width. However, total heat transfer rate form the heated surface is increased as the air flow rate is increased.

  • PDF

판형 열교환기의 주요 설계인자와 설계프로그램 개발에 관한 고찰 (Study on Design Factor and Design-code Development for Plate Type Heat Exchangers)

  • 고제현;박권하;송영호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제36권8호
    • /
    • pp.1003-1009
    • /
    • 2012
  • 열교환기는 에너지전달을 필요로 하는 산업분야에 널리 사용되고 있으며 효율이 좋은 판형 열교환기의 비중이 크게 증가되고 있다. 본 연구는 판형열교환기의 최적설계를 위하여 주요설계인자를 분석하고 방정식을 유도하였으며 상용코드와 비교 분석하였다. 판의 쉐브론각에 따른 열전달계수와 압력강하 설계식을 도입하였으며 각각의 설계식은 레이놀즈 수의 함수로 표현되었다. 이 설계식을 이용해 쉐브론 각이 동일한 판을 사용하였을 경우와 쉐브론각이 다른 두 판을 교차한 경우에 대하여 성능 해석하였으며 상용프로그램의 결과와 비교분석하였다. 성능해석을 한 결과 대류열전달계수는 8%이내, 압력강하는 5%이내의 오차로 만족할 만한 결과를 나타냈다.