• 제목/요약/키워드: heat storage rate

검색결과 319건 처리시간 0.024초

건조 및 초저온 처리에 의한 뽕나무 종자의 장기 보존 (Cryopreservation of Mulberry(Morus) Seeds in Liquid Nitrogen(L$N_2$))

  • 최영철;류근섭;방혜선
    • 한국잠사곤충학회지
    • /
    • 제42권1호
    • /
    • pp.1-5
    • /
    • 2000
  • To investigate the possibility of crypreservation of mulberry seeds in liquid nitrogen(LN$_2$), characteristics of the seeds were examined after picking mulberry syncarps and drying-heat treatment. Storage in LN$_2$has the potential of providing indifinite preservation of valuable seed germplasm. Determining the tolerance of seeds among given cultivars to LN$_2$cooling and subsequent rewarming is the first step to establishing the feasibility of LN$_2$storage. Seeds of 4 mulberry varities were treated to LN$_2$(-196$\^{C}$) for 24 hours after drying heat treatment. Seed moisture content of Daeryukppong was the highest. As moisture content of mulberry seed was below 1%, storage in LN$_2$was safe. And drying heat treatment for 60 minutes was suitable to prevent decreased germination rate and germination vigor of seeds. The seeds of Cheongilppong were unsuibable to cryopreserve in LN$_2$for longterm storage.

  • PDF

자갈축열 태양열 온실의 공기유동 및 축열 성능 (Air Flow and Heat Storage Performance of Solar-Heated Greenhouse with Rock Bed Storage)

  • 이석건;이종원;이현우
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2001년도 학술발표회 발표논문집
    • /
    • pp.275-280
    • /
    • 2001
  • The purpose of this study was to investigate the air flow characteristics of the rock bed storage for solar-heated greenhouse design. Heat storage material was gravels and experiments were performed under constant inside temperature condition. The experimental parameters were operation method and air flow rate of fan. It was resulted that the temperature and amount of heat stored in rock-bed increased as the increase of air flow velocity and were more influenced by operation of inlet fan than outlet fan.

  • PDF

슬래브축열 시스템 설계인자의 감도해석 (A Sensitivity Analysis of Design Factors of Air-Conditioning System with Slab Thermal Storage)

  • 정재훈
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.590-595
    • /
    • 2008
  • In this paper, the sensitivity analysis was examined about the main factors that compose an air-conditioning system with slab thermal storage by using the analytic solution. Those factors are the insulation performance of floor slab surface, the slab thickness, the heat capacity of floor slab, the air change rate, and the insulation performance of the wall. The slab thickness and heat capacity of floor slab that minimize heating loads was gained by sensitivity analysis. It is became clear that the insulation performance of slab surface, high airtightness and high heat insulation are important design factors in air conditioning system with slab thermal storage.

  • PDF

맨틀형 축열조의 열전달 성능 및 특성에 관한 실험적 연구 (An Experimental Study on the heat transfer characteristics and performance of storage tanks with mantle heat exchanger)

  • 강용혁;곽희열;윤환기;유창균;윤현식;천원기
    • 한국태양에너지학회 논문집
    • /
    • 제21권1호
    • /
    • pp.61-69
    • /
    • 2001
  • The heat transfer characteristics of horizontal and vertical mantle heat storage tanks are studied in order to replace the tank-coil heat exchanger for application in thermosyphon solar water heaters. In this study, 5 mantle storage tanks with different geometric shape are manufactured into stainless steel and each tank is tested. For the test, The inlet flow rate of the heat transfer fluid is maintained 1.2 lpm consistently. The heat transfer fluid temperature through the mantle is $70{\pm}1^{\circ}C$. The temperatures of 26 points included the ambient temperature are measured at every one minute. The measured data are used to calculate the overall heat transfer coefficient(UA) using the LMTD(Log Mean Temperature Difference) method and it is used on the analysis of the heat transfer characteristics to search for optimum arrangement.

