• 제목/요약/키워드: heat transfer capacity

검색결과 391건 처리시간 0.022초

R22 대체냉매의 성능 평가 (Performance evaluation of R22 alternative refrigerants)

  • 송용재;박봉진;정동수;김종보
    • 설비공학논문집
    • /
    • 제10권3호
    • /
    • pp.292-302
    • /
    • 1998
  • In this study, 14 refrigerant mixtures composed of R32, R125, R134a, R143a, R152a, and R1270(Propylene) were tested in a breadboard heat pump in an attempt to replace R22 used in most of the residential air conditioners and heat pumps. The heat pump was of 1 ton capacity and water was employed as the secondary heat transfer fluids. All tests were conducted under ARI test A condition. Ternary mixtures composed of R32, R125, and R134a were shown to have 4∼5% higher COP and capacity than R22 and hence they seem to be very promising candidates to replace R22. On the other hand, ternary mixtures containing R125, R134a, and R152a have lower COP and capacity than R22. R32/R134a binary mixtures show a 7% increase in COP and have the similar capacity to that of R22 and hence they are also good candidates to replace R22. Special care must be exercised when a suction line heat exchanger is used with these mixtures in air conditioners. Finally, the compressor discharge temperatures of all mixtures tested were lower than those of R22 by 15.g∼34.7t, which indicates that these mixtures would offer better system reliability and longer life time than R22.

  • PDF

건물의 냉방을 위한 해수열 취득에 관한 실험적 연구 (A new method to convert into seawater heat for the indoor air-conditioning resource)

  • 김기철;이성
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제29권8호
    • /
    • pp.883-890
    • /
    • 2005
  • The industrial growth and the raised living quality have led to the massive energy consumption. As a result. the polluted environment and the limited amount of energy resources emerged as serious problems to be resolved in 21st century. Especially, in the case of Korea whose imported energy dependency rate is 98.2$\%$ in 2003 and constantly increasing every rear. more than 24$\%$ of overall energy consumption is for housing and commercial use. In order to cope with the shortage of natural energy resources, it is inevitable to develop alternative sustainable energy resources including seawater heat. so that they can replace existing resources. The heat transfer air velocity 3.5 m/s is proper to consideration with the body the pipe size 200A is more suitable than look due to the air velocity quantify and the ratio of pipe surface area. And the error between experimental data with simulation is below 5.34$\%$ so the suggested equation for calculating heat transfer capacity can be used. Therefore out of many methods utilizing seawater heat. this work Presents the efficiency of using sea water heat as a resource for air-conditioners which can be converted from the outside air through the air-to-heat conversion tube . Consequently. this method provides pretty reasonable energy efficiency.

제습로터의 운전특성을 재배하는 무차원 인자의 도출과 해석 (Derivation and Analysis of Dimensionless Parameters Dominating the Dehumidification Characteristics of a Desiccant Rotor)

  • 이길봉;김민수;이대영
    • 설비공학논문집
    • /
    • 제17권7호
    • /
    • pp.611-619
    • /
    • 2005
  • In a previous work of the authors, the heat and mass transfer in a desiccant rotor was analyzed theoretically through linearization assumptions and four dimensionless parameter groups dominating the dehumidification process were arranged. In this work is verified whether the four dimensionless parameters also play the dominant roles in more realistic situations where the nonlinear factors affect the heat and mass transfer. The results show that the dehumidification characteristics are closely similar to each other as long as the four dimensionless parameters have the same set of values while the rotor configurations and/or the operation conditions are different from each other. The four dimensionless parameters are $\Psi,\;\chi,\;\sigma$ and N, where $\Psi$ implies the average gradient of relative humidity lines in the psychrometric chart, $\chi$ the heat capacity of the rotor and $\sigma$ the sorption capacity of the rotor, and N implies the number of transfer unit.

스크린 윅을 삽입한 동-물 히트파이프에서 모세관 한계에 관한 연구 (A Study on the Capillary Limitation in Copper-Water Heat Pipes with Screen Wicks)

  • 박기호;이기우;노승용;이석호;유성연
    • 설비공학논문집
    • /
    • 제14권12호
    • /
    • pp.1023-1030
    • /
    • 2002
  • This paper is to research the heat transfer characteristic performance of the copper-water heat pipe with the screen wicks. Recently, the semiconductor capacity of an electronic unit has been larger, on the contrary, its size has been much smaller. As a result, a high-performance cooling system is needed. Experimental variables are inclination angles, temperatures of cooling water and the mesh number of screen wicks. The distilled water was used for the working fluid. At the inclination angle $6^{\circ}$ in top heat mode, the two layers of the 100-mesh screen wick showed the best heat transfer performance. The thermal resistance of the two layers with the 100-mesh screen was 0.7~$0.8^{\circ}C$/W.

Second law thermodynamic analysis of nanofluid turbulent flow in heat exchanger

  • K. Manjunath
    • Advances in Energy Research
    • /
    • 제8권3호
    • /
    • pp.125-136
    • /
    • 2022
  • Entropy generation along with exergetic analysis is carried out using turbulent nanofluid flow in the heat exchanger. To obtain the optimized percentage constituent of nanofluid, the nanofluid volume concentrations is varied for the given input conditions. For different Reynolds number of the fluid and heat capacity rate ratio between the streams, the heat transfer improvements are studied in terms of nano particles diameter. Parametric analysis is carried out for a counterflow heat exchanger using turbulent nanofluid flow with exergetic efficiency along with entropy generation number as performance parameters. The exergetic efficiency provides realistic approach in the design of nanofluid applications in heat exchanger leading to conservation of energy.

