• 제목/요약/키워드: heat storage rate

검색결과 319건 처리시간 0.024초

$Ca(OH)_2$ 충전층의 열분해 반응 촉진 (Rate Enhancement of Thermal Decomposition Reaction in the $Ca(OH)_2$ Packed Bed)

  • 정수열;김도완;김종식
    • 태양에너지
    • /
    • 제15권1호
    • /
    • pp.73-84
    • /
    • 1995
  • [ $Ca(OH)_2$ ]의 열분해 반응을 이용하는 화학축열법에서는 $Ca(OH)_2$ 입자 충전층의 열전도성이 나쁘기 때문에 축열과정의 소요시간이 길어 실용화에 커다란 장애가 되고 있다. 본 연구에서는 $Ca(OH)_2$ 입자 충전층의 열전달을 촉진시키기 위해 반응기속에 구리판으로 된 전열핀을 설치하고 열분해 탈수반응 실험을 하였다. 그 결과 전열핀이 없는 경우보다 탈수반응에 소요되는 시간을 1/2 이하로 크게 단축시킬 수 있었다.

  • PDF

병영시설의 태양열급탕시스템에 관한 연구 (A Study on the Solar Water Heating System in the Military Facilities)

  • 김두천;서진석
    • 대한설비공학회지:설비저널
    • /
    • 제11권4호
    • /
    • pp.6-18
    • /
    • 1982
  • The performance of two typical types of solar hot water heating system was tested in Seoul. Types of systems studied are single-tank internal external heat exchanger system and single-tank internal heat exchanger system. Comparing to experimental results, a transient system simulation program was made to analyze the performance of the selected system. The climate data, Standard Weather Year for Seoul, required for the simulation was provided. Computer simulations were used to estimate the effect of significant parameters upon system performance. The followings are obtained. 1. In the domestic solar water Heating system, the value $20-40kg/m^2\;h$ for flow rate through the collector is much better than the recommended value $72kg/m^2\;h$ in the solar heating system. 2. The effectiveness of collector heat exchanger and storage tank size are found to have only a small effect upon system performance. 3. The hot water draw pattern has a significant effect on system performance. A higher system efficiency achieved when draw-off occurred around noon than when it occurred around early morning. Using the above results, the reference solar hot water system which provides $300\ell$ of hot water per day, was selected as a guide for designer. And simplified graphical method was developed based on the modified f-chart method to determine required collector area. When the system design parameters of the proposed system differs from the reference system, required collector area can be calculated from area adjustment factors.

  • PDF

볶음밥의 Bacillus cereus 위해 수준 및 위해 관리를 위한 모니터링 기준 설정 (Prevalence of Bacillus cereus from Fried Rice Dishes and Monitoring Guidelines for Risk Management)

  • 장혜자;이지혜
    • 한국식품조리과학회지
    • /
    • 제25권1호
    • /
    • pp.45-54
    • /
    • 2009
  • Contamination levels of aerobic colony counts, coliforms and pathogenic bacteria were tested in fried rice dishes to monitor quality for risk management. The prevalence of Bacillus cereus in dishes from 8 Chinese-style restaurants and 2 institutional foodservices was 10%, and the bacteria's contamination levels was 3.47 log CFU/g. Echerichia coli, Staphylococcus aureus, and Salmonella were not detected in any of the 10 samples. However, for their aerobic colony counts and numbers of isolated coliforms, the samples were 30% and 70% over the microbial criteria, respectively, for ready-to-eat foods presented in the Korean Food Code. This suggests that fried rice dishes, although cooked with oil at high temperature, require special care. For the prediction of the growth curve of B. cereus spp. in the fried rice samples, an experiment design of 3 storage temperatures ($7^{\circ}C$, $35^{\circ}C$, $57^{\circ}C$) x 5 storage times (0 h, 2 h, 4 h, 6 h, 24 h) was applied. The sample exposed to $35^{\circ}C$ showed no B. cereus spp. at 0 h; however, there was a tendency of slow growth (1.0 log CFU/g) after 4 hours of storage and then faster growth at 6 h (3.7 log CFU/g) and 12 h (4.7 log CFU/g), showing a growth rate of 0.56 log CFU/g/hr. These results indicate that fried rice, despite being heat-treated, can become heavily contaminated with B. cereus spp. when held over 2 hours at room temperature. However, the samples stored at $7^{\circ}C$ and $57^{\circ}C$ over 24 hours were not contaminated with B. cereus. Based on these results, management guidelines for controlling B. cereus are suggested.