  • PDF

축열식 전기보일러용 마이크로프로세서 제어장치개발 (The development of microprocessor_based controller for the electrical boiler of heat storage type)

  • 김종수;박정우;조기연;김요희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1989년도 추계학술대회 논문집 학회본부
    • /
    • pp.250-253
    • /
    • 1989
  • As the necessity of increasing the midnight base load is extensively increased, electric power companies have to increase the demand of midnight electrical power by lowering the electrical charge rate at midnight. One of the most widely used midnight equipments is the heat Storage type's electrical boiler. A Single chip microprocessor controller for the heat-storage type's electrical boiler is developed. This controller call reduce the undesirable peak load at the begining of midnight (i.e.11 P.M.) time band by using backward load control method. Futhermore, this controller enables reservation of heat storge and the effective heating control the field test has been done by use the boiler for 66$m^2$ with the heater of 21KW quality.

  • PDF

파라핀을 채운 수직원관 내에서의 열전달 특성 (Heat Transfer Characteristics for Inward Melting in a Paraffin-Filled Vertical Cylinder)

  • 염성배;홍창식
    • 태양에너지
    • /
    • 제12권3호
    • /
    • pp.60-69
    • /
    • 1992
  • 본 연구에서는 고-액 상변화 시의 잠열을 이용한 축열방법 중에서 고상파라핀을 충전한 수직원관의 관벽을 가열하여 축열하는 경우에 대하여 관 내에서 일어나는 열전달 특성과 축열속도를 이론적으로 해석하였다. 액상에서는 자연대류를 고려하였고 고상에서는 순수 열전도 모델을 사용하였다. 고상파라핀의 초기온도와 관벽의 가열온도 그리고 관의 형상비가 축열속도에 미치는 영향을 알아보았으며, 전체 열전달과정을 순수열전도 모델로 해석하여 자연대류가 축열에 미치는 영향을 고찰하였다. 용융초기에는 관벽과 고액경계면의 영향으로 자연대류에 의한 유동은 장애를 받으나, 40% 정도의 용융이 진행된 후 부터는 내부 액상에서의 자연대류가 활발히 일어나고, 용융중기로 갈수록 관의 상부에 뜨거운 액상층이 축적되므로 자연대류는 소멸하게 된다. 전체적인 융용속도는 순수열전도에 의한 용융속도보다 빨라지게 된다. 관벽의 가열온도와 형상비가 증가할수록 관 내에서의 자연대류가 활발하게 일어나므로 용융속도는 빨라지며, 형상비가 클수록 상하부 간에 불균등한 용융이 일어난다. 고상의 초기온도는 초기의 용융속도에 큰 영향을 미치고 용융이 진행될수록 그 효과는 줄어든다.

  • PDF

냉매 과냉각 시스템을 이용한 열펌프의 성능향상에 관한 연구 (Performance Enhancement of the Heat Pump Using the Refrigerant Subcooling System)

  • 손창효;윤찬일;박승준;이동건;오후규
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2001년도 춘계학술대회 논문집
    • /
    • pp.106-111
    • /
    • 2001
  • The performance characteristics of heat pump system using the new refrigerant subcooling system were investigated. The new heat pump system has the ice storage tank to accumulate the latent heat of the refrigerant during the night-time. The heat is released to subcool the saturated refrigerant liquid at the outlet of a condenser in the daytime. The experimental apparatus is a well-instrumented heat pump which consisted of a refrigerant loop and a coolant loop. The test sections(condenser and evaporator) were made of tube-in-tube heat exchanger with the horizontal copper tube of 12.7[mm] outer diameter and 9.5[mm] inner diameter. The evaporating temperatures ranged from $-5[^{\circ}C]$ to $0[^{\circ}C]$ and the subcooling degrees of the refrigerant varied from $15[^{\circ}C]$ to $25[^{\circ}C]$. The test of the ice storage was carried out at evaporating temperature of $-10[^{\circ}C]$ and the ice storage mode is an ice-on-coil type. The main results were summarized as follows ; The refrigerant mass flow rate and compressor shaft power of the heat pump system were independent of the subcooling degrees. The cooling capacity o the heat pump system increases as the evaporating temperature and subcooling degree increases. The cooling capacity of the heat pump system is about 25 to 30% higher than that of normal heat pump system. The COP of the heat pump system which subcooled the refrigerant liquid at the outlet of the condenser is about 28% higher than that of the normal heat pump system.