On-site Performance Test and Simulation of a 10 RT Air Source Heat Pump

  • Baik, Young-Jin;Chang, Young-Soo;Kim, Young-Il
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제12권2호
    • /
    • pp.61-69
    • /
    • 2004
  • In this study, on-site performance test of an air source heat pump which has a rated capacity of 10 RT is carried out. Since indoor and outdoor air conditions can not be controlled to satisfy the standard test conditions, experiments are done with the inlet air conditions as they exist. To estimate the performance of the heat pump for other conditions, the heat pump is modeled with a small number of characteristic parameters. The values of the parameters are determined from the few measurements measured on-site during steady operation. A simulation program is developed to calculate cooling capacity and power consumption at any other arbitrary operating conditions. The simulation results are in good agreement with the experiment. This study provides a method of an on-site performance diagnosis of an air source heat pump.

난류 발생기의 형상에 따른 수직 PCB채널에서의 열전달 및 압력손실 변화 (Heat transfer and pressure drop with the turbulence promoter in a vertical PCB Channel)

  • 박찬우;장승일;정종수;남평우
    • 대한기계학회논문집B
    • /
    • 제20권7호
    • /
    • pp.2277-2288
    • /
    • 1996
  • This study was performed to analyze the cooling effect of heated ribs which are frequently used for cooling of electronic parts, using the numerical method. To prevent the excessive pressure drop due to turbulence promoters for the enhancement of heat transfer rate especially, the effect of the angle of turbulence promoter was investigated by the numerical analysis. Heat transfer rate with turbulence promoters with rectangular cross-section increased by 13% in average, but the coefficient of pressure drop increased by 1.68 times than that without them. In the present study, triangular cross-sectional shape turbulence promoters were suggested and numerically tested. Pressure drop of turbulence promoter with the 30 degree triangular cross-sectional shape decreased by 30% from that of rectangular cross-section promoters while heat transfer rate was almost the same. While with 4 turbulence promoters, the heat transfer rate increased by 21%, the pressure drop increased 4 times. It means that the higher capacity of cooling fan should be needed. With the triangular cross-sectional shape, the size of vortex region at the rear of promoters became considerably smaller, so pressure drop became smaller. The effect of the change of cross-sectional shape was not found in the flow pattern near the ribs, so that heat transfer characteristics in the ribs were not changed.

열음향냉동기의 수치적 모델 (A Numerical Model of Thermoacoustic Refrigerators)

  • 채왕병;정은수
    • 설비공학논문집
    • /
    • 제8권1호
    • /
    • pp.110-119
    • /
    • 1996
  • A numerical of thermoacoustic refrigerators has been developed. Effects of heat transfer and viscosity on pressure and velocity distributions in resonators and heat exchangers were considered. Predictions of cooling capacity and COP agreed well with previous experimental results. Effects of important design parameters, such as pressure ratio, spacing between the plates in the stack and stack length, on the performance of thermoacoustic refrigerators were shown.

  • PDF

화재에 노출된 철근콘크리트 기둥의 수치해석적 열전달 모델 (Numerical Modeling of Heat Transfer in Reinforced Concrete Columns Exposed to Fire)

  • 이차돈;신영수;이승환;이창은
    • 콘크리트학회논문집
    • /
    • 제17권6호
    • /
    • pp.871-878
    • /
    • 2005
  • 화재에 노출된 철근콘크리트 기둥은 기둥을 구성하는 재료물성의 변화와 함께 기둥의 구조적 성능에도 결과적으로 열화현상을 나타내게 된다. 기둥의 구조적 성능의 열화정도는 화재동안 기둥단면에 전달된 열의 양과 관련이 있다. 이를 예측하기 위한 합리적인 열 전달 모델은 기둥이 가열을 받는 동안 전달된 열 정도에 따라 변하는 콘크리트의 전도율 및 열용량, 그리고 단면 내 잉여수 증발에 대한 적절한 고려를 하여야 한다. 본 연구에서 제안한 모델은 양해법 유한차분법에 근거하여 개발되었으며 기존에 제안된 모델들에 비하여 이들 모든 변수들의 영향을 적절하게 고려하고 있다. 본 연구에서 개발된 모델은 기존 화해 실험에 의한 기둥 단면 내 온도를 적절하게 예측하였다.

파울링 가속장치를 이용한 공기조화기용 열교환기의 공기측 파울링 특성에 대한 예측 모델링 (Modeling of the Air-side Particulate Fouling in Finned-Tube Heat Exchangers of Air Conditioners using Accelerated Particle-Loading System)

  • 안영철;이재근
    • 설비공학논문집
    • /
    • 제17권3호
    • /
    • pp.262-267
    • /
    • 2005
  • The air-side particulate fouling in the heat exchangers of HVAC applications degrades the performance of cooling capacity, pressure drop across a heat exchanger, and indoor air quality. Indoor and outdoor air contaminants foul heat exchangers. The purpose of this study is to investigate and to model the air-side particulate fouling characteristics of the heat exchangers using accelerated particle loading system. The main variables of the modeling equation are face velocity and dust concentration. The modeling equation shows good agreements with the experimental results at the face velocity of 0.5, 1.0, 1.5 m/s and the dust concentration of 1.28 and $3.84\;g/m^3$. It will be very useful to predict fouling characteristics such as variations of pressure drop and heat transfer capacity in finned-tube heat exchangers of air conditioners.