LNG 벙커링용 고효율 LNG 저장탱크 열해석 (Thermal analysis of LNG storage tank for LNG bunkering system)

  • 윤상국
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제39권9호
    • /
    • pp.876-880
    • /
    • 2015
  • IMO의 규제인 신조 선박에 대한 NOx 80% 감축의 2016년 발효를 앞두고, 청정에너지인 LNG연료 선박 및 벙커링 선박의 보급이 유럽 선진국들을 중심으로 추진되고 있다. LNG 저장탱크는 LNG 벙커링의 필수 설비로 현재의 액체질소 등을 저장하는 극저온 액체 저장탱크와 동일한 구조이며, IMO의 "C"형 가압탱크인 내외 용기로 구성된 2중 탱크에 진공펄라이트 단열재가 충전되는 형식이다. 그러나 이 단열방식은 진공작업이 어렵고 일 LNG 기화량이 2.0 % 내외가 되어 보다 고효율의 탱크가 요구되어 진다. 본 연구에서는 진공과 단열재를 분리하여 내외탱크에 고진공을 적용하고 외부 탱크에 우레탄폼을 가설시킨 탱크 단열 방식을 새로이 고안하여 열해석을 수행하였다. 해석결과 본 개발 탱크는 진공도가 $10^{-3}Torr$ 이하일 때 일 기화량이 0.03 % 이하로 매우 적게 유지될 수 있고, $10^{-4}Torr$ 이하가 되면 일 기화량이 0.11 %가 되었다. 진공이 파괴되는 경우에도 현재 진공펄라이트 단열은 일 4.9 %의 증발이 발생하나, 새 고안 탱크는 일 증발율이 4.12 %가 되는 매우 효율이 높고 안전한 LNG 탱크 단열방식이 되었다.

조밀화된 사용후 핵연료 저장조에서의 국부 비등에 관한 연구 (A Study on the Local Boiling of the Consolidated Spent Fuel Storage Pool)

  • Lee, Chang-Ju;Lee, Kun-Jai
    • Nuclear Engineering and Technology
    • /
    • 제25권1호
    • /
    • pp.8-19
    • /
    • 1993
  • 강제순환 냉각상실사고시 조밀화된 저장계통의 사용후 핵연료에서 생성된 붕괴열의 제거를 확인하기 위한 자연순환 해석모델이 개발되었다 채택된 수치기법은 ADI방법에 근거하였다. 사용후 핵연료의 붕괴열 생성율은 ANS-79 붕괴열 모델에 따라 계산되었으며, 보수적인 붕괴열 생성량 입력을 위해 chopped sine곡선에 따른 비균일 표면열속이 가정되었다. 저장조내 국부비등의 발생 가능성을 조사하기 위해서 민감도분석이 수행되었으며, 이는 핵연료간 거리 비, 열 생성량 및 핵연료 봉 반지름 등의 여러 변수를 변경시킴으로서 이루어졌다. 이 모델의 적용결과는 적절한 냉각시간 후의 조밀화된 사용후 핵연료 다발을 통한 자연대류 유량이 안전하고 효과적인 방식으로 저장조의 온도준위를 조절할 수 있음을 보여주고 있으며, 또한 사용후 핵연료봉 재배치를 위한 냉각시간에 관한 허용기준이 얻어졌다.

