• 제목/요약/키워드: heat stress index

검색결과 142건 처리시간 0.024초

응력 삼축성을 고려한 원자로 내부구조물 배플포머 집합체의 연성저하 평가 (Ductility Degradation Assessment of Baffle Former Assembly Considering the Stress Triaxiality Effect)

  • 김종성;박정순;강성식
    • 한국압력기기공학회 논문집
    • /
    • 제12권2호
    • /
    • pp.50-57
    • /
    • 2016
  • The study presents structural integrity assessment of ductility degradation of a baffle former assembly by performing finite element analysis considering real loading conditions and stress triaxiality. Variations of fracture strain curves of type 304 austenitic stainless steel with stress triaxiality are derived based on the previous study results. Temperature distributions during normal operation such as heat-up, steady state, and cool-down are calculated via finite element temperature analysis considering gamma heating and heat convection with reactor coolant. Variations of stress and strain state during long operation period are also calculated by performing sequentially coupled temperature-stress analysis. Fracture strain is derived by using the fracture curve and the stress triaxility. Finally, variations of ductility degradation damage indicator with the fracture strain and the equivalent inelastic strain are investigated. It is found that maximum value of the ductility degradation damage index continuously increases and becomes 0.4877 at 40 EFPYs. Also, the maximum value occurs at top and middle inner parts of the baffle former assembly before and after 20 EFPYs, respectively.

응결시간차를 활용한 매스콘크리트의 수화열 조정에 관한 기초적 연구 (A Fundamental Study on the Control of Hydration Heat of Mass Concrete Using Setting Time Difference)

  • 배정렬;윤치환;김기철;한민철;오선교;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2002년도 학술논문발표회
    • /
    • pp.41-45
    • /
    • 2002
  • Placing lift is applied to place mass concrete in order to reduce thermal cracks by hydration heat. But they results in cold joint between placing lifts, which bring about the loss of strength, water tightness and undesirable appearance. Therefore, in this paper, mechanical and hydration heat of mass concrete using super retarding agent developed through previous study are investigated in order to reduce the hydration heat and place it without place lift. According to test results, placing lifts combined with normal concrete and concrete containing super retarding agent have positive effects on reducing hydration heat. Especially, the crack index by thermal stress of the concrete containing super retarding agent less than a quarter, compared to that of plain concrete without placing lifts, and less than a half, compared to that of plain concrete with placing lifts.

  • PDF

하절기 자돈 고온 스트레스 평가를 위한 THI 지수 모의 (Estimation of THI Index to Evaluate Thermal Stress of Piglets in Summer Season)

  • 하태환;권경석;이인복;김락우;여욱현;이상연;최희철;김종복;이준엽;전중환;우샘이;양가영
    • 한국농공학회논문집
    • /
    • 제60권4호
    • /
    • pp.113-122
    • /
    • 2018
  • Thermal stress of pigs causes decreased feed consumption and weight gain rate, immunosuppression, reproductive disorders, and increased mortality. The concept of the temperature-humidity index (THI) has been widely used to evaluate the degree of thermal stress of pigs. However, use of this concept is strongly restricted for animals living in the enclosed facilities. In this study, Building Energy Simulation (BES) technique was used to realize the energy flow among outside weather conditions, building materials, and animals. Especially, mechanisms of sensible and latent heat generation from pigs according to surrounding air temperature and their weight were designed to accurately evaluate the THI values inside the pig house. The THI values computed by the BES model were compared to those calculated by method of the report (NIAS, 2016), the model of this study predicted the start date of heat stress about 9~76 days earlier compared to the NIAS model. Results of the BES model also showed higher frequencies of the THI above the THI threshold for pigs, indicating that conventional model has a possibility of underestimating the degree of heat stress of pigs.