  • PDF

냉매 과냉각을 이용한 열펌프 시스템의 성능 특성 (The Performance Characteristics of Heat Pump Using the Refrigerant Subcooling)

  • 노건상;손창효
    • 한국수소및신에너지학회논문집
    • /
    • 제18권4호
    • /
    • pp.413-421
    • /
    • 2007
  • In this paper, the performance characteristics of heat pump system using a new refrigerant subcooling system designed for the study, are introduced. The new heat pump system have the ice storage tank at the outlet of condenser. The experimental apparatus is a well-instrumented water/water heat pump which consisted of working fluid loop, coolant loop, and ice storage tank. The experiment parameters of subcooling ranged as the evaporating temperature from $-5^{\circ}C$ to $8^{\circ}C$, the condensing temperature from $30^{\circ}C$ to $35^{\circ}C$. The test of the ice storage was carried out at evaporating temperature of $-10^{\circ}C$ and the ice storage mode is Ice-On-Coil type. The working fluid was R-22 and the storage materials were city-water. The test results obtained were as follows; The refrigerant mass flow rate and compressor shaft power were unchanged by the degrees of subcooling, that is, they were independent of degrees of subcooling. The cooling capacity of the new heat pump system increase as the evaporating temperature and subcooling degrees increase and is higher by $25{\sim}30%$, compared to the normal heat pump system. The COP of the new heat pump system increases as the degrees of subcooling and evaporating temperature increase and is higher by 28% than that of the normal heat pump system.

축열식 심야전력기기를 위한 축열량 제어기 설계 (Design of a Controller for the Heat Capacity of Thermal Storage Systems Using Off-Peak Electricity)

  • 이은욱;양해원
    • 제어로봇시스템학회논문지
    • /
    • 제7권1호
    • /
    • pp.1211-1217
    • /
    • 2001
  • This paper presnts a controller for the heat capacity of thermal storage systems using off-peak electricity which is composed of an identifier using neural networks and a storage time adjuster in order to store exactly the required thermal energy without loss. Since thermal storage systems have nonlinear characteristics and large time constant, even if we predict the heating load accurately, it is very difficult to store exactly the required thermal energy. Thus, in the neural network for the identifier, the adaptive learning rate for high learning speed and bit inputs based on state changes of thermal storage power source are used. Also a hardware for the controller using a microprocessor is developed. The performance of the proposed controller is shown by experiment.

  • PDF

수소저장합금 반응용기에서 수소 흡.탈장과정에서의 열 및 물질전달 특성에 관한 실험적인 연구 (An Experimental Study of Heat and Mass Transfer During Absorption and Desorption Processes in a Hydride Material Bed)

  • 박찬우;강병하;이춘식
    • 대한기계학회논문집
    • /
    • 제19권1호
    • /
    • pp.202-211
    • /
    • 1995
  • Heat and hydrogen transfer characteristics have been experimentally investigated for a hydride reaction bed, in which hydride material LaN $i_{4,7}$A $l_{0.3}$ is contained for hydrogen storage. This problem is of particular interest in the design of metal hydride devices such as metal-hydride refrigerators, heat pumps, or metal-hydride storage units. Transient behavior of hydrogen transfer through the hydride materials as well as heat transfer is studied during absorption and desorption processes in detail. The experimental results obtained indicate that the mass flow of the hydrogen is strongly affected by the governing parameters, such as the initial pressure of the reaction bed, absorption or desorption period, and cooling or heating temperature. These mass transfer results are along with the heat transfer rate between hydride materials and heat transfer medium in the reaction bed.d.d.