  • PDF

우드칩 바이오매스를 이용한 열병합발전 운영 사례 분석 (Case Study and Evaluation of Economic Feasibility of Combined Heat and Power System using Woodchip Biomass)

  • 서길영;김성현
    • 신재생에너지
    • /
    • 제8권4호
    • /
    • pp.21-29
    • /
    • 2012
  • The extensible supply of New & Renewable energy resources desperately needs to counter the high dependence on imported energy, recent high oil prices and the Climate Change Conference, and the government has operated the 'Renewable Portfolio Standard' (RPS) as one of the renewable energy policy from 2012. By analyzing the operation case of combined heat and power plant using the woodchip biomass, we drew the price of wood chip fuel, plant capacity factor, electricity selling price, heat selling price and LCOE value. After analyzing the economic feasibility of 3MWe combined heat and power plant based on the operating performance, the minimum of economic feasibility has appeared to be secured according to the internal rate of return (IRR) is 6.34% and the net present value (NPV) is 3.6 billion won as of 20 years life time after installation, and after analyzing the cases of the economic feasibility of the price of wood chip, plant capacity factor, electricity and heat selling price are changed, the economic feasibility is valuable when the price of wood chip is over 64,000 won/ton, NPV is minus, and the capacity factor is above 46.9%, the electricity selling price is 116 won/kWh and the heat selling price is above 75,600 won/Gcal. When going over the new installation hereafter, we need the detailed review of the woodchip storage and woodchip feeding system rather than the steam-turbine and boiler which have been inspected many times, the reason why is it's hard to secure the suitable quality (constant size) of woodchip by the lack of understanding about it as a fuel because of the domestic poor condition and the calorific value of woodchip is seriously volatile compared with other fuels.

Development of Model to Evaluate Thermal Fluid Flow Around a Submerged Transportation Cask of Spent Nuclear Fuel in the Deep Sea

  • Guhyeon Jeong;Sungyeon Kim;Sanghoon Lee
    • 방사성폐기물학회지
    • /
    • 제20권4호
    • /
    • pp.411-428
    • /
    • 2022
  • Given the domestic situation, all nuclear power plants are located at the seaside, where interim storage sites are also likely to be located and maritime transportation is considered inevitable. Currently, Korea does not have an independently developed maritime transportation risk assessment code, and no research has been conducted to evaluate the release rate of radioactive waste from a submerged transportation cask in the sea. Therefore, secure technology is necessary to assess the impact of immersion accidents and establish a regulatory framework to assess, mitigate, and prevent maritime transportation accidents causing serious radiological consequences. The flow rate through a gap in a containment boundary should be calculated to determine the accurate release rate of radionuclides. The fluid flow through the micro-scale gap can be evaluated by combining the flow inside and outside the transportation cask. In this study, detailed computational fluid dynamic and simplified models are constructed to evaluate the internal flow in a transportation cask and to capture the flow and heat transfer around the transportation cask in the sea, respectively. In the future, fluid flow through the gap will be evaluated by coupling the models developed in this study.

열교환기 형상이 축소한 IRWST 내부의 풀핵비등에 미치는 복합적인 영향에 대한 실험적 연구 (Experimental Investigation of the Combined Effects of Heat Exchanger Geometries on Nucleate Pool Boiling Heat Transfer in a Scaled IRWST)

  • Kang, Myeong-Gie;Chun, Moon-Hyun
    • Nuclear Engineering and Technology
    • /
    • 제28권1호
    • /
    • pp.1-16
    • /
    • 1996
  • 축소한 격납용기 내부 핵연료재장전수저장탱크의 안쪽에 설치한 열교환기 튜브의 주요 매개변수들이 풀핵비등 열전달에 미치는 복합적인 영향을 극명하기 위해 튜브 외경, 표면 거칠기, 그리고 튜브 설치 방향에 대한 다양한 조합들을 환용하여 열유속 q'quot;와 과열 온도 차이 $\Delta$T 간의 관계에 대한 총 1,966 개의 실험값을 취득하였다. 이 실험 결과들에 의하면, (1) 표면 거칠기 증가는 수평 및 수직 튜브 모두에 대해 열전달을 향상시키고, (2) 기포 생성에 따른 두가지 열전달 기구인 주변 액체 운동증가에 의한 열전달 향상과 기포층 및 기포 군집 형성에 의한 열전달 감소는 50㎾/$m^2$의 열유속을 경계로 낮은 열유속과 높은 열유속 영 역 에서 서로 다르게 관찰되는데, 이것은 튜브 설치 방향과 표면 거칠기의 크기와 관련이 있으며, (3) 튜브 외경 증가는 수평 및 수직 튜브 모두에 대해 열전달을 감소시키는데, 그 영향정도는 수평보다 수직구조에서 더 크다. 수평 및 수직 튜브들에 대해 열유속 q'quot;와 표면 거칠기 ($\varepsilon$) 및 튜브 외경 (D) 사이의 관계를 결정하는 두 가지 실험식을 개발하였다. 그리고, q'quot;만의 함수로된 풀핵비등 열전달계수( $h_{b}$ 에 대한 간단한 실험식도 부가적으로 개발하였다. 실험식도 부가적으로 개발하였다.'quot;만의 함수로된 풀핵비등 열전달계수($h_{b}$ 에 대한 간단한 실험식도 부가적으로 개발하였다.