지하철 구조물의 온도균열제어를 위한 시공조건별 해석적 영향 분석 (Parametric Analysis on Construction Conditions to Control Thermal Cracks in Subway Concrete Structure)

  • 김연태;김상철
    • 한국철도학회논문집
    • /
    • 제7권4호
    • /
    • pp.312-318
    • /
    • 2004
  • The wall in a subway structure is easily subject to crack occurrence since its expansion and shrinkage associated with hydration heat reaction is constrained by the slab. The greater problem is that the crack in the wall may be developed to pass through thickness and eventually deteriorate the structure due to rusting of reinforced steel. Thus, this study aims at controlling thermal cracks as much as possible and determining an optimized size of concrete placement through hydration heat analysis. For this study, effects of placement height, length, temperature and types of cement on the thermal cracks were evaluated by temperature rise, thermal stress and crack index. As results of parametric study, it was found that placement height and length do not have an effect on the temperature rise but have significant one on thermal stress which relates to direct possibility of thermal crack occurrence. This means that proper selection of size balancing internal constraint with external one is much more important than reducing the placement height and length simply. In order to prevent from thermal cracks most effectively, in addition, it was noted to reduce placement temperature and to use the cement blended with mineral admixture.

Effect of γ-Aminobutyric Acid-producing Lactobacillus Strain on Laying Performance, Egg Quality and Serum Enzyme Activity in Hy-Line Brown Hens under Heat Stress

  • Zhu, Y.Z.;Cheng, J.L.;Ren, M.;Yin, L.;Piao, X.S.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제28권7호
    • /
    • pp.1006-1013
    • /
    • 2015
  • Heat-stress remains a costly issue for animal production, especially for poultry as they lack sweat glands, and alleviating heat-stress is necessary for ensuring animal production in hot environment. A high ${\gamma}$-aminobutyric acid (GABA)-producer Lactobacillus strain was used to investigate the effect of dietary GABA-producer on laying performance and egg quality in heat-stressed Hy-line brown hens. Hy-Line brown hens (n = 1,164) at 280 days of age were randomly divided into 4 groups based on the amount of freeze-dried GABA-producer added to the basal diet as follows: i) 0 mg/kg, ii) 25 mg/kg, iii) 50 mg/kg, and iv) 100 mg/kg. All hens were subjected to heat-stress treatment through maintaining the temperature and the relative humidity at $28.83{\pm}3.85^{\circ}C$ and 37% to 53.9%, respectively. During the experiment, laying rate, egg weight and feed intake of hens were recorded daily. At the 30th and 60th day after the start of the experiment, biochemical parameters, enzyme activity and immune activity in serum were measured. Egg production, average egg weight, average daily feed intake, feed conversion ratio and percentage of speckled egg, soft shell egg and misshaped egg were significantly improved (p<0.05) by the increasing supplementation of the dietary GABA-producer. Shape index, eggshell thickness, strength and weight were increased linearly with increasing GABA-producer supplementation. The level of calcium, phosphorus, glucose, total protein and albumin in serum of the hens fed GABA-producing strain supplemented diet was significantly higher (p<0.05) than that of the hens fed the basal diet, whereas cholesterol level was decreased. Compared with the basal diet, GABA-producer strain supplementation increased serum level of glutathione peroxidase (p = 0.009) and superoxide dismutase. In conclusion, GABA-producer played an important role in alleviating heat-stress, the isolated GABA-producer strain might be a potential natural and safe probiotic to use to improve laying performance and egg quality in heat-stressed hens.

초지연제를 이용한 매스콘크리트의 수화열 조정에 관한 연구 (A Study on the Control of Hydration Heat of Mass Control Using Super Retarding Agent)

  • 유동수;심보길;윤치환;한민철;한천구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.469-474
    • /
    • 2001
  • Mass concrete is placed considering placing lifts in order to reduce thermal cracks by hydration heat. But they results in cold joint between placing lifts, which bring about the loss of strength, water tightness and undesirable appearance. Therefore, in this paper, mechanical and hydration heat of mass concrete using super retarding agent developed through previous study are investigated in order to reduce the hydration heat and place it without place lift. According to test results, placing lifts combined with normal concrete and concrete containing super retarding agent have positive effects on reducing hydration heat. Especially, the crack index by thermal stress of the concrete containing super retarding agent less than a quarter, compared to that of plain concrete without placing lifts, and less than a half, compared to that of plain concrete with placing lifts.

  • PDF

초지연제를 이용한 매스콘크리트의 수화열 조정에 관한 연구 (A Study on the Control of Hydration Heat of Mass Concrete Using Super Retarding Agent)

  • 유동수;심보길;윤치환;한민철;한천구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.515-520
    • /
    • 2001
  • Mass concrete is placed considering placing lifts in order to reduce thermal cracks by hydration heat. But they results in cold joint between placing lifts, which bring about the loss of strength, water tightness and undesirable appearance. Therefore, in this paper, mechanical and hydration heat of mass concrete using super retarding agent developed through previous study are investigated in order to reduce the hydration heat and place it without place lift. According to test results, placing lifts combined with normal concrete and concrete containing super retarding agent have positive effects on reducing hydration heat. Especially, the crack index by thermal stress of the concrete containing super retarding agent less than a quarter, compared to that of plain concrete without placing lifts, and less than a half, compared to that of plain concrete with placing lifts.

  • PDF

원자로건물 외벽 타설 높이 산정을 위한 수화열 해석 (Analysis on Heat of Hydration for Height of Shell Concrete Pouring in Reactor Containment Building)

  • 김좌영;박종혁;이한우;방창준
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2012년도 추계 학술논문 발표대회
    • /
    • pp.165-166
    • /
    • 2012
  • A thermal stresses by heat of hydration was analyzed according to a change of a pour height in reactor containment building. In case of more than 3.6m pouring height a crack index by heat of hydration analysis resulted in less than 1 because there is not a construction joint of vertical direction and for a self-restraint effect of circumferential section shape. Therefore detailed consideration on a mixture proportion of binder type, quantity in concrete and selection of a form in seasonal air temperature is needed for a control of tensile stress by heat of hydration.

  • PDF

LiNAC실 벽체 구조물의 온도 균열 제어 (Thermal Crack Control of Wall Elements in LiNAC Structure)

  • 손명식;도율호;나운;박찬규;이회근
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.413-416
    • /
    • 2006
  • This paper presents the analytical results on the heat of hydration and induced thermal cracking of the wall elements in LiNAC that is a radioactive shield concrete structure. This wall elements measuring 1.2 m in thickness and 32 m in length tend to exhibit thermal cracking due to heat of hydration and high constraint effects caused by slab element located in the lower part of structure. In this analysis, four different construction stages were considered to find out the most effective concrete casting method in terms of thermal stress. Among the construction methods adopted in this analysis, the method of installation of construction connection measuring 1.2 m at the both side of wall elements was very effective way to control the thermal stress, resulting in increase thermal cracking index of wall elements in LiNAC structure. Finally, the wall elements in LiNAC structure was cast successfully according to the proposed construction method.

  • PDF

고온건강경보시스템 기준 설정에 관한 연구( I ) - 기준 설정 및 검증 - (Study on the Establishment of Threshold Criteria for Heat Health Watch Warning System in Korea; Part I : Establishment of Criteria and Verification)

  • 박종길;정우식;김은별
    • 한국환경과학회지
    • /
    • 제18권7호
    • /
    • pp.767-780
    • /
    • 2009
  • This study investigates the standard, duration period and excess mortality of extreme heat using the standardized daily mortality data from 1991 to 2004, establishing a standard threshold Criteria for Heat Health Watch Warning System in Korea. It ultimately aims to provide the guidance in building up Heat Health Watch Warning System for Korea by suggesting the standard to quantify thermal stress from heat. The standard threshold Criteria for Heat Health Watch Warning System for Seoul metropolitan city takes into account both daily maximum temperature and daily maximum heat index(HI) and consists of four phases; caution, extreme caution, danger, and extreme danger. Extreme caution phase and danger phase are used as the advisory and warning of extreme heat, respectively. Since the nationwide distribution of the frequency of extreme heat day and the excess mortality rate shows little difference across regions, the standard threshold Criteria for Heat Health Watch Warning System for Seoul metropolitan city can be used for other regions.