  • PDF

상부 코일히터를 갖춘 나선재킷형 태양열 축열조의 성능예측을 위한 CFD 해석모델 개발 및 검증 (Computational Fluid Dynamics Model for Solar Thermal Storage Tanks with Helical Jacket Heater and Upper Spiral Coil Heater)

  • 백승만;종일명;남진현;정재동;홍희기
    • 대한기계학회논문집B
    • /
    • 제37권4호
    • /
    • pp.331-341
    • /
    • 2013
  • 태양열 온수급탕 시스템에서는 태양열 에너지가 집열판에서 획득되고 열매체로 전달되어 최종적으로 온수의 형태로 축열조에 저장된다. 본 연구에서는 상부 코일히터를 갖춘 나선재킷형 축열조의 축열성능 특성을 정확하게 해석할 수 있는 전산유체역학 모델을 개발하였다. 본 연구에서 고려한 축열조는 벽면에 열매체의 나선유로가 형성된 맨틀형 축열조의 일종으로 시스템 설계 단순화, 저유량 운전, 성층화 촉진 등의 장점을 지닌다. 또한 축열조 내부에 추가적인 코일히터가 장착되어 축열성능과 성층화의 추가적인 향상을 도모할 수 있다. 본 연구에서 개발된 해석모델의 검증은 실제 태양열 온수급탕 시스템의 실증실험 결과와 비교를 통하여 수행되었으며, 온수의 온도변화, 열매체의 온도변화, 성층화 온도분포의 측면에서 잘 일치하는 결과를 얻었다.

참다래 쥬스의 이화학적 특성에 미치는 살균 및 저장온도의 영향 (Effects of Pasteurization and Storage Temperatures on the Physicochemical Characteristics of Kiwi Juice)

  • 이진원;김인환;이광원;이철
    • 한국식품과학회지
    • /
    • 제35권4호
    • /
    • pp.628-634
    • /
    • 2003
  • 본 실험은 다양한 온도에서 살균 및 저장함에 따라 참다래 쥬스의 품질에 미치는 영향을 알아보기 위하여 참다래 쥬스$(13.5^{\circ}Brix)$를 65, 75 및 $85^{\circ}C$에서 각각 15초간 살균한 뒤 4, $25^{\circ}C$의 incubator에서 30일간 저장하며, 미생물, 이화학적 특성을 조사한 결과, 대부분의 참다래 쥬스 내 세균은 $65^{\circ}C$의 가열에서 파괴되었고 저장기간 중 모든 시료에 대하여 세균 증식은 나타나지 않았다. Tubular type가열 살균기에서 살균한 참다래 쥬스 중 세균에 대한 D value는 $65^{\circ}C$에서 4.17초, $75^{\circ}C$에서 1.47초, $85^{\circ}C$에서는 0.81초로 감소하였다. Vitamin C함량의 변화는 살균온도와 저장온도 및 저장기간이 증가할수록 감소되었으며, 환원당 함량은 모든 살균조건에서 저장 20일째 최대값을 보인 후, 급격히 감소하는 경향을 나타내었다. 색도의 경우에는 모든 살균 및 저장조건에서 L, a 및 b값은 저장기간에 따라 감소하는 경향을 나타내었으며, 갈색도 변화는 저장기간이 길어질수록 지속적인 감소현상을 나타내